• Title/Summary/Keyword: Wellbore storage

Search Result 9, Processing Time 0.028 seconds

Estimation of Hydraulic Parameters of a Fractured Rock Aquifer Using Derivative Analysis (변동량 분석을 이용한 암반대수층의 수리학적 매개변수 산출)

  • Kim, Bum-Su;Yang, Dong-Chul;Yeo, In-Wook
    • Journal of Soil and Groundwater Environment
    • /
    • v.15 no.6
    • /
    • pp.46-52
    • /
    • 2010
  • Derivative analysis, based on the derivative of the drawdown as a function of time (i.e., rate of drawdown change), was applied to the evaluation of hydraulic parameters of the aquifer as an aid of the aquifer test interpretation based on the Theis solutions. Pumping tests were conducted at a coastal fractured aquifer in Muan county, Korea, of which the drawdown data, measured at the two observation wells, were used for derivative analysis. Wellbore storage and transition period were hard to identify at conventional log-log and semi long plots, but was easily recognized by distinctive curves of positive unit slope, hump and negative unit slope in the derivative plot. For the observation well of OW-2 at which wellbore storage and transition lasted over an hour, conventional aquifer analysis would suffer from the uniqueness problems and in further result in erroneous hydraulic parameters. Derivative analysis was found to be effective for distinguishing the drawdown data directly reflecting the aquifer property from those reflecting non aquifer effects such as wellbore storage and transition, which offers a unified methodology to yield correct hydraulic parameters from aquifer test data.

Numerical Analysis of CO2 Behavior in the Subsea Pipeline, Topside and Wellbore With Reservoir Pressure Increase over the Injection Period (시간 경과에 따른 저류층 압력 상승이 파이프라인, 탑사이드 및 주입정 내 CO2 거동에 미치는 영향에 대한 수치해석적 연구)

  • Min, Il Hong;Huh, Cheol;Choe, Yun Seon;Kim, Hyeon Uk;Cho, Meang Ik;Kang, Seong Gil
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.19 no.4
    • /
    • pp.286-296
    • /
    • 2016
  • Offshore CCS technology is to transport and inject $CO_2$ which is captured from the power plant into the saline aquifer or depleted oil-gas fields. The more accumulated injected $CO_2$, the higher reservoir pressure increases. The increment of reservoir pressure make a dramatic change of the operating conditions of transport and injection systems. Therefore, it is necessary to carefully analyze the effect of operating condition variations over the injection period in early design phase. The objective of this study is to simulate and analyze the $CO_2$ behavior in the transport and injection systems over the injection period. The storage reservoir is assumed to be gas field in the East Sea continental shelf. The whole systems were consisted of subsea pipeline, riser, topside and wellbore. Modeling and numerical analysis were carried out using OLGA 2014.1. During the 10 years injection period, the change of temperature, pressure and phase of $CO_2$ in subsea pipelines, riser, topside and wellbore were carefully analyzed. Finally, some design guidelines about compressor at inlet of subsea pipeline, heat exchanger on topside and wellhead control were proposed.

Permeability, crossflow and storativity effects in two-layer aquifer system with fractional flow dimension (분할유동차원 2층 대수층에서의 투수성, 층간흐름, 저류성의 효과)

  • 함세영
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2000.11a
    • /
    • pp.81-84
    • /
    • 2000
  • Two-layer aquifer system with fractional flow dimension is composed of contiguous two layers: Layer 1 (lower layer) and Layer 2 (upper layer) with different permeability and specific storage each other. For this aquifer system, we assume that groundwater flow originates only from Layer 1 on the pumping well. The aquifer system considers wellbore storage and skin effects on the pumping well. Dimensionless drawdown curves for different flow dimensions are analyzed for different lambda (λ, crossflow coefficient) values, kappa ($textsc{k}$, permeability ratio between Layer 1 and Layer 2) values and omega ($\omega$, storativity ratio between Layer 1 and Layer 2) values. The curves for Layer 1 and Layer 2 show characteristic trend each other.

  • PDF

Dual-permeability Fractal Model of Groundwater Flow in Fissured Aquifers (균열대수층내 지하수유동에 관한 이중투수율 프락탈모델)

  • Bidaux, Pascal;Hamm, Se-Yeong
    • Economic and Environmental Geology
    • /
    • v.30 no.5
    • /
    • pp.433-442
    • /
    • 1997
  • A dual-permeability fractal model of fluid flow is proposed. The model simulates groundwater flow in fissured dual aquifer system composed of Aquifer 1 and Aquifer 2. For this model. groundwater flow originates only from Aquifer 1 on the pumping well. The model considers wellbore storage and skin effects at the pumping well and then shows exact drawdown at the early time of pumping. Type curves for different flow dimensions and for two cases are presented and analyzed. The case 1 represents the aquifer system which consists of Aquifer 1 with low permeability and high specific storage and Aquifer 2 with high permeability and low specific storage. The case 2 is inverse to the case 1. Dimensionless drawdown curves in Aquifer 1 and Aquifer 2 shows characteristic trend each other. Consequently, the model will be useful to analyze pumping test data of different draw down patterns on the pumping well and observation wells.

  • PDF

The Pore Volume of Groundwater Level Drawdown Zone Through Slug/Bail Tests in Sand and Silt Soils (모래와 실트의 혼합층에서 순간충격시험에 의한 지하수위 강하구역의 공극체적 산정)

  • Kim, Tae-Yeong;Kang, Dong-Hwan;Chung, Sang-Yong;Yang, Sung-Il;Lee, Min-Hee
    • Journal of Soil and Groundwater Environment
    • /
    • v.12 no.4
    • /
    • pp.1-7
    • /
    • 2007
  • Slug/bail tests were conducted in sand layer (sbt-1 well), silty sand layer (sbt-2 well), and mixed sand and silty sand layer (sbt-3 well). Hydraulic conductivity and specific storage coefficient were estimated through slug/bail tests. Pore volumes of groundwater level drawdown zone for bail test were estimated by using hydraulic conductivity and specific storage coefficient. KGS model was most suitable interpretation method of slug/bail tests. Average hydraulic conductivity for slug/bail tests were estimated to be $6.65{\times}10^{-5}$ m/sec in sbt-1 well, $6.33{\times}10^{-6}$ m/sec in sbt-2 well, and $3.72{\times}10^{-5}$ m/sec in sbt-3 well. Average specific storage coefficient for slug/bail tests were estimated to be 0.0225 in sbt-1 well, 0.0177 in sbt-2 well, and 0.0259 in sbt-3 well. Dimensionless time and dimensionless wellbore storage were estimated by use of transmissivity, storativity, test time, and specification of test wells. And, dimensionless drawdown were selected by parameter ${\alpha}\;and\;{\beta}$ parameter from Cooper et al. (1967). Radius of influence were estimated by estimated dimensionless time, dimensionless wellbore storage, and dimensionless drawdown. The average radius of influnce for slug/bail tests were estimated to be 1.377 m in sbt-1 well, 1.253 m in sbt-2 well, and 1.558 m in sbt-3 well. Pore volume at groundwater level drawdown zone by dummy withdrawal for bail tests were estimated to be $145,636cm^3$ in sbt-1 well, $71,561cm^3$ in sbt-2 well, and $100,418cm^3$ in sbt-3 well. Pore volume excepted well volume at groundwater level drawdown zone by dummy withdrawal for bail tests were estimated to be $145,410cm^3$ in sbt-1 well, $71,353cm^3$ in sbt-2 well, and $100,192cm^3$ in sbt-3 well.

Fractal Model of Transient Flow in a Dual-porosity Aquifer with Constant-head Upper Boundary (일정수두 상부경계를 가지는 이중공극 대수층내 부정류에 관한 프락탈모델)

  • 함세영
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.4 no.2
    • /
    • pp.95-102
    • /
    • 1997
  • So far, several fractal models of fluid flow in a fractured aquifer have been developed. In this study, a new fractal model is derived that considers transient flow in the dual-porosity aquifer with the fracture skin between the fissure and the block, and the storage capacity and the wellbore skin on the pumping well. Constant-head upper boundary is specified in the block. This model is a generalized one which comprises both modified Hantush equation (1960) and Boulton-Streltsova equation (1978). Type curves are plotted for different flow dimensions (0.5, 1, 1.5, 2, 2.5 and 3) with various values of the leakage factor and the fracture skin. They show dimensionless drawdown in the pumping well and observation wells located either in the fissure system or in the matrix block.

