• Title/Summary/Keyword: White-Metal

Search Result 228, Processing Time 0.034 seconds

Growth Performance and Nutrient Composition in the White-spotted Flower Chafer, Protaetia brevitarsis (Coleoptera: Scarabaeidae) Fed Agricultural By-product, Soybean Curd Cake (비지박 첨가 먹이원 급여에 따른 흰점박이꽃무지 유충의 생육과 영양성분 변화)

  • Song, Myung-Ha;Han, Moon-Hee;Lee, Seokhyun;Kim, Eun-Sun;Park, Kwan-Ho;Kim, Won-Tae;Choi, Ji-Young
    • Journal of Life Science
    • /
    • v.27 no.10
    • /
    • pp.1185-1190
    • /
    • 2017
  • Insects are gaining recognition as an alternative source of protein. As a result, more and more domestic farms have begun mass rearing of edible insects. In order to produce high quality insects, studies on the development of safe and nutritious feed sources are needed. Given the cost of rearing insects, agricultural and industrial by-products are good sources for feed. The efficient utilization of these by-products can help in reducing the cost of production and preventing environmental pollution. In the current study, Citrus unshiu peel (CP), soybean curd cake (SCC), soybean oil meal (SOM), and brewers dried grain (BDG) were investigated for their effects on larval growth and development of Protaetia brevitarsis. Interestingly, the feed with 10% SCC increased larval weight by 3.5 times. For the larval period, the group of 10% SCC was significantly shorter than the control. Furthermore, minerals such as Zn, Ca, K, Mg, Na, and P were recorded to be high in 10% SCC. A total of 17 amino acids were present in 10% SCC, of which tyrosine and arginine were predominant. The heavy metal contents were very small amounts or not detected in any of the investigated groups. These findings provided a scientific basis for the utilization of soybean curd cake as a nutritional feed source to promote larval growth and produce quality insects.

AN EXPERIMENTAL STUDY ON THE MICROHARDNESS OF DENTAL AMALGAMS (치과용 아말감의 미세경도에 관한 실험적연구)

  • Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.8 no.1
    • /
    • pp.89-96
    • /
    • 1982
  • The purpose of this study is to identify the phases of four different types, low-copper lathe cut (Type II, class 1) and spherical (Type II, class 2) amalgam alloys which are made by Caulk company and high copper Dispersalloy (Type II, class 3) made by Johnson & Johnson and Tytin (Type I, class 2) made by S.S. White and to determine the Vickers hardness number on the individual phase and four different types of dental amalgam. After each amalgam alloy and Hg measured exactly by the balance was triturated by the mechanical amalgamator (De Trey), the triturated mass was inserted into the cylindrical metal mold which was 4 mm in diameter and 12mm in height and was pressed by the Instron Universal Testing machine (Model 1125) at the speed of 1mm/minute with 143$kg/cm^2$ according to the A.D.A. Specification No. 1. The Specimen removed from the mold, mounted and stored in the room temperature for 7 days. The speciman was polished with the emery paper from #220 to #1200 and finally on the polishing cloth with 0.3 and 0.05 um $Al_2O_3$ powder suspended in water. And then each specimen was etched by Allan's method and washed with Sodium Bisulfinite for 30 seconds. Finally differentiation and metallography on each phase were obtained by using metallographical microscope (Versamet, Union) and microhardness was obtained by using microhardness tester (MVH-2, Torsee). The results were as follows: 1. In the low-copper amalgam, the ${\gamma}$, ${\gamma}_1$ and ${\gamma}_2$ phase were observed and in the high-copper amalgam, the ${\gamma}$, ${\gamma}_1$. ${\epsilon}$ and ${\eta}$ phases were observed but ${\gamma}_2$ phase was not observed. 2. Among the microhardness of each amalgam phase measured under pressing a vickers diamond indenter with 2.0gm load for 30 seconds, e phase has the highest V.H.N (314 ${\pm}$ 20), and in low-copper amalgam 12 phase has the lowest V.H.N. (29${\pm}$1) and ${\eta}$ phase which was observed in high-copper amalgam has 230${\pm}$13 V.H.N and this phase is considerd to contribute to strengthen the handness in amalgam. 3. The V.H.N. measured under pressing a Vickers diamond indenter with 300.0gm load for 30 seconds in low-copper amalgam was lower than that of high-copper amalgam.

