• Title/Summary/Keyword: Weight filter

Search Result 463, Processing Time 0.023 seconds

Effects of Membrane Filter and Sucrose Concentrations on the Growth of Balloon Flower (Platycodon grandiflorum A. DC.) Plantlets In Vitro (Membrane Filter와 Sucrose 농도가 도라지(Platycodon grandiflorum A. DC.) 기내 배양묘의 생장에 미치는 영향)

  • Choi, So-Ra;Kim, Myung-Jun;Eun, Jong-Seon;Ahn, Min-Sil;Lim, Hoi-Chun;Ryu, Jeong;You, Dong-Hyun
    • Journal of Plant Biotechnology
    • /
    • v.31 no.3
    • /
    • pp.209-217
    • /
    • 2004
  • The shoots of balloon flower (Platycodon grandiflorum A. DC.) in vitro germinated from seeds were cultured on MS basal medium containing 0.1 mg/L NAA under the various sucrose concentrations and with/without membrane filter (MF) on the lid of vessel. The growth responses were checked to obtain healthy plantlets. The $CO_2$ and $C_2$H$_4$ concentration in vessel without MF were higher than those with MF. The $CO_2$ concentration without MF was increased as days in culture went by whereas the $C_2$H$_4$ concentration was decreased. The plant growth with MF and high sucrose concentration was good. Fresh and dry weight of plantlets cultured in sucrose 4.5% with MF were higher than those in no sucrose without MF. Also the content of chlorophyll of plantlets cultured with MF was high and the content of sugar was shown a similar results and a remarkable difference between MF treatments, especially. Stomata cultured with MF was closer than that without MF and mesophyll of leaf were more developed with MF or in high sucrose concentration. When the plantlets were transplanted in the pot at 25$\pm$2$^{\circ}C$, 75% relative humidity and low PPFD (photosynthetic photon flux density), the percentage of survival after 13 days without MF was 0% but it was 100% with MF regardless of sucrose concentrations.

Study of Paprika Growth Characteristic on Covering Selective Light Transmitting Filter in Greenhouse (선택적 광 투과에 따른 파프리카 생육특성 연구)

  • Kang, D.H.;Kim, D.E.;Lee, J.W.;Hong, S.J.
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.23 no.1
    • /
    • pp.59-66
    • /
    • 2021
  • This study aimed to a basic research for the development of dye-sensitized solar cells that the wavelength band required for crop growth is passed, and the wavelength band that is not necessary for crop growth can be used for the generation of electricity. The transmissivity according to the illuminance was about 10% higher in the Blue filter and the Green filter than in the Red filter, but the transmissivity according to the PPFD was about 10% higher in the Red filter and the Blue filter than in the Green filter. In addition, the greenhouse attached with 30% infrared blocking filter was predicted to have a lower air temperature than other greenhouses, but it was investigated that there was no significant difference. Therefore, it was investigated that the application of the infrared cut filter would not be appropriate in a greenhouse that controls the temperature by opening a window. As a result of investigating, it was found that the Green and Blue filter greenhouses had the severe overgrowth and the stems grew weaker. The fresh weight of paprika in the infrared blocking filter greenhouse was the highest at 678.9g, and the growth of Red filter and the control greenhouses was relatively poor. Photosynthetic rate, amount of transpiration, and stomatal conductivity were the infrared blocking filter and control greenhouse higher than others. On the other hand, the water use efficiency did not show a big difference.

Design of a Narrow-Band Bandpass Filter Using Microstrip Open-Loop Resonators With Coupled and Crossing Lines (결합 및 교차 선로를 갖는 마이크로스트립 개방루프 공진기를 이용한 협대역 대역통과 여파기 설계)

  • 안승현;이영구;이문수
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.5 no.5
    • /
    • pp.1011-1016
    • /
    • 2001
  • In this paper, a narrow-band bandpass filter using microstrip open-loop resonators with coupled and crossing lines is designed and fabricated. This filter has many advantages such as compact in size, low weight and the characteristic of the elliptic-function narrow-band bandpass filtering. The configuration consists of two identical microstrip open loop resonators, coupled line and crossing line. By using open loop resonators, the size of the filter can be reduced about 50% compared with the ring resonators. A crossing line gives two notchs in the stopband, which have sharp selectivity in the passband. Centered at 2.455GHz, the calculated microstrip bandpass filter shows a bandwidth of 1.22%, which makes it very attractive for application in the wireless LAN. The filter is fabricated by photo-etching process. The fabricated bandpass filter shows that the bandwidth is 0.85% for 2.458GHz and the size is only $2.6cm\times1cm$.

