• Title/Summary/Keyword: Whole body scan

Search Result 179, Processing Time 0.024 seconds

Evaluation of Image Quality by Parameter Change in Onco Flash (Onco Flash에서 매개변수 변화에 따른 영상의 질 평가)

  • Cha, Eun-Sun;Noh, Ik-Sang;Kim, Ki;Choi, Choon-Ki;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.30-34
    • /
    • 2009
  • Purpose: Many companies developed a lot of programs with continuous effort for program upgrading. With this acquire superior image quality for the purpose of quick examination and progress in spatial resolution. This study was to obtained clinical usefulness on a appropriate parameter of FWHM for speed and alpha value for superior image quality. Materials and Methods: Gamma camera by Siemens (e.cam) and spatial resolution phantom and four quadrant bar phantom used. Compared for FWHM by changed scan speed 15, 20, 25, 30, 35, 40 cm/min in scatter and non scatter in Onco Flash of spatial resolution phantom. Visual evaluation of count rate and bar phantom image for increased of alpha value of 10% in 0~100%. Results: FWHM by the scan speed was 9.37, 9.40, 9.28, 9.30, 9.31, 9.53 mm in the scatter. Count rate increased alpha value 10% increased. Visual evaluation was suitable to below 30%, Therefore spatial resolution improved on FWHM at the scan speed 25~35 cm/min applying for alpha value 30% in Onco Flash was average 9.3 mm less than FWHM of below 15 cm/min and above 40 cm/min. Conclusion: We found on appropriate parameter to progress of image quality. And there be a useful guideline for you that appropriate scan speed on vary in parameters of reduction on examination time and advancing image quality.

  • PDF

Necessity for a Whole-body CT Scan in Alert Blunt Multiple Trauma Patients. (의식이 명료한 다발성 외상환자에게 전신 전산화단층촬영이 반드시 필요한가?)

  • Mun, You-Ho;Kim, Yun-Jeong;Shin, Soo-Jeong;Park, Dong-Chan;Park, Sin-Ryul;Ryu, Hyun-Wook;Seo, Kang-Suk;Park, Jung-Bae;Chung, Jae-Myung;Bae, Ji-Hye
    • Journal of Trauma and Injury
    • /
    • v.23 no.2
    • /
    • pp.89-95
    • /
    • 2010
  • Purpose: Whole-body CT is a very attractive diagnostic tool to clinicians, especially, in trauma. It is generally accepted that trauma patients who are not alert require whole-body CT. However, in alert trauma patients, the usefulness is questionable. Methods: This study was a retrospective review of the medical records of 146 patients with blunt multiple trauma who underwent whole body CT scanning for a trauma workup from March 1, 2008 to February 28, 2009. We classified the patients into two groups by patients' mental status (alert group: 110 patients, not-alert group: 36 patients). In the alert group, we compared the patients' evidence of injury (present illness, physical examination, neurological examination) with the CT findings. Results: One hundred forty six(146) patients underwent whole-body CT. The mean age was $44.6{\pm}18.9$ years. One hundred four (104, 71.2%) were men, and the injury severity score was $14.0{\pm}10.38$. In the not-alert group, the ratios of abnormal CT findings were relatively high: head 23/36(63.9%), neck 3/6(50.0%), chest 16/36(44.4%) and abdomen 9/36(25%). In the alert group, patients with no evidence of injury were rare (head 1, chest 6 and abdomen 2). Nine(9) patients did not need any intervention or surgery. Conclusion: Whole-body CT has various disadvantages, such as radiation, contrast induced nephropathy and high medical costs. In multiple trauma patients, if they are alert and have no evidence of injury, they rarely have abnormal CT findings, and mostly do not need invasive treatment. Therefore, we should be cautious in performing whole-body CT in alert multiple trauma patients.

Analysis of the Spatial Dose Rates According to the Type of Radiation Source Used in Multi-bed Hospital Room (다인병실에서 이용되는 방사선원의 종류에 따른 공간선량률 분석)

  • Jang, Dong-Gun;Kim, Junghoon;Park, Eun-Tae
    • Journal of radiological science and technology
    • /
    • v.40 no.3
    • /
    • pp.407-413
    • /
    • 2017
  • Medical radiation offers significant benefits in diagnosing and treating patients, but it also generates unnecessary radiation exposure to those nearby. Accordingly, the objective of the present study was to analyze spatial dose rate according to types of radiation source term in multi-bed hospital rooms occupied by patients and general public. MCNPX was used for geometric simulation of multi-bed hospital rooms and radiation source terms, while the radiation source terms were established as whole body bone scan patients and imaging using a portable X-ray generator. The results of simulation on whole body bone scan patients showed $3.46{\mu}Sv/hr$ to another patient position, while experimental results on imaging using a portable X-ray generator showed $1.47{\times}10^{-8}{\mu}Sv/irradiation$ to another patient position in chest imaging and $2.97{\times}10^{-8}{\mu}Sv/irradiation$ to another patient position in abdomen imaging. Multi-bed hospital room, unnecessary radiation generated in the surrounding patients, while legal regulations and systematic measures are needed for radiation exposure in multi-bed hospital rooms that are currently lacking in Korea.