  • PDF

Quilitative certificational plan of shanyao (산약(山藥)의 품질인증(品質認證) 방안(方案))

  • Cho, Eun-Hawn;Roh, Seong-Soo;Kil, Ki-Jeong;Seo, Bu-il;Seo, Young-Bae
    • Journal of Haehwa Medicine
    • /
    • v.13 no.2
    • /
    • pp.187-196
    • /
    • 2004
  • Now many sustitution and false articles is used in korea instead of shanyao. To use shanyao correctly, we will make a quilitative certificational plan of shanyao to investigate all of lieraturea, records and documents. And we could reach conclusions as folloews. 1) Source About a source of shanyao, though korea and china has a each other source, we think there is no problem in use of both. 2) Process In our country producing shanyao as medical use is a 'duanma', we can divide into peeling and non-peeling, drying at bulks and at briquets, steaming shanyao and fresh shanyao. Regardless of existence for peeling and steaming, a distributing shanyao is received a proper judgment. Like this result was expressed by insufficiency of standards about medical components or indicating components. We detected a reminding S02 more than 10 ppm. And this expresses that there ia a problum at a drying method. To suggest proper processing methods, a standard of quility will have to be made which the existence of peeling, difference of quility between 'changma' and 'duanma', drying method and exudation test with cutted thickness are adaptable. Besides, 'maoshanyao' and 'guangshanyao' of china is processed by various methods which decrease a medical effect such as too much soaking shanyao in water, steaming with a sulfur, too much peeling, So we must process shanyao like the next methods. (1) When harvesting, dig deeply not to cut off roots. (2) Not to peel, wash shanyao in a washing machine. (3) Dry to 50-60% degree at sunny place or drying machine. (4) To be easy for drying and exudation, cut off a thick piece with 5 mm (5) Dry perfectly at ding machine. 3) Quality3) Quality (1) Functional standards It is not Proper that 'guangshanyao' is used in china because it has a problem with quility on process of working, If they did not soak shanyao in water or heat with steam, it is the real situation that they cannot cutt off shanyao evenly. In conclusion, shanyao must be heavy, powdery with a perfectly non-peeling surface, section surface is yellow-white color, unequal and has no holes. (2) Physicochemical standards It is the real situation that we can not distinguish into quility of shanyao with established test because various workings which decrease medical effects is used. Therefore we suggest a testing standard of S02 which is used in bleaching. And testing standards relatived with decrease of medical effects must be established at once. It must that Dry on loss is less than 14.0%, content of ash is less than 6.0%. Content of acid-nonsoluble ash is less than 0.5%. Contens of heavy metal has to detect less than 30 ppm and there is no reminding agricultural medince.

  • PDF

Carbonization Patten and Operation Characteristics of a 1Φ 2 W MCCB Damaged by PCITS (PCITS에 의해 소손된 1Φ 2 W MCCB의 탄화 패턴 및 작동 특성)

  • Lee, Jae-Hyuk;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.28 no.5
    • /
    • pp.8-13
    • /
    • 2014
  • The purpose of this study is to analyze the damage pattern when overcurrent is applied to a thermal magnetic type molded case circuit breaker (MCCB) using a Primary Current Injection Test System (PCITS). When an overcurrent of 150 A was applied to the PCITS for 5 seconds with the trip bar of an MCCB being damaged, it was found that the surface of the temperature control device (bimetallic strip) positioned at the right was significantly carbonized. When an overcurrent of 300 A was applied to the PCITS for 5 s under the same conditions, the entire temperature control device was deteriorated, becoming flattened and in close contact with the MCCB. When an overcurrent of 450 A was applied to the PCITS for 5 s, the coil of the temperature control device was melted and disconnected. In addition, it was observed that the contacts, the enclosure and upper cover were deformed and there was a trace of carbonization on them. When approximately 3 s had elapsed after an overcurrent of 600 A was applied, white smoke occurred inside the MCCB and a flame was radiated out, after which the overcurrent supply stopped with "phutt" (whomp) sound. It was observed that when the same type of MCCB is damaged by a general flame, the surfaces of its handle, terminal, arc divider (extinguisher) and temperature control device were carbonized uniformly. In addition, it was found that the trip bar of the operating mechanism was melted down and the metal operation pin was moved while being tripped.

