• 제목/요약/키워드: Whole body scan

검색결과 179건 처리시간 0.031초

Missed Skeletal Trauma Detected by Whole Body Bone Scan in Patients with Traumatic Brain Injury

  • Seo, Yongsik;Whang, Kum;Pyen, Jinsu;Choi, Jongwook;Kim, Joneyeon;Oh, Jiwoong
    • Journal of Korean Neurosurgical Society
    • /
    • 제63권5호
    • /
    • pp.649-656
    • /
    • 2020
  • Objective : Unclear mental state is one of the major factors contributing to diagnostic failure of occult skeletal trauma in patients with traumatic brain injury (TBI). The aim of this study was to evaluate the overlooked co-occurring skeletal trauma through whole body bone scan (WBBS) in TBI. Methods : A retrospective study of 547 TBI patients admitted between 2015 and 2017 was performed to investigate their cooccurring skeletal injuries detected by WBBS. The patients were divided into three groups based on the timing of suspecting skeletal trauma confirmed : 1) before WBBS (pre-WBBS); 2) after the routine WBBS (post-WBBS) with good mental state and no initial musculoskeletal complaints; and 3) after the routine WBBS with poor mental state (poor MS). The skeletal trauma detected by WBBS was classified into six skeletal categories : spine, upper and lower extremities, pelvis, chest wall, and clavicles. The skeletal injuries identified by WBBS were confirmed to be simple contusion or fractures by other imaging modalities such as X-ray or computed tomography (CT) scans. Of the six categorizations of skeletal trauma detected as hot uptake lesions in WBBS, the lesions of spine, upper and lower extremities were further statistically analyzed to calculate the incidence rates of actual fractures (AF) and actual surgery (AS) cases over the total number of hot uptake lesions in WBBS. Results : Of 547 patients with TBI, 112 patients (20.4 %) were presented with TBI alone. Four hundred and thirty-five patients with TBI had co-occurring skeletal injuries confirmed by WBBS. The incidences were as follows : chest wall (27.4%), spine (22.9%), lower extremities (20.2%), upper extremities (13.5%), pelvis (9.4%), and clavicles (6.3%). It is notable that relatively larger number of positive hot uptakes were observed in the groups of post-WBBS and poor MS. The percentage of post-WBBS group over the total hot uptake lesions in upper and lower extremities, and spines were 51.0%, 43.8%, and 41.7%, respectively, while their percentages of AS were 2.73%, 1.1%, and 0%, respectively. The percentages of poor MS group in the upper and lower extremities, and spines were 10.4%, 17.4%, and 7.8%, respectively, while their percentages of AS were 26.7%, 14.2%, and 11.1%, respectively. There was a statistical difference in the percentage of AS between the groups of post-WBBS and poor MS (p=0.000). Conclusion : WBBS is a potential diagnostic tool in understanding the skeletal conditions of patients with head injuries which may be undetected during the initial assessment.

사후전산화단층촬영의 법의병리학 분야 활용을 위한 조건부 적대적 생성 신경망을 이용한 CT 영상의 해상도 개선: 팬텀 연구 (Enhancing CT Image Quality Using Conditional Generative Adversarial Networks for Applying Post-mortem Computed Tomography in Forensic Pathology: A Phantom Study)

  • 윤예빈;허진행;김예지;조혜진;윤용수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권4호
    • /
    • pp.315-323
    • /
    • 2023
  • Post-mortem computed tomography (PMCT) is commonly employed in the field of forensic pathology. PMCT was mainly performed using a whole-body scan with a wide field of view (FOV), which lead to a decrease in spatial resolution due to the increased pixel size. This study aims to evaluate the potential for developing a super-resolution model based on conditional generative adversarial networks (CGAN) to enhance the image quality of CT. 1761 low-resolution images were obtained using a whole-body scan with a wide FOV of the head phantom, and 341 high-resolution images were obtained using the appropriate FOV for the head phantom. Of the 150 paired images in the total dataset, which were divided into training set (96 paired images) and validation set (54 paired images). Data augmentation was perform to improve the effectiveness of training by implementing rotations and flips. To evaluate the performance of the proposed model, we used the Peak Signal-to-Noise Ratio (PSNR), Structural Similarity Index Measure (SSIM) and Deep Image Structure and Texture Similarity (DISTS). Obtained the PSNR, SSIM, and DISTS values of the entire image and the Medial orbital wall, the zygomatic arch, and the temporal bone, where fractures often occur during head trauma. The proposed method demonstrated improvements in values of PSNR by 13.14%, SSIM by 13.10% and DISTS by 45.45% when compared to low-resolution images. The image quality of the three areas where fractures commonly occur during head trauma has also improved compared to low-resolution images.

