• 제목/요약/키워드: Welded Beam flange Connection

검색결과 39건 처리시간 0.03초

Numerical cyclic behavior of T-RBS: A new steel moment connection

  • Ataollahi, Saeed;Banan, Mohammad-Reza;Banan, Mahmoud-Reza
    • Steel and Composite Structures
    • /
    • 제21권6호
    • /
    • pp.1251-1264
    • /
    • 2016
  • After observing relatively poor performance of bolted web-welded flange beam-to-column connections during 1994 Northridge earthquake, various types of connections based on two concepts of: (i) strengthening the connection; and (ii) weakening the beam ends were proposed. Among these modified or newly proposed connections, bolted T-stub connection follows the concept of strengthening. One of the connections with the idea of weakening the beam ends is reduced beam section (RBS). In this paper, finite element simulation is used to study the cyclic behavior of a new proposed connection developed by using a combination of both mentioned concepts. Investigated connections are exterior beam-to-column connections designed to comply with AISC provisions. The results show that moment capacity and dissipated energy of the new proposed connection is almost the same as those computed for a T-stub connection and higher than corresponding values for an RBS connection.

패널존 강도 및 보 웨브 접합방식이 RBS 철골 모멘트접합부의 내진거동에 미치는 영향에 관한 연구 (Cyclic Seismic Performance of Reduced Beam Section Steel Moment Connections: Effects of Panel Zone Strength and Beam Web Connection Type)

  • 이철호;전상우;김진호
    • 한국지진공학회논문집
    • /
    • 제7권3호
    • /
    • pp.69-77
    • /
    • 2003
  • 본 연구는 8개의 RBS(reduced beam section) 내진 철골모멘트접합부의 실물대 실험결과를 요약한 것이다. 실험의 주요변수는 보 웨브 접합법 및 패널존 강도를 택하였다. 균형 패널존 시험체는 접합부의 내진성능을 감소시키지 않으면서, 보와 패널존이 함께 균형적으로 지진에너지를 소산시키도록 설계하여 값비싼 패널존 보강판(doubler plates)의 수요를 줄이고자 시도한 것이다. 보 웨브를 용접한 시험제는 모두 특별 연성모멘트골조에서 요구되는 접합부 회전능력을 충분히 발휘하였다. 반면 보 웨브를 볼트 접합한 시험체는 조기에 스캘럽을 가로지르는 취성파단이 발생하는 열등한 성능을 보였다. 보 그루브 용접부 자체의 취성파괴가 본 연구에서와 같이 양질의 용접에 의해 방지되면, 스켈럽 부근의 취성파단이 다음에 해결해야 할 문제로 대두되는 경향을 보인다. 보 웨브를 볼팅한 경우에 접합부 취성파단의 빈도가 월등히 높은 이유를 실험 및 해석결과를 토대로 제시하였다. 측정된 변형도 데이터에 의할 때, 접합부의 전단력 전달메카니즘은 흔히 가정하는 고전 휨이론에 의한 예측과 전혀 다르다. 이는 전통적 보 웨브 설계법을 재검토할 필요가 있음을 시사하는 것이다. 아울러, 접합부에서 요구되는 바람직한 거동기준을 제시하고 이를 근거로 균형 패널존의 강도범위에 대한 예비적 추정치를 제시하였다.

고강도강 기둥(SM570) 보 용접접합부의 탄소성거동에 관한 실험적 연구 -스캘럽상세와 패널강성을 중심으로- (An Experimental Study on the Elasto-Plastic Behavior of High Strength Column to Beam Welded Connection)

  • 김종락;김성배
    • 한국강구조학회 논문집
    • /
    • 제12권5호통권48호
    • /
    • pp.487-494
    • /
    • 2000
  • 고강도강 기둥-보 접합부는 용접방법에 따라 응력집중 및 균열의 발생진전에 큰 차이가 있다. 그러므로 공장제작형 디테일에 대한 내력과 인성, 용접접합부의 소성변형 능력과 패널의 강성에 의한 변형능력의 차이 등을 비교 검토하여 설계자료로 제시하고자 한다. 실험결과는 다음과 같다. 첫째, 누적소성율과 소성변형배율, 내력상승을 모두 논스캘럽이 스캘럽 시험체 보다, 약패널이 강패널 보다 우수한 것으로 나타났다. 둘째, 시험체의 2차균열 발생은 스캘럽 단부에서 발생하였으나, 논스캘럽 시험체는 보플렌지 용접 본드부에서 발생하여 집합부 상세에 따라 상이한 경향을 나타내었다.

