• Title/Summary/Keyword: White Plume

Search Result 13, Processing Time 0.025 seconds

An Experimental Study on the Cooling Tower of Plume Prevention and Performance Improvements (냉각탑 백연방지의 성능 향상에 관한 실험적 연구)

  • JEONG, SOON YOUNG;LEE, BYEONG CHEON;KIM, SUNG
    • Journal of Hydrogen and New Energy
    • /
    • v.30 no.6
    • /
    • pp.578-584
    • /
    • 2019
  • The occurrence of white plume in the cooling tower is phenomenon that the steam in the air through the cooling tower fan is condensed again by the cold ambient air to become saturated moist air. Accordingly, this can cause many problems like spoiling landscape around the cooling tower, odor of ambient air, falling accident by frozenness in the winter, and traffic accident, etc. This study was to install the heat exchanger in the inside of the cooling tower in order to prevent the white plume phenomenon in the cooling tower without affecting the performance of cooling tower. In addition, this study was to discharge the part of cooling water into the atmosphere through the recirculation of heat exchanger after creating dry air by heating the saturated moist air to the dew point temperature. At that time, this study was to conduct the experimental study in order to secure the optimal design data to prevent the white plume in the cooling tower because it checked the dry·moist temperature and relative humidity in the inside·outside of cooling tower on the moist air, and evaluated the performance of the heat exchanger.

Effect of Flue Gas Heat Recovery on Plume Formation and Dispersion

  • Wu, Shi Chang;Jo, Young Min;Park, Young Koo
    • Particle and aerosol research
    • /
    • v.8 no.4
    • /
    • pp.161-172
    • /
    • 2012
  • Three-dimensional numerical simulation using a computational fluid dynamics (CFD) was carried out in order to investigate the formation and dispersion of the plume discharged from the stack of a thermal power station. The simulation was based on the standard ${\kappa}{\sim}{\varepsilon}$ turbulence model and a finite-volume method. Warm and moist exhaust from a power plant stack forms a visible plume as entering the cold ambient air. In the simulation, moisture content, emission velocity and temperature of the flue gas, air temperature and wind speed were dealt with the main parameters to analyze the properties of the plume composed mainly of water vapor. As a result of the simulation, the plume could be more apparent in cold winter due to a big difference of latent heat capacity. At no wind condition, the white plume rises 120 m upward from the top of the stack, and expands to 40 m around from the stack in cold winter after flue gas heat recovery. The influencing distance of relative humidity will be about 100 m to 400 m downstream from the stack with a cross wind effect. The decrease of flue gas temperature by heat recovery of thermal energy facilitates the formation of the plume and restrains its dispersion. Wind speed with vertical distribution affects the plume dispersion as well as the density.

Design of Turbidity Measurement of White Plume using Optical Method (광학기법을 이용한 백색 굴뚝연기 혼탁도 측정의 설계)

  • Son, Hyun-Keun;Ban, Chae-Hoon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.6
    • /
    • pp.1195-1200
    • /
    • 2020
  • The DOM (: Digital Optical Method), which measures the turbidity of chimney smoke, is a method of calculating the turbidity by setting the area to be measured and the contrast area using a low-cost digital camera that can be easily obtained. However, it is difficult to measure clouds and white smoke in a cloudy sky. In this paper, we develop a background sky type model that can represent the background sky and classify the type by periodically photographing it with a digital camera to solve this problem. In addition, based on the model, we develop a filter to optimize white smoke image and prove its excellence through experiments.

Effect of Filler on the Flow of Counter Flow Type Cooling Tower (충진재(Filler)가 대향류형(Counter Flow Type) 냉각탑 유동에 미치는 영향에 대한 연구)

  • Shin, Jeong-Hoon;Lee, Jun-Kyoung;Jin, Cheol-Gyu
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.4_2
    • /
    • pp.565-572
    • /
    • 2022
  • The white plume from the cooling tower can be generated by mixing between discharging hot and humid air and cold air outside. This causes various problems such as icing, traffic disturbances, and fire factors in the vicinity, moreover it can also damage the image of a company. Various methods can be used to prevent white plume, one of them is to install a heat exchanger at the outlet of the cooling tower so that the heat exchanger transfers as much heat as possible to lower the temperature. Therefore the air flow path in the cooling tower should be optimized. Installation of the filler can be used to make the air flow better, thus we investigate the effect of filler on the air flow using CFD method. The pressure and velocity profile in the cooling tower could be acquired by the calculations. The filler made the velocity of the air entering the heat exchanger uniform this was because high flow resistance of the filler suppresses the generation of eddy in the cooling tower. But the total air pressure drop increased about 2 times with filler because the pressure drop by the filler accounted for about 60% of the total pressure drop.