식염수-Sephadex가 $^{99m}TC$-Sephadex의 폐분포에 미치는 영향 (Effect of Saline-Sephadex on the Organ Distribution of $^{99m}TC$-Sephadex)

  • 성호경;강신구;고주환;문광남;이장규
    • 대한핵의학회지
    • /
    • 제5권2호
    • /
    • pp.57-64
    • /
    • 1971
  • The organ distribution study and the whole body scan were done in the albino rats at intervals of 5, 30, 60, 90 and 120 minutes after the intravenous injection of $^{99m}TC$-pertechnetate absorbed in Sephadex beads of $20{\sim}80$ micra in diameter. Effect of additional injection of physiological saline and saline absorbed in Sephadex beads of $20{\sim}80$ micra in diameter on the scan and organ distribution were also studied. The results were as follows. 1. Five minutes after the injection of $^{99m}TC$-pertechnetate absorbed in Sephadex beads of $20{\sim}80$ micra in diameter, Sephadex was well trapped in the lungs, with which the excellent lung scan was obtained. Two hours after the injection, kidneys were well visualized instead of lungs, which suggested that kidney acts as the excretory organ. Five minutes prior to scan, additional injection of physiological saline absorbed in Sephadex above mentioned was done. The bladder was also well visualized together with the kidneys. 2. In the distribution studies, most of radioactivity was detected in the lungs at 5 minutes and was gradually transferred chiefly to the kidneys and bladder and partly to the liver. 3. Additional injection of physiological saline resulted in a rapid transfer of $^{99m}TC$ trapped in the lung to both the kidneys and liver. 4. Additional injection of physiological saline absorbed in Sephadex beads of $20{\sim}80$ micra in diameter resulted in a rapid transfer of $^{99m}TC$ trapped in the lung to only the urinary system. 5. Results of these studies suggested that; a) Other nutrients and therapeutic compounds may be carried into the lungs along with Sephadex beads and then released in high concentration, which would exert greater therapeutic effect locally than that of the usual administration. b) Some radionuclides absorbed in Sephadex could be used as the lung scan agents, the flushing out of which by Sephadex-saline also give satisfactory renal and bladder scans. c) Other potent therapeutic radionuclides could be retained for some time by this method, which can be in the lungs easily flushed out within 2 hours.

  • PDF

한국 노인 여성을 위한 피트니스 압박웨어 치수 개발 (Development of a Sizing System of Women's Fitness Wear for the Senior Population in South Korea)

  • 전은진;이원섭;박장운;유희천
    • 한국의류산업학회지
    • /
    • 제20권4호
    • /
    • pp.464-473
    • /
    • 2018
  • The objective of this study is to develop a sizing system of fitness clothing that can properly accommodate various body sizes of Korean senior women. The sizing system of upper and lower fitness clothing was developed in the present study by selection of key variables, identification of size category candidates, and determination of an optimal sizing system. First, key anthropometric dimensions (stature and bust circumference for upper clothing and stature; waist circumference for lower clothing) were identified by factor analysis on the direct body measurements (n = 272) and 3D whole-body scan data (n = 271) of Korean senior women in Size Korea. Second, sizing system candidates based on the key dimensions of upper and lower clothing were explored using a grid method and an optimization method. Lastly, among the sizing system candidates, optimal sizing systems of upper and lower clothing were selected in terms of accommodation rate. Five size categories (short/small, short/medium, tall/small, tall/medium, and tall/large) were selected as the optimal sizing systems of upper and lower clothing with 89% and 78% of accommodation rate, respectively, for the Korean senior women. The anthropometric characteristics of the representative humans of the optimal size categories would be of use in the design of fitness compressive wear for the better fit and effectiveness of exercise and health of Korean senior women.