Weldability with Process Parameters During Fiber Laser Welding of a Titanium Plate (I) - Effect of Type and Flow Rate of Shielding Gases on Weldability - (티타늄 판재의 파이버 레이저 용접시 공정변수에 따른 용접특성 (I) - 실드가스 종류 및 유량에 따른 영향 -)

  • Kim, Jong Do;Kim, Ji Sung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.12
    • /
    • pp.1047-1053
    • /
    • 2016
  • In this study, welding of pure titanium was carried out by using a continuous wave fiber laser with a maximum output of 6.3 kW. Because brittle regions form easily in titanium as a result of oxidation or nitriding, the weld must be protected from the atmosphere by using an appropriate shielding gas. Experiments were performed by changing the type and the flow rate of shielding gases to obtain the optimal shielding condition, and the weldability was then evaluated. The degree of oxidation and nitriding was distinguished by observing the color of beads, and weld microstructure was observed by using an optical microscope and a scanning electron microscope. The mechanical properties of the weld were examined by measuring hardness. When the weld was oxidized or nitrified, the bead color was gray or yellow, and the oxygen or nitrogen content in the bead surface and overall weld tended to be high, as a result of which the hardness of the weld was thrice that of the base metal. A sound silvery white bead was obtained by using Ar as the shielding gas.

EXPERIMENTAL STUDY ON THE DISSOLUTION COMPONENTS AND CORROSION PRODUCTS OF SEVERAL AMALGAMS IN ARTIFICIAL SALIVA (인공타액에서 수종 아말감의 부식시 용해성분 및 표면 부식 생성물에 관한 실험적 연구)

  • Cho, Seung-Joo;Lee, Myung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.19 no.1
    • /
    • pp.1-26
    • /
    • 1994
  • The purpose of this study was to investigate the dissolution components during corrosion of amalgams and to identify surface corrosion products in the modified Fusayama artificial saliva. Four type of amalgam alloys were used: low copper lathe cut amalgam alloy (Cavex 68), low copper spherical amalgam alloy (Caulk Spherical Alloy), high copper admixed amalgam alloy (Dispersalloy) and high copper single composition amalgam alloy (Tytin). Each amalgam alloy and Hg were triturated according to the manufacturer's direction by means of mechanical amalgamator (Capmaster, S.S.White), and then the triturated mass was inserted into the cylindrical metal mold which was 10mm in diameter and 2.0mm in height and condensed with compression of 150kg/$cm^2$ using oil pressor. The specimens were removed from the mold and stored at room temperature for 7 days and cleansed with distiled water for 30 minutes in an ultrasonic cleaner. The specimens were immersed in the modified Fusayama artificial saliva for the periods of 1 month, 3 months and 6 months. The amounts of Hg, Cu, Sn and Zn dissolved from each amalgam specimen immersed in the artificial saliva for the periods of 1 month, 3 months and 6 months were measured using Inductivity Coupled Plasma Atomic Emission Spectrometry (ICPQ-1000, Shimadzu, Japan) and amount of Ag dissolved from amalgam specimen was measured using Atomic Absorption Spectrophotometry (Atomic Absorption/Flame emission spectrophotometer M-670, Shimadzu, Japan). A surface corrosion products of specimens were analysed using Electron Spectroscopy Chemical Analyser (ESCA PHI-558, PERKIN ELMER, U.S.A.). The secondary image and back scattered image of corroded surface of specimens was observed under the SEM, and the corroded surface of specimens was analysed with the EDX. The following results were obtained. 1. The dissolution amount of Cu was the most in high copper admixed amalgam(Dispersalloy) and the least in high copper single composition amalgam(Tytin). 2. Sn and Zn were dissolved during all the experiment periods, and dissolution amounts were decreased as the time elapsed. 3. Initial surface corrosion products were ZnO and SnO. 4. Corrosion of ${\gamma}$ and ${\gamma}_2$ phase in low copper amalgams was observed and Ag-Cu eutectic alloy phase was corroded in low copper spherical amalgam(Caulk Sperical Alloy). 5. Corrosion of ${\gamma}$ and $\eta$' phase in high copper amalgams was observed and Ag-Cu eutectic alloy phase was corroded in high copper admixed amalgam(Dispersalloy). 6. Sn-Cl was produced in the subsurface of low copper amalgams and high copper admixed amalgam.

