• 제목/요약/키워드: Welded part

검색결과 297건 처리시간 0.033초

레이저 이종용접에서의 입열량 변화에 대한 용접특성 비교 (Comparison of Welding Characteristics on Heat input Changing of Laser Dissimilar Metals Welding)

  • 신호준;유영태;신병헌;안동규
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 추계학술대회 논문집
    • /
    • pp.997-1003
    • /
    • 2005
  • Laser welding of dissimilar metals has been widely used to improve a wear resistance and a corrosion resistance of the industrial parts. The objective of this research works is to investigate the influence of the process parameters, such as the welding for SM45C and STS304 with CW Nd:YAG lasers. The bead-on-plate welding tests are carried out for several combinations of the experimental conditions. In order to quantitatively examine the characteristics of the dissimilar welding, the welding qualify of the cut section, stain-stress behavior and the hardness of the welded part are investigated. From the results of the investigation, it has been shown that the optimal welding condition without defects in the vicinity of the welded area and with a good welding quality is 1600W of the laser power, 0.85m/min of welding speed and 4m/min of pressure for shielding gas.

  • PDF

Corrosion Properties of Dissimilar Friction Stir Welded 6061 Aluminum and HT590 Steel

  • Seo, Bosung;Song, Kuk Hyun;Park, Kwangsuk
    • Metals and materials international
    • /
    • 제24권6호
    • /
    • pp.1232-1240
    • /
    • 2018
  • Corrosion properties of dissimilar friction stir welded 6061 aluminum and HT590 steel were investigated to understand effects of galvanic corrosion. As cathode when coupled, HT590 was cathodically protected. However, the passivation of AA6061 made the aluminum alloy cathode temporarily, which leaded to corrosion of HT590. From the EIS analysis showing Warburg diffusion plot in Nyquist plots, it can be inferred that the stable passivation layer was formed on AA6061. However, the weld as well as HT590 did not show Warburg diffusion plot in Nyquist plots, suggesting that there was no barrier for corrosion or even if it exists, the barrier had no function for preventing and/or retarding charge transport through the passivation layer. The open circuit potential measurements showed that the potential of the weld was similar to that of HT590, which lied in the pitting region for AA6061, making the aluminum alloy part of the weld keep corrosion state. That resulted in the cracked oxide film on AA6061 of the weld, which could not play a role of corrosion barrier.

Seismic response of built-up double-I column in steel moment resisting frame using welded external diaphragm plate

  • Tabebordbar, Amir;Dehghan, Seyed Mehdi;Fathi, Farshid;Najafgholipour, Mohammad Amir
    • Steel and Composite Structures
    • /
    • 제41권5호
    • /
    • pp.747-759
    • /
    • 2021
  • Built-up Double-I (BD-I) columns have been commonly used for mid-rise steel-frame structures in Iran. These columns consist of two hot rolled IPE sections which are connected by two cover plates and fillet welds. Until 2017, BD-I columns were employed in intermediate moment resisting frames (MRF) using welded flange plate (WFP) connections. To evaluate the seismic behavior of the connections, four samples were made and tested based on cyclic loading according to AISC 341-16. It was concluded that typical samples cannot satisfy the seismic provisions related to intermediate MRFs. In contrast, the proposed connections retrofitted with two-part external diaphragms were able to satisfy not only the seismic requirements related to intermediate MRFs but also those related to special MRFs according to AISC. The numerical modeling of these samples was performed using ABAQUS finite element software. This study compared the hysteresis moment-rotation curves, plastic strains, and behavior modes in both experimental samples and numerical models.