  • PDF

A Preliminary Evaluation on CO2 Storage Capacity of the Southwestern Part of Ulleung Basin, Offshore, East Sea (동해 울릉분지 남서 주변부의 이산화탄소 저장 용량 예비 평가)

  • Kim, Yu-Lee;Lee, Keum-Suk;Jo, So-Hyun;Kim, Min-Jun;Kim, Jong-Soo;Park, Myong-Ho
    • Economic and Environmental Geology
    • /
    • v.45 no.1
    • /
    • pp.41-48
    • /
    • 2012
  • A theoretical $CO_2$ storage capacity is estimated on the southwestern continental shelf margin of Ulleung Basin, offshore Korea using 2D/3D multi-channel seismic and wellbore data acquired in the area over the two decades since the late 1980s. For the first time in Korea, the present study applies an efficiency factor to the capacity calculation, together with the other required parameters. For possible $CO_2$ storage volume estimation of the study area, we interpreted the seismic data in the Gorae area from 800 m to 3,000 m below the seafloor integrated with the well data, and identified five different seismic units; the limited depth interval is considered because of fluid state of $CO_2$ and tightness of the formation. The total volumes of each seismic unit were converted with a time-depth relation inferred from the checkshot surveys before the other required parameters including porosity and density were applied to compute the potential storage capacity. The accumulated possible storage volume from the five depositional units in the study area is estimated to be approximately 5,100 Mton ($P_{50}$). The approaches made in this study will be applied to the rest area of the basin and other continental shelves (i.e., Yellow Sea and northern part of East China Sea) in the next phase.

The Development of Straddle Packer Hydraulic Testing Equipment to Characterize Permeability in Deep Boreholes (장심도 시추공 정밀수리시험 장비 구축)

  • Kim, Kyung-Su;Park, Kyung-Woo;Ji, Sung-Hoon
    • The Journal of Engineering Geology
    • /
    • v.20 no.2
    • /
    • pp.213-220
    • /
    • 2010
  • The permeability characterization on the natural barrier for deep geological disposal of radioactive waste is very critical to evaluate total safety and performance assessment of disposal site. However, the confidence level in using previous hydraulic testing equipments consist of simple components to estimate rock mass permeability is not high enough to reflect in situ condition. The purpose of this research is to establish an advanced hydraulic testing equipment, which is applicable to deep borehole (up to 1,000 m), through the improvement of technical problems of previous packer systems. Especially, the straddle packer hydraulic testing equipment was designed to adopt both the hydraulic downhole shut-in valve(H-DHSIV) to minimize the wellbore storage effect and the real time data acquisition system to measure the pressure changes of test interval including its upper and lower parts. The results from this research lead to not only improve current technical level in the field of hydraulic testing but also provide important information to radioactive waste disposal technology development and site characterization project.

Report on Extended Leak-Off Test Conducted During Drilling Large Diameter Borehole (국내 대구경 시추공 굴진 중 Extended Leak-Off Test 수행 사례 보고)

  • Jo, Yeonguk;Song, Yoonho;Park, Sehyeok;Kim, Myung Sun;Park, In-Hwa;Lee, Changhyun
    • Tunnel and Underground Space
    • /
    • v.32 no.5
    • /
    • pp.285-297
    • /
    • 2022
  • We report results of Extended Leak-Off Test (XLOT) conducted in a large diameter borehole, which is drilled for installation of deep borehole geophysical monitoring system to monitor micro-earthquakes and fault behavior of major fault zones in the southeastern Korean Peninsula. The borehole was planned to secure a final diameter of 200 mm (or more) at a depth of ~1 km, with 12" diameter wellbore to intermediate depths, and 7-7/8" (~200 mm) to the bottom hole depth. We drilled first the 12" borehole to approximately 504 m deep and installed American Petroleum Institute standard 8-5/8" casing, then annulus between the casing and bedrock was fully cemented. XLOT was carried out for several purposes such as confirming casing and cementing integrity, measuring rock stress states. To that end, we drilled additional 4 m long open hole interval to directly inject water and pressurize into the rock mass using the upper API casings. During the XLOT, flow rates and interval pressures were recorded in real time. Based on the logs we tried to analyze hydraulic conductivity of the test interval.