• 제목/요약/키워드: Weight Measurement

검색결과 1,918건 처리시간 0.032초

수압측정 방식의 요류검사 진단매개변수의 정확도 평가 (Accuracy evaluation of diagnostic parameters estimated by uroflowmetry technique measuring hydraulic pressure)

  • 김경아;최성수;김성식;김군진;박경순;차은종
    • 센서학회지
    • /
    • 제16권6호
    • /
    • pp.413-418
    • /
    • 2007
  • Uroflowmetry is of great convenience to diagnose benign prostate hypertrophy common in aged men. The urinary flow rate is obtained by weight measurement using load cell, however, sensitive to impact noise. An alternative technique was recently proposed to measure hydraulic pressure instead of weight and demonstrated to introduce significantly reduced noise. In this paper, we described the measured diagnostic parameters between the weight and pressure measuring techniques in 10 normal men. The weight and pressure signals were simultaneously acquired during urination, converted into urine volumes, then differentiated to obtain flow rate signals, which showed very similar waveforms. Diagnostic parameters evaluated by pressure measuring technique were well correlated with the standard weight measuring technique (correlation coefficient > 0.99). Therefore, the new uroflowmetry based on hydraulic pressure measurement can provide accurate diagnostic parameters, which would be clinically valid.

넙다리 뒤근육의 길이와 정적 기립균형과의 상관성 분석 (The Analysis on Relation between Hamstring Length and Static Uprighting Balance)

  • 남건우
    • 대한물리치료과학회지
    • /
    • 제18권1호
    • /
    • pp.51-60
    • /
    • 2011
  • Purpose: The purpose of this study was to investigate hamstring length during static uprighting position using weight distribution ratio. Methods: Ninety-six volunteers(56 males) were participated. The active knee extension test(AKE) was measured 3 times on both legs. The mean score of AKE was obtained. Then, the measurement of weight distribution ratio was observed 3 times on both legs, and its mean value was also calculated. Subjects were divided four groups based on their hamstring length measurement; both hamstring shortening group, left hamstring shortening group, right hamstring shortening group and normal hamstring length group. One-way ANOVA was employed to analyse collected data. Pearson's correlation was also hired to see any relationship between the hamstring length and the weight distribution. Results: In anterior/left area and posterior/right area, both hamstring shortening group left hamstring shortening group were superior to right hamstring shortening group and normal hamstring length group. Significant difference was existed statistically(p<.05) between groups. The correlation analysis between hamstring length and weight distribution ratio has not been shown any significant findings(Pant/post=0.733, Plt/rt=0.135). Conclusion: The results of the study may be applied to therapeutic management in posture and movement skill in musculoskeletal physical therapy.

  • PDF

압력 측정에 의한 요량 계측의 유용성 분석 (Validation of Urine Volume Evaluation by Hydraulic Pressure Measurement)

  • 김경아;최성수;이인광;박경순;김원재;이태수;차은종
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권4호
    • /
    • pp.577-584
    • /
    • 2007
  • Uroflowmetry is non-invasive and easily performed to diagnose benign prostatic hypertrophy(BPH) frequent in aged men. Weight change during urination is usually measured to estimate the urinary flow rate by a load cell, but sensitive to any impacts against the bottom of the container, leading to unnecessary noise generation. Moreover, load cells are relatively expensive raising the production cost. The present study proposed a new technique, measuring hydraulic pressure on the bottom of the urine container to evaluate the urinary volume. Low cost pressure transducer enabled almost perfectly linear relationship between the urine volume and the hydraulic pressure. During both the simulated and human urination experiments, variance of the pressure signal was more than 50% smaller than the weight signal acquired by a load cell, which demonstrated that the impact noise was decreased to a great degree by pressure compared to weight measurement.

유아복의 KS 치수체계 개정을 위한 제안 연구 (A Study on the Suggestion for the Revision of Standard Sizing System for Infant Clothing)

  • 정명숙;서추연;이진희
    • 한국의류산업학회지
    • /
    • 제16권1호
    • /
    • pp.118-127
    • /
    • 2014
  • This study proposed a revision of standard sizing system for infant clothing to provide exact information for consumers and manufacturers. The size designation was set up by compensating the defect of existing system. Basic body measurement and reference body measurement were analysed according to size designation. The ages of the infants ranged from 0 to 36 month in accordance with safety standard of KC Self-Regularity Safety Confirmation. The results are as follows: Size designation for infant clothing was based on height that was basic body measurement. Chest girth, waist girth, head girth, arm length, foot length and weight were also analysed according to age of the month. It was proposed that height could be written alone and height with age of month did together for size designation. Size intervals of basic and reference body measurements were fixed as follows: size intervals are 5 cm in height, 2 cm in chest girth, 2 cm in waist girth, 1 cm in head girth, 2 cm in arm length, 0.5 cm in foot length and 2 kg in weight. The distributions of height and chest girth showed normal distributions. As height was taller, chest girth was also bigger. But the distribution of waist girth didn't show remarkable change with age of month. The distributions of arm length and weight showed remarkable difference with growth in 0~9 months, but the amount of growth variation got less in 12~18 months.

The Development of Coating Weight Model and Control Logics in Continuous Galvanizing Line

  • Kook, Chae-Hong;Tae, Shin-Ki
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.121.5-121
    • /
    • 2001
  • For the last decade, remarkable progress in the coating weight uniformity of hot dip galvanized product has been made to overcome the tightening quality constraints and produce cost-effective galvanized products. This progress results from research and development works for more efficient air knife, more accurate model of coating process, more precise measurement of coating weight and more efficient control logics. The activities for an efficient mathematical model to predict coating weight and several control logics which has been implemented on the No.1 CGL, No. 2 CGL, and PGL at KwangYang Steel Works are reviewed in this article.