  • PDF

바닥슬래브를 고려한 용접철골모멘트접합부의 내진보강 (Seismic Retrofit of Welded Steel Moment Connections Considering the Presence of Composite Floor Slabs)

  • 이철호;김성용
    • 한국강구조학회 논문집
    • /
    • 제29권1호
    • /
    • pp.25-36
    • /
    • 2017
  • 1994년 노스리지 지진 당시 발생한 용접모멘트 접합부의 취성파괴는 주로 보 하부 플랜지에서 발생하였다. 특히 국내 기존 용접철골모멘트 접합부의 경우 과다한 전단스터드 배치에 따른 의도치 않은 합성작용로 인해 지진 내습 시 보 하부 플랜지의 취성파단이 더욱 우려되는 실정이다. 본 논문에서는 합성효과로 인한 접합부 성능저하를 개선하기 위한 목적으로 중량전단탭/수평헌치/삼각헌치로 보강된 접합부 및 RBS가 도입된 접합부에 대한 실험을 실시하였다. 통상 기존 접합부 상부 플랜지의 수정이 불가하다는 점을 고려하여, 본 연구에서는 보 하부 플랜지에만 수평/삼각헌치를 보강하거나 RBS를 도입하여 이 때의 내진성능을 평가하였다. 실물대 실험 결과 수평/삼각헌치 혹은 중량전단탭으로 보강한 실험체는 모두 합성작용으로 인한 부작용을 극복하고 특수모멘트접합부가 요구하는 수준 이상의 소성회전각 5%이상을 발현함을 확인하였다. 또한 SRC 기둥에 RBS를 도입할 경우 접합부에 소요되는 변형의 대부분을 RBS측에서 일어나도록 유도함으로써 SRC기둥에 발생하는 손상을 방지하는 효과가 있음을 규명하였다. 이 중 중량전단탭 보강에 따른 접합부의 거동을 분석하기 위하여 추가의 수치해석 연구를 실시하였으며, 제시한 각각의 보강안에 대한 권장상세를 제시하였다.

바닥슬래브에 의해 구속된 철골 모멘트접합부의 내진보강에 관한 실험적 연구 (Experimental Study on Seismic Retrofit of Steel Moment Connections Considering Constraint Effect of the Floor Slab)

  • 오상훈;김영주;문태섭
    • 한국강구조학회 논문집
    • /
    • 제16권2호통권69호
    • /
    • pp.247-255
    • /
    • 2004
  • 본 실험프로그램은 슬래브가 있는 합성보의 내진성능향상을 위해 기존 모멘트접합부의 내진보강 방법을 개발을 목적으로 수행하였다. 반복하중을 통해 5개의 실대형 합성실험체에 대한 실험을 수행하였다. 각형강관기둥과 H형강보로 이루어진 기존의 다이아프램접합부가 RBS 또는 개량수평스티프너를 통해서 하부플랜지에만 내진 보강되었다. 제안한 보강접합부의 효율성을 조사하였다. 실험결과 하부플랜지에만 RBS를 적용한 접합부는 부족한 변형성능을 나타냈지만, 개량스티프너를 적용한 합성보 접합부는 내진성능을 향상시켰다.

Experimental and numerical assessment of beam-column connection in steel moment-resisting frames with built-up double-I column

  • Dehghan, Seyed Mehdi;Najafgholipour, Mohammad Amir;Ziarati, Seyed Mohsen;Mehrpour, Mohammad Reza
    • Steel and Composite Structures
    • /
    • 제26권3호
    • /
    • pp.315-328
    • /
    • 2018
  • Built-up Double-I (BD-I) columns consist of two hot rolled IPE sections and two cover plates which are welded by fillet welds. In Iran, this type of column is commonly used in braced frames with simple connections and sometimes in low-rise Moment Resisting Frames (MRF) with Welded Flange Plate (WFP) beam-column detailing. To evaluate the seismic performance of WFP connection of I-beam to BD-I column, traditional and modified exterior MRF connections were tested subjected to cyclic prescribed loading of AISC. Test results indicate that the traditional connection does not achieve the intended behavior while the modified connection can moderately meet the requirements of MRF connection. The numerical models of the connections were developed in ABAQUS finite element software and validated with the test results. For this purpose, moment-rotation curves and failure modes of the tested connections were compared with the simulation results. Moreover to avoid improper failure modes, some improvements of the connections were evaluated through a numerical study.

