A Study on Development of the Wet Type Filter for Combustion Air of Diesel Engine (디젤엔진 연소공기 습식여과기의 개발에 관한 연구)

  • Kim, Yong-Seok;Park, Sung-Ho;Yang, Soon-Young
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.1
    • /
    • pp.158-164
    • /
    • 2008
  • In this paper, the performance of wet type filter for diesel engine combustion air has been studied with effects of air temperature, humidity, and pressure. After experiments are performed without diesel engine, it has been investigated the applicability to diesel engine. Wet type filter for diesel engine combustion air had advantages that it is not necessary to change air filter and that engine exhaust gas is environmentally friendly due to low NOx and particulate emission. Also, the filtration performance has been carried out with smoke shell.

An Effect of Wet Type Air Filter in Heavy-Duty Diesel Engine (대형디젤기관에 미치는 습윤식 에어 필터의 영향)

  • 김미수;나완용;오용석
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.3
    • /
    • pp.98-103
    • /
    • 2004
  • Diesel engine offers superior fuel consumption than gasoline engine of equivalent capacity. For this reason, diesel engines are widely used in heavy duty transport applications. Specially, it has been many years that exhaust gases from gasoline automobile rather than from diesel is the major object concerned by Korea and other countries, and it is strongly required on the reduction techniques on harmful NOx, Soot, CO, He. Thus, this paper focused on the emission reduction and target for this paper is heavy-duty diesel engine equipped with power filter such as wet type air cleaner. In this paper, the performance, exhaust emissions(CO, THC, NOx, Soot) and noise of heavy-duty diesel engine were measured at maximum load condition and the range of 1,000∼2,200rpm. The smoke was measured at FAS(Free Accel Smoke) test mode.

The Natural Ingredient Application Method of Cigarette Filter (천연소재 담배 필터 적용 방법)

  • Kim, Min-Kyu;Yeo, Woon-Hyung;Kim, Soo-Ho;Oh, Kyung-Hwan;Jin, Yong-Sook;Hwang, Eui-Il
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.35 no.1
    • /
    • pp.13-19
    • /
    • 2013
  • The natural ingredient has been utilized variety of the food and medicine. The aromatherapy well known prevent disease and healthy promotion using the essential oil derived extracted plants. In this work, natural ingredient include herb granulated for application of tobacco filter. That used by granulation using fluidized bed granulator(top-spray, bottom-spray and tangential-spray) and wet granule method. According to ingredient can used granulating method selectivity. So, we used fluid-bed granulator and wet granule method. Grapefruit extract coated sugar particle using the bottom-spray method and red ginseng granule granulated red ginseng powder using the tangential-spray method in a fluidized bed. Then, these granules applied the tobacco filter after due consideration add amount and operation efficiency. As a result, wet granule was loaded dual filter because that similarity carbon granule. And it was fitted in added 3mg/mm, per tip in the tobacco end part. Another type, fuidized bed granules was filled cavity filter because it has high hardness, sphere shape.

Comparative Efficiency Evaluation of Air Cleaners for Improving Indoor Air Quality (실내용 공기청정기 유형별 실내환경개선 성능에 대한 비교평가)

  • Na, Kyung-Ho;Son, Jin-Seok;Sung, Kijune;Jang, Young-Kee
    • Journal of Environmental Impact Assessment
    • /
    • v.14 no.3
    • /
    • pp.109-115
    • /
    • 2005
  • This study was conducted to evaluate the efficiency of indoor air cleaners and to inform how to select them correctly to the users. The efficiencies of removing suspended bacteria per hour were $64.3{\pm}13.1%$ for filter, wet, and complex type, respectively, which showed the complex type was the most efficient. The removal efficiencies of formaldehyde (HCHO) after two hours operation of air cleaners showed 88.3% and 81.1% for filter and wet type, respectively. The efficiency of complex type, with removal rate of 55.5~58.4%, was decreased after 30 minutes operation. Therefore, it is recommended to perform over 60 minutes when doing air cleaner certification test for HCHO removal efficiency. Generally, air cleaners having low wind volume showed higher efficiency. All tested air cleaners had no potential for removing of volatile organic compounds (VOCs), which is toxic substances, and it is desirable to develop a device which can control these substances. The results also confirmed that there was no ozone production from all tested air cleaners. And it is recommended to ventilate for 20 minutes every four hours to maintain 50% ventilation status.