  • PDF

광감쇄를 이용한 마모입자의 농도 측정 (Wear Debris Concentration Measurement by Laser Beam Attenuation)

  • 강기호;손정영;전형욱;윤의성;안효석
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1990년도 제12회 학술강연회초록집
    • /
    • pp.58-62
    • /
    • 1990
  • The size and concentration of wear debris in lubricating oil often reveal the operating condition of the rotating machinery. To evaluate the possible application of light attenuation measurement for the estimation of wear debris concentration in the lubricating oil, the light transmittance through the lubricating oil cell contaminated with various concentrations of diatomite particles was measured, the attenuation coefficient was estimated from the transmittance measurement and the coefficients were compared with those obtained from the scattering theory. The comparision showed good agreements between them. It is also noted that the experimentally determined attenuation coefficient showed almost linear relation with particle weight concentrations for the concentrations within the range of 2000 ppm. For the case of 0 ppm weight concentration of diatomite particles in the lubricating oil cell, the thickness of the cell required to give $100 \mu W$ light attenuation is 7.75 mm. This result indicates that the light attenuation method will be one of the possible candidates of machine failure diagnostic sensors for the estimation of wear debris concentration in the lubricating oil.

  • PDF

광감쇄를 이용한 마모입자의 농도 측정 (Wear Debris Coacentration Measurement by Laser Beam Attenuation)

  • 강기호;손정영;전형욱;윤의성;안효석
    • Tribology and Lubricants
    • /
    • 제6권2호
    • /
    • pp.94-98
    • /
    • 1990
  • The size and concentration of wear debris in lubricating oil often reveal the operating condition of the rotating machinery. To evaluate the possible application of light attenuation measurement for the estimation of wear debris concentration in the lubricating oil, the light transmittance through the lubricating oil cell contaminated with various concentrations of diatomire particles was measured, the attenuation coefficient was estimated from the transmittance measurement and the coefficients were compared with those obtained from the scattering theory. The comparision showed good agreements between them. It is also noted that the experimentally determined attenuation coefficient showed almost linear relation with particle weight coucentrations for the concentrations within the range of 2000 ppm. For the case of 0 ppm weight concentration of diatomire particles in the lubricating oil cell, the thickness of the cell required to give $100 \muW$ light attenuation is 7.75 mm. This result indicates that the light attenuation method will be one of the possible candidates of machine failure diagnostic sensors for the estimation of wear debris concentration in the lubricating oil.

임팩트 볼을 활용한 바닥충격음 측정 및 평가 (Floor Impact Noise Measurement and Evaluation Method Using Impact Ball)

  • 전진용;정정호
    • 한국소음진동공학회논문집
    • /
    • 제15권10호
    • /
    • pp.1160-1168
    • /
    • 2005
  • Floor impact noise isolation performance of reinforced concrete floors was investigated through new measurement method using impact bail. Strong impact force in Bow frequency band below 63 Hz of bang machine is not similar to human impact source and causes some problem in evaluating heavy-weight Impact noise but heavy-weight impact noise measurement and evaluation using impact ball which is very similar to human impact is more reliable than bang machine. Correction value on the background noise and sensitivity of residents should be considered on the floor impact noise evaluation classes.

삽입재 크기에 따른 코니컬 커터의 현장 내구성 평가 연구 (Durability evaluation depending on the insert size of conical Picks by the field test)

  • 최순욱
    • 한국터널지하공간학회 논문집
    • /
    • 제21권1호
    • /
    • pp.49-59
    • /
    • 2019
  • 본 연구는 로터리드럼커터에 적용된 두 종류의 코니컬 픽커터에 대한 현장시험을 통해 시험 전과 후의 육안조사와 중량감소 및 마모부피를 측정하여 코니컬 픽커터의 내구성을 비교 분석하였다. 육안조사를 통해 슬림 타입 코니컬 픽커터에서만 총 9개의 삽입재 손실이 나타남을 확인하였고 삽입재 보호를 위해 두부의 두께가 중요함을 알 수 있었다. 시험 전과 후의 픽커터의 중량손실과 마모부피는 헤비타입이 슬림타입에 비해 반이하로 작게 나타나 경암반에서 헤비타입이 더 유용함을 확인할 수 있었다. 픽커터의 마모손실을 판단할 때, 중량측정과 마모부피 측정결과의 상호 비교는 재료의 단위중량과 굴착에 의한 스폴링에 의해 차이가 나타날 수 있으므로 주의해야 할 것으로 판단된다.

벽식구조 표준시험동에서 중량충격음장에 관한 연구 (Investigation of the heavy-weight floor impact sound field in a testing building with bearing wall structure)

  • 유승엽;이신영;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.969-973
    • /
    • 2007
  • The heavy-weight floor impact sound field of the receiving room in a testing building with bearing wall structure was investigated using bang machine and impact ball. The sound field was investigated through the impact sound pressure level distribution by the field measurement and computational analysis. Predicted sound field using the computational analysis agree with measurement result in the low frequency band. Result shows that standard deviations of the single number rating value are about 2dB in each impact source. Particularly, impact sound pressure level at 120cm height in 63Hz octave band was 5dB lower than spatial averaging value. It was found that receiving positions in the ministry of construction and transportation notice should be reconsidered.

  • PDF