• 제목/요약/키워드: Width-to-Height ratio

검색결과 488건 처리시간 0.023초

코안다 효과를 이용한 평판 슬롯의 막냉각 성능 향상 (Improvement of Film Cooling Performance of a Slot on a Flat Plate Using Coanda Effect)

  • 김기문;김예지;곽재수
    • 한국유체기계학회 논문집
    • /
    • 제20권2호
    • /
    • pp.5-10
    • /
    • 2017
  • In this study, the Coanda effect inducing bump was applied to improve the film cooling effectiveness on the flat plate with $30^{\circ}$ and $45^{\circ}$ angled rectangular slots. The slot length to width ratio was 6. A cylindrical cap shaped structure, called Coanda bump, was installed at the exit of the slot to generate Coanda effect. The width and height of the bump was 10.5 mm and 1 mm, respectively. The film cooling effectiveness was measured at the fixed blowing ratio, M=2.0, using pressure sensitive paint (PSP) technique. The mainstream velocity was 10 m/s and the turbulence intensity was about 0.5%. Results showed that the film cooling effectiveness for case of $30^{\circ}$ angled slot was higher than that of $45^{\circ}$ angled slot. It was found that there was no positive effect of Coanda effect on the overall averaged film cooling effectiveness for the $30^{\circ}$ angled slot. On the other hand, for the $45^{\circ}$ angled slot, the film cooling effectiveness was improved with the installation of the Coanda bump.

Stability assessment of unlined tunnels with semicircular arch and straight sides in anisotropic clay

  • Bibhash Kumar;Jagdish P. Sahoo
    • Geomechanics and Engineering
    • /
    • 제35권2호
    • /
    • pp.149-163
    • /
    • 2023
  • This paper presents stability evaluation of unlined tunnels with semi-circular arch and straight sides (SASS) driven in non-homogeneous and anisotropic undrained clay. Numerical analysis has been conducted based on lower bound finite element limit analysis with second order cone programming under plane strain condition. The solutions will be used for the assessment of stability of unlined semi-circular arch tunnels and tunnels in which semi-circular roof is supported over rectangular/square sections. The stability charts have been generated in terms of a non-dimensional factor considering linear variation in undrained anisotropic strength for normally consolidated and lightly over consolidated clay with depth, and constant undrained anisotropic strength for heavily over-consolidated clay across the depth. The effect of normalized surcharge pressure on ground surface, non-homogeneity and anisotropy of clay, tunnel cover to width ratio and height to width ratio of tunnel on the stability factor and associated zone of shear failure at yielding have been examined and discussed. The geometry of tunnel in terms of shape and size, and non-homogeneity and anisotropy in undrained strength of clay has been observed to influence significantly the stability of unlined SASS tunnels.

Wind flow over sinusoidal hilly obstacles located in a uniform flow

  • Lee, Sang-Joon;Lim, Hee-Chang;Park, Ki-Chul
    • Wind and Structures
    • /
    • 제5권6호
    • /
    • pp.515-526
    • /
    • 2002
  • The wind flow over two-dimensional sinusoidal hilly obstacles with slope (the ratio of height to half width) of 0.5 has been investigated experimentally and numerically. Experiments for single and double sinusoidal hill models were carried out in a subsonic wind tunnel. The mean velocity profiles, turbulence statistics, and surface pressure distributions were measured at the Reynolds number based on the obstacle height(h=40 mm) of $2.6{\times}10^4$. The reattachment points behind the obstacles were determined using the oil-ink dot and tuft methods. The smoke-wire method was employed to visualize the flow structure qualitatively. The finite-volume-method and the SIMPLE-C algorithm with an orthogonal body-fitted grid were used for numerical simulation. Comparison of mean velocity profiles between the experiments and the numerical simulation shows a good agreement except for the separation region, however, the surface pressure data show almost similar distributions.

