• 제목/요약/키워드: Wide field of view

검색결과 268건 처리시간 0.025초

Satellite Monitoring of Smoke Aerosol Plume during the Russian Fire Episode of May 2003 over Northeast Asia

  • Lee, Kwon H.;Kim, Young J.;Hoyningen-Huene, Wolfgang V.
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2003년도 Proceedings of ACRS 2003 ISRS
    • /
    • pp.491-492
    • /
    • 2003
  • The large amount of smoke produced near Lake Baikal was transported to Northeast Asia with high AOT (Aerosol Optical Thickness) as seen in satellite images. Aerosol retrieval using a separation technique was applied to MODIS (Moderate Imaging Spectroradiometer) and SeaWiFS (Sea-viewing Wide Field-of-view Sensor) data observed during 14-22 May 2003. Large AOT, 2.0~5.0 was observed on 20 May 2003 over Korea due to the influence of the long range transport of smoke aerosol plume from the Russian fires, resulting in high PM10 concentration was observed at the surface.

  • PDF

Design of the Filter Exchange Mechanism for Schmidt Telescope

  • Ji, Tae-Geun;Park, Woojin;Han, Jimin;Kim, Dohoon;Lim, Gu;Jeong, Mankeun;Im, Myungshin;Pak, Soojong
    • 천문학회보
    • /
    • 제45권1호
    • /
    • pp.67.3-68
    • /
    • 2020
  • A prime focus telescope, e.g., Schmidt telescope, has advantages especially for a wide field of view survey in astronomy. In this optical configuration, the camera is placed in front of the primary mirror. Since the installation of a typical filter wheel to the prime focus telescope causes serious obscuration of the incoming light, a customized filter device is required for high sensitivity images. In this poster, we present a new filter exchange mechanism, which can host four filters moving along quadrant directions. We plan to install this on the Celestron 36 cm Rowe-Ackermann Schmidt Astrograph (RASA 36) located at El Sause Observatory in Chile.

  • PDF

Photon-Counting Computed Tomography: Experience in Musculoskeletal Imaging

  • Jan-Peter Grunz;Henner Huflage
    • Korean Journal of Radiology
    • /
    • 제25권7호
    • /
    • pp.662-672
    • /
    • 2024
  • Since the emergence of the first photon-counting computed tomography (PCCT) system in late 2021, its advantages and a wide range of applications in all fields of radiology have been demonstrated. Compared to standard energy-integrating detector-CT, PCCT allows for superior geometric dose efficiency in every examination. While this aspect by itself is groundbreaking, the advantages do not stop there. PCCT facilitates an unprecedented combination of ultra-high-resolution imaging without dose penalty or field-of-view restrictions, detector-based elimination of electronic noise, and ubiquitous multi-energy spectral information. Considering the high demands of orthopedic imaging for the visualization of minuscule details while simultaneously covering large portions of skeletal and soft tissue anatomy, no subspecialty may benefit more from this novel detector technology than musculoskeletal radiology. Deeply rooted in experimental and clinical research, this review article aims to provide an introduction to the cosmos of PCCT, explain its technical basics, and highlight the most promising applications for patient care, while also mentioning current limitations that need to be overcome.

RANSAC-based Or thogonal Vanishing Point Estimation in the Equirectangular Images

  • Oh, Seon Ho;Jung, Soon Ki
    • 한국멀티미디어학회논문지
    • /
    • 제15권12호
    • /
    • pp.1430-1441
    • /
    • 2012
  • In this paper, we present an algorithm that quickly and effectively estimates orthogonal vanishing points in equirectangular images of urban environment. Our algorithm is based on the RANSAC (RANdom SAmple Consensus) algorithm and on the characteristics of the line segment in the spherical panorama image of the $360^{\circ}$ longitude and $180^{\circ}$ latitude field of view. These characteristics can be used to reduce the geometric ambiguity in the line segment classification as well as to improve the robustness of vanishing point estimation. The proposed algorithm is validated experimentally on a wide set of images. The results show that our algorithm provides excellent levels of accuracy for the vanishing point estimation as well as line segment classification.

DETECTION OF DUST LOADED AIRMASS IN SEAWIFS IMAGERY: AN EMPIRICAL DUST INDEX IN COMPARISON WITH MODEL-PREDICTED DUST DISTRIBUTION OVER THE PACIFIC IN APRIL,1998

  • Fukushima, H.;Schmidt, M.;Sohn, B.J.;Toratani, M.;Uno, I.
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 1999년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.89-94
    • /
    • 1999
  • The paper first proposes an empirical algorithm for detecting dust-loaded airmass observed by Sea Wide Field-of-view Scanner (SeaWiFS). The proposed dust index formula is based on the curvature of the spectral reflectance estimated from the SeaWiFS band 4 (510 nm band) through band 8 (865 nm band) data, assuming "clear ocean water" reflectance. Evaluation of the algorithm is made over several typical Asian dust images including the ones over the Pacific in April, 1998, when a major dust event was reported. The study analyzes the performance and the characteristics of the algorithm by comparing the satellite-derived dust index images with contemporaneous columnar concentration of dust particles predicted by a numerical dust transport model. The comparison reveals several small-scale differences although their dust distribution patterns show good agreement generally.

