• Title/Summary/Keyword: Whole-Body

Search Result 2,797, Processing Time 0.03 seconds

Effect of Whole Body Vibration Training on Proprioception and Tactile in Spastic Cerebral Palsy (전신진동 자극 훈련이 경직형 뇌성마비 아동의 고유수용감각 및 촉각에 미치는 영향)

  • Yun, Hye-Lyeong;Lee, Eun-Ju
    • PNF and Movement
    • /
    • v.20 no.1
    • /
    • pp.103-113
    • /
    • 2022
  • Purpose: The purpose of this study was to investigate the effects of whole-body vibration stimulation on proprioception and tactile in patients with spastic cerebral palsy. Methods: This study was conducted on 9 children diagnosed with spastic cerebral palsy. Of the single case study methods, the ABAB design was employed in this study. Out of a 12-week study period, three weeks were allocated to each of two baseline periods and two intervention periods. The exercise was performed twice a week for 30 minutes. A general trunk stabilization exercise was performed during the baseline period and a trunk stabilization exercise accompanied with whole-body vibration was performed during the intervention period. Evaluation was performed five times in total: before the experiment, after baseline 1, after intervention 1, after baseline 2, and after intervention 2. To determine the effect of the exercise method, a skin sensory evaluation tool (monofilament kit) and a trunk proprioception sensor (digital dual inclinometer) were used. To compare the effects of the exercises at baseline and after intervention, an analysis of variance on repeated measures (repeated ANOVA) was performed to analyze the data. Results: The results showed that there were statistically significant increases from baseline in the means of proprioception and tactile during the intervention period with whole-body vibration (p <.05). Conclusion: Whole-body vibration can be proposed as an effective intervention method for improving the proprioception and tactile in children with spastic cerebral palsy, and this exercise method is expected to be actively used in clinical practice.

Measurement of Effective Half-life Using Dual Time I-131 Whole Body Scan in Patients with Differentiated Thyroid Cancer Treated by High Dose Therapy (고용량 방사성옥소 치료를 받은 갑상선분화암 환자에서 Dual Time I-131 Whole Body Scan을 이용한 유효반감기의 측정)

  • Yoon, Jae Sik;Lee, Jae Gon;Lee, Ki Hyun;Lim, Kwang Seok;Choi, Hak Ki;Lee, Sang Mi
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.98-103
    • /
    • 2014
  • Purpose: The effective half life of I-131 is useful to calculate radiation dose, period of hospitalization, and exposure dose of surrounding people from patient. However, it is difficult to measure. This study estimates the effective half life in whole body and thyroid in using of value of residual radioactivity obtained from the early and delay images of Dual time I-131 whole body scan. Also, the correlations between the effective half life and serum creatinine, GFR, and administration dose were investigated in this study. Materials and Methods: The targets were 50 patients administration high dose of I-131 from February to August in 2013, having normal range of serum creatinine and over $30{\mu}IU/mL$ of TSH levels. After administration radioactive I-131, the early scan in the 3rd day and the delay scan in the 5-6th days were performed. To measure the residual radioactivity in the whole body and thyroid, ROI was set and then background radioactivity was corrected to estimate. The effective half life was estimated by calculating the ratio of measured values between the early and delay images. To compare the effective half lives of the whole body and thyroid, it was analyzed by Independent t-test, and each correlation of the effective half life, GFR, serum creatinine, and the dose of administration were analyzed by calculating the pearson's correlation coefficient. All of the analysis were determined to be statistically significant when P<0.05. Results: The effective half life of the whole body was $17.06{\pm}5.50$ hours and of the thyroid was $17.22{\pm}5.41$ hours. The two effective half life did not show significant difference (P=0.887). As the value of GFR was increased, the effective half life of whole body (r=-0.407, P=0.003) and of thyroid (r=-0.473, P=0.001) were significantly decreased; as the value of serum creatinine was increased, the effective half life of whole body (r=0.309, P=0.029) and of thyroid (r=0.371, P=0.008) were significantly increased. In the administration dose, effective half life did not have correlations. Conclusion: The effective half life of I-131 of patients treated for their thyroids were estimated only by using the images of Dual time I-131 whole body scan. Also, the correlations with the effective life, GFR, and serum creatinine were examined. This study might be utilized for a study on optimization for the period of hospitalization of patients treated by high dose of I-131 and on evaluation for internal absorbed dose of MIRD schema in application of the effective half life.

