• Title/Summary/Keyword: Weibull deterioration

Search Result 30, Processing Time 0.02 seconds

Effect of Immersion in Water and Thermal Cycling on the Mechanical Properties of Light-cured Composite Resins (광중합형 수복용 복합레진의 기계적 성질에 미치는 수중침적과 Thermal Cycling의 영향)

  • Bae, Tae-Sung;Kim, Tae-Jo;Kim, Hyo-Sung
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.3
    • /
    • pp.327-336
    • /
    • 1996
  • This study was performed to investigate the effec% of immersion in water and thermal cycling on the mechanical peoperties of light cured restorative composite resins. Five commerically available light-cured composite resins(Photo Clearfil A : CA, Lite-Fil A . LF, Clearril Photo Posterior CP, Prisms AP.H.. PA, 2100 : ZH) were unto The specimens of 12 m in diameter and 0.7 m in thickness were made, and an immersion in $37^{\circ}C$ water for 7 days and a thermal cycling of 1000 cycles at 15 second dwell time each in $5^{\circ}C$ and $55^{\circ}C$ baths were performed. Biaxial flexure test was conducted using the ball-on-three-ball method at the crosshead speed of 0.5mm/min. In order to investigate the deterioration of composite resins during the thermal cycling test, Weibull analysis for the biaxial flexure strengths was done. Fracture surfaces and the surfaces before and after the thermal cycling test were examined by SEM. The highest Weibull modulus value of 10.09 after thermal cycling tests which means the lowest strength variation, was observed in the CP group, and the lowest value of 4.47 was obsered in the LF Group. Biaxial flexure strengths and Knoop hardness numbers significantly decreased due to the thermal cycling ($\textit{p}$< 0.01), however, they recovered when specimens were drie4 The highest biaxial flexure strength of 125.65MPa was observed in the ZH group after the thermal cycling test, and the lowest value of 64.86MPa was observed in the CA group. Biaxial flexure strengths of ZH and CP groups were higher than those of PA, CF, and CA groups after thermal cycling test($\textit{p}$< 0.05). Knoop hardness numbers of CP group after the thermal cycling test was the highest(95.47 $\pm$ 7.35kg/$mm^2$) among the samples, while that of CA group was the lowest(30.73 $\pm$ 2.58kg/$mm^2$). Knoop hardness numbers showed the significant differences between the CP group and others after the thermal cycling test(($\textit{p}$< 0.05). Fracture surfaces showed that the composite resin failure developed along the matrix resin and the filler/resin interface region, and the cracks propagated in the conical shape from the maximum tensile stress zone.

  • PDF

A Study of the Failure Distribution and the Failure Difference by the Stress on the K-1 Tracked Vehicle (K-1전차의 고장분포와 부하에 따른 고장률 차이에 대한 연구)

  • Lee, Sang-Jin;Choi, Seok-Yoon
    • Journal of the military operations research society of Korea
    • /
    • v.35 no.2
    • /
    • pp.33-49
    • /
    • 2009
  • The objective of this study is as follows. First, the hazard function on the failure probability density function of the K-1 tracked vehicles can be occurred in the form of the bathtub curve. Second, the failure mode may be different under two different operational situations. The research result shows that the bathtub curve can be fitted in the Weibull distribution, that assumes different shapes according to the specific stage of the system's life cycle. The K-1 tracked vehicle has a relatively high hazard(failure) rate at the time of its first service. The failure rate starts decreasing for a time immediately after it goes into service. After the break-in period, the surviving components have a fairly constant hazard rate. As the K-1 system ages, deterioration of its various parts takes place and the hazard rate starts Increasing. Second, the result shows the failure rate in the harsh operational environment is higher than that in the mild operational environment. In conclusion, the bathtub curve can be logically appropriate in establishing the depot overhaul cycle. Moreover, it is necessary for determining the right time of the depot overhaul to consider not only the age of defense equipment but also the different operational environment.

Modeling of the Failure Rates and Estimation of the Economical Replacement Time of Water Mains Based on an Individual Pipe Identification Method (개별관로 정의 방법을 이용한 상수관로 파손율 모형화 및 경제적 교체시기의 산정)

  • Park, Su-Wan;Lee, Hyeong-Seok;Bae, Cheol-Ho;Kim, Kyu-Lee
    • Journal of Korea Water Resources Association
    • /
    • v.42 no.7
    • /
    • pp.525-535
    • /
    • 2009
  • In this paper a heuristic method for identifying individual pipes in water pipe networks to determine specific sections of the pipes that need to be replaced due to deterioration. An appropriate minimum pipe length is determined by selecting the pipe length that has the greatest variance of the average cumulative break number slopes among the various pipe lengths used. As a result, the minimum pipe length for the case study water network is determined as 4 m and a total of 39 individual pipe IDs are obtained. The economically optimal replacement times of the individual pipe IDs are estimated by using the threshold break rate of an individual pipe ID and the pipe break trends models for which the General Pipe Break Prediction Model(Park and Loganathan, 2002) that can incorporate the linear, exponential, and in-between of the linear and exponetial failure trends and the ROCOFs based on the modified time scale(Park et al., 2007) are used. The maximum log-likelihoods of the log-linear ROCOF and Weibull ROCOF estimated for the break data of a pipe are compared and the ROCOF that has a greater likelihood is selected for the pipe of interest. The effects of the social costs of a pipe break on the optimal replacement time are also discussed.

