• 제목/요약/키워드: Weight Margin

검색결과 119건 처리시간 0.02초

단층RESIST의 미세패턴형성기술 (SUBMICRON TECHNOLOGY OF SINGLE LAYER PHOTO-RESIT)

  • 배경성;홍승각
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 전기.전자공학 학술대회 논문집
    • /
    • pp.315-318
    • /
    • 1988
  • PHOTO-RESIST 자체문제로인해 감소되는 최소해상력, 촛집심도여유 및 CRITICAL DIMENSION (C.D.) 조정여유도등을 연구하였다. 기존에 사용중인 PHOTO-RESIST(큰 분자량)와 PHOTO-RESIST자체내에 CONTRAST 촉진 물질(CEM)이 첨가된것(INNER CEM TYPE) 및 PHOTO-RESIST구성성분중 작은 분자량/좁은 분자량 산포가 형성된 RESIN 의 PHOTO-RESIST(LOW MOLECULAR WEIGHT CONTROL TYPE)등 세가지 PHOTO-RESIST를 사용 하여 상기의 항목을 분석하였다. INNER CEM TYPE 및 LOW MOLECULAR WEIGHT CONTROL TYPE의 PHOTO-RESIST는 기존에 사용중인 RESIST보다, 최소 RESOLUTION은 약 0.2 - 0.3 um, DEPOCUS MARGIN은 약 0.8 - 1.2 um 및 C.D. CONTROL LATITUDE 향상된 것 등이 우수하였다.

  • PDF

실적 함정의 중량추정 분석 연구 (A Study on the Analysis of the Weight Estimation of Built Naval Ships)

  • 김종철;고용석;김태훈
    • 한국군사과학기술학회지
    • /
    • 제19권4호
    • /
    • pp.526-535
    • /
    • 2016
  • In this study, the estimating weight data of eight leading ships of Korea navy were processed by comparing with the final weight data of their incline test results statistically, and are analyzed as follows; The maximum criteria of the weight margins of Korea naval ship in the preliminary and detailed design phases seem to be appropriate values, but the minimum criteria would be advisable to update more reasonable values. And, the limitation that the acceptable deviation of lightship weight should be 10 % of the lightship weight on a naval ship's ROC(Required Operational Capabilities) is recommended to be prohibited, because it comes from the weight estimation which has considerable uncertainty and it may also drop off design flexibility. Finally, the SWBS(Ship Work Breakdown System) groups which have larger deviation values in the estimating weight of naval ships are necessary to improve their accuracies, and to upgrade their weight database continuously.

서포트 벡터 기계에서 잡음 영향의 효과적 조절 (Support Vector Machines Controlling Noise Influence Effectively)

  • 김철응;윤민
    • 응용통계연구
    • /
    • 제16권2호
    • /
    • pp.261-271
    • /
    • 2003
  • 서포트 벡터 기계(Support Vector Machines, SVMs)에서의 일반화 오차의 경계는 훈련점들과 분리 초평면 사이의 최소의 거리에 의존한다. 특히, 소프트 마진 알고리즘은 목표 마진과 slack 벡터의 놈들에 의하여 경계가 결정된다. 이 논문에서는, 자료들에 있어서 잡음들에 의한 오염들을 직접적으로 고려하는 새로운 소프트 마진 알고리즘을 공식화하였다. 그리고, 수치적 예제를 통하여, 제안된 방법과 기존의 소프트 마진 알고리즘을 비교하였다.

사각 보행 로보트의 제작 및 균형추를 이용한 안정성 향상에 관한 연구 (A Development of 4-legged Walking Machine and the Enhancement of Static Stability Margin Using Balancing Weight)

  • 강신천;오준호;정경민
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1991년도 추계학술대회 논문집
    • /
    • pp.146-154
    • /
    • 1991
  • As the application of robotic systems expand its scope, more research efforts are given in providing mobility to the robotic systems so that they can travel across various paths including those with formidable obstacles such as stairways or rough terrains. Legged locomotion is mainly concerned because the walking motion, like that of animal behavior, has many advantages over wheel type or track type locomotion especially in rough terrain. Walking robot, in general, having a discrete number of legs, have inherently low static stability. Static stability can be increased to a certain degree, by improving walking method, but it has many limitations such as reduced travel speed. A very promising possibility lies in the use of balancing weight, nevertheless its actual implementation is very rare. In this study, a 4-legged walking machine is developed and the static stability margin is increased with the balancing weight. In the future, this robot will be used to take an experiment on the walking in mush terrain.