Evaluation of the Usefulness of Virtual Reality Equipment for Relieving Patients' Anxiety during Whole-Body Bone Scan (전신 뼈 검사 환자의 불안감 해소를 위한 가상현실 장비의 유용성 평가)

  • Kim, Hae-Rin;Kim, Jung-Yul;Lee, Seung-Jae;Baek, Song-Ee;Kim, Jin-Gu;Kim, Ga-Yoon;Nam-Koong, Hyuk;Kang, Chun-Goo;Kim, Jae-Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.26 no.1
    • /
    • pp.27-32
    • /
    • 2022
  • Purpose When performing a whole-body bone scan, many patients are experiencing psychological difficulties due to the close distance to the detector. Recently, in the medical field, there is a report that using virtual reality (VR) equipment can give pain relief to pediatric patients with weak concentration or patients receiving severe treatment through a distraction method. Therefore, in this paper, VR equipment was used to provide psychological stability to patients during nuclear medicine tests, and it is intended to evaluate whether it can be used in clinical practice. Materials and Methods As VR equipment, ALLIP Z6 VR (ALLIP, Korea) was used and the experiment was conducted after connecting to a mobile phone. The subjects were 30 patients who underwent whole-body bone examination from September 1, 2021 to September 30, 2021. After intravenous injection of 99mTc-HDP, 3 to 6 hours later, VR equipment was put on and whole body images were obtained. After the test, a survey was conducted, and a Likert scale of 5 points was used for psychological anxiety and satisfaction with VR equipment. Hypothesis verification and reliability of the survey were analyzed using SPSS Statistics 25 (IBM, Corp., Armonk, NY, USA). Results Anxiety about the existing whole-body bone test was 3.03±1.53, whereas that of anxiety after wearing VR equipment was 2.0±1.21, indicating that anxiety decreased to 34%. When regression analysis of the effect of the patient's concentration on VR equipment on anxiety about the test, the B value was 0.750 (P<0.01) and the t value was 6.181 (P<0.01). decreased and showed an influence of 75%. In addition, overall satisfaction with VR equipment was 3.76±1.28, and the intention to reuse was 66%. The Cronbach α value of the reliability coefficient of the questionnaire was 0.901. Conclusion When using VR equipment, patients' attention was dispersed, anxiety was reduced, and psychological stability was found. In the future, as VR equipment technology develops, it is thought that if the equipment can be miniaturized and the resolution of VR content images is increased, it can be used in various clinical settings if it provides more realistic stability to the patient.

Discrepancy of Bone Metastases between F-18 FDG PET/CT and Bone Scan in a Patient with Prostate Cancer (전립선암에서 골전이 진단에 대한 F-18 FDG PET/CT와 골스캔의 불일치)

  • Choi, Seung-Jin;Kim, Chul-Soo;Byun, Sung-Su;Hyun, In-Young
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.5
    • /
    • pp.275-278
    • /
    • 2006
  • We report the case of a 73-year-old man who had prostate cancer with bone metastases. Tc-99m HDP Whole body bone scan revealed multiple areas of increased bony uptake consistent with widespread bone metastases. F-18 fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) demonstrated mild F-18 FDG uptake in the lymph nodes of neck, abdomen, and pelvis. However, abnormal F-18 FDG uptake was not seen in the skeletal system. Biopsy and immunohistochemical stains of left supraclavicular mass showed metastatic prostate adenocarcinoma. Currently, there are a few reported cases of F-18 FDG PET/CT evaluation of bone metastases in prostate cancer. We discuss the discrepancy between F-18 FDG PET/CT and bone scan in the detection of osseous metastases of prostate cancer.