DEVELOPMENT OF CONCRETE FILLED TUBE AS A PILLAR PILE FOR TOP DOWN METHOD

  • Jee-Yun Song;Hong-Chul Rhim;Seung-Weon Kim
    • 국제학술발표논문집
    • /
    • The 3th International Conference on Construction Engineering and Project Management
    • /
    • pp.808-813
    • /
    • 2009
  • Top-down method is widely used for urban area construction for its advantages in reducing environmental problems such as dust and noise, and saving construction cost depending on given conditions of a construction site. Because the excavation and construction of super- and sub-structures of the building have to be proceeded simultaneously, a column has to be embedded prior to excavation. This column is called a pillar column or pre-founded column. Usually a wide flange section is used for these columns. To place the columns, usually the diameter of casing holes needs to be larger than the section of the wide flange itself in order to accommodate a couple of tremie pipes for pouring concrete. In this paper, a newly developed method of using circular pipe as an alternative to the existing wide flange section is discussed. The crucial part of the new method is to develop a connection between the circular column and concrete flat slabs. For shear force transfer from concrete slab to the concrete filled tube (CFT) column, shear jackets with studs and shear bands are proposed. The studs are welded on the jackets at shop and placed around the circular column on site. The shear bands are welded on the outer side of the CFT at shop and inserted into ground with the CFT. Test results and application of the method to a construction site are also provided in this paper.

  • PDF

Development of Automated Welding System for Construction: Focused on Robotic Arm Operation for Varying Weave Patterns

  • Doyun Lee;Guang-Yu Nie;Aman Ahmed;Kevin Han
    • 국제초고층학회논문집
    • /
    • 제11권2호
    • /
    • pp.115-124
    • /
    • 2022
  • Welding is a significant part of the construction industry. Since most high-rise building construction structures rely on a robust metal frame welded together, welding defect can damage welded structures and is critical to safety and quality. Despite its importance and heavy usage in construction, the labor shortage of welders has been a continuous challenge to the construction industry. To deal with the labor shortage, the ultimate goal of this study is to design and develop an automated robotic welding system composed of a welding machine, unmanned ground vehicle (UGV), robotic arm, and visual sensors. This paper proposes and focuses on automated weaving using the robotic arm. For automated welding operation, a microcontroller is used to control the switch and is added to a welding torch by physically modifying the hardware. Varying weave patterns are mathematically programmed. The automated weaving is tested using a brush pen and a ballpoint pen to clearly see the patterns and detect any changes in vertical forces by the arm during weaving. The results show that the weave patterns have sufficiently high consistency and precision to be used in the actual welding. Lastly, actual welding was performed, and the results are presented.

Wind Turbine Tower의 Door 용접부에 대한 피로 강도 연구 (Fatigue Analysis of Welded Toe of Wind Turbine Tower Access Door)

  • 한동영;고장욱;최원호;이승구
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.72-75
    • /
    • 2005
  • Recently, as the global warming by fossil fuels become social issues. the interest of renewable energy producing system is increasing rapidly. Among these, wind turbines are most highlighted because of its economic competitiveness. The tower occupying about $20\%$ of overall turbine costs, is one of the main components of wind turbine. Tower access door located to base part of the tower, is used to enter the tower. This is the main structural weak point because of door hole, weldment, etc. In this study, by FEM, we retrieved the maximum van Mises stress at door location and carried out fatigue analysis using stresses at weld toe locations of tower access door part.

  • PDF

이종마찰 접합계면부의 소성유동 방향성 및 강도 평가 (Plastic Flow Direction and Strength Evaluation of Dissimilar Fiction Bonding Interface Joints)

  • 오정국;성백섭
    • 한국정밀공학회지
    • /
    • 제19권5호
    • /
    • pp.43-50
    • /
    • 2002
  • Friction welding has many merits such as energy efficiency, simple processing, etc butt difficult to obtain good weld at the welded interface and heat affected zone. To date, the continuum mechanics and fracture mechanics are utilized to analyse stresses at the interface and propagation of cracks. In this study. STS304 and SM15C are selected because they can be differentiated distinctively from metallic point of view and crack can be observed easily. It is ovserved during friction welding that STS304, rotary part is hatter than SH15C, fixed part. The last fracture occurs around the center because the surface of fatigue fracture has smooth regions, due to the separation phenomenon in plastic flows layers and striation dimple pattern.

용접부의 기계적 성질 및 피로강도에 미치는 루트 간격의 영향 (The Effects of Root Gap on Mechanical Properties and Fatigue Strength of Weldment)

  • 이원근;장경복;강성수
    • Journal of Welding and Joining
    • /
    • 제19권2호
    • /
    • pp.98-103
    • /
    • 2001
  • Root gap out of standard by welding deformation is frequently produced at butt weld joints of steel bridge. For example although standard root gap is below 6mm at butt weld joints of plates under 15mm thickness. maximum 35mm root opening is produced at the weld field. At this case, the part out of standard is generally built up and the rest part is welded by WPS. Direct welding without built-up welding is preferred in weld field because built-up welding process bring about the cost-up at manufacturing. To apply this direct weld to root gap out of standard, the investigation about mechanical properties and fatigue at weldment is required. Inthisstudy, therefore the verification for direct weld without built up is performed at weldment as root gap. It includes tension, bending. hardness, impact and fatigue test for each welding specimen of 6mm, 25mm, 35mm root gap.

  • PDF

필릿 용접의 기계적 시험 특성 평가 (Evaluation of Mechanical Test Characteristics of Fillet Welding)

  • 조병준;이성준;임종국
    • 한국산학기술학회논문지
    • /
    • 제21권2호
    • /
    • pp.535-541
    • /
    • 2020
  • FCAW는 모든 자세에서 용접이 가능하고 작업여건 변수가 많은 현장에서 우수한 품질을 얻을 수 있는 장점이 있어 탄소강과 합금강의 중판, 후판 용접에 많이 사용되고 있다. 최근 국내에서 진행한 연구논문의 대부분이 피로 강도 평가 방법 연구, 잔류응력 및 변형, 필릿 용접 공정 개발 등의 연구가 시행되었으나 필릿 용접을 대상으로 경도, 매크로, 자분탐상 결과를 토대로 하여 기계적 특성을 나타낸 연구가 부족함에 따라 본 연구에서는 FCAW를 이용하여 상부는 SS400(일반구조용 압연강재) 후판은 SM490A(용접구조용 압연강재)를 이용하여 필릿 용접 후 경도시험, 매크로 시험, 자분탐상시험을 통해 아래와 같은 결론을 도출하였다. 경도시험 결과, 모든 결과 값이 KS B 0893의 규격치 350Hv보다 낮게 나타나 양호한 것으로 판단되었고, 매크로 시험 결과 용접부의 형상별로 균일한 조직 상태를 나타냈으며, 용접부 전 단면에 걸쳐 내부 결함, 기포 또는 불순물 등이 발견되지 않아 lamination의 우려가 없었으며, 자분탐상검사 결과 별도의 문제점이 발견되지 않았다.

SN 강재가 사용된 강구조 용접모멘트접합부의 내진성능 평가 (Evaluating Seismic Performance of Steel Welded Moment Connections Fabricated with SN Steel)

  • 오상훈;최영재;윤성기;이동규
    • 한국강구조학회 논문집
    • /
    • 제22권3호
    • /
    • pp.271-280
    • /
    • 2010
  • 본 연구에서는 국내 건축 구조용 강재인 SN490 강재를 사용하여 실물 크기의 H형강 보와 기둥으로 구성된 모멘트저항골조의 외부 T자형 용접모멘트접합부를 대상으로 실험을 계획하였다. 실험변수를 용접접근공형상, 접합부 이음 방식, RBS(Reduced Beam section)로 하여 9개의 시험체를 제작하였고, 반복재하 실물대 실험을 수행하였다. 실험에 따른 각 시험체의 파괴형태 및 모멘트-층간변위 관계, 변형률 분포를 나타내었으며, 재료인장 실험을 통하여 실험에 사용된 시험체의 전소성모멘트를 구한 다음 특수모멘트 접합부에 해당하는 시험체를 분류하였다. 각 시험체의 모멘트-층간변위 곡선을 골격곡선과 바우싱거곡선으로 분리하여 내력상승률, 소성배율, 에너지 소산량 등을 나타내었으며 이를 가지고 각 시험체의 소성변형능력을 평가하였다. 실험결과 용접접근공이 제거된 시험체가 기존 용접접근공형상을 가지는 시험체에 비하여 우수한 내진성능을 나타내었고, 보 웨브를 용접과 볼트를 병행하고 전단탭을 전체에 걸쳐 보강 용접한 시험체가 가장 우수한 내진성능을 나타내었다.