  • PDF

Motion Analysis of Kolman Technique by Korean Top Gymnasts on Horizontal Bar (국내 우수선수들의 철봉 Kolman 기술 동작 분석)

  • Lim, Kyu-Chan;Lee, Nam-Koo
    • Korean Journal of Applied Biomechanics
    • /
    • v.31 no.4
    • /
    • pp.283-289
    • /
    • 2021
  • Objective: The aim of this study was to analyze the pattern of Kolman technique by five Korean top gymnasts including the three national athletes on horizontal bar. Method: Two digital high-speed camcorders were used with 90 frames/sec and their Kolman motions were filmed in sports science secondary school gymnasium at U city. After the kinematic and kinetic variables were carried out by Kwon3D 3.1 motion package during the whole phase, the optimized release motion was investigated by simulating the body COG path during the aerial phase. Results: Firstly, it was revealed that the average changes of hip, shoulder joint angle were 84 deg, 53 deg respectively during the functional sub-phase and the average swing phaseal time was 1.21 s. Secondly, it was revealed that the average body COG positions and velocities (Y, Z) at release were -0.65 m, 0.48 m, 1.65 m/s, 3.97 m/s respectively and the average release angle, peak height and flight time were 67 deg, 1.29 m, 0.79 s respectively. Thirdly, it was revealed that the directions of somersault of whole and lower body, tilt of lower body were counterclockwise, whereas the directions of tilt of whole body, twist of whole and lower body were clockwise at the ready for re-grasp. Lastly, it was revealed that the body COG paths were different from each other during the aerial phase followed by the different body COG velocities. Conclusion: Korean gymnasts of this study controlled their motions well in terms of the timing of hip·shoulder joint, body position, body angular momentum especially during the functional sub-phase, but their motions were different during the aerial phase. Nonetheless most of them made the adequate body position at the instant of re-grasp. It would be suggested that Korean gymnasts except S3 should increase the vertical velocity.

Fatigue-Decreased Proficiency(FDP) Boundary for Whole-Body Vibration Exposure in Passenger Car Driver (승용차 운전자의 전신진동노출에 대한 피로-감소숙달 경계)

  • Jeung ae Yeal;Lee Ki-Nam
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.16 no.6
    • /
    • pp.1211-1216
    • /
    • 2002
  • To evaluate whole-body vibration(WBV) exposure and fatigue-decreased proficiency(FDP) boundary in passenger car driver, several roads in Busan were divided into 3 types by the condition of road surface; Road 1 was partially damaged, Road 2 was normal without damage, and Road 3 was better than Road 2. The results were following: The highest passenger driver's exposures to whole-body vibration acceleration and fatigue-decreased proficiency boundary at 40km/h were 0.108m/s² and about 2099 minutes in Road 2 for xh axis, 0.134m/s² and about 1585 minutes in Road 2 for yh axis, and 0.183m/s² and about 1053 minutes in Road 2 for zh axis, respectively. The highest passenger driver's exposures to whole-body vibration acceleration and fatigue-decreased proficiency boundary at 80km/h were 0.219m/s² and about 830 minutes in Road 3 xh axis, 0.203m/s² and about 918 minutes in Road 3 for yh axis, and 0.622m/s² and about 195 minutes in Road 1 for zh axis, respectively. The highest vector sums of whole-body vibration exposure at 40km/h and 804km/h were 0.328m/s² in Road 2 and 0.730m/s² in Road 1, respectively. The highest crest factors at 40km/h were 4.25 in Road 1 for xh, 4.51 in Road 3 for yh, and 5.81 in Road 2 for zh, respectively. The highest crest factors at 80km/h were 5.57 in Road 1 for xh, 5.60 in Road 2 for yh, and 6.46 in Road 3 for zh, respectively. The highest transmissibilities of whole-body vibration from floor to seat at 40km/h and 80km/h were 0.89 in Road 3 and 0.82 in Road 3 for xh axis, 0.83 in Road 3 and 0.87 in Road 1 and 2 for yh, and 0.80 in Road 2 and 0.92 in Road 1 tor zh axis, respectively. The highest fatigue-decreased proficiency boundaries for whole-body vibration exposure of passenger car driver in floor and seat were 457 minutes in Road 3 and 583 minutes in Road 3 at 40km/h and 159 minutes in Road 2 and 251 minutes in Road 2 at 80km/h, respectively.