전신 뼈 검사에서 Wide Beam Reconstruction 기법의 유용성 (Utility of Wide Beam Reconstruction in Whole Body Bone Scan)

  • 김정열;강청구;박민수;박훈희;임한상;김재삼;이창호
    • 핵의학기술
    • /
    • 제14권1호
    • /
    • pp.83-89
    • /
    • 2010
  • UltraSPECT사의 Wide Beam Reconstruction (WBR)은 노이즈(Noise)와 조준기의 광속 확산 함수 효과(Beam spread function effect)를 제거하고 환자와의 거리를 자동적으로 보상하여 높은 해상도와 대조도를 제공할 수 있어 영상 획득 시간을 짧게 할 수 있고 상당한 영상 질 향상에 도움을 준다고 보고되고 있다. 이에 본 연구에서는 핵의학 분야에서 가장 흔히 이용되는 전신 뼈 스캔에 대해 WBR의 임상적 적용에 대한 유용성을 알아보고자 한다. XpressBone (WBR)의 성능 실험을 위하여 NEMA에서 제공하는 방법에 의하여 선원(Line source)과 SPECT Phantom을 이용하여 공간 분해능을 측정 분석하였다. 실험방법은 선원의 총 계수치를 200 kcps에서 300 kcps로 변화시켜 측정하였으며, SPECT Phantom은 매트릭스 크기를 변화시켜 측정하여 공간분해능에 대한 분석을 하였다. 또한 2009년 1월부터 2009년 9월까지 본원을 내원하여 뼈 스캔을 시행 받은 환자 40명을 두 군으로 나누어 임상 연구를 시행하였다. 1군은 $^{99m}Tc$-HDP 740 MBq (20mCi)를 투여하고 검사속도(20, 30 cm/min)를 변화시켰고, 2군은 동일한 검사속도에서 $^{99m}Tc$-HDP의 투여량을 변화시켜 영상을 획득하여 Standard data와 WBR기법으로 재구성한 영상을 비교 평가하였다. 분석방법은 대퇴골체부에서 뼈와 연부조직간 섭취비(Femur to tissue ratio: FTR)를 측정한 정량적인 분석과 핵의학과 전문의와 5년 이상의 실무경험을 가진 방사선사가 육안적인 분석을 하여 비교 평가하였다. 성능 실험에서 선원을 사용하여 실험한 결과 Planar WBR data는 Standard data에 비하여 분해능이 약 10% 향상되었으며, WBR 반치폭(Full-Width at Half-Maximum)은 16% 향상되었다(Standard data 8.45, WBR data 7.09). SPECT Phantom에서는 약 50%의 분해능이 향상되었으며, WBR 반치폭은 50% 향상되었다(Standard data 3.52, WBR data 1.65). 임상 연구에서는 $^{99m}Tc$-HDP 투여량을 고정시키고 검사속도를 20cm/min과 30 cm/min로 변화시킨 1군에서 Standard data와 WBR data의 전신 뼈 스캔 전면 영상에서 뼈 대비 연부조직간 섭취비는 통계적으로 유의한 차이를 보이지 않았다 (p=0.07). 검사속도를 고정하고 $^{99m}Tc$-HDP 투여량을 변화시킨 2군에서는 Standard data와 WBR data간의 전신 뼈 스캔전면 영상에서는 통계적으로 유의한 차이를 보이지 않았다 (p=0.458). 영상의 육안적 분석에서도 두 군 간 유의한 차이를 보이지 않았다(p>0.05). NEMA test 결과 WBR 기법의 영상에서 분해능이 향상되는 결과를 나타내었고, 임상 실험에서는 기존 재구성 방법에서의 동일한 해상도를 가지면서도 검사시간을 단축시킬 수 있었으며 방사성의약품의 투여량도 줄일 수 있었다. 이미 알려진 바와 같이 WBR은 노이즈를 감소시켜 신호 대 잡음비를 증강시키는 새로운 영상 재구성 방법임을 확인 할 수 있으며 동일한 검사속도에서 투여량을 감소시킬 수 있어 수신자의 피폭선량 경감과 검사시간을 단축할 수 있었으며 임상 현장에서 유용하게 이용되리라 사료된다.

