• 제목/요약/키워드: Welded connection

검색결과 158건 처리시간 0.022초

용접 수평헌치로 보강된 철골 모멘트 접합부의 내진설계 (Seismic Design of Steel Moment Connections with Welded Straight Haunch)

  • 이철호
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall 2000
    • /
    • pp.269-277
    • /
    • 2000
  • This paper describes a seismic design procedure for steel moment connections with welded straight haunch. Recent test results showed that welding a straight haunch beneath the beam could be a viable solution for not only repair and rehabilitation of pre-Northridge moment connections but also new construction. Although a design procedure for the connection with triangular welded haunch has been developed recently, it is not applicable for the straight haunch moment connection because the force transfer mechanism is different. A simplified analytical model that considers the force interaction and deformation compatibility between the beam and haunch is briefly presented first based on the writer`s previous study. A generic design procedure as well as details that minimize the stress concentration at the haunch tip are also recommended.

  • PDF

Degradation and damage behaviors of steel frame welded connections

  • Wang, Meng;Shi, Yongjiu;Wang, Yuanqing;Xiong, Jun;Chen, Hong
    • Steel and Composite Structures
    • /
    • 제15권4호
    • /
    • pp.357-377
    • /
    • 2013
  • In order to study the degradation and damage behaviors of steel frame welded connections, two series of tests in references with different connection constructions were carried out subjected to various cyclic loading patterns. Hysteretic curves, degradation and damage behaviours and fatigue properties of specimens were firstly studied. Typical failure modes and probable damage reasons were discussed. Then, various damage index models with variables of dissipative energy, cumulative displacement and combined energy and displacement were summarized and applied for all experimental specimens. The damage developing curves of ten damage index models for each connection were obtained. Finally, the predicted and evaluated capacities of damage index models were compared in order to describe the degraded performance and failure modes. The characteristics of each damage index model were discussed in depth, and then their distributive laws were summarized. The tests and analysis results showed that the loading histories significantly affected the distributive shapes of damage index models. Different models had their own ranges of application. The selected parameters of damage index models had great effect on the developing trends of damage curves. The model with only displacement variable was recommended because of a more simple form and no integral calculation, which was easier to be formulated and embedded in application programs.

계산 방법론에 따른 용접부 응력 평가 및 비교(FE 상세 모델 vs 수 계산) (Stress Comparison on Welded Connection between Detail FE Model and Classical Calculation)

  • 송문성;정상웅
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.621-626
    • /
    • 2010
  • According to development of method and device of Finite Element Analysis, the strength of welded joint is demonstrated by Finite Element Analysis not classical calculations. On the FEA, all of the joints for carbody are assumed to be ideal connections and the yield stress of welded joint is assumed to be the same to base metal. On these assumption, FEA is appropriate to evaluate the overall stability and strength of whole carbody. The classical calculation is appropriate to evaluate strength of specific welded joint and to determine the weld method and properties. Some project request strength calculation of the specific welded joints in addition to FEA, because of the demonstration of stability. The objective of this paper is the check of the consistency of the FEA result for the welded joints by the stress comparison between Detailed FE Model and classical calculation and the evaluation of the reliability of FEA result.

  • PDF

Investigation of shear lag effect on tension members fillet-welded connections consisting of single and double channel sections

  • Barkhori, Moien;Maleki, Shervin;Mirtaheri, Masoud;Nazeryan, Meissam;Kolbadi, S.Mahdi S.
    • Structural Engineering and Mechanics
    • /
    • 제74권3호
    • /
    • pp.445-455
    • /
    • 2020
  • Shear lag phenomenon has long been taken into consideration in various structural codes; however, the AISC provisions have not proposed any specific equation to calculate the shear lag ratio in some cases such as fillet-welded connections of front-to-front double channel sections. Moreover, those equations and formulas proposed by structural codes are based on the studies that were conducted on riveted and bolted connections, and can be applied to single channel sections whilst using them for fillet-welded double channels would be extremely conservative due to the symmetrical shape and the fact that bending moments will not develop in the gusset plate, resulting in less stress concentration. Numerical models are used in the present study to focus on parametric investigation of the shear lag effect on fillet-welded tension connection of double channel section to a gusset plate. The connection length, the eccentricity of axial load, the free length and the thickness of gusset plate are considered as the key factors in this study. The results are then compared to the estimates driven from the AISC-LRFD provisions and alternative equations are proposed.

Experimental and numerical assessment of beam-column connection in steel moment-resisting frames with built-up double-I column

  • Dehghan, Seyed Mehdi;Najafgholipour, Mohammad Amir;Ziarati, Seyed Mohsen;Mehrpour, Mohammad Reza
    • Steel and Composite Structures
    • /
    • 제26권3호
    • /
    • pp.315-328
    • /
    • 2018
  • Built-up Double-I (BD-I) columns consist of two hot rolled IPE sections and two cover plates which are welded by fillet welds. In Iran, this type of column is commonly used in braced frames with simple connections and sometimes in low-rise Moment Resisting Frames (MRF) with Welded Flange Plate (WFP) beam-column detailing. To evaluate the seismic performance of WFP connection of I-beam to BD-I column, traditional and modified exterior MRF connections were tested subjected to cyclic prescribed loading of AISC. Test results indicate that the traditional connection does not achieve the intended behavior while the modified connection can moderately meet the requirements of MRF connection. The numerical models of the connections were developed in ABAQUS finite element software and validated with the test results. For this purpose, moment-rotation curves and failure modes of the tested connections were compared with the simulation results. Moreover to avoid improper failure modes, some improvements of the connections were evaluated through a numerical study.