  • PDF

Development of a Full-Scale Driving Simulator for Human Sensibility Ergonomics Study

  • Lee, Woon-Sung;Cho, Jun-Hee;Park, Dong-Chan;Yoo, Seung-Chul;Shin, Jun-Su
    • 한국감성과학회:학술대회논문집
    • /
    • 한국감성과학회 2000년도 춘계 학술대회 및 국제 감성공학 심포지움 논문집 Proceeding of the 2000 Spring Conference of KOSES and International Sensibility Ergonomics Symposium
    • /
    • pp.352-357
    • /
    • 2000
  • A full-scale driving simulator is being developed as an effective test-bed for reproducing realistic driving situation in a safe and tightly controlled environment and conducting various human sensibility ergonomics studies. The simulator will be equipped with a 6 degree-of-freedom, high frequency motion base and a 4 channel, wide field-of-view visual system. The simulator will be fully interactive, highly realistic, and yet economical, taking advantages of the fast growing PC technology.

  • PDF

Design of a See-Through Head-Mounted Display with a Freeform Surface

  • Wang, Junhua;Liang, Yuechao;Xu, Min
    • Journal of the Optical Society of Korea
    • /
    • 제19권6호
    • /
    • pp.614-618
    • /
    • 2015
  • This paper described an off-axis head-mounted display system. It is composed of a 7-piece coaxial relay lens group and a freeform surface combiner. This configuration has a simple structure and a wide field of view (FOV). In this design, a freeform surface is chosen as the combiner, to simplify the structure and attain good image quality. We generated this freeform surface by considering both coordinates and normals of discrete data points. Moreover, we realize a coaxial structure in the relay lens group, which is compact and benefits from a loose tolerance requirement. The HMD system we finally realized has a 40° × 30° FOV and 15-mm exit pupil diameter.

고전압 방전 검출용 자외선 코로나 카메라 개발 및 방전 이미지 분석 (Analysis of Image and Development of UV Corona Camera for High-Voltage Discharge Detection)

  • 김영석;송길목;방선배;김종민;최명일
    • 조명전기설비학회논문지
    • /
    • 제25권9호
    • /
    • pp.69-74
    • /
    • 2011
  • In this paper, the UV corona camera was developed using the solar blind and Multi Channel Plate(MCP) technology for the target localization of UV image. UV camera developed a $6.4[^{\circ}]{\times}4.8[^{\circ}]$ of the field of view as a conventional camera to diagnose a wide range of slightly enlarged, and power equipment to measure the distance between the camera and the distance meter has been attached. UV camera to measure the discharge count and the UV image was developed, compared with a commercial camera, there was no significant difference. In salt spray environments breakdown voltage was lower than the normal state, thereby discharging the image was rapidly growing phenomenon.

공간 변화 영상을 이용한 재활로봇의 비쥬얼 서보잉 시스템에 관한 연구 (Visual Servoing System Based on Space Variant Imaging for Rehabilitation Robots)

  • 송원경;이희영;변증남
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 하계종합학술대회 논문집
    • /
    • pp.763-768
    • /
    • 1999
  • The space variant imaging system which mimics the human beings visual system has some merits such as wide field-of-view, the low computational cost and the high accuracy in matching of correspondence points of stereo images. In this presentation, a visual servoing system based on the space variant imaging technique is proposed for the control of the rehabilitation robot arm. The position information of an object obtained by space variant imaging techniques is used for the visual servoing. According to the empirical data, the degree of correlation extracted by the space variant imaging technique is more accurate than that of the space invariant imaging technique.

  • PDF

차량용 어안렌즈 카메라 캘리브레이션 및 왜곡 보정 (Camera Calibration and Barrel Undistortion for Fisheye Lens)

  • 허준영;이동욱
    • 전기학회논문지
    • /
    • 제62권9호
    • /
    • pp.1270-1275
    • /
    • 2013
  • A lot of research about camera calibration and lens distortion for wide-angle lens has been made. Especially, calibration for fish-eye lens which has 180 degree FOV(field of view) or above is more tricky, so existing research employed a huge calibration pattern or even 3D pattern. And it is important that calibration parameters (such as distortion coefficients) are suitably initialized to get accurate calibration results. It can be achieved by using manufacturer information or lease-square method for relatively narrow FOV(135, 150 degree) lens. In this paper, without any previous manufacturer information, camera calibration and barrel undistortion for fish-eye lens with over 180 degree FOV are achieved by only using one calibration pattern image. We applied QR decomposition for initialization and Regularization for optimization. With the result of experiment, we verified that our algorithm can achieve camera calibration and image undistortion successfully.