  • PDF

Discriminative Weight Training for Gender Identification (변별적 가중치 학습을 적용한 성별인식 알고리즘)

  • Kang, Sang-Ick;Chang, Joon-Hyuk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.27 no.5
    • /
    • pp.252-255
    • /
    • 2008
  • In this paper, we apply a discriminative weight training to a support vector machine (SVM) based gender identification. In our approach, the gender decision rule is expressed as the SVM of optimally weighted mel-frequency cepstral coefficients (MFCC) based on a minimum classification error (MCE) method which is different from the previous works in that different weights are assigned to each MFCC filter bank which is considered more realistic. According to the experimental results, the proposed approach is found to be effective for gender identification using SVM.

A Novel Equivalent Wiener-Hopf Equation with TDL coefficient in Lattice Structure

  • Cho, Ju-Phil;Ahn, Bong-Man;Hwang, Jee-Won
    • Journal of information and communication convergence engineering
    • /
    • v.9 no.5
    • /
    • pp.500-504
    • /
    • 2011
  • In this paper, we propose an equivalent Wiener-Hopf equation. The proposed algorithm can obtain the weight vector of a TDL(tapped-delay-line) filter and the error simultaneously if the inputs are orthogonal to each other. The equivalent Wiener-Hopf equation was analyzed theoretically based on the MMSE(minimum mean square error) method. The results present that the proposed algorithm is equivalent to original Wiener-Hopf equation. The new algorithm was applied into the identification of an unknown system for evaluating the performance of the proposed method. We compared the Wiener-Hopf solution with the equivalent Wiener-Hopf solution. The simulation results were similar to those obtained in the theoretical analysis. In conclusion, our method can find the coefficient of the TDL (tapped-delay-line) filter where a lattice filter is used, and also when the process of Gram-Schmidt orthogonalization is used. Furthermore, a new cost function is suggested which may facilitate research in the adaptive signal processing area.

A Study on Use and improvement of Construction type infiltration gallery (조립식 집수암거의 개량과 이용에 관한 연구)

  • 함준호
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.14 no.2
    • /
    • pp.2593-2602
    • /
    • 1972
  • Plastic pipes Wrapped with synthetic filter are recently used for drainage or Collecting of Underground water. But it's use is possible only for small size of diameter less than 300mm, because large size plastic pipes are not readily availabe. For large diameter infiltration gallery, porous concrete pipes are now used, but it's heavy weight brings difficulties in making, moving and setting of the pipes. With it's conventional method of filter setting, fine sands are brought into the pipes to make trouble to lifting pumps and channels Therefore, initial construction cost and maintenance cost become high. To solve-this problem, new method is developed and tested. Small PVC pipes(diameter 14mm) are assembled at the site of construction to newly devised I beam type circls. The size of circular inpiltration gallery is optionally determined by I beam type circle which support small PVC pipes and is made of PVC amterial. This gallery are wrappd with syntheitc filter to prevent sand instruction. In this test, the diameter of 300, 400, 500mm were used. I beam type circles were made with PVC plated with thickness. t=6, 9, 12mm. Water quantity collected through the PVC circulor gallery are measured and the strengths of the gallery. 1. Allowable setting depth of gallery pipe below graund for the case of t=6mm, D=500mm is 2.72m. 2. Collected water quantity depends on soil texture, depth of water grandient of water surface, filter material angle of setting etc. 3. About 126% of water quantity collected from the one gallery pipe measured in two gallery pipes of two parallel installation.