  • PDF

A Study on Gilded Ornamental Shoes Excavated from Beopcheon-ri, Wonju (원주(原州) 법천리출토(法泉里出土) 금동식리(金銅飾履)에 대한 연구(硏究))

  • Kwon, Hyuk-nam;Yu, Hei-sun
    • Conservation Science in Museum
    • /
    • v.3
    • /
    • pp.65-69
    • /
    • 2001
  • Scientific analysis are carried on gilded ornamental shoes, which have been excavated from tomb No 1. and No 4. in Beopcheon-ri, Wonju dated from Baekje Period. This object is a very important because it provides valuable information on the development of metal-making techniques of that period. Thus, this article illustrates the investigation conducted to reveal how the object was created using what materials and techniques. Instead of the spikes-attached to the bottom plate of the object-that couldn't be sampled, a sample of a decorative rivet showing a similar structure to the spikes-attached to the other parts of the shoes-was prepared for a cross-section examination. Using radiography and microscopes, it was found that the head of a spike was placed and then punched to the gilded plate, so it can be held to the shoes. Under the SEM-EDS, the cross-section of the rivet shows that the gilding layer was applied before the attachment of the rivets. It also shows that the gilding layer is distributed unevenly and there are empty spaces indicating amalgam gilding was employed. This was confirmed as Mercury was detected on the SEM-EDS analysis of the object. The examination of the microstructure of the plate using the SEM-EDS revealed that the object is made of a single copper alloy plate with recrystallized twining and non-metallic white inclusions, which found to be lead in this case.

Growth and Phytochemicals of Lettuce as Affected by Light Quality of Discharge Lamps (방전램프의 광질에 따른 상추의 생장 및 파이토케미컬 분석)

  • Lee, Jae Su;Nam, Sang Woon;Kim, Yong Hyeon
    • Journal of Bio-Environment Control
    • /
    • v.22 no.4
    • /
    • pp.400-407
    • /
    • 2013
  • This study was performed to analyze the effect of light quality of discharge lamp on growth and phytochemicals contents of lettuce (Lactuca sativa L. cv. Jeokchima) grown under metal halide (MH) lamp, high-pressure sodium (HPS) lamp, and xenon (XE) lamp in a plant factory. Cool-white fluorescent (FL) lamp was used as the control. Photoperiod, air temperature, relative humidity, $CO_2$ concentration, and photosynthetic photon flux (PPF) in a plant factory were 16/8 h (day/night), $22/18^{\circ}C$, 70%, 400 ${\mu}mol{\cdot}mol^{-1}$, and 200 ${\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, respectively. MH lamp had the greatest fraction of blue light (400-500 nm) of 23.0%. However, HPS lamp had the lowest fraction of 4.7% for blue light and the greatest fraction of 38.0% for red light (600-700 nm). At 11 and 21 days after transplanting, leaf length, leaf width, leaf area, shoot fresh weight, and shoot dry weight of lettuce as affected by the light quality of the discharge lamp were significantly different. The leaf area of lettuce grown under HPS, MH, and XE lamp increased by 45.7%, 16.3%, and 9.5%, respectively, as compared to the control. These results were similar for shoot fresh weight. Growth characteristics of lettuce grown under HPS lamp increased since HPS lamp had more fraction of red light. However, growth of lettuce grown under MH and XE lamp decreased since they had more fraction of blue light. As compared to the control, the ascorbic acid in lettuce leaves grown under discharge lamp decreased. The greatest anthocyanins accumulation of 0.70 mg/100 g was found at MH treatment. Anthocyanins content in lettuce leaves grown under XL and HPS lamp were 79.3% and 8.6%, respectively, compared with the control. Growth and phytochemicals contents of lettuce were highly affected by the different spectral distribution of the discharge lamp. These results indicate that the combination of discharge lamp or LED lamp for enhancing the light quality of discharge lamps is required to increase the growth and phytochemicals accumulation of lettuce in controlled environment such as plant factory.