Effects of the Whole-body Vibration Exercise Combined with Ankle Joint Mobilization on the Gait Function and Balancing Ability in Stroke Patients: A Preliminary Randomized, Controlled Study (발목관절 가동술과 결합한 전신진동운동이 뇌졸중 환자의 보행 기능과 균형 능력에 미치는 영향: 무작위 대조 예비연구)

  • Su-Bong, Son;Kyoung-Wook, Choi;Tae-Wu, Kim;Sang-Young, Park;Yong-Jun, Cha
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.17 no.4
    • /
    • pp.103-111
    • /
    • 2022
  • PURPOSE: This study was performed to investigate the effects of the whole-body vibration exercise combined with ankle joint mobilization on the gait and balancing ability in patients with hemiplegic stroke. METHODS: A total of 19 patients at a rehabilitation hospital who had suffered a hemiplegic stroke were randomly assigned to the experimental group (whole-body vibration exercise combined with ankle joint mobilization, n=10) or control group (whole-body vibration exercise, n=9). All participants underwent 30 min of comprehensive rehabilitation therapy (5 × /week for 6 weeks). Additionally, the experimental group performed the whole body vibration exercise and ankle joint mobilization (15 minutes each, 30 minutes total, 3 × / week for 6 weeks). In the control group, only the whole- body vibration exercise was performed in the same manner and not the ankle joint mobilization. The gait and balancing abilities were measured before and after the 6-week training. RESULTS: Significant improvements were observed in the 10-m walk test, timed up-and-go (TUG) test, center of pressure (COP) path length, and COP path velocity in the experimental group (p < .05). The experimental group showed a larger decrease in the COP path length and velocity than the control group (COP path length, -10.27 mm vs. -3.67 mm, p < .05; COP path velocity, -.33 cm/sec vs. -.13 cm/sec, p < .05, respectively). CONCLUSION: The whole-body vibration exercise combined with ankle joint mobilization could be effective in improving the gait and balancing ability of stroke patients and could also be more effective for improving the static balance ability than the general whole-body vibration exercise alone.

A study on Whole Body Vibration in Subway System (지하철 전동차에서의 전신진동 특성에 관한 연구)

  • Jeong, Sang Wook;Park, Sang Kyu
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.7 no.1
    • /
    • pp.87-98
    • /
    • 1997
  • In this study, subway train vibration has been measured to characterize the whole body vibration of Seoul subway lines for various human postures. Results show that the floor vibration level of the subway trains in the vertical direction is higher than that in other directions. At the standing human posture, vibration level of the head in the right-left direction are increased while that in the vertical direction is decreased. It is assumed that the different flexibility of the human body and the rolling motion of the subway trains are the main cause. At the sitting posture with back seat on, vibration level in the right and left direction at the human ischial tuberosities is lower than that in other directions. Results also show that there were little difference between back-seat on model and back-seat off model. Transmissibility analysis shows how the subway vibration affects the response of a human body.

  • PDF

EFFECT OF TRYPSIN-DIGESTED BOVINE GROWTH HORMONE ON WHOLE-BODY PROTEIN SYNTHESIS IN VITRO IN CHICKEN EMBRYOS

  • Kita, K.;Hatano, S.;Okumura, J.;Muramatsu, T.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.6 no.2
    • /
    • pp.319-323
    • /
    • 1993
  • The effect of bovine growth hormone digested with trypsin on whole-body protein synthesis in vitro of chicken embryos was investigated by using a whole-embryo culture system. Bovine growth hormone at 5.3 and 530 ng/ml was digested partially and completely with trypsin for 4 min and 18 h, respectively. After culturing chicken embryos with a synthetic medium containing $L-[4-^3H]$ pheylalanine, whole-embryo protein synthesis was determined from the ratio of specific radioactivities of free and protein-bound pheylalanine. Whole-embryo protein synthesis of the control group cultured with no bovine growth hormone was $49.5{\pm}2.2%/d$. There was no significant interaction between digestion time and the concentration of trypsin-digested bovine growth hormone. Tryptic digestion of bovine growth hormone increased fractional synthesis rates of whole-body protein compared to the 0-min groups, and there was no significant difference between the 4-min and 18-h groups. The higher concentration (530 ng/ml) of trypsin-digested bovine growth hormone was more effective in enhancing whole-embryo protein synthesis than the lower concentration (5.3 ng/ml).

The Biomechanical Analysis of the Cuervo Salto Forward Straight Vaults with Twists (도마 몸 펴 쿠에르보 비틀기 동작 분석)