  • PDF

A Study on Cascade Filter Algorithm for Random Valued Impulse Noise Elimination (랜덤 임펄스 잡음제거를 위한 캐스케이드 필터 알고리즘에 관한 연구)

  • Yinyu, Gao;Kim, Nam-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.3
    • /
    • pp.598-604
    • /
    • 2012
  • Image signal is corrupted by various noises in image processing, many studies are being accomplished to restore those images. In this paper, we proposed a cascade filter algorithm for removing random valued impulse noise. The algorithm consists two steps that noise detection and noise elimination. Variance of filtering mask and center pixel variance are calculated for noise detection, and the noise pixel is replaced by estimated value which first apply switching self adaptive weighted median filter and finally processed by modified weight filter. Considering the proposed algorithm only remove noise and preserve the uncorrupted information that the algorithm can not only remove noise well but also preserve edge.

Characteristics of HEPA Filter Waste Compactor Developed by KAERI and Comparison with Japan's and U.S.A's Compactors (KAERI 개발 HEPA 필터폐기물 압축처리장치 특성 및 일본, 미국 압축처리장치와의 비교)

  • 이강무;안섬진;배상민;손종식;홍권표;김홍태
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.149-157
    • /
    • 2003
  • The HEPA filter waste (Hexahedron, $610{\times}610{\times}292mm$, 20kg), which is used for the ventilation system in the nuclear industries, has relatively large volume to compare with it's weight. Due to the large volume of HEPA filter waste, it needs the large storage and/or disposal space and managing cost during the long period of storage and management. Many countries use the compactor to reduce the volume of HEPA filter waste. On this paper we introduce the new type compactor developed by KAERI with the characteristical comparison to the Japan's and U.S.A's compactors.

  • PDF

Composting and trickling filter for treatment of olive mill waste

  • Li, Xinhua;Lin, Ching-Chieh;Sweeney, Daniel;Earl, Jessica;Hong, Andy
    • Advances in environmental research
    • /
    • v.2 no.2
    • /
    • pp.131-141
    • /
    • 2013
  • Agricultural practice and improper waste disposal in developing regions have resulted in environmental degradation in land and waters, for which low-cost, proven solutions are needed. We demonstrate in the laboratory the applications of composting and trickling filter techniques to treat olive mill wastes that can be implemented in the West Bank and other regions of the world. To a pomace waste sample from a California mill, we amended with saw dust (wood carbon source) and baking soda ($NaHCO_3$ alkalinity) at weight ratios of waste/wood/$NaHCO_3$ at 70:27:1 and composted it for periods of 11 and 48 days; the compost was used as an additive to potting soil for transplanting. The pomace sample was also blended into slurry and introduced to a water-circulating pond and trickling filter system (P/TF) to examine any inhibitive effect of the pomace on biological removal of the organic waste. The results showed the compost-amended potting soil supported plant growth without noticeable stress over 34 days and the P/TF system removed BOD and COD by >90% from the waste liquid within 2 days, with a first-order rate constant of 1.9 $d^{-1}$ in the pond. An onsite treatment design is proposed that promises implementation for agricultural waste disposal in developing regions.

MSE Convergence Characteristic over Tap Weight Updating of RBRLS Algorithm Filter (RBRLS 알고리즘의 탭 가중치 갱신에 따른 MSE 성능 분석)

  • 김원균;윤찬호;곽종서;나상동
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 1999.11a
    • /
    • pp.248-251
    • /
    • 1999
  • We extend the sue of the method of least square to develop a recursive algorithm for the design of adaptive transversal filters such that, given the least-square estimate of this vector of the filter at iteration n-1, we may compute the updated estimate of this vector at i(oration n upon the arrival of new data. The RLS algorithm may be viewed as a special case of the Kalman filter. Indeed this special relationship between the RLS algorithm and the Kalman filter is considered. We begin the development of the RLS algorithm by reviewing some basic relations that pertain to the method of least squares. Then, by exploiting a relation in matrix algebra known as the matrix inversion lemma, we develop the RLS algorithm. An important feature of the RLS algorithm is that it utilizes information contained in the input data, extending back to the instant of time when the algorithm is initiated. The resulting rate of convergence is therefore typically an order of magnitude faster than the simple LMS algorithm. This improvement in performance, however, Is achieved at the expensive of a large increase in computational complexity.

  • PDF