산지 지형에서의 오염물질 확산에 관한 가시화 연구 (Visualization of Pollutant Dispersion over Hilly Terrain)

  • 길태호;이정묵;이상준
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2003년도 추계학술대회 논문집
    • /
    • pp.47-50
    • /
    • 2003
  • The wind flow and pollutant dispersion over a two-dimensional sinusoidal hilly obstacle with slope (the ratio of height to half width) of 0.7 have been investigated experimentally and numerically. Flow over a single sinusoidal hill model was visualized in a subsonic wind tunnel. The mean velocity profiles, turbulence statistics, and pollutant concentration distribution were measured at the Reynolds number based on the obstacle height (H=40mm) oft $2.6\times10^4$. Experimental results for flow over a flat ground were agreed with the theoretical and numerical results. When a pollutant source is located behind the hilly terrain, the pollutant dispersion appeared even in the upstream region due to recirculation flow.

  • PDF

평판 핀 열교환기의 성능 향상을 위한 변형된 평판 핀에 대한 해석 (Analysis of a Modified Plate Fin for Enhanced Performance of a Plate Fin Heat Exchanger)

  • 김윤하;강형석
    • 한국자동차공학회논문집
    • /
    • 제9권3호
    • /
    • pp.84-91
    • /
    • 2001
  • Comparison between performance of a plate fin and that of a modified plate fin is investigated as a function of the position, the non-dimensional width and height of wings as well as the non-dimensional fin length using a two-dimensional separation of variables method. The ratio of the incremental rate of heat loss to that of the area of a modified plate fin is also presented as a function of the height of wings. The modified plate fin is made by attaching the wings to upper and lower sides of a plate fin. One of the results shows that performance of a modified plate fin is more improved as the wings approach left (higher) thermal reservoir.

  • PDF

배수갑문 테인터 게이트(Tainter Gate)의 진동현상에 관한 모형실험 ( I ) - 문비 밖에서 안으로의 흐름 - (Model Tests Study on Flow-induced Vibration of fainter Gate in Estuary Sulices (I) - Flow from the Gate Outside to the Gate Inside -)

  • 이성행
    • 한국농공학회논문집
    • /
    • 제46권1호
    • /
    • pp.27-34
    • /
    • 2004
  • A model test is carried out to investigate flow-induced vibration of a Tainter gate in estuary sulices. The gate model scaled with the ratio of 1:25 is made of acryl panel dimensioned 0.66m in width, 0.5m in height in the concrete test flume. Firstly, natural frequencies of the model gate are measured and the results are compared with the numerical results in order to verify the model. The amplitudes of the vibration are measured under the different gate opening and water level conditions in flow from the gate outside to the gate inside. Also 5 revised gate models with bottom width increased 0.5 cm each are tested under the different gate opening and water level. The results are analyzed to study the characteristics of the gate vibration. These test results are assessed in comparison with formerly test results, as a result, presents a design method of Tainter gate to reduce the gate vibration and a basic data for the guide manuals of gate management.

계단형 슬롯출구의 높낮이 변화에 따른 2차원 막냉각 특성 (2-Dimensional Film Cooling Characteristics with the Height Variation of a Stepped Slot Exit)

  • 손창호;김태묵;이근식
    • 대한기계학회논문집B
    • /
    • 제29권1호
    • /
    • pp.46-54
    • /
    • 2005
  • Film cooling characteristics has been examined numerically for the height variation of a stepped slot exit. In this study, the upstream wall height of the stepped slot exit varies from -2d (d = slot width) to 3d, blowing ratio ranges from 0.5 to 3, and injection angles are $15^{\circ},\;30^{\circ},\;and\;45^{\circ}$. The results showed that film cooling performance was mainly subjected to the magnitude of recirculation region near the downstream-side slot exit as well as the magnitude and the distribution region of turbulent kinetic energy due to the local velocity and momentum differences between the coolant and the main flow near the slot exit. The up-1d type slot at higher blowing ratios over 2 and the flat type slot at lower blowing ratios below 1 have the best film cooling performances, in case of the injection angles of $30^{\circ},\;and\;45^{\circ}$, respectively. Compared with the other injection angles, in case of the injection angles of $15^{\circ}$, the best film cooling performances was shown in even a higher upstream wall (up-3d) at higher blowing ratio like 3 by the gradual reduction of the coolant velocity which minimizes the local velocity differences between the coolant and the main flow near the slot exit.

Shear strength formula of CFST column-beam pinned connections

  • Lee, Seong-Hui;Kim, Young-Ho;Choi, Sung-Mo
    • Steel and Composite Structures
    • /
    • 제13권5호
    • /
    • pp.409-421
    • /
    • 2012
  • Recently, as the height of building is getting higher, the applications of CFST column for high-rise buildings have been increased. In structural system of high-rise building, The RC core and exterior concrete-filled tubular (CFST) column-beam pinned connection is one of the structural systems that support lateral load. If this structural system is used, due to the minimal CFST column thickness compared to that of the CFST column width, the local moment occurred by the eccentric distance between the column flange surface from shear bolts joints degrades the shear strength of the CFST column-beam pinned connections. This study performed a finite element analysis to investigate the shear strength under eccentric moment of the CFST column-beam pinned connections. The column's width and thickness were used as variables for the analysis. To guarantee the reliability of the finite element analysis, an actual-size specimens were fabricated and tested. The yield line theory was used to formulate an shear strength formula for the CFT column-beam pinned connection. the shear strength formula was suggested through comparison on the results of FEM analysis, test and yield lime theory, the shear strength formula was suggested.

불연속면이 존재하는 지반에서 터널굴착에 의한 하중전이 (Load-transfer mechanism in the ground with discontinuity planes during tunnel excavation)

  • 이상덕;변광욱;유건선
    • 한국터널지하공간학회 논문집
    • /
    • 제4권1호
    • /
    • pp.71-78
    • /
    • 2002
  • 본 연구에서는 지반내에 뚜렷한 불연속면의 존재로 인한 하중의 비대칭 전이특성과 이완영역의 형상을 실내실험에 기초하여 고찰하였다. 가동판(trap-door)과 바닥판(reaction plates)을 토조바닥에 설치하고, 건조한 모래지반에 연직의 불연속면을 설치하여 불연속성 지반을 형성하였다. 다양한 토피고와 불연속면의 위치를 실험변수로 적용하였다. 연구결과, 토층비(=토피고/가동판의 폭)가 1.5 이상이 되면, 토압비(전이응력/초기지반응력)는 일정한 값에 수렴되는 것으로 나타났다. 불연속면이 터널 폭 내에 위치하면 불연속면의 영향이 상대적으로 커져서 비대칭성 하중집중이 두드러지게 나타났으며, 터널폭 외부에 존재하면 비대칭성 하중집중이 상당히 감소하는 것으로 타나났다.

  • PDF

무인헬리콥터를 이용한 항공방제시스템 개발(I) - 항공방제시스템 구축을 위한 기초 분무특성 - (Development of Aerial Application System Attachable to Unmanned Helicopter - Basic Spraying Characteristics for Aerial Application System -)

  • 강태경;이채식;최덕규;전현종;구영모;강태환
    • Journal of Biosystems Engineering
    • /
    • 제35권4호
    • /
    • pp.215-223
    • /
    • 2010
  • In order to develop an precision aerial pesticide application system to be attached to an unmanned helicopter which can be applied to small lots of land, this study analyzed the flowing and spraying characteristics of the spray droplets by the main rotor downwash by setting the application conditions at the flight altitude of 3 m, the diameter of main rotor of 3.1 m, the boom length of around 2.8 m, and the spraying rate of 8 L/ha. The results of this study are summarized below. Through analysis of the covering area ratio of the spray droplets by main rotor downwash by nozzle type, boom with tilt angle and height, it was found that the covering area ratio of the twin flat-fan nozzle of around 25% was more uniform than other types of nozzle, also boom with $10^{\circ}$ tilt angle and spraying height of 3 m was shown to be the appropriate conditions for aerial application of pesticides. It was found that the nozzle position to minimize the scattering loss of spray droplets due to vortex phenomenon at both ends of the main rotor was around 10 cm from the end of the main rotor. An application test for the aerial pesticide application system attached to the HUA-ACEI unmanned helicopter developed by the Rural Development Administration showed that the range of covering area ratio of the spray droplets was 10-25%, and the spraying width was approximately 7 m when over 10% of covering area ratio was considered for valid spraying.