Effect of inlet structure of filtration system on the removal characteristics of iron particles by ceramic candle filters (집진장치의 유입구조에 따른 세라믹필터의 철입자 제거특성에 미치는 영향)

  • Park, Young-Ok;Jeong, Ju-Yeong;Seo, Yong-Chil
    • Particle and aerosol research
    • /
    • v.5 no.4
    • /
    • pp.189-197
    • /
    • 2009
  • Wet-type particulate removal system is employed in most of ironmaking processes. These de-dusting systems require additional downstream aggregates for treatment of water and for drying of the collected slurry. Thus dried slurry can be pressed in shape of briquettes and recycled in the steelmaking process. Different from the wet-type, the dry-type particulate removal systems generate no slurry. A high-temperature, high-pressure de-dusting system with inertial inlet was developed. The target application of this system was to remove particulate matter generated from the novel ironmaking process and other steelmaking processes. In this study we conducted tests with this newly developed system to evaluate the performance of the silica-carbide (SiC) ceramic filters. In addition, for purpose of comparison, we also conducted tests with a unit which has conventional direct inlet. Fe-Particles collected from the novel ironmaking process were used in our tests as test dusts. The temperature and the pressure were kept constant at their respective values $800^{\circ}C$ and $3kg_f/cm^2$.

  • PDF

Air-Filter Media Characteristics of Wet-laid Nonwoven based on HDPE Plexi-filament (고밀도 폴리에틸렌 플렉시 필라멘트로 제조된 습식부직포의 에어필터 여재 특성 연구)

  • Bae, Younghwan;Wee, Jae-Hyung;Lee, Myungsung;Yeang, Byeong Jin;Kim, Dokun;Yeo, Sang Young
    • Textile Coloration and Finishing
    • /
    • v.33 no.4
    • /
    • pp.302-308
    • /
    • 2021
  • Air filters are being used in countless places from industrial sites to everyday life. The spread of the COVID-19 virus, which started in 2019, is disrupting people's daily lives, and the importance of air filters as a basic means to prevent the spread of these diseases is further highlighted. In this study, the purpose was to develop another type of air filter media with excellent barrier properties that can replace PP meltblown nonwoven fabrics widely used commercially due to its excellent electrostatic properties, differential pressure and filtration efficiency. Therefore, wet-laid nonwoven for air filters were manufactured using plexi-filaments formed through flash spinning and having various fiber diameter from hundreds of nanometers to tens of micrometers, and its applicability as an air-filter media was investigated compared to the meltblown nonwoven. As a result of the performance evaluation, it was found that the filtration efficiency and barrier performance at 0.3㎛ was superior to that of the meltblown nonwoven of the same weight, although the differential pressure was high due to morphological properties of the plexi-filament.

Treatment Study on the Combustion Gas of Medical Waste (의료폐기물 소각가스 처리에 관한 연구)

  • Lee, Sung-Jin;Seo, Man-Chul
    • Journal of environmental and Sanitary engineering
    • /
    • v.23 no.3
    • /
    • pp.1-8
    • /
    • 2008
  • Currently, medical waste stoker incinerator is widely used in the emission control technology of health-care risk waste and miscellaneous contaminated waste. In the past, wet type control technology was used to remove the major harmful gaseous contaminants of medical waste such as HCl, $NO_x,\;SO_2$, CO, DUST, Dioxin. However, the treatment cost for wastewater was high and it has a disadvantage for frozen system during winter season. Therefore, in order to obtain effective treatment, the dry type control technology was developed and widely used to remove the gaseous contaminants. In this study, pre-coated bag filter using hydrated lime, ($Ca(OH)_2$), was applied to the dry type control system and the optimum dose of hydrated lime was investigated. The treatment results showed that the dust collection rate was approximately 26.7%. Moreover, the HCl removal rate using pre-coated bag filter ($50mg/sm^3\;Ca(OH)_2$) was 13.52%, which was significantly higher than 3.26% obtained from conventional bag filter.

