• Title/Summary/Keyword: Weak grid

Search Result 75, Processing Time 0.028 seconds

Analysis and Compensation of PCC Voltage Variations caused by Wind Turbine Power Fluctuations

  • Im, Ji-Hoon;Song, Seung-Ho;Kang, San
    • Journal of Power Electronics
    • /
    • v.13 no.5
    • /
    • pp.854-860
    • /
    • 2013
  • The voltage variation problem at the point of common coupling (PCC) in a grid-connected wind turbine is investigated. The voltage variation problem is one of the most frequent power quality issues for the grid connection of large amounts of input power in a weak grid. Through the simplified modeling of the wind turbine and power network, the magnitude of PCC voltage variation is calculated by using the equivalent circuit parameters and output power of the wind turbine. The required amount of reactive power that can compensate the voltage variation is also presented analytically by using the vector diagram method. The proposed calculation and compensation method of the PCC voltage variation is verified by computer simulations and experiments.

Analysis of Power Generation Characteristics according to the MPPT Algorithm Period (MPPT 알고리즘의 주기에 따른 발전 영향 분석)

  • Min, Joonki;Choi, Wonseok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.67 no.4
    • /
    • pp.233-237
    • /
    • 2018
  • In this paper, we compared power generation characteristics of two MPPT algorithms, P & O and InC, applied to grid-connected solar inverters. The MPPT detects the voltage and current of the solar module string and transfers the power to the DC link. Since the grid is connected by the power conversion circuit, the grid connection control and the MPPT control influence each other. The power generation characteristics were analyzed by Psim simulation according to the MPPT cycle in the weak grid conditions.

A Direction of Convergence and Security of Smart Grid and Information Communication Network (스마트그리드(Smart Grid) 전력망과 정보통신망 융합 보안 방향)

  • Seo, Woo-Seok;Jun, Moon-Seog
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.5 no.5
    • /
    • pp.477-486
    • /
    • 2010
  • This Study suggests security directions to reconstruct separate network of Smart Grid and information communication network as one communications system and implement Smart Grid integrated information communication network. In addition, it suggests prevention directions to prevent future cyber attacks by reorganizing network as the key three-stage network and separating TCP/IP four layers that consist of existing information communication network from Smart Grid. Moreover, it suggests the foundation for the study and the test by providing current problems of Smart Grid, weak points, and three security models. This study is meaningful to suggest development directions and situations as a technology of future-oriented electric industries, integrate attacks and preventions of TCP/IP Layers with Smart Grid, and seek for a new technology of Smart Grid and future tasks for Smart Grid information security.

A Study on Grid Adaptation by Poisson Equation (푸아송 방정식을 이용한 격자 적응에 대한 연구)

  • 맹주성;문영준;김종태
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.1
    • /
    • pp.182-189
    • /
    • 1993
  • To improve the resolution of complex flow field features, grid adaptation scheme of Anderson has been revised, which was based on the Poisson grid generator of Thompson. Anderson's original scheme adapts the grid to solution automatically, but if flow field is more or less complex, then the adaptivity is weak. So the technique of using threshold which is used in unstructured grid system is adopted. The regions of large variation in the solution are marked by marking function which has the property of total variation of the solution, and these regions have same values of weight but other regions are neglected. This updated method captures shocks clearly and sharpy. Four examples are demonstrated, (1) Hypersonic flow past a blunt body, (2) High speed inlet analysis, (3) Supersonic flow of M=1.4 over a 4% biconvex airfoil in a channel, (4) Hypersonic shock-on-shock interaction at M=8.03.

Modified mixing coefficient for the crossflow between sub-channels in a 5 × 5 rod bundle geometry

  • Lee, Jungjin;Lee, Jun Ho;Park, Hyungmin
    • Nuclear Engineering and Technology
    • /
    • v.52 no.11
    • /
    • pp.2479-2490
    • /
    • 2020
  • We performed experiments to measure a single-phase upward flow in a 5 × 5 rod bundle with spacer grids using a particle image velocimetry, focusing on the crossflow. The Reynolds number based on the hydraulic diameter and the bulk velocity is 10,000. The ratio of pitch between rods and rod diameter is 1.4 and spacer grid is installed periodically. The turbulence in the rod bundle results from the combination of a forced mixing and natural mixing. The forced mixing by the spacer grid persists up to 10Dh from the spacer grid, while the natural mixing is attributed to the crossflow between adjacent subchannels. The combined effects contribute to a sinusoidal distribution of the time-averaged stream-wise velocity along the lateral direction, which is relatively weak right behind the spacer grid as well as in the gap. The streamwise and lateral turbulence intensities are stronger right behind the spacer grid and in the gap. Based on these findings, we newly defined a modified mixing coefficient as the ratio of the lateral turbulence intensity to the time-averaged streamwise velocity, which shows a spatial variation. Finally, we compared the developed model with the measured data, which shows a good agreement with each other.