PHC파일간 연결 시공성 개선 이음판형 기계적 연결부의 연결저항 (Connection Resistance of Mechanical Joint using Connection plate for Improvement of Connectivity between PHC piles)

  • 안진희;문홍득;하민균;조광일
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제23권7호
    • /
    • pp.25-32
    • /
    • 2019
  • PHC 파일의 파일간 연결공법으로 용접이음과 볼트이음을 이용한 기계적 이음들이 적용되고 있으나 시공과정 등에서 품질 및 성능 확보에 어려움이 발생할 수 있다. 본 연구는 기존 PHC파일 연결부가 가지는 단점을 개선하고 PHC 파일 연결부 성능을 확보할 수 있는 무용접 이음판형 기계적 PHC파일 연결부를 제안하고 비선형 구조해석과 실제 PHC파일 연결부 실험을 통하여 제안된 PHC 파일 연결부의 연결성능을 평가하였다. 제안된 PHC파일 연결부의 비선형 구조해석 결과 연결부는 휨, 압축, 인장, 전단, 편심압축 하중 상태에서 충분한 연결성능을 확보하는 것으로 평가되었으며, 실제 휨하중 재하실험에서 PHC파일의 균열 및 휨 모멘트 수준 이상에서도 안정적인 선형거동을 가지고 있는 것으로 나타났다. 따라서 제안한 무용접 이음판형 기계적 PHC파일 연결부는 충분한 연결성능을 확보할 수 있는 것으로 판단된다.

220kV XLPE CABLE 접속함용 Al-Cu 이종접속슬리브 개발 (Development of Friction Welded Al to Cn Bimetallic Sleeve for 220kV XLPE Cable Termination & Joint)

  • 김현주;박정기;박성민
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.93-93
    • /
    • 2010
  • We developed friction welded bimetallic sleeve for 220kV aluminum conductor XLPE cable. Not only friction welded bimetallic sleeve for Termination(EB-A, EB-G) but also friction welded sleeve for Joint of Al to Cu conductor was developed regardless of this project. Generally, friction welded sleeve used to connect Al conductor cable to Cu conductor cable and used for improvement of mechanical property of terminal by offer the copper side of friction welded bimetallic sleeve at the Termination. Connection method for Al-Cu conductor has mainly used friction welding at the solid state, because it is difficult to connect by using conventional welding method. this investigation introduces development of friction welded bimetallic sleeve by friction welding and test result of 220kV Al conductor XLPE cable and accessories using friction welded sleeve.

  • PDF

개선된 엑세스 홀 형상을 갖는 WUF-W접합부의 실험을 통한 내진성능평가 (Experimental Evalutation of the Seismic Performance of WUF-W Moment Connections with a Modified Access Hole)

  • 한상환;정진;문기훈;김진원
    • 한국지진공학회논문집
    • /
    • 제16권6호
    • /
    • pp.21-28
    • /
    • 2012
  • Welded Unreinforced Flange-Welded Web (WUF-W) connection is one of Special Moment Frame (SMF) specified in ANSI/AISC-358. From the experimental test of WUF-W connection specimens conducted by the previous study, fracture occurred in the beam flange before achieving total inter-story drift angle of 0.04radian required for Special Moment Frames (SMF) system even though the specimens satisfied the design and detailing requirement specified in ANSI/AISC-358. These results are estimated as problem of the access hole geometry. In this study, a full-scale WUF-W connection specimen was made with a modified access hole geometry, and tested with the same test setting and loading as the previous test. From test results, the deformation capacity of the tested WUF-W connection specimen exceeded 4%, which is required for connections in SMF system. Comparing with the WUF-W specimens of the previous study, the strain demand of the beam flange in the tested specimen was decreased and energy dissipation capacity of the specimen was improved.

WUF-W 접합부의 액세스 홀 형상변수 타당성 평가를 위한 경험식 제안 (Empirical Equations for Checking Validity of Access Hole Parameters for WUF-W Connections)

  • 한상환;윤용
    • 한국강구조학회 논문집
    • /
    • 제29권4호
    • /
    • pp.303-310
    • /
    • 2017
  • WUF-W 접합부는 부재의 접합이 모두 용접으로 이루어진 접합부이며, 특수모멘트골조(SMF) 인증접합부 중 하나이다. 하지만 선행 연구들을 통해 일부 WUF-W 접합부 실험체가 4% 층간변위비의 특수모멘트골조(SMF) 요구성능을 만족하지 못하였으며, 이는 액세스 홀 형상과 연관이 있음이 보고되었다. 본 연구에서는 비선형 유한요소 해석을 이용하여 WUF-W 접합부의 요구성능을 만족하기 위한 주요 액세스홀 형상변수의 허용범위를 결정하였다. 또한 WUF-W 접합부 설계과정에서 주요 액세스 홀 형상변수의 타당성을 평가할 수 있는 간단한 경험식을 제안하였다.

Numerical cyclic behavior of T-RBS: A new steel moment connection

  • Ataollahi, Saeed;Banan, Mohammad-Reza;Banan, Mahmoud-Reza
    • Steel and Composite Structures
    • /
    • 제21권6호
    • /
    • pp.1251-1264
    • /
    • 2016
  • After observing relatively poor performance of bolted web-welded flange beam-to-column connections during 1994 Northridge earthquake, various types of connections based on two concepts of: (i) strengthening the connection; and (ii) weakening the beam ends were proposed. Among these modified or newly proposed connections, bolted T-stub connection follows the concept of strengthening. One of the connections with the idea of weakening the beam ends is reduced beam section (RBS). In this paper, finite element simulation is used to study the cyclic behavior of a new proposed connection developed by using a combination of both mentioned concepts. Investigated connections are exterior beam-to-column connections designed to comply with AISC provisions. The results show that moment capacity and dissipated energy of the new proposed connection is almost the same as those computed for a T-stub connection and higher than corresponding values for an RBS connection.