  • PDF

초고속 원심분리 회전축계의 최적설계 (An Optimum Design of a Rotor-Bearing Spindle System for a Ultra Centrifuge)

  • 김종립;윤기찬;박종권
    • 한국정밀공학회지
    • /
    • 제15권6호
    • /
    • pp.145-152
    • /
    • 1998
  • This paper presents an optimum design of a rotor-bearing spindle system for a ultra centrifuge (80,000 RPM) supported by ball bearings with nonlinear stiffness characteristics. To obtain the nonlinear bearing stiffnesses, a ball bearing is modeled in five degrees of freedom and is analyzed quasi-statically. The dynamic behaviors of the nonlinear rotor-bearing system are analyzed by using a transfer-matrix method iteratively. For optimization. we use the cost function that simultaneously minimizes the weight of a rotor and maximizes the separation margins to yield the critical speeds as far from the operating speed as possible. Augmented Lagrange Multiplier (ALM) method is employed for the nonlinear optimization problem. The result shows that the rotor-bearing spindle system is optimized to obtain 9.5% weight reduction and 21% separation margin.

  • PDF

수종의 상아질 접착제와 복합레진의 적합성에 관한 연구 (A STUDY ON THE COMPATIBILITY OF DENTIN ADHESIVES WITH COMPOSITE RESINS)

  • 박진성;권혁춘
    • Restorative Dentistry and Endodontics
    • /
    • 제20권1호
    • /
    • pp.214-234
    • /
    • 1995
  • The purpose of this work was to study the compatibility of several commercially available dentin adhesives with composite resins. In this study, V-shaped cavity preparations were created on both buccal and lingual surfaces of 60 extracted human premolars($3mm{\times}3mm{\times}2mm$ deep). Preparations were located such that the occlusal margins were on the enamel and the gingival margins were on the cementum(1mm below the CEJ). These specimens were randomly divided into three equal groups. Three dentin adhesives(Scotchbond Multi-Purpose, All Bond 2, Prisma Universal Bond 3)were applied to the cavity in accordance with each manufacturer's instructions. The teeth in each group were restored with four composite resins(Silux plus, Z100, Bisfil, Prisma TPH) in three increments, with each increment light-cured for 40 seconds. All specimens were exposed to 500 cycles of thermal stress. Specimens then placed in a silver nitrate solution(50% by weight) and stored in darkness for 24 hours. They were then immersed for 6 hours in photographic developing solution under flourescent light. Specimens were sectioned buccolingually through the center of the restoration and observed under a binocular stereoscope. To compare the marginal leakage, ANOVA and Dunkan's multiple range tests were used in analysis. Selected samples were further studied using scanning electron microscopy(XL20, Philips, The Netherlands). The results were as follows. 1. In all groups, the enamel margin showed significantly less leakage than the cementum margin. 2. No statistically significant differences were found in microleakage when composite resins were used with their proprietary dentin adhesives. 3. In comparison between dentin adhesives, Prisma Universal Bond 3 showed significantly less leakage at the enamel margin and Scotch bond multi-purpose showed significantly less leakage at the cementum margin than the other groups. 4. In comparison between composite resins, Silux Plus showed significantly more leakage than other groups at the enamel margin and no statistically significant differences were found in microleakage at the cementum margin. 5. According to the backscattered scanning electron microscope, microleakage occurred via gaps at the dentin adhesives/dentin interface.

  • PDF

Gait Stability in K-pop Professional Dancers

  • Jang, Young Kwan;Hong, Su Yeon;Jang, Inyoung
    • 한국운동역학회지
    • /
    • 제26권4호
    • /
    • pp.377-382
    • /
    • 2016
  • Objective: The purpose of this study was to provide data on gait characteristics of K-pop professional dancers. Method: Participants were divided into four groups: male dancers (n=10, age: $28.2{\pm}3.4years$, height: $175{\pm}6cm$, weight: $68.9{\pm}5.6kg$), female dancers (n=10, age: $26.7{\pm}3.1years$, height: $162{\pm}4cm$, weight: $52.1{\pm}3.7kg$), non-dancer males (n=10, age: $25.2{\pm}2.6years$, height: $171{\pm}6cm$, weight: $66.4{\pm}5.3kg$), or non-dancer females (n=10, age: $26.2{\pm}3.0years$, height: $161{\pm}5cm$, weight: $56.4{\pm}6.7kg$). Twelve infrared cameras (Qualisys, Oqus 500, Sweden, 150 Hz.) were used to capture three-dimensional motion data. Gait motion data of professional dancers and ordinary persons were obtained. Results: K-pop dancers' dynamic stability during the female toe off event and the male heel contact event was better compared with that of ordinary persons in the front-rear direction. In addition, the results showed a significant difference in the margin of stability (MoS). However, the medial-lateral direction of both female and male dancers during heel contact and the toe off event was more stable compared with ordinary person, who exhibited an increased MoS than did the dancers. Conclusion: This study aimed to investigate the gait characteristics of K-pop professional dancers in comparison with ordinary persons using gait parameters and MoS. The stability of K-pop professional dancers' dynamic gait in the front-rear direction was better than that in the medial-lateral direction. Therefore, further studies in which the dance movements of K-pop dancers are sub-divided and analyzed will be necessary to reduce related injury.