  • Lim, Kyu-Chan
    • Korean Journal of Applied Biomechanics
    • /
    • v.15 no.4
    • /
    • pp.143-151
    • /
    • 2005
  • This study was conducted to investigate the technical factors of Cuervo forward straight vaults with single twist, single and half twists, and double twists actually performed by three execellent male gymnasts participated in artistic gymnastics competition of 2003 summer Universiade in Daegu and the 85th National Sports Festival in Cheongju. To accomplish the research goals the Cuervo vaults of three gymnasts were filmed by using three digital camcorders set by 60 Hz, and data were collected through the DLT method of three dimensional cinematography. The kinematic and kinetic variables as each phasic time, CM displacement velocity, release angle inclination angle hip joint angle landing angle, average horse reaction force average moment arm average torque, whoe body's total remote local angular momentum were analyzed, so the following conclusions were reached. Generally to perform the better Cuervo vault, a gymnast should touch down on the board with the great horizontal velocity of the whole body through the fast run-up, and touch down on the horse by decreasing the horizontal displacement of the whole body during the preflight, so raise CM height gradually within a short horse contact time. He should increase the horse reaction force through checking the horizontal velocity of the whole body effectively and the inclination angular displacement of the handstand, if so he can have the large vertical velocity of the whole body. By using the acquired the velocity and the angular momentum of the whole body, he can vault himself higher and twist sufficiently, then he can get better if the body could be tilted by swinging both arms and perform the cat twist with a little flexions at hip joints. According to the above outcomes we can judge that the best athletes is LuBin, the better is YTY, and the next is JSM.

Evaluating the Usability of Medical Body Wrap in Whole Body Bone Scan (전신 뼈 검사에서 의료용 신체 고정구의 유용성 평가)

  • Dong-Oh Shim;Woo-Young Jung;Jae-Kwang Ryu;Cheol-Hong Park;Yoon-Jae Kim
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.28 no.1
    • /
    • pp.49-56
    • /
    • 2024
  • Purpose: When performing nuclear medicine examinations, body wraps or plastic supports are used to support and immobilize the patient's upper extremities to prevent patient safety accidents. However, the existing plastic supports compromised patient and staff safety, including finger entrapment and falls. Moreover, the body wrap provided by manufacturers compromised image quality such as upper extremities cutoff during whole body bone scan. Therefore, a new design of body wrap was developed to improve the issue, and this study aims to evaluate the usability of this medical body wrap. Materials and Methods: To evaluate the usability of the newly designed medical body wrap, a quality assessment of whole body bone scan images and a user satisfaction survey were conducted. Adult patients (male:female=129:152, age: 60.3±12.4 years, BMI: 24.0±4.2) aged 16 years or older who underwent a whole body bone scan during two periods: June to July 2022 (before improvement, n=139) and June to July 2023 (after improvement, n=142) were randomly selected for image quality evaluation. Five radiotechnologists visually evaluated the posterior view of the whole body bone image, including the left and right elbow (2 points), arm (2 points), whether the hand is extended (2 points), whether the hand is included (2 points), and the number of visible fingers (10 points), with a total of 18 points, which were converted to 100 points and analyzed for difference before and after improvement using an independent sample t-test. The user satisfaction questionnaire was evaluated using a 5-point Likert scale among 16 radiotechnologists from three general hospitals who experienced the new body wrap. Results: The image quality assessment was 82.0±13.8 before the improvement and 89.3±10.1 after the improvement, an average of 7.3 points higher, with a statistically significant difference (t=5.02, p<0.01). The user satisfaction survey showed an overall satisfaction rating of 4.1±0.8 for ease of use, 3.8±0.7 for scan preparation time, 3.9±0.7 for patient safety, 3.8±1.2 for scan accuracy, and 4.2±0.7 for recommendation (87.5% questionnaire response rate). Conclusion: The developed body wrap showed higher image quality and user satisfaction compared to the old method. Considering these results, it is deemed that the new body wrap may be more useful than existing methods.

Measurements of Whole-body Vibration Exposed from UH60-Helicopter and Their Analysis Results (UH60 헬기 조종사의 피폭진동 측정 및 평가 결과)

  • Cheung, Wan-Sup;Byeon, Joo-Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.132-137
    • /
    • 2005
  • This paper addresses what amount of whole-body vibration is exposed to pilots of UH60 helicopters during flight. To measure the whole-body exposed from the feet and seat, the 12-axis vibration measurement system was used. It enables simultaneous measurement of vibration exposure from the body contact area of the feet, hip and back. The measured 12-axis vibration signals are exploited to the comfort level of UH60 helicopters during flight. It is shown that the evaluated ride value is close to $0.74{\sim}0.79m/s^2$ and that it is equivalent to the semantic scale of 'fairly uncomfortable'. To assess the health effects of whole-body vibration exposed to pilots of UH60 helicopters during their flight, the rms-based and VDV(vibration dose value)-based evaluation results of measured four-axis vibration signals are shown in this work. The fatigue-decreased proficiency limit, whose level is half of the exposure limit, is expected to come after the two-hour flight. The exposure limit is shown to reach after the 10-hour flight.

  • PDF