Improvement of Interface Adhesionin Ball Grid Array Packages by Plasma Treatment (플라즈마 처리에 의한 BGA 패키지의 계면 접착력 향상)

  • 김경섭;한완옥;장의구
    • Journal of Welding and Joining
    • /
    • v.18 no.4
    • /
    • pp.64-69
    • /
    • 2000
  • Reliability of PBGA(Plastic Ball Grid Array) package is very weak compared with normal plastic packages. The reliability are the lower resistance to popcorn cracking, which is reduced by moisture absorption in PCB(Printed Circuit Board). This paper adapts plasma treatment process and analyzes their effect. The contents of C and Cl decrease after plasma treatment but O, Ca and N relatively increase. The Plasma treatment to improve the adhesion between EMC(Epoxy Molding Compound) and PCB(solder mask). The degree of improvement was over 100% Max., which is depend on the properties of EMC. Ar+H$_2$as plasma gas show good result. There is a little difference in RF power and treatment time.

  • PDF

A Study on Tuning of Current Controller for Grid-connected Inverter Using Particle Swarm Optimization (PSO를 이용한 계통연계형 인버터 전류제어기의 자동조정에 관한 연구)

  • Ahn Jong-Bo;Kim Won-gon;Hwang Ki-Hyun;Park Jun-H
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.11
    • /
    • pp.671-679
    • /
    • 2004
  • This paper presents the on-line current controller tuning method of grid-connected inverter using PSO(particle swarm optimization) technique for minimizing the harmonic current. Synchronous frame PI current regulator is commonly used in most distributed generation. However, due to the source voltage distortion, specially in weak AC power system, current may contain large harmonic components, which increase THD(total harmonic distortion) and deteriorates power quality. Therefore, some tuning method is necessary to improve response of current controller. This paper used the PSO technique to tune the current regulator and through simulation and experiments, usefulness of the tuning method has been verified. Especially in simulating the tuning process, ASM(average switching model) of inverter is used to shorten execution time.

Application of Vertical Grid-nesting to the Tropical Cyclone Track and Intensity Forecast

  • Kim, Hyeon-Ju;Cheong, Hyeong-Bin;Lee, Chung-Hui
    • Journal of the Korean earth science society
    • /
    • v.40 no.4
    • /
    • pp.382-391
    • /
    • 2019
  • The impact of vertical grid-nesting on the tropical cyclone intensity and track forecast was investigated using the Weather Research and Forecast (WRF) version 3.8 and the initialization method of the Structure Adjustable Balanced Bogus Vortex (SABV). For a better resolution in the central part of the numerical domain, where the tropical cyclone of interest is located, a horizontal and vertical nesting technique was employed. Simulations of the tropical cyclone Sanba (16th in 2012) indicated that the vertical nesting had a weak impact on the cyclone intensity and little impact on the track forecast. Further experiments revealed that the performance of forecast was quite sensitive to the horizontal resolution, which is in agreement with previous studies. The improvement is due to the fact that horizontal resolution can improve forecasts not only on the tropical cyclone-scale but also for large-scale disturbances.

A Study of Waveform Inversion for Improvement of Sub-Salt Migration Image (암염돔 하부 구조의 구조보정 영상 개선을 위한 파형역산 기법 연구)

  • Ha, Wan-Soo;Pyun, Suk-Joon;Son, Woo-Hyun;Shin, Chang-Soo;Ko, Seung-Won;Seo, Young-Tak
    • Geophysics and Geophysical Exploration
    • /
    • v.11 no.3
    • /
    • pp.177-183
    • /
    • 2008
  • The sub-salt imaging technique becomes more crucial to detect the hydro-carbonates in petroleum exploration as the target reservoirs get deeper. However, the weak reflections from the sub-salt structures prevent us from obtaining high fidelity sub-salt image. As an effort to overcome this difficulty, we applied the waveform inversion by implementing multi-grid technique to the sub-salt imaging. Through the comparison between the conventional waveform inversion using fixed grid and the multi-grid technique, we confirmed that the waveform inversion using multi-grid technique has advantages over the conventional fixed grid waveform inversion. We showed that the multi-grid technique can complement he velocity estimation result of the waveform inversion for imaging the sub-salt structures, of which velocity model cannot be obtained correctly by the conventional fixed grid waveform inversion.

Flicker Mitigation in a Wind Farm by Controlling a Permanent Magnet Synchronous Generator (영구자석형 동기발전기를 이용한 풍력단지의 플리커 저감)

  • Hoan, Pham Van;Kim, Dae-Hyun;Ahn, Jin-Hong;Kim, Eel-Hwan;Oh, Seong-Bo;Kim, Ho-Chan;Kim, Se-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.12
    • /
    • pp.1163-1168
    • /
    • 2009
  • The power quality of wind energy becomes more and more important in connecting wind-farms to the grid, especially weak grid. This paper presents the simulation of a wind farm of a permanent magnet synchronous generator (PMSG) and a doubly fed induction generator (DFIG). Flicker mitigation is performed by using PMSG as a static synchronous compensator (STATCOM) to regulate the voltage at the point of common coupling (PCC). A benefit of the measure is that integrating two function of to control the active power flow and to reduce the voltage flicker in a wind farm. Simulation results show that controlling PMSG is an effective and economic measure in reducing the flicker during continuous operation of grid connected wind turbines regardless of short circuit capacity ratio, turbulence intensity and grid impedance angle.