Camurati-Engelmann's Disease on $^{99m}Tc$-MDP Bone Scan (Camurati-Engelmann 병의 뼈스캔 소견)

  • Yoon, Hai-Jeon;Oh, So-Won;Paeng, Jin-Chul;Lee, You-Kyung;Choi, In-Ho;Lee, Dong-Soo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.6
    • /
    • pp.596-599
    • /
    • 2009
  • A 24 year-old female presented for a $^{99m}Tc$-methylene diphosphonatae (MDP) whole body bone scan due to chronic pain in the bilateral lower extremities that has aggravated since 2002. She was diagnosed with Camurati-Engelmann disease (CED) based on the clinical and radiological findings in 2002, and she re-visited our institute to evaluate disease status at this time. CED is a rare autosomal dominant type of bone dysplasia characterized by progressive cortical thickening of long bones, and narrowing of medullary cavity, and thus presents with typical clinical symptoms and signs such as chronic pain in the extremities, muscle weakness, and waddling gait. On the $^{99m}Tc$-MDP bone scan performed to evaluate disease status, intense increased uptake was seen in the skull, facial bones, bilateral scapulae, bilateral long bones, and bilateral pelvic bones, which clearly demonstrated the extent of CED involvement.

The study on Standard Uptake Value(SUV) change according to time input difference in PET/CT scan (PET/CT 검사에서 시간 입력 차이에 따른 표준화섭취계수(SUV) 변화에 대한 고찰)

  • Kim, Kyung-Sik;Lee, Ju-Young;Jung, Woo-Young;Kim, Jung-Sun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.21-25
    • /
    • 2011
  • Purpose: $^{18}F$-FDG Fusion Whole Body PET scan is performed approximately 1 hour after injecting $^{18}F$-FDG. At this point in the injection procedure, as a tool of the criteria of time input, time of clocks or computers can be used and in the scan procedure, time of workstation can be used. In case that synchronized time input is not done in the injection and scan procedures for PET scan, time error from injection to scan can occur. This time error may affect Standard Uptake Value (SUV) being used as quantitative assessment. Therefore, in this study, we analyzed the change of SUV according to time input difference and necessity of time synchronization. Materials and Methods: The analysis was performed to 30 patients ($54.8{\pm}15.5$ years old) who examined $^{18}F$-FDG Fusion Whole Body PET scan in Department of nuclear medicine, Asan Medical Center from December 2009 to February 2010. To observe the change of SUV according to time input difference, the image was reconstructed and analyzed by artificially changing time difference of 1, 2, 3, 5, 10, 20 min against the same patients based on 60 minutes. Result: SUV of the image that reconstructed the images of 30 patients by giving intervals of 1, 2, 3, 5, 10, 20 min respectively and the image that entered original time was compared and analyzed through paired t-test. Based on 0 minute, mean SUV of aorta was changed by 0.3, 1.1, 1.4, 3.2, 4.7, 12.5% respectively and there was no statistically significant difference in 1, 2 minutes (p>0.05) but there was significant difference in 3, 5, 10, 20 min (p<0.05). The changes of $SUV_{avg}$ of liver were 1.6, 2.5, 3.0, 4.2, 6.6, 12.8% in 1, 2, 3, 5, 10, 20 min respectively and the changes of $SUV_{max}$ of primary lesion were 1.0, 1.5, 2.2, 3.5, 6.6, 12.8% respectively (p<0.05). Conclusion: Errors may occur in the process of measuring or recording variables affecting SUV such as height and weight of patients, $^{18}F$-FDG dose, Emission scan start time etc. and as these errors are more, the accurate assessment of SUV is interfered. Therefore, in order to assess SUV more accurately, it is thought that efforts to minimize these errors should be made. Of these efforts, time synchronization will be a cornerstone for accurate scanning.

  • PDF

Examination about Utility of Prone Position in PET/CT of Stomach Cancer Patient (위암 환자의 양전자 방출 컴퓨터 단층 검사에서 복와위(伏臥位) 촬영의 유용성에 대한 연구)