Practical Study of the Thermal Efficiency Improvement and the White Plume Removal from Flue Gas by Fuel Additive Injection (연료첨가제를 이용한 열효율향상 및 가시백연 제거에 관한 연구)

  • 전상기;조승원;황영호
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.11a
    • /
    • pp.487-488
    • /
    • 2003
  • 우리나라 대기환경기준이 점차 강화되고 있고, 국민의 욕구수준 또한 선진국 수준으로 강화될 계획으로 있어 이에 따른 대기오염 방지시설의 설치 또는 보완이 요구되고 있다 특히, 배기가스 중 황산화물 및 질소산화물 배출농도 강화로 울산화력발전소에서는 최신의 배연탈황ㆍ탈질설비를 가동중에 있으나 황산 Mist가 주요원인으로 추정되는 Plume Opacity가 발생되어 오염물질 배출농도는 법적규제기준 이내로 배출되더라도 민원이 발생되고 있다. 이에 대한 대책으로 현장에 적합한 연료첨가제 주입으로 Plume Opacity 발생원인을 제거함과 동시에 배연탈황설비에서 발생된 저온부식 현상을 개선하고, 보일러 내 고온부식 등 연소장애 현상 개선을 통한 열효율 향상 방안에 대해 연구하였다. (중략)

  • PDF

Study on the Suppression of Sulfur Trioxide in High Sulfur Boiler (고유황 보일러에서의 Sulfur Trioxide의 억제에 대한 연구)

  • Choi, Sung-Bu
    • Journal of the Korean Applied Science and Technology
    • /
    • v.28 no.4
    • /
    • pp.455-463
    • /
    • 2011
  • The average sulfur content of crude oil is 2.2%. Coal is about 0.3 to 4.0 percent of the sulfur gases or particles being discharged into the atmosphere through the chimney as 1 to 2% $SO_3$(Sulfur trioxide) and about 95% of the $SO_2$ is reported. $SO_3$ gas, which has many different causes of, as the combustion of sulfur containing fuel during the air due to the excess $SO_2$ gas is oxidized to $SO_3$ gas. Sulfur trioxide emitted from high sulfur heavy oil fired boiler caused white plume in stack and high temperature and cold end corrosion of facilities. So, in order to control sulfur trioxide concentration of Fuel gas in boiler, various of additives are used in other foreign. They are injected to Fuel Oil and consumed in boiler and reduce ash and the conversion rate of sulfur trioxide. In domestic, MgO compounds are used as additives but the total volume of them are made from other foreign company. In this study, MgO compounds were developed with liquid MgO compounds and field application was accomplished. The effect of newly developed chemicals and process were nearly equal to foreign products. In Consequent, the chemicals and process produced by newly developed technology can be substituted for foreign products and reduce the cost of plant operation.

Practical Study of The Phenomenon and Removal of White Smoke for JBR FGD Plant (JBR FGD Plant에 있어서의 가시매연 발생원인 및 제거 방안 연구)

  • 전상기;조승원;황영호;이병규
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2000.11a
    • /
    • pp.273-273
    • /
    • 2000
  • 우리나라 대기환경기준은 이미 선진국 수준으로 강화되었거나 강화될 계획으로 있어 이에 따른 대기오염 방지시설의 설치 또는 보완이 요구되고 있다. 특히, 배기가스 중 황산화물 배출농도 강화로 황산화물 저감을 위한 배연탈황설비 설치ㆍ가동중에 있으나 황산 Mist가 주요원인으로 추정되는 Plume Opacity가 발생되어 대기 중에서 색깔을 띄게됨에 따라 오염물질 배출농도는 법적 규제기준 이내로 배출되더라도 인간의 심리적 불안감을 유발할 수 있어, 그 발생원인을 규명함과 동시에 현장여건에 적합한 최적의 황산 Mist 저감방법을 연구하고자 하였다. (중략)

  • PDF