Cerebral Hemodynamics in Premature Infants

  • Rhee, Christopher J.;Rios, Danielle R.;Kaiser, Jeffrey R.;Brady, Ken
    • Neonatal Medicine
    • /
    • 제25권1호
    • /
    • pp.1-6
    • /
    • 2018
  • Extremely low birth weight infants remain at increased risk of intraventricular hemorrhage from the fragile vascular bed of the germinal matrix; the roles of hypotension (ischemia) and reperfusion (hyperemia) in the development of intraventricular hemorrhage are still debated. Cerebrovascular pressure autoregulation protects the brain by maintaining constant cerebral blood flow despite changes in blood pressure. The ontogeny of cerebrovascular pressure autoregulation has not been well established and uncertainty remains about the optimal arterial blood pressure required to support brain perfusion. Another important aspect of premature cerebral hemodynamics is the critical closing pressure--the arterial blood pressure at which cerebral blood flow ceases. Interestingly, in premature infants, the critical closing pressure approximates the mean arterial blood pressure. Often in this unique population, cerebral blood flow occurs only during systole when the diastolic arterial blood pressure is equal to the critical closing pressure. Moreover, the diastolic closing margin, a metric of cerebral perfusion that normalizes diastolic arterial blood pressure to the critical closing pressure, may be a better measure than arterial blood pressure for defining cerebral perfusion in premature infants. Elevated diastolic closing margin has been associated with intraventricular hemorrhage. This review summarizes the current state of understanding of cerebral hemodynamics in premature infants.

Collapse assessment and seismic performance factors in tall tube-in-tube diagrid buildings

  • Khatami, Alireza;Heshmati, Mahdi;Aghakouchak, Ali Akbar
    • Earthquakes and Structures
    • /
    • 제19권3호
    • /
    • pp.197-214
    • /
    • 2020
  • Diagrid structures have been introduced as a fairly modern lateral load-resisting system in the design of high-rise buildings. In this paper, a novel diagrid system called tube-in-tube diagrid building is introduced and assessed through pushover and incremental dynamic analyses. The main objectives of this paper are to find the optimum angle of interior and exterior diagrid tube and evaluate the efficiency of diagrid core on the probability of collapse comparing to the conventional diagrid system. Finally, the seismic performance factors of the proposed system are validated according to the FEMA P695 methodology. To achieve these, 36-story diagrid buildings with various external and internal diagonal angles are designed and then 3-D nonlinear models of these structures developed in PERFORM-3D. The results show that weight of steel material highly depends on diagonal angle of exterior tube. Adding diagrid core generally increases the over-strength factor and collapse margin ratio of tall diagrid buildings confirming high seismic safety margin for tube-in-tube diagrid buildings under severe excitations. Collapse probabilities of both structural systems under MCE records are less than 10%. Finally, response modification factor of 3.0 and over-strength factor of 2.0 and 2.5 are proposed for design of typical diagrid and tube-in-tube diagrid buildings, respectively.

보병용 배낭의 휴대 및 이동 성능에 관한 연구 (A study of the Infantry Backpack System for Portability and Mobility Performance)

  • 정성학
    • 한국컴퓨터정보학회논문지
    • /
    • 제19권3호
    • /
    • pp.155-161
    • /
    • 2014
  • 본 연구의 목적은 보병용 휴대 배낭 설계를 위하여 인체공학적인 물자취급 중량을 검토하여 휴대 및 이동성능에 기초한 한계하중을 분석하는데있다. 제품설계시 인체공학적 설계가이드라인과 운용현황을 조사분석하여 효율적인 운용성능을 위한 기초자료로 제공하고자 한다. 본 연구에서는 인력물자취급시 역사적 관점에서 생리학적 연구방법, 생체역학적 연구방법, 인체심리학적 연구방법들을 검토하여 보병용 휴대배낭의 휴대성 및 이동성을 분석하였다. 휴대성과 이동성 간의 관계를 분석한 결과, 단거리의 짧은 기동거리에서는 생체역학적 기준치를, 1-2시간의 중간인 이동에서는 인체심리학적 기준치를, 4시간 혹은 그 이상의 장거리에서는 생리학적 기준치를 적용하여 각각의 가이드라인들을 상호 절충하는 것이 필요한 것으로 판단된다. 본 연구에서는 보병의 물자취급시 4가지 연구방법을 제안하였다. 이러한 기존의 설계 가이드라인을 분석한 결과, 병사의 인체사이즈 측면에서는 5%tile의 경우 -091kg으로 여유중량이 부족하지만, 95%tile에서는 34.17kg까지 여유중량이 발생하는 것으로 판단된다. 이러한 연구결과는 물자취급시 편하고, 효율적인 운용성능을 창출하기 위해서 휴대중량과 이동거리에 따라 여유중량을 관리해야 할 것으로 판단된다.