  • NamKoong, Hyuk;Park, Hoon-Hee;Oh, Shin-Hyun;Bahn, Yung-Kag;Kim, Jung-Yul;Lim, Han-Sang;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.93-99
    • /
    • 2010
  • Purpose: Currently, PET/CT scan has been known to provide useful information to both preoperative and postoperative examination of cancer patients. Contracted stomach by the long fasting could cause difficulties of interpretation because of its size on reconstructed image data. To solve this problem, after the whole body PET/CT scan, patients were administrated in drinking 300 mL of water to expand stomach and performed additional scan on stomach region. Not only PET/CT scan but also CT performs this water-administration, and patients were take oral solution to make stomach expand for stomach cancer. When this scan performed, patients lay supine position. In this study, we evaluated the capacity of stomach through PET/CT scan with drinking water performed in supine and prone position so that we can distinguish exact location of cancer around pylorus and inferior wall of stomach. Furthermore, image data from supine and prone positions were analyzed the difference of volume of stomach through the change of standardized uptake values. Materials and Methods: From July 2009 to January 2010 in severance hospital, 30 patients who were diagnosed as early gastric cancer or advanced gastric cancer were chosen. All patients had PET/CT scan before the operation and have had follow-up PET/CT. The patients fast for at least 8 hours, and had an injection intravenously with $^{18}F$-FDG, 7.4 MBq (0.2 mCi/kg) per kilogram. They were rested for 60 minutes. Before the examination, all patients were administrated to drink water for 300 mL Patients had PET/CT scan with supine position around the region of stomach, whole body, and around the region of stomach with prone position after drinking another 300 mL of water respectively. Results: As a results of comparison between stomach capacity of 30 patients in supine and prone position, the study draw results that average capacity of stomach body was 460.29 $mm^2$ in supine position, and 641.39 $mm^2$ in prone position for 30 patients. The change of capacity shows 41.3% expanded in prone position. And there was no noticeable difference at maximum standardized uptake values in supine position and prone position. Conclusion: As results, stomach would have more expanded capacity in prone position than supine position. For patients who have physical disabilities to move freely, additional scan in prone position will be obstacle to perform. However, if additional scan in supine position add with the scan in prone position, it will be easier to diagnose stomach cancer. Moreover, we believe that this study will help the research for inventing support tools for patients who have physical disabilities in prone position.

  • PDF

Development of Male Fitted Torso Type Basic Patterns According to the Body Surface Segment Method (체표면분할법에 의한 성인 남성용 피티드 토르소형 원형 설계)

  • Suh, Chu-Yeon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.33 no.7
    • /
    • pp.1109-1120
    • /
    • 2009
  • This study develops a fitted torso type basic pattern for men by utilizing 3D body scan data. Recent fashion trends are reflected in the development of the pattern. The subjects were 15 men in their 20's, who wear size 95 (M size). Body scan data was obtained through a 3D whole body scanner (WB4, Cyberware, USA), and a body surface development figure for developing male fitted torso type basic pattern was attained through the use of Rapid Form 2006 as well as Auto CAD 2006 programs. The results are as follows: A body surface development figure through body surface segment method showed high exactitude in an error range of 100$\pm$1%. In addition, it occurred in an error range of 100:1:3% because of the hard scanning conditions in the incline of the shoulder and armpit areas. However, the body surface development figure as well as the direct measurement results can be used as basic data for the given patternmaking since the error range falls into 100$\pm$3%. Dart amounts obtained from the average cross section were center back 2.2cm (24.3%), back armpit point 3.8cm (41.8%), front armpit point 3.0cm (33.9%). As shown the jacket pattern, the biggest dart amount was portioned out at the back armpit point. The drafting equations for the development pattern acquired are as follows; Full width=C/2+5cm, back length=height/4-1cm, armhole depth=(C/10+12cm)+3cm, back width=2C/10+2cm, front width=2C/10. The development pattern was a fitted torso basic pattern that was composed of 3 pieces, so it would be very useful in developing shirt or jacket patterns. According to the results of the evaluation of the developed pattern appearance, it obtained higher scores of over 3.5 points in almost items, meaning that the developed pattern is appropriate for a male fitted torso type basic pattern. It suggests a possibility of patternmaking from a body surface development figure in 2-D to prototype.

Drafting Method of Upper Bodice Pattern using 3-D Anthropometric Data for Elderly Women (노년 여성 3-D 입체형상 데이터를 활용한 상반신 원형 설계방법 연구)

  • Suh, Chu-Yeon;Park, Soon-Jee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.32 no.5
    • /
    • pp.846-858
    • /
    • 2008
  • This study was designed to propose a method to draft bodice block pattern from 3D body scan data. Subjects were ten elderly women in their 60's, who wear basic size(B: 94cm, W: 82cm) garment. Scanning was done using 3D whole body scanner(WB4, Cyberware). Measurements for 3D data and cross section were attained using Auto CAD, by which a upper bodice pattern for elderly women was drawn on the basis of short measured method. The results are as following: As for most items, no significant differences were shown between measurements from Martin's anthropometry and those from 3D scan data, suggesting measurement from 3D scan data could be used to draft a pattern. The drafting equations acquired were as follows; width of pattern=B/2+5.5, width of waist=W/2+3.5cm, dart amount=8cm. Dart distributions were 23%(B.P.) : 20%(front armpit) : 17%(side seam) : 18%(back armpit) : 15%(back protruded point) : 7% (center back line). Through wearing test using 5-point Likert scale, resultant pattern was evaluated as appropriate for elderly women's pattern to get over 4 point. As a result, it might be said that 3D scanning application is effective for elderly women in that it doesn't take time so much as Martin's anthropometry and that their body shape vary compared with those of young women.