Analysis by Bat Symbol of Paintings and Crafts in late-Joseon Period: Focused on museum collections (조선후기 박쥐상징 회화와 공예품의 분석-박물관 소장품을 중심으로)

  • Eom, So-Yeon
    • KOMUNHWA
    • /
    • no.69
    • /
    • pp.41-62
    • /
    • 2007
  • This thesis is focused on the bat symbol, especially prevalent crafts’ pattern in late Joseon period on museum collections. For the use and reperception of them, I am aimed for appropriate analysis of bat symbol by co connotation which reflects the characteristics on number.plastic.color symbol. This point of view, bat idea and bat paintings in Joseon period will be the source of meanings to the denotation of bat patterns. In the museum collections, bat paintings and patterns are calculated 324 objects. By functional classification, the bat patterns on dwelling-crafts for the royal and for the people will be discussed. In result, the bat paintings were only a few, however, usually connoted Taoist hermit with super-natural powers.longevity.protector of Lightning-God.praying for long life, which were based on Taoism. Meanwhile the bat symbol of dwelling-crafts for the royal projected the longevity and prosperity of king and queen. By he Five Blessings and good auspices in Ching dynasty, number of '5.4' implied 'Five Blessings', Through the correct recognition of homo-phone, "a bat(蝠, fu)=happiness(福, fu)$\rArr$five bats(五蝠)$\rArr$Five Blessings(五福 )." In the case of bat symbol on the dwelling-crafts for the people, especially its for women, it expressed on the metal-decoration of furniture and paper-crafts. In the metal-decoration, the signified of bat symbol were expellant-evil('guard') that of characteristic signifier, white-silver color, number '1' and 'flying-type'. The bat symbol on paper-crafts for the people signified 'double happiness'.harmony.sons with number of '2', 'Five Colors' and the transformation of 'flying-type'. Accordingly, the bat symbol on the dwelling-crafts for the people marked 'happiness and guard', because the people had concrete cognition the bat symbol as a denotation of 'happiness and 'guard' by itself

  • PDF

Ex vivo Morphometric Analysis of Coronary Stent using Micro-Computed Tomography (미세단층촬영기법을 이용한 관상동맥 스텐트의 동물 모델 분석)

  • Bae, In-Ho;Koh, Jeong-Tae;Lim, Kyung-Seob;Park, Dae-Sung;Kim, Jong-Min;Jeong, Myung-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.2
    • /
    • pp.93-98
    • /
    • 2012
  • Micro-computed tomography (microCT) is an important tool for preclinical vascular imaging, with micron-level resolution. This non-destructive means of imaging allows for rapid collection of 2D and 3D reconstructions to visualize specimens prior to destructive analysis such as pathological analysis. Objectives. The aim of this study was to suggest a method for ex vivo, postmortem examination of stented arterial segments with microCT. And ex vivo evaluation of stents such as bare metal or drug eluting stents on in-stent restenosis (ISR) in rabbit model was performed. The bare metal stent (BMS) and drug eluting stent (DES, paclitaxel) were implanted in the left or right iliac arteries alternatively in eight New Zealand white rabbits. After 4 weeks of post-implantation, the part of iliac arteries surrounding the stent were removed carefully and processed for microCT. Prior to microCT analysis, a contrast medium was loaded to lumen of stents. All samples were subjected to an X-ray source operating at 50 kV and 200 ${\mu}A$ by using a 3D isotropic resolution. The region of interest was traced and measured by CTAN analytical software. Objects being exposed to radiation had different Hounsfield unit each other with values of approximately 1.2 at stent area, 0.12 ~ 0.17 at a contrast medium and 0 ~ 0.06 at outer area of stent. Based on above, further analyses were performed. As a result, the difference of lengths and volumes between expanded stents, which may relate to injury score in pathological analysis, was not different significantly. Moreover, ISR area of BMS was 1.6 times higher than that of DES, indicating that paclitaxel has inhibitory effect on cell proliferation and prevent infiltration of restenosis into lumen of stent. And ISR area of BMS was higher ($1.52{\pm}0.48mm^2$) than that of DES ($0.94{\pm}0.42mm^2$), indicating that paclitaxel has inhibitory effect on cell proliferation and prevent infiltration of restenosis into lumen of stent. Though it was not statistically significant, it showed that the extent of neointema of mid-region of stents was relatively higher than that of anterior and posterior region in parts of BMS as showing cross-sectional 2-D image. suggest that microCT can be utilized as an accessorial tool for pathological analysis.