• Title/Summary/Keyword: Width-to-thickness ratio

Search Result 462, Processing Time 0.025 seconds

A Result of Field Demonstration Experiment on the Remediation of Farm Land Soil contaminated by Heavy Metals (중금속 오염 농경지 토양의 복원을 위한 현장실증시험 결과)

  • Yu, Chan;Yun, Sung-Wook;Park, Jin-Chul;Lee, Jung-Hoon;Choi, Seung-Jin;Yoon, Seung-Moon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.265-277
    • /
    • 2009
  • A long-term field demonstration experiment of selected stabilization method to reduce the heavy metal mobility in farmland soil contaminated by heavy metals around abandoned mine site was conducted. Field demonstration experiments were established on the contaminated farmland with the wooden plate(thickness=1cm) which dimension were width=200cm, Length=200cm, height=80cm and filled with treated soil, which was mixed with lime stone and steel refining slag except on control plot. Soil samples were collected and analyzed during the experiment period(2008. 2~2008. 8) after the installation of the plots. Field demonstration experiments results showed that the application ratio of lime stone 5% was effective for immobilizing heavy metal components in contaminated farmland soil.

  • PDF

Behavior of FRP-reinforced steel plate shear walls with various reinforcement designs

  • Seddighi, Mehdi;Barkhordari, Mohammad A.;Hosseinzadeh, S.A.A.
    • Steel and Composite Structures
    • /
    • v.33 no.5
    • /
    • pp.729-746
    • /
    • 2019
  • The nonlinear behavior of single- and multi-story steel plate shear walls (SPSWs) strengthened with three different patterns of fiber reinforced polymer (FRP) laminates (including single-strip, multi-strip and fully FRP-strengthened models) is studied using the finite element analysis. In the research, the effects of orientation, width, thickness and type (glass or carbon) of FRP sheets as well as the system aspect ratio and height are investigated. Results show that, despite an increase in the system strength using FRP sheets, ductility of reinforced SPSWs is decreased due to the delay in the initiation of yielding in the infill wall, while their initial stiffness does not change significantly. The content/type/reinforcement pattern of FRPs does affect the nonlinear behavior characteristics and also the mode and pattern of failure. In the case of multi-strip and fully FRP-strengthened models, the use of FPR sheets almost along the direction of the infill wall tension fields can maximize the effectiveness of reinforcement. In the case of single-strip pattern, the effectiveness of reinforcement is decreased for larger aspect ratios. Moreover, a relatively simplified and approximate theoretical procedure for estimating the strength of SPSWs reinforced with different patterns of FRP laminates is presented and compared with the analytical results.

Revisiting the measurement of keratinized gingiva: a cross-sectional study comparing an intraoral scanner with clinical parameters

  • Ahmet Mert Nalbantoglu;Deniz Yanik
    • Journal of Periodontal and Implant Science
    • /
    • v.53 no.5
    • /
    • pp.362-375
    • /
    • 2023
  • Purpose: The aim of this study was to investigate the relationships between gingival thickness (GT) and keratinized gingiva width (KGW), papilla height (PH), and crown ratio (CR) by employing transgingival probing and an intraoral scanner (IOS). Methods: This cross-sectional study examined 360 maxillary anterior teeth from 60 patients. GT was assessed using transgingival probing with an endodontic spreader. KGW, CR, and PH were measured using an IOS. One-way analysis of variance, the Student's t-test, and Spearman correlation coefficients were employed for statistical analysis. Results: Higher GT was significantly associated with thinner KGW in the central region (P=0.019). There was no statistically significant difference in GT between teeth (P=0.06). PH was lower in lateral teeth than in canines (P=0.047), with a PH of 2.99 mm in lateral teeth. The KGW was narrower in canines than in central teeth (P=0.007). A moderate correlation was observed between KGW and PH in the central region (P=0.01), while a weak negative correlation was found between KGW and CR (P=0.043). Conclusions: A moderate negative correlation was found between GT and KGW, as well as between PH and KGW in central teeth. In contrast, a weak negative correlation existed between CR and KGW. The PH (2.99 mm) was lower in lateral teeth than in canines. The traditional paradigm, which suggests a positive correlation between KGW and GT, was reevaluated by measuring KGW using an IOS.