Survey for the Management of Reservoirs under Control of Local Authorities of Reservoir of City.Gun in Korea (시.군 관리 저수지 실태 조사 및 정비방안에 관한 연구)

  • Choi, Won;Kim, Han-Jung;Yoon, Seong-Su;Kim, Jong-Ok;Jung, Nam-Su;Lee, Hyung-Jin;Han, Yi-Cheol;Lee, Jeong-Jae
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.50 no.3
    • /
    • pp.31-41
    • /
    • 2008
  • There are many agricultural facilities (46.7%) that have been over 30 years in the Republic of Korea (the ratio of reservoirs built before 1945 is 53%, from 1946 to 1971 is 35%). In the case of reservoirs which do most important functions among these facilities, only 3,000 reservoirs are managed by Korea Rural Community & Agriculture Corporation (KRC) and the other 15,000 reservoirs are managed by local authorities (City and Gun). But, 15,000 reservoirs included in City. Gun have been built in more wide area than KRC and the reservoir management system has not been operated well because of shortage of budget and manpower of the local authorities. Particularly, the abnormal weather happened during every summer season recently has ruined a lot of rural community facilities. So flood control function have been more important than irrigation function in agricultural reservoir system and it may be required to introduce new safe, management and maintenance techniques in City Gun reservoirs. So we investigated landscapes and deteriorations of agricultural reservoirs managed by local small governments for revealing not only present usage but also future value. Survey shows that there are no structural managements except typical hydrological reportings and the deterioration of small darn is very serious. There are needs for more systematic management system and equipment methods. Therefore, this study may suggest that reservoir (that takes charge of the greatest deal of weight in all agricultural facilities) must be considered as new concept of the usage and the unification. On the other hand, reservoir must be also developed as amenity resources, natural circumstances and district values.

The Prediction of Remaining Life of Concrete Bridge Decks Using The Reliability Analysis (신뢰도 분석을 통한 고속도로 교량의 바닥판 잔존 수명 예측)

  • Park, Jung-Hee;Lee, Sang-Soon;Kim, Ji-Won;Park, Cheol-Woo;Lee, Dong-Hyun
    • International Journal of Highway Engineering
    • /
    • v.13 no.4
    • /
    • pp.71-79
    • /
    • 2011
  • Korean national highway has been increased 2 times more for the past ten years because of many highway geometric improvements and new routes since 2000. According to the reasons, maintenance cost has been increased continuously. Deterioration of concrete bridge decks caused by asphalt pavement deformation occupies a high proportion of overall bridge management budget. The number of current highway bridges has reached over 7,800 in 2011, and It is difficult to determine to some future budget. This study predicted the remaining life of concrete bridge decks using the reliability analysis based on Weibull distribution. and The expected future maintenance cost was estimated.

A study on Lifetime Evaluation of High-power Cables Based on Temperature Changes (온도변화에 따르는 고전력 케이블의 수명 변화 연구)

  • Um, Kee-Hong;Lee, Kwan-Woo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.2
    • /
    • pp.273-278
    • /
    • 2015
  • In order to meet increasing power demands, electrical capacity of equipment for power transfers should become larger accordingly. The equipment used for producing and delivering high-voltage power is also required to operate with a high degree of reliability. The stable operation of power equipment is a necessity, not an option. The current through the power cable, the only device to deliver high power, generates a Joule heat, which causes a deteriorating process on the cable system. The XLPE cable is manufactured in such a manner that it can operate for 30 years at $90^{\circ}$, but there is no guarantee that each cable will reach its projected lifetime of 30 years. In this paper, we have measured the temperatures of nine power cables in operation, based on the theory of cable longevity. In order to study the relationship between temperature and longevity, we have devised a new set of equipment and installed it at Korea Western Power Co., Ltd. located in Taean.

A Study on Cable Lifetime Evaluation Based on Characteristic Analysis of Insulation Resistance by Acceleration Factor of the Arrhenius Equation (아레니우스 방정식의 가속인자를 만족하는 절연저항특성 분석에 의한 케이블 수명평가 연구)

  • Um, Kee-Hong;Lee, Kwan-Woo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.5
    • /
    • pp.231-236
    • /
    • 2014
  • With the development of industry these days, the demand for electric power increases and the larger capacity for power transfer is required. The scales of facilities should become larger; and the relative systems are required to operate with a higher degree of reliability. Therefore, stabilization of electric power systems is an important issue. The high degree of reliability required in the process of production and supply of electric power is an essential part of industrial society. Accident such as blackouts causes a hugh amount of economic losses to the high-tech industrial society dependent upon electric power. In this paper, in order to determine a stable operation of high-voltage power cable, used as a unique means of delivering electric power generated at a power station, we figure out the time rate of change of insulation resistance following a decay accelerating factor Arrhenius equation. With the data from the insulation resistance, we can determine the lifetime of power cable in operation.

