• 제목/요약/키워드: Well clogging

검색결과 55건 처리시간 0.026초

흙 필터재의 폐색으로 인한 투수성 저하 모델 개발 (Modelling of Permeability Reduction of Soil Filters due to Clogging)

  • 이인모;박영진
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 가을 학술발표회 논문집
    • /
    • pp.271-278
    • /
    • 1999
  • Soil filters are commonly used to protect the soil structures from eroding and piping. When filters are clogged by fine particles which are progressively accumulated, these may lead to buildup of excessive pore pressures also leading to instability in subsurface infrastructure. A filter in the backfill of a retaining wall, a filter adjacent to the lining of a tunnel, or a filter in the bottom of an earth dam can be clogged by transported fine particles. This causes reduction in the permeability, which in turn may lead to intolerable decreases in their drainage capacity. In this thesis, the extent of this reduction is addressed using results from both experimental and theoretical investigations. In the experimental phase, the permeability reduction of a filter is monitored when an influent of constant concentration flows into the filter (uncoupled test), and when the water flow through the soil-filter system to simulate an in-situ condition (coupled test), respectively. The results of coupled and uncoupled test are compared with among others. In the theoretical phase of the investigation, a representative elemental volume of the soil filter was modeled as an ensemble of capillary tubes and the permeability reduction due to physical clogging was simulated using basic principles of flow in cylindrical tubes. In general, it was found that the permeability was reduced by at least one order of magnitude, and that the results from the uncoupled test and theoretical investigations were in good agreement. It is observed that the amount of deposited particles of the coupled test matches fairly well with that of the uncoupled test, which indicates that the prediction of permeability reduction is possible by preforming the uncoupled test instead of the coupled test, and/or by utilizing the theoretical model.

  • PDF

Assessing the removal efficiency of Synedra sp. through analysis of field data from water treatment plants

  • Seo, Dae-Keun;Kim, Yeong-Kwan
    • Membrane and Water Treatment
    • /
    • 제11권2호
    • /
    • pp.141-149
    • /
    • 2020
  • Prechlorination could increase the removal efficiency of Synedra, but there was no significant effect of increasing the amount of chlorine added. However, a removal efficiency of greater than 80% was noted when ozone was injected at concentrations greater than 2 mg/L. Also, it was found that on addition of polyamine, a removal efficiency of 80% or more could be achieved. As a result of the analysis of field operation data from the water treatment plants G and B, it was found that at water treatment plant G, the filter run time decreased to 10 hours or less when only coagulant was injected, but the filter run time increased to around 40 hours when polyamine (3 mg/L) was also injected. The Synedra population in the raw water subsequently increased to 2,340 cells/mL, and the filter continued running for more than 20 hours. At water treatment plant B, the average Synedra removal efficiency was 56% when only coagulant was injected, and the filter run time decreased drastically with the increasing population of Synedra in the raw water. However, the removal efficiency of Synedra reached 79% when polyamine was injected together with the coagulant, 90% when ozone was also injected, and 95% when polyamine and ozone were injected together and the filter continued running for over 50 hours. The filter run time was maintained at 60 hours when a Synedra population of 6,890 cells/mL flowed into the Paldang water source, but the filter run time with Synedra at 1,960 cells/mL decreased rapidly from 65 hours to 35 hours when the ratio of the size of the individual Synedra reaching 250 ㎛ or more, increased from 38% to 94%. Therefore, the size of the Synedra is considered to be a factor that significantly influences filter clogging, as well as the size of the Synedra population.

Alum 주입 메쉬 침지 여과분리형 생물반응조의 운전 특성과 인 제거 (Phosphorus Removal and Operating Performance of Mesh Filtration Bio-reactor with the Addition of Alum)

  • 정용준;민경석
    • 한국물환경학회지
    • /
    • 제21권5호
    • /
    • pp.458-463
    • /
    • 2005
  • Considering the characteristics of a filtration bio-reactor equipped with a mesh filter module which can effectively maintain high concentration of biomass and enhanced solid-liquid separation performance, the hybrid process of filtration bio-reactor combined with coagulation was investigated to get improved filtration characteristics as well as water quality in this work. Two bio-reactors (Run-1 & Run-2) were operated under the following conditions: working volume of 25 L, continuous loading of a synthetic wastewater (BOD: 200 mg/L, T-N: 50 mg/L, T-P: 5 mg/L), where an appropriate amount of alum ($Al_2(SO_4)_3{\cdot}18H_2O$) was added once a day into the reactor (Run-2). In the system without using a alum (Run-1), the clogging of mesh filter module was observed two times through 85 days of whole operation. Meanwhile, the filter module did not clog even at higher MLSS concentration (6,000~12,000 mg/L) and the stable filtration (0.7 mid) was continued in the case of using a alum. Due to the stable formation of cake layers, BOD and SS were shown below 6 and 3 mg/L, respectively. T-P and pH of the effluent were changed because of the intermittent addition of the alum. In the case of Al/P=2.5, the average T-P removal efficiency per day was 85.2% and the average T-P concentration of the effluent was 0.3 mg/L. However, the removal efficiency of phosphate was influenced by pH in the reactor.

음식물 탈리액 처리를 위한 파일럿 규모의 막결합형 2상 혐기성 소화 공정 가능성 평가 (A feasibility study of a pilot scale two-phase anaerobic digestion with ultra filtration for the treatment of garbage leachate)

  • 이은영;허안희;김형국;김희준;배재호
    • 상하수도학회지
    • /
    • 제23권5호
    • /
    • pp.539-545
    • /
    • 2009
  • A feasibility of a pilot scale two-phase anaerobic digestion with ultra filtration system treating garbage leachate were evaluated. The treatment system consisted of a thermophilic acidogenic reactor, a mesophilic methanogenic reactor, and an UF membrane. The average COD removal efficiency of the treatment system was 95% up to the OLR of 3.1 g COD/L/d. The higher COD removal efficiency with membrane unit resulted from the removal of some portion of soluble organics by membrane as well as particulate materials. When the membrane unit was in operation, bulk liquid in acidogenic and methanogenic reactors was partially interchanged, which maintained the acidogenic reactor pH over 5.0 without external chemical addition. Also, with the production of methane in the acidogenic reactor, the organic loading rate of the methanogenic reactor reduced. The initial flux of the membrane unit was $50{\sim}60L/m^2/hr$, but decreased to $5 L/m^2/hr$ after 95 days of operation due to clogging caused by particulate materials such as fibrous materials in garbage leachate. To prevent clogging caused by particulate materials, a pretreatment system such as screening is required. With the improvement with membrane unit operation, the two-phase anaerobic digestion with ultra filtration system is expected to have the possibility of treating garbage leachate.

Engineered bioclogging in coarse sands by using fermentation-based bacterial biopolymer formation

  • Kim, Yong-Min;Park, Taehyung;Kwon, Tae-Hyuk
    • Geomechanics and Engineering
    • /
    • 제17권5호
    • /
    • pp.485-496
    • /
    • 2019
  • Sealing of leakage in waterfront or water-retaining structures is one of the major issues in geotechnical engineering practices. With demands for biological methods as sustainable ground improvement techniques, bioclogging, defined as the reduction in hydraulic conductivity of soils caused by microbial activities, has been considered as an alternative to the chemical grout techniques for its economic advantages and eco-friendliness of microbial by-products. This study investigated the feasibility of bioaugmentation and biostimulation methods to induce fermentation-based bioclogging effect in coarse sands. In the bioaugmentation experiments, effects of various parameters and conditions, including grain size, pH, and biogenic gas generation, on hydraulic conductivity reduction were examined through a series of column experiments while Leuconostoc mesenteroides, which produce an insoluble biopolymer called dextran, was used as the model bacteria. The column test results demonstrate that the accumulation of bacterial biopolymer can readily reduce the hydraulic conductivity by three-to-four orders of magnitudes or by 99.9-99.99% in well-controlled environments. In the biostimulation experiments, two inoculums of indigenous soil bacteria sampled from waterfront embankments were prepared and their bioclogging efficiency was examined. With one inoculum containing species capable of fermentation and biopolymer production, the hydraulic conductivity reduction by two orders of magnitude was achieved, however, no clogging was found with the other inoculum. This implies that presence of indigenous species capable of biopolymer production and their population, if any, play a key role in causing bioclogging, because of competition with other indigenous bacteria. The presented results provide fundamental insights into the bacterial biopolymer formation mechanism, its effect on soil permeability, and potential of engineering bacterial clogging in subsurface.

파종기용 파종 감시 장치 개발 (Development of a Seeder Monitoring System)

  • 김대호;김경욱
    • Journal of Biosystems Engineering
    • /
    • 제21권3호
    • /
    • pp.306-314
    • /
    • 1996
  • A seeder monitoring system was developed to solve the problems of mis-sowing and tube clogging in direct seeding machines, which have been one of the factors that reduce the performance of sowing operations. The system consisted of photo sensors, air nozzles, an air compressor, and a one-chip micro-computer based controller. The system was also equipped with the devices that perform the functions of self-checking and intermittent air injection for cleaning seed tubes. The performance of the system was tested in the laboratory and field. Using the well-cleaned rice seed, the average time for checking the mis-sowing was 1.37 seconds in the field and 1.2 seconds in the laboratory without any malfunction. Overall evaluation of the system indicated that the system can be utilized for seeding machines not only for paddies but beans and corns.