Local Buckling and Inelastic Behaviour of 800 MPa High-Strength Steel Beams (800MPa급 고강도강 보 부재의 국부좌굴 및 비탄성 거동)

  • Lee, Cheol-Ho;Han, Kyu-Hong;Kim, Dae-Kyung;Park, Chang-Hee;Kim, Jin-Ho;Lee, Seung-Eun;Ha, Tae-Hyu
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.4
    • /
    • pp.479-490
    • /
    • 2012
  • Flexural tests on full-scale H-shaped beams, built up from high-strength steels (HSB800 and HSA800) with a nominal tensile strength of 800 MPa, was carried out to study the effect of flange slenderness of high-strength steel on flexural strength and rotation capacity. The primary objective was to investigate the appropriateness of extrapolating current stability criteria (originally developed for ordinary steel) to high-strength steel. The performance of high-strength steel specimens was very satisfactory from the strength, but not from the rotation capacity, perspective. The inferior rotation capacity of high-strength steel beams was shown to be directly attributable to the absence of a distinct yield plateau and the high yield ratio of the material. Residual stress measurements reconfirmed that the magnitude of the residual stress is almost independent of the yield stress of the base metal.

Effects of Modified Installation Methods of Roof Ventilation Devices in the Single-span Plastic Greenhouses on Yield and Fruit Quality of Oriental Melon (단동 비닐하우스의 지붕 환기장치 설치방법 개선이 참외생육 및 과실수량에 미치는 영향)

  • Yeo, Kyung-Hwan;Yu, In-Ho;Choi, Gyeong Lee;Lee, Seong-Chan;Lee, Jae-Han;Park, Kyoungs Sub;Lee, Jung-Sup;Bekhzod, Khoshimkhujaev
    • Journal of Bio-Environment Control
    • /
    • v.25 no.4
    • /
    • pp.334-342
    • /
    • 2016
  • In order to evaluate the modified installation methods of roof ventilation devices, derived from the previous experiment ('investigation into the optimum capacity of roof ventilation devices and their deployment'), the conventional and modified (improved) roof ventilation systems were installed in the single-span plastic greenhouse for growing oriental melons. The roof vents ($60{\varphi}$) and roof fans (maximum air capacity of $38m^3/min$) were installed in the spacing of 15m (FT, modified 'side vent+roof fan' ventilation) and 6m (TT, modified 'side vent+roof vent' ventilation) respectively on the roof of greenhouses for the modified roof ventilation treatments, and 20m (FC, conventional 'side vent+roof fan' ventilation) and 8m (TC, conventional 'side vent+roof vent' ventilation) for the conventional ones. The stem diameter, leaf blade lengh, petiole length, and leaf width were lower in the FT and TT treatments than those in the conventional treatments, FC and TC. Although the fruit weight and total yields were slightly lower in the FT and TT treatments, the marketable fruit ratio (%) were higher, as a result of increased fruiting ratio (%) in these treatments, than those of FC and TC. The marketable yields (kg/10a) in the FT and TT treatments were 8,391 kg/10a and 7,283 kg/10a, which were respectively 661 kg/10a and 487 kg/10a higher than those in the treatments of FC and TC. The modified installation methods of roof fan resulted in production of more female flowers and lower fruit drop ratio (%) compared to conventional meathods. In the treatment of the conventional ventilation with roof vent, the fruit weight, fruit length & width, and flesh thickness were higher than in other treatments, but there were no significant differences in the fruit width and flesh thickness among the treatments.

Lower Extremity Reconstruction by Perforator Based Flap (천공지 기저 피판을 이용한 다양한 하지 재건)

  • Oh, Chang Hyun;Shim, Jeong Su;Park, Dae Hwan
    • Archives of Plastic Surgery
    • /
    • v.36 no.6
    • /
    • pp.720-726
    • /
    • 2009
  • Purpose: Fasciocutaneous flap with random pattern flap has limitation in mobility and length - width ratio. This characteristic is more pronounced in lower extremity which has relatively poor vascularity. Perforator based flap in lower extremity reconstruction has various advantages as a axial flap, allowing abundant blood supply and widening of mobility range. So if it is not a case of wide defect, free flap can be replaced by perforator based flap. Methods: From April 2007 to March 2009, 18 cases of perforator flap were performed. 8 had defect in upper 1/3 of calf, 6 in middle 1/3, and 4 in lower 1/3. In 10 cases island flap were used, 3 case had transposition flap, 2 cases used advancement flap, 2 case had propeller flap and 1 case had rotation flap. Results: 17 cases survived without flap necrosis. Partial flap necrosis occurred in 1 case, so secondary split thickness skin graft was done. Chronic wound with pseudomonas infection occurred in 1 case, but it was completely cured with conservative treatment. Conclusion: Perforator based flap is useful in lower extremity reconstruction because of relative freedom in changing the size and thickness of the flap depending on the recipient site, good mobility, and abundant vascularity. And donor site morbidity can be minimized. Lower extremity reconstruction using perforator based flap is a good method because it can minimize the complication and obtain effective result.

Experimental seismic behaviour of L-CFST column to H-beam connections

  • Zhang, Wang;Chen, Zhihua;Xiong, Qingqing;Zhou, Ting;Rong, Xian;Du, Yansheng
    • Steel and Composite Structures
    • /
    • v.26 no.6
    • /
    • pp.793-808
    • /
    • 2018
  • In this study, the seismic performance of the connections between L-shaped columns composed of concrete-filled steel tubes (L-CFST columns) and H-beams used in high-rise steel frame structures was investigated. Seven full-scale specimens were tested under quasi-static cyclic loading. The variables studied in the tests included the joint type, the axial compression ratio, the presence of concrete, the width-to-thickness ratio and the internal extension length of the side plates. The hysteretic response, strength degradation, stiffness degradation, ductility, plastic rotation capacity, energy dissipation capacity and the strain distribution were evaluated at different load cycles. The test results indicated that both the corner and exterior joint specimens failed due to local buckling and crack within the beam flange adjacent to the end of the side plates. However, the failure modes of the interior joint specimens primarily included local buckling and crack at the end plates and curved corners of the beam flange. A design method was proposed for the flexural capacity of the end plate connection in the interior joint. Good agreement was observed between the theoretical and test results of both the yield and ultimate flexural capacity of the end plate connection.

Buckling Strength of Concentrically Loaded High-Strength Steel Columns with Intermediate Slenderness (중심압축을 받는 고강도강 중간주의 좌굴강도 평가)

  • Kim, Dae Kyung;Lee, Cheol Ho;Han, Kyu Hong;Kim, Jin Ho;Lee, Seung Eun;Kim, Jin Won
    • Journal of Korean Society of Steel Construction
    • /
    • v.27 no.4
    • /
    • pp.377-386
    • /
    • 2015
  • In this study, inelastic buckling strength of HSA800 steel columns were tested to investigate the applicability of current column curve (KBC2009, 2010 AISC-LRFD) to HSA800 steel. Key test variables included width-thickness ratio, plate-edge restraints, and column slenderness ratio. Specimens made of ordinary steel (SM490) were also tested for comparison purposes. All the concentrically loaded HSA800 specimens exhibited sufficient buckling strength compared to the current column curve, but some of SM490 specimens showed understrength. This difference can be explained by the lower residual stress present in HSA800 specimens.

A study on the anterior tooth size discrepancies among orthodontic patients with varying malocclusions (부정교합자의 전치부 치아크기 부조화에 관한 연구)

  • Kim, Hyeok-Soo;Shim, Hae-Young;Nahm, Dong-Seok
    • The korean journal of orthodontics
    • /
    • v.35 no.6 s.113
    • /
    • pp.420-432
    • /
    • 2005
  • Bolton analysis is widely used to predict tooth size discrepancy. but its accuracy has been challenged. The purpose of this study was to describe true anterior tooth size discrepancies among orthodontic patients and to evaluate the factors that affect true anterior tooth size discrepancies. The subjects consisted of 80 patients with varying malocclusions (Class I. Class II. Class III. and Class III surgery) who were treated orthodontically. Pre-treatment models. set-up models from post-treatment models. and lateral cephalometric radiographs were analyzed The results were as follows. The means. the standard deviations. and ranges of anterior Bolton ratio in the present study were somewhat higher than those of Bolton's samples and Korean normal samples. The number of patients showing maxillary deficiency was larger than that of patients showing maxillary excess in view of true anterior discrepancies. There was a significant difference between anterior Bolton discrepancy from pre-treatment models and true anterior discrepancy from set-up models (p < 0.05) There was no significant difference in true anterior discrepancies among malocclusion groups (p > 0.05). And there was also no significant difference between the male and female groups (p> 0.05). Overbite and the incisal edge thickness of maxillary anterior teeth have little relationship with true anterior discrepancies. Multiple regression analysis showed that true anterior discrepancy was mainly determined by anterior Bolton ratio, upper incisor to occlusal plane angle after treatment. interincisal angle after treatment. and upper right lateral incisor width.

Effects of Geometric and Flow Conditions on 3-dimensional Hydrodynamic Focusing (3 차원 유체역학 집속에 대한 채널 형상 및 유동 조건의 매개변수 연구)

  • Han, Kyung-Sup;Kim, Dong-Sung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.1
    • /
    • pp.61-66
    • /
    • 2010
  • In our previous work, 3-dimensional hydrodynamic focusing microfluidic device (3D-HFMD) has been developed with the help of locally increased aspect ratio of thickness to width without any horizontal separation wall. In this study, we have investigated 3-dimensional hydrodynamic focusing behaviors inside the 3D-HFMD according to the various geometric and flow conditions. The parametric study has been extensively carried out for the effects of geometric and flow conditions on 3-dimensional hydrodynamic focusing with both 3D-HFMD and previous microfluidic device design based on three-dimensional computational fluid dynamics (CFD) simulations. The CFD simulations suggested the proper design window of channel geometry and flow conditions.