A Study on the Manufacture of Optical Filters for PDP Panel in Conductive Types (PDP 패널용 전도막 광학 필터 제조에 관한 연구)

  • Kim, Tae-Hoon;Kang, Bong-Gu;Lee, Tae-Hoon;Son, Se-Mo
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.26 no.2
    • /
    • pp.31-43
    • /
    • 2008
  • The functional dyes, which has various optical characteristics that can be applicable to field of electronic, photo electronic, such as sensor or electrode, were synthesized. Physical property and optical stability was studied with preparation of conductive type film as a kind of optical filter of plasma display panel, by adapting neon cut off dye, which can selectively absorbing between 580 and 610nm wavelength. The filter was prepared with PSA resin, which has functional group of - COOH and - OH, as binder. And the characters such as spectroscopy, heat-proof / wet-proof, thermal stability and commerciality, which must be held by functional dyes, were examined. Conductive type film is the kind of film includes only neon cut off dyes. For the neon cut off dyes, cyanine dyes can be applied. And it is observed that spectrum of before and after the durability test are not changed due to stability of dyes, as the result of coating on the mesh film with PSA binder.

  • PDF

Removal Characteristics of $SO_2$ in the Coal Combustion Flue Gas Treatment Convergence System (석탄화력발전소 현장의 석탄연소 배가스 고도처리용 건식 분류층 반응 실증장치에서의 $SO_2$ 제거성능 특성)

  • Jeon, Seong-Min;Park, Hyung-Sang;Park, Young-Ok
    • Particle and aerosol research
    • /
    • v.9 no.4
    • /
    • pp.239-246
    • /
    • 2013
  • The purpose of this study is to determine the feasibility of dry-type desulfurization process for actual application to coal-fired power plant. We used actual exhaust gas from Facility Y, Plant #2 to fabricate a demo-scale testing device to attempt to improve the efficiency of desulfurization. A spout-bed circulating dry scrubber convergence system connecting turbo reactor with bag filter was devised, then analyzed for performance characteristics of $SO_2$ removal for Ca/S mole ratio, superficial gas velocity, and ammonia injection, and for secondary reaction characteristics of the non-reactive sorbent at the bag filter. As a result, the installation of spout-bed circulating dry scrubber convergence system showed better economy and efficiency for removing sulfur than the existing wet/semidry-type desulfurization process. In addition, the best efficiency for desulfurization occurred when connected to the bag filter, with differential pressure maintained at 150 $mmH_2O$.

Development of Dry-type Surface Myoelectric Sensor for the Shape of the Reference Electrode and the Inter-Electrode Distance (기준전극의 형상과 입력전극사이의 간격을 고려한 건식형 표면 근전위 센서 개발)

  • Choi, Gi-Won;Choe, Gyu-Ha
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.12
    • /
    • pp.550-557
    • /
    • 2006
  • This paper proposes a dry-type surface myoelectric sensor for the myoelectric hand prosthesis. The designed surface myoelectric sensor is composed of skin interface and processing circuits. The skin interface has one reference and two input electrodes, and the reference electrode is located in the center of two input electrodes. In this paper is proposed two types of sensors with the circle- and bar-shaped reference electrode, but all input electrodes are the bar-shaped. The metal material of the electrodes is the stainless steel (SUS440) that endures sweat and wet conditions. Considering the conduction velocity and the median frequency of the myoelectric signal, the inter-electrode distance (IED) between two input electrodes as 18mm, 20mm, and 22mm is selected. The signal processing circuit consists of a differential amplifier with a band pass filter, a band rejection filter for rejecting 60Hz power-line noise, amplifiers, and a mean absolute value(MAV) circuit. Using SUS440, six prototype skin interface with different reference electrode shape and IED is fabricated, and their output characteristics are evaluated by output signal obtained from the forearm of a healthy subject. The experimental results show that the skin interface with parallel bar shape and the 18mm IED has a good output characteristics. The fabricated dry-type surface myoelectric sensor is evaluated for the upper-limb amputee.