Nano-mechanical Properties of Nanocrystal of HfO2 Thin Films for Various Oxygen Gas Flows and Annealing Temperatures (RF Sputtering의 증착 조건에 따른 HfO2 박막의 Nanocrystal에 의한 Nano-Mechanics 특성 연구)

  • Kim, Joo-Young;Kim, Soo-In;Lee, Kyu-Young;Kwon, Ku-Eun;Kim, Min-Suk;Eum, Seoung-Hyun;Jung, Hyun-Jean;Jo, Yong-Seok;Park, Seung-Ho;Lee, Chang-Woo
    • Journal of the Korean Vacuum Society
    • /
    • v.21 no.5
    • /
    • pp.273-278
    • /
    • 2012
  • Over the last decade, the hafnium-based gate dielectric materials have been studied for many application fields. Because these materials had excellent behaviors for suppressing the quantum-mechanical tunneling through the thinner dielectric layer with higher dielectric constant (high-K) than $SiO_2$ gate oxides. Although high-K materials compensated the deterioration of electrical properties for decreasing the thickness of dielectric layer in MOSFET structure, their nano-mechanical properties of $HfO_2$ thin film features were hardly known. Thus, we examined nano-mechanical properties of the Hafnium oxide ($HfO_2$) thin film in order to optimize the gate dielectric layer. The $HfO_2$ thin films were deposited by rf magnetron sputter using hafnium (99.99%) target according to various oxygen gas flows. After deposition, the $HfO_2$ thin films were annealed after annealing at $400^{\circ}C$, $600^{\circ}C$ and $800^{\circ}C$ for 20 min in nitrogen ambient. From the results, the current density of $HfO_2$ thin film for 8 sccm oxygen gas flow became better performance with increasing annealing temperature. The nano-indenter and Weibull distribution were measured by a quantitative calculation of the thin film stress. The $HfO_2$ thin film after annealing at $400^{\circ}C$ had tensile stress. However, the $HfO_2$ thin film with increasing the annealing temperature up to $800^{\circ}C$ had changed compressive stress. This could be due to the nanocrystal of the $HfO_2$ thin film. In particular, the $HfO_2$ thin film after annealing at $400^{\circ}C$ had lower tensile stress, such as 5.35 GPa for the oxygen gas flow of 4 sccm and 5.54 GPa for the oxygen gas flow of 8 sccm. While the $HfO_2$ thin film after annealing at $800^{\circ}C$ had increased the stress value, such as 9.09 GPa for the oxygen gas flow of 4 sccm and 8.17 GPa for the oxygen gas flow of 8 sccm. From these results, the temperature dependence of stress state of $HfO_2$ thin films were understood.

A Linear Change of Leakage Current and Insulation Resistance of 22 kV Cables (22 kV 케이블의 누설전류 및 절연저항의 선형적 변화)

  • Um, Kee-Hong;Lee, Kwan-Woo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.3
    • /
    • pp.169-173
    • /
    • 2015
  • This study is to predict the life exponent by measuring, over 7 years, the insulation resistance of high-voltage cables in 22 kV operation for 13 years. We found out the lifetime index in order to determine the time-dependent trend of deteriorating performance of power cables. The insulation resistances decreased according to elapsed time. We found that: the initial measurements of the cable systems were in agreement with the deterioration properties of the Arrhenius Law. By analyzing the life curve of the cable system, we also verified that the value of the life exponent (n) in the v-t characteristics defined by Weibull distribution has values from 10 to 11. When designing the cable system, the initial value of life exponent was chosen as 9 without any grounding. We have verified that the theoretical grounding based on the design safety of n=9 was actually the best one available. In the short term, we apply our research result to the diagnosis and evaluation of the power cables. In the long run, however, we plan to reduce the cost of the installation and management of cable systems in operation at power stations.

Life assessment of monitoring piezoelectric sensor under high temperature at high-level nuclear waste repository (고준위방사성폐기물 처분장 고온 환경 조건에 대한 모니터링용 피에조 센서의 수명 평가)

  • Changhee Park;Hyun-Joong Hwang;Chang-Ho Hong;Jin-Seop Kim;Gye-Chun Cho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.25 no.6
    • /
    • pp.509-523
    • /
    • 2023
  • The high-level nuclear waste (HLW) repository is exposed to complex environmental conditions consisting of high temperature, high humidity, and radiation, resulting in structural deterioration. Therefore, structural health monitoring is essential, and piezo sensors are used to detect cracks and estimate strength. However, since the monitoring sensors installed in the disposal tunnel and disposal container cannot be replaced or removed, the quantitative life of the monitoring sensor and its suitability must be assessed. In this study, the life of a piezo sensor for monitoring was assessed using an accelerated life test (ALT). The failure mode and mechanism of the piezo sensor under high temperature conditions were determined, and temperature stress's influence on the piezo sensor's life was analyzed. ALT was conducted on temperature stress and the relationship between temperature stress and piezo sensor life was suggested. The life of the piezo sensor was assessed using the Weibull probability distribution and the Arrhenius acceleration model. The suggested relationship can be used in multiple stress ALT designs for more precise life assessment.