  • PDF

전신 PET/CT 영상에서 조영제 영향의 보정 유.무에 따른 SUV 평가 (The Evaluation of SUV Using with and without Correction for Effect of Contrast Media in Whole Body PET/CT Imaging)

  • 남소라;손혜경;임한상;박훈희;조효민;이창래;김희중
    • 한국의학물리학회지:의학물리
    • /
    • 제17권4호
    • /
    • pp.246-251
    • /
    • 2006
  • 본 연구의 목적은 전신 PET/CT영상에서 조영제의 영향에 대한 보정 유 무가 SUV (standard uptake value)에 미치는 영향을 평가하는 것이었다. 영상획득은 GE DSTe PET/CT 시스템을 사용하였으며, 간질환(hepatocellular carcinoma, HCC)과 신장질환(renal cell carcinoma, RCC)이 있는 환자를 대상으로 하여 영상을 평가하였다. 영상 평가는 조영제에 의한 영향을 보정한 영상과 보정하지 않은 영상에서 각각 동일한 위치에 같은 크기의 관심영역을 설정한 후 각 관심영역으로부터 구한 SUV를 비교함으로써 수행하였다. HCC 환자의 경우 조영제에 의한 영향의 보정 유 무에 따른 평균 SUV의 차이는 $1.5{\pm}1.2%$이었고, 최대 4.3%의 SUV 차이를 나타내었다. RCC 환자의 경우 평균 SUV의 차이는 $1.0{\pm}0.9%$이었고, 최대 1.9%의 SUV 차이를 나타내었다. 조영제를 사용한 PET/CT 영상에서 조영제에 의한 영향을 보정하지 않았을 경우는 조영제에 의한 영향을 보정해준 경우에 비해 상대적으로 높은 SUV를 나타내었다. 본 연구의 결과는 HCC 환자와 RCC 환자의 경우 조영제에 의한 영향을 보정한 경우와 보정하지 않은 경우 SUV에 큰 차이를 보이지는 않았으나, 향후 보다 많은 수의 HCC 환자와 RCC 환자를 대상으로 한 추가적인 연구가 필요할 것이라고 생각한다. 또한 다른 질환을 가진 환자의 경우에 대해서도 조영제가 SUV에 미치는 영향을 평가하는 것은 매우 유용하리라 생각한다.

  • PDF

최소 거리 기반 가중치 이분 분할 매칭 방법을 이용한 3차원 영상 정합 (3D Image Mergence using Weighted Bipartite Matching Method based on Minimum Distance)

  • 장택준;주기세;장복주;강경영
    • 한국항행학회논문지
    • /
    • 제12권5호
    • /
    • pp.494-501
    • /
    • 2008
  • 본 논문에서는 구조화된 격자 패턴 발생기를 이용하여 카메라 시야로부터 가려진 인체의 완전한 3차원 정보를 정합하기 위하여 턴테이블 위에 놓인 인체를 4방향에서 영상을 획득한 후 각 영상을 정합하는 새로운 알고리즘을 소개한다. 다각형 망으로 표시된 정합될 두 영상은 3차원 좌표 값의 급격한 변화가 없고 주사 방향이 한 방향이기 때문에 좌표축에 따라 가중치가 다른 최소 거리 기반 가중치 이분 분할 매칭 법을 사용하여 정합한다. 완전한 3차원 체형 정보를 획득하기 위하여, 획득한 영상이 4개이기 때문에 이런 과정들을 3번 반복한다. 제안된 방법은 기존의 분지 한정법, 동적 계획법, 헝가리언 법에 비해 매칭 정확도는 조금 낮지만 탐색 시간을 200 - 300% 줄일 수 있는 장점이 있다.

  • PDF

전신 PET/CT 영상 획득 프로토콜을 이용한 유효선량 평가 (Effective Dose Evaluation using Clinical PET/CT Acquisition Protocols)

  • 남소라;손혜경;이상훈;이창래;조효민;김희중
    • 한국의학물리학회지:의학물리
    • /
    • 제17권3호
    • /
    • pp.173-178
    • /
    • 2006
  • 본 연구는 임상 환경에서의 전신 PET/CT 영상 획득방식 조건에서 환자가 받는 피폭선량을 Alderson 팬텀과 TLD를 이용하여 측정하는 것이었다. Philips GEMINI PET/CT에서는 $^{137}Cs$ 투과 스캔과 이와의 비교를 위한 고화질 CT 투과 스캔 및 토포그램을 각각 수행하여 각 인체 장기별 선량을 측정하였다. GE DSTe PET/CT에서는 감쇄 보정용 CT투과 스캔과 진단용 전신 CT스캔 및 토포그램 그램을 각각 수행하여 인체 내 장기별 선량을 측정하였다. 여기서 각 인체 장기는 ICRP 60에서 추천하는 장기를 참고로 선택하였다. 또한 실험에 사용한 TLD는 10 MV X선을 사용하여 교정한 후 5% 이내의 정확도를 가지는 것만 사용하였다. 그 결과 Philips GEMINI PET/CT에서의 $^{137}Cs$ 선원을 이용한 투과 스캔의 유효선량은 $0.14{\pm}0.950mSv$, 고화질 CT투과 스캔에서의 유효선량은 $29.49{\pm}1.508mSv$, 토포그램에서의 유효선량은 $0.72{\pm}0.032mSv$로 나타났다. 또한 GE DSTe PET/CT에서 감쇄보정용 CT투과 스캔의 유효선량은 $20.06{\pm}1.003mSv$, 진단용 전신 CT스캔의 유효선량은 $24.83{\pm}0.805mSv$, 토포그램의 유효선량은 $0.27{\pm}0.008mSv$로 나타났다. 임상 환경에서의 PET/CT 영상을 획득했을 시 종합 피폭은 PET영상을 획득했을 때의 유효선량을 더함으로써 평가할 수 있었다. 그 결과 Philips GEMINI PET/CT (Topogram+$^{137}Cs$ transmission scan + PET, Topogram +high Quality CT+ PET)와 GE DSTe PET/CT (Topogram+CT attenuation map+PET, Topogram+CT for diagnosis+PET)에서 환자가 받는 총 유효선량들은 각각($7.65{\pm}0.951mSv$$37.00{\pm}1.508mSv$), ($27.12{\pm}1.003mSv,\;31.89{\pm}0.805mSv$)로 나타났다. PET/CT 영상 획득 시에 가능한 한 피폭은 적게 하면서도 진단이 가능한 화질을 유지할 수 있는 최적의 프로토콜 마련이 시급한 것으로 생각된다.

  • PDF

갑상선암 환자에서 방사성옥소 진단스캔과 치료 후 스캔의 비교 및 임상경과 (Comparison of Diagnostic and Post-therapy Radioiodine Scan in Well-Differentiated Thyroid Cancer and the Clinical Outcome)

  • 이석모;배상균;염하용
    • 대한핵의학회지
    • /
    • 제34권1호
    • /
    • pp.22-29
    • /
    • 2000
  • 목적: 방사성옥소 치료를 받은 갑상선암 환자의 수술 후 첫 진단 스캔과 치료 후 스캔을 비교하고 치료 후 스캔에서 더 많은 병소를 보이는 경우(불일치군)와 같은 경우(일치군) 사이에 임상경과에 차이가 있는 지를 알아보았다. 대상 및 방법: 방사성옥소 치료를 받은 분화된 갑상선암 환자 143명의 수술 후 첫 진단 스캔과 치료 후 스캔을 비교하였다. 진단 스캔은 방사성옥소 185 MBq를, 치료후 스캔은 $3.7{\sim}9.3$ GBq를 투여한 후 얻었다. 추적 진단 스캔에서 비정상 섭취가 없으며 혈청 갑상선글로불린치가 정상이면 잔여 갑상선조직이 제거된 것으로 판정하였다. 결과: 두 스캔사이에 차이를 보인 경우는 143명 중 25명(17.5%)으로, 진단 스캔보다 치료 후 스캔에서 더 많은 병소를 보인 경우가 22명(15.4%), 기절효과를 보인 경우가 3명(2.1%)이었다. 원격전이가 확인된 환자 14명 중 9명(64.3%)은 치료 후 스캔에서만 병소를 확인할 수 있었다. 기절 효과를 보인 3명 중 1명은 아치사손상에 의한 것으로 생각되나, 나머지 2명에서는 다음 진단 스캔에서도 보이지 않아 진단 스캔 용량에 의한 제거의 가능성을 보였다. 관해는 75명(58.1%)의 환자에서 이루어졌다. 잔여 갑상선의 제거율, 평균 방사성옥소 축적 용량은 불일치군과 일치군 사이에서 유의한 차이가 없었다. 결론: 185 MBq의 단일 용량의 방사성옥소를 이용하여 진단 스캔을 얻었을 때, 진단 스캔과 치료 후 스캔이 다른 경우는 17.5%에서 관찰되었으며, 특히 원격전이가 확인된 환자의 64.3%는 치료 후 스캔에서만 병소가 확인되었다. 진단 스캔과 치료 후 스캔 사이에 차이를 보인 환자군과 일치한 환자군에서 잔여 갑상선 제거율 및 방사성옥소 평균 축적용량은 유의한 차이가 없었다. 기절효과를 보인 병소는 추적검사에서 모두 제거되어 방사성옥소를 섭취할 능력의 일시적 장해뿐 아니라 진단용량에 의한 치료효과도 있었던 것으로 생각된다.

  • PDF

항과립구 항체 골수스캔을 이용한 다발성 골수종 병변의 평가: 단순골X-선점사 및 골스캔과의 비교 (Bone Marrow Scintigraphy with Antigranulocyte Antibody in Multiple Myeloma: Comparison with Simple Radiography and Bone Scintigraphy)

  • 김동환;이재태;백진호;정진태;현동우;천경아;이영학;손상균;송홍석;이규보
    • 대한핵의학회지
    • /
    • 제32권4호
    • /
    • pp.354-364
    • /
    • 1998
  • 목적: 단순골X-선검사와 골스캔은 다발성 골수종 병변의 조기검출에 많은 제한점을 가진다. 본 연구는 다발성 골수종에서 방사능 표지 항백혈구항체를 이용한 골수스캔의 유용성을 평가하기 위해 실시되었다. 대상 및 방법: 다발성 골수종 환자 22례의 경우 남녀비는 2.1:1이었고 중간연령은 57세였으며, Stage II는 3례, Stage III는 19례였다. 골수스캔은 $^{99m}Tc$으로 표지된 항백혈구 항체를 이용하여 전신상을 촬영하였고, 그 결과를 단순골X-선검사 및 골스캔과 부위별로 비교하였다. 결과: 단순골X-선검사는 14명(64%), 골스캔에서는 11명(50%)의 환자에서 병변을 검출한 반면, 골수스캔에서는 19명(86%)의 환자에서 국소결손병변을 검출하였다. 골수스캔은 Stage II에서는 33%의 환자(1/3)에서 병변을 검출하였고, Stage III에서는 90%의 환자(17/19)에서 병변을 검출하였다. 골수스캔에서 골수확장의 소견은 68% (15/22)에서 관찰되었다. 전체환자 22명에서 124개의 국소결손병변이 단순골X-선 검사, 골스캔, 골수스캔에서 검출되었는데, 단순골X-선검사는 58개 병변을, 골스캔은 40개 병변을 검출한 반면 골수스캔을 통해서는 92개 병변을 검출하였고, 단순골X-선검사나 골스캔에서는 검출하지 못한 국소결손병변을 51개나 더 검출할 수 있었으며, 이는 특히 새로운 흉요추 국소결손병변의 검출에 도움이 되었다. 결론: 골수스캔은 단순골X-선검사나 골스캔보다 높은 검출율을 보였고, 흉요추병변의 검출에 많은 도움을 줄 수 있는 것으로 생각된다. 또한 골수스캔은 진행한 병기에서 더 높은 검출율을 보여주어 골수스캔소견과 임상적 병기간에 상관성을 가지는 것으로 생각된다. 다발성 골수종에서의 골수스캔은 새로운 병변의 검출뿐만 아니라 병기정도의 평가에 도움이 될 것으로 판단된다.

  • PDF