Suggesting double-web I-shaped columns for omitting continuity plates in a box-shaped column

  • Saffari, Hamed;Hedayat, Amir A.;Goharrizi, Nasrin Soltani
    • Steel and Composite Structures
    • /
    • 제15권6호
    • /
    • pp.585-603
    • /
    • 2013
  • Generally the required strength and stiffness of an I-shaped beam to the box-shaped column connection is achieved if continuity plates are welded to the column flanges from all sides. However, welding the forth edge of a continuity plate to the column flange may not be easily done and is normally accompanied by remarkable difficulties. This study was aimed to propose an alternative for box columns with continuity plates to diminish such problems. For this purpose a double-web I-shaped column was proposed. In this case the strength and rotational stiffness of the connection was provided by nearing the column webs to each other. Finite element studies on about 120 beam-column connections showed that the optimum proportion of the distance between two column webs and the width of the column flange (parameter ${\beta}$) was a function of the ratio of the beam flange width to the column flange width (parameter ${\alpha}$). Hence, based on the finite element results, an equation was proposed to estimate the optimum value of parameter ${\beta}$ in terms of parameter ${\alpha}$ to achieve the highest connection performance. Results also showed that the strength and ductility of post-Northridge connections of such columns are in average 12.5 % and 54% respectively higher than those of box-shaped columns with ordinary continuity plates. Therefore, a double-web I-shaped column of optimum arrangement might be a proper replacement for a box column with continuity plates when beams are rigidly attached to it.

더블앵글로 접합된 골조의 수평처짐 (Story Drift of a Frame with Column Flange Bolted-Beam Web Welded Double Angle Connections)

  • 양재근;김호근;김기환
    • 한국공간구조학회논문집
    • /
    • 제3권3호
    • /
    • pp.95-103
    • /
    • 2003
  • Frame is one of the most commonly used structural systems for the resistance of applied loads. Many researchers have recently conducted their studies to investigate the effect of several parameters such as the connection flexibility, boundary condition of each support, beam-to-column stiffness ratio. These parameters play important roles on the characteristic behavior of frames. A simplified spring model is proposed to obtain the story drifts of frames with various beam-to-column connection stiffnesses in this research. A point bracing system with adequate spring stiffness is also suggested to establish the relationship between the applied load and the resisting translational spring stiffness within the limit state of story drift.

  • PDF

T-스티프너 보강 콘크리트충전 각형강관 기둥-H형강 보 접합부의 인장거동 (Tensile Behavior of CFT Column-to-H beam Connections with External T-shaped Stiffeners)

  • 강창훈;신경재;오영석;문태섭
    • 한국강구조학회 논문집
    • /
    • 제14권1호
    • /
    • pp.121-130
    • /
    • 2002
  • This paper presents the tensile behavior of a Concrete-Filled Square Steel Tubular (CFT) column to H-beam welded connections. These connections were externally reinforced with T-shaped stiffeners at the junction of CFT column and beam. The tensile loading tests of eighteen tee-joint connections and finite element analysis using ANSYS were carried out. The main parameters of tests are as follows: 1) the thickness of Square Steel Tubular Column : 6 mm, 9 mm, 2) the strength ratios of tensile strength of horizontal stiffeners to tensile strength of beam flange : 70 %, 100 %, 150 %, 3) the strength ratios of shear strength of vertical stiffeners to tensile strength of beam flange : 80 %, 115 %, 160 %. The results of the tests demonstrate that overall behavior and failure modes of all the specimens are governed mainly by the horizontal stiffeners rather than the vertical stiffeners, and the vertical stiffener played only a role in transferring load introduced from beam to column.

Racking shear resistance of steel frames with corner connected precast concrete infill panels

  • Hoenderkamp, J.C.D.;Snijder, H.H.;Hofmeyer, H.
    • Steel and Composite Structures
    • /
    • 제19권6호
    • /
    • pp.1403-1419
    • /
    • 2015
  • When precast concrete infill panels are connected to steel frames at discrete locations, interaction at the structural interface is neither complete nor absent. The contribution of precast concrete infill panels to the lateral stiffness and strength of steel frames can be significant depending on the quality, quantity and location of the discrete interface connections. This paper presents preliminary experimental and finite element results of an investigation into the composite behaviour of a square steel frame with a precast concrete infill panel subject to lateral loading. The panel is connected at the corners to the ends of the top and bottom beams. The Frame-to-Panel-Connection, FPC4 between steel beam and concrete panel consists of two parts. A T-section with five achor bars welded to the top of the flange is cast in at the panel corner at a forty five degree angle. The triangularly shaped web of the T-section is reinforced against local buckling with a stiffener plate. The second part consists of a triangular gusset plate which is welded to the beam flange. Two bolts acting in shear connect the gusset plate to the web of the T-section. This way the connection can act in tension or compression. Experimental pull-out tests on individual connections allowed their load deflection characteristics to be established. A full scale experiment was performed on a one-storey one-bay 3 by 3 m infilled frame structure which was horizontally loaded at the top. With the characteristics of the frame-to-panel connections obtained from the experiments on individual connections, finite element analyses were performed on the infilled frame structures taking geometric and material non-linear behaviour of the structural components into account. The finite element model yields reasonably accurate results. This allows the model to be used for further parametric studies.