  • PDF

전기수력학 프린팅의 분사 특성 변화에 대한 실험적연구 (An experimental study for characteristic change of Electrohydrodynamic jetting)

  • 김효준;정종렬;양중근;정재원
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1913-1916
    • /
    • 2008
  • Electrohydrodynamic (EHD) printing has gained significant interest after a direct writing with a resolution of a few tens nanometer was demonstrated using EHD. Basically, EHD use the electric field to generate droplet which is much smaller than nozzle diameter, so that high resolution printing is possible and the clogging problem can be alleviated as well. However, to adapt this technology to the real application, the fundamental studies are necessary to stabilize EHD jetting, to maximize jetting frequency, and to optimize the design of multi EHD nozzle, etc. In this study, by imaging EHD jetting using high speed camera and measuring the current, the effect of electric field intensity and back pressure on jetting frequency and jetting diameter were studied.

  • PDF

디칸터의 고장분석 및 성능 향상에 관한 연구 (A Study on the Failure Analysis and Performance Improvement of a Decanter)

  • 신창호;이동철;김우형;최태주;정진태
    • 대한기계학회논문집A
    • /
    • 제28권5호
    • /
    • pp.586-592
    • /
    • 2004
  • In this study, the failure analysis of a decanter is carried out and the methods of performance improvement are presented. The decanter is a centrifugal separator that is used to separate water and solids from municipal and industrial sludge. Therefore, the decanter should be designed to improve the dewatering of sludge. Besides high performance, the decanter should guarantee its life time under a severe using condition. For theses reasons, the failure analysis and performance improvement of the decanter are studied. It is found from this study that the failure is caused by mass unbalance, wear, clogging or crack. If these failure causes are prevented, the life time as well as the performance is expected to be improved.

Iron and manganese removal in direct anoxic nanofiltration for indirect potable reuse

  • Jin, Yongxun;Choi, Yeseul;Song, Kyung Guen;Kim, Soyoun;Park, Chanhyuk
    • Membrane and Water Treatment
    • /
    • 제10권4호
    • /
    • pp.299-305
    • /
    • 2019
  • Managed aquifer recharge (MAR) systems are gaining interest as an alternative to conventional water resources. However, when the water recovered in MAR systems, dissolved iron and manganese species may easily oxidize and they cause well screen clogging or require abandonment of extraction wells. In this study, both oxic and anoxic conditions were analyzed to verify the feasibility of the membrane filtration performance under various solution chemistries. The fouling mechanisms of the metal ions under anoxic conditions were also investigated by employing synthetic wastewater. The fouled membranes were then further analyzed to verify the major causes of inorganic fouling through SEM and XPS. The newly suggested anoxic process refining existing membrane process is expected to provide more precious information about nanofiltration (NF) membrane fouling, especially for demonstrating the potential advantages to chemical-free drinking water production for indirect potable reuse.

농업용 관정의 기계적 처리 이후 성능 개선 효과의 정량적 평가 사례 (Quantitative Evaluation for Improvement Effects of Performance After Mechanical Rehabilitation Treatments on Agricultural Groundwater Well)

  • 송성호;이병선;안중기
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제21권4호
    • /
    • pp.42-49
    • /
    • 2016
  • Step-drawdown pumping tests for identifying the improvement of groundwater well performance after rehabilitation treatments were conducted in three longstanding wells. Three selective mechanical treatment methods including power bubble, high-voltage electric pulse, and air surging were applied to these wells and the applicability of these methods to secure additional groundwater resources were evaluated quantitatively. Commonly, drawdown at final stage of stepdrawdown pumping tests after rehabilitation decreased by as much as 0.61~0.70 meters compared to those before rehabilitation. In addition, final specific drawdown values of three wells increased from 9% to 14% after rehabilitation. Formation loss coefficient and well loss coefficient decreased to 6.1% and 60.6%, respectively, indicating some clogging materials by precipitation/corrosion/microbe within pores of aquifer materials, gravel packs, and screens were effectively removed by applied methods. Decrease of formation loss coefficient was higher in the well applied by the power bubble method meanwhile high-voltage electric pulse method demonstrated the higher decrease of well loss coefficient. Additionally secured groundwater amounts after rehabilitation ranged from 23.3 to 32.1 m3/day, which account for 8~16% of initially developed pumping rates of the wells. From the results of this study, the effective selection of rehabilitation treatments considering aquifer characteristics are expected to contribute to secure groundwater resources for irrigation as well as to plan systematic management program for groundwater resources in rural area.