• Title/Summary/Keyword: Wax pattern

Search Result 77, Processing Time 0.024 seconds

A Case of Angiodysplasia in the colon with IDA ; Review of east and west literature (철결핍성 빈혈(IDA)을 동반한 위장관 혈관확장증(Intestinal angiodysplasia) 1례)

  • Jeong Hwan-Su;Lee Jin-Yong;Kim Deok-Gon
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.14 no.1
    • /
    • pp.183-188
    • /
    • 2000
  • Angiodysplasia is uncommon and frequently undiagnosed and presents a taxing surgical problem. It is usually diagnosed for unexplained gastrointestinal bleeding. Angiography gives a little information about wax and wane pattern of bleeding in the lesion. We experienced I case of angiodysplasia in G-I tract(especially colon) diagnosed in the Seoul National University Hospital. This report summarized our experience and review of east and west literature.

  • PDF

A Study on Traditional Costume of the Minorities in Guizhou Province of China (중국(中國) 귀주성(貴州省) 소수민족(少數民族)의 민족복식(民族服飾)에 관(關)한 연구(硏究))

  • Boo, Ae-Jin
    • Journal of Fashion Business
    • /
    • v.7 no.4
    • /
    • pp.142-154
    • /
    • 2003
  • This study was conducted on the costume of the 6 minorities dwelling in Guizhou Province of China. The result of the study is summarized as follows. As Guizhou Province yields much silver, most of the minorities used silver ornaments a lot and dyed their garments by using indigo extracted from plants that grow in the area. The headdress was of style that for both men and women a long cloth is wound around a head in various ways. In some cases, women used cow's horn, pearl and silver ornaments. Most wore a short upper garment such as blouses with overlapping necks or blouses with diagonal on the front, and as a lower garment men and women wore trousers and skirts, respectively. As a way of ornament, embroidering, wax printing and weaving were commonly used, but pattern and color used in the ornament varied depending on the individual minorities.

Fabrication of R.P.D framework by using Acetal Resin (Acetal resin을 이용한 R.P.D framework의 제작)

  • Kim, Chung-Sook;Park, Myoung-Ho
    • Journal of Technologic Dentistry
    • /
    • v.23 no.1
    • /
    • pp.107-114
    • /
    • 2001
  • R.P.D fabrication can be made if the skills already is properly used in the manufacturing press. You may feel extremely comfortable to wear it. The material used has high elasticity that it can endure the hole process of Acetal Wax pattern casting without any deformation moreover its adaptability is not bad. Because of the poor financial condition of patterns and health insurance, Acetal R.P.D Framework can be one of the best alternatives used for setting clasp partial denture cheaply. R.P.D Framework is aesthetically excellent. The color caused by saliva is so similar to that of the rest of teeth that even dentists as well as patients can not recognize clasp arm. Clasp also helps to secure prosthesis ideally without damaging teeth due to its deep position downward. Since dentists and patients have a good reaction to clasp so far, we are encouraged to apply it to other technical fields.

  • PDF

A Study on Shear Bond Strength of Heat Press Ceramic to Non Precious Porcelain Metal (도재용착용 비귀금속과 열가압성형도재의 전단결합강도 연구)

  • Kim, Seong-Soo;Kim, Wook-Tae;Lee, Myung-Kon
    • Journal of Technologic Dentistry
    • /
    • v.33 no.1
    • /
    • pp.37-45
    • /
    • 2011
  • Purpose: Heat pressed ceramics, used for all ceramic restorations, have the additional advantage of being technically less change through using of the lost-wax technique. Conceptually, combining the ceramic with the clinically proven reinforcing ability of a metal framework would be advantageous; however, cause of mismatching of fusion between ceramics and metal frameworks which from differences of casting temperature and coefficient of thermal expansion, pressed ceramics could not be used with a metal framework. The purpose of this study was to compare shear bond strength of press-to metal ceramic to porcelain fused non precious metal and feldspatic porcelain fused non precious metal. Methods: The 30 metal specimens were casted in a porcelain fused non precious metal nickel-chromium alloy. They were divided into 3 groups by surface treatment and applied ceramic: $125{\mu}m$ aluminium oxide sandblasting and veneered feldspatic porcelain (group FP), $125{\mu}m$ aluminium oxide sandblasting and had press-to-metal ceramic applied (group PC), porcelain bonder (gold bonder) fused on surface of metal specimens and had press-to-metal ceramic applied (group PCG). In each group 10 metal specimens were used. The press-to-metal ceramic applied 20 specimens had ash-free wax pattern applied, the metal-wax complexes invested, and were pressed with heat press ceramic. All specimens were subjected to shear bond strength test at a crosshead speed of 1.0 mm/min. Results: The results of measured in Mean SD and data were analyzed by one-way AVOVA (p= .05) and Tukey HSD test (p= .05).: group FP $16.090{\pm}1.841$ MPa, group PC $12.620{\pm}1.8256$ MPa, group PCG $10.920{\pm}0.9283$, significant differences between all groups (p < .05). Significant differences were found in each between group FP and group PC, group FP and group PCG (p < .05). Conclusion: The shear bond strength of press-to-metal ceramic to porcelain fused non precious metal was described higher in unused gold bonder group than used gold bonder groups.

Fixed prosthodontic rehabilitation of maxillary posterior teeth using functionally generated path technique and intraoral digital scan: Case report (Functionally generated path technique 및 구내 디지털 스캔을 이용한 상악 구치부의 고정성 보철 수복 증례)

  • Kim, Sung-Ho;Lee, Jonghyuk;Choi, Yu-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.3
    • /
    • pp.228-238
    • /
    • 2020
  • In order to deliver fixed partial denture to a patient successfully, dentist must take into many considerations beforehand. Patient's occlusal pattern should be fully understood before delivering any type of prosthesis, whether it's canine guidance or group function occlusion. In order to do so, movement of mandible should be recorded precisely. Introduced by Meyers in 1933, functionally generated path technique (FGP) has been successfully used to record mandibular movement with various materials, such as wax, and utilize it in fabricating precise prosthesis. In the following cases, patients showed secondary caries or endodontic-periodontic lesion on maxillary molars. Root canal treatment and subgingival curettage were done for each patient. Since the long term prognosis of each tooth was questionable, lateral force should be minimized. In order to do so, FGP technique was used to record mandibular movements precisely. Instead of using conventional plaster impression, intra-oral scanning of wax tracing was done to fabricate prosthesis efficiently. After delivery of fixed partial denture, favorable outcome was obtained.

The Effect of Cooling method on the Surface Reaction Zone of CP Titanium Casting Body (티타늄 주조체 냉각방법이 표면반응층에 미치는 영향)

  • Moom, Soo;Choi, Seog-Soon;Moon, Il
    • Journal of Technologic Dentistry
    • /
    • v.23 no.2
    • /
    • pp.203-210
    • /
    • 2002
  • This test is to conduct applied research the reaction area of the Ti-cast metal body which is made use of Dental Phosphate-silica alumina bonded investment material selling at a market, and the cooling method is how to effect on the acicular. The experimentation is as followings, 1. Experimental specimens After invest with Dental Phosphate-silica alumina bonded investment material, the $10{\times}10{\times}1.0mm^3$ wax pattern was casted by Dental high vacuum argon centrifugal casting machine. 2. Test We can analyze SEM/EDS, XRD utilize the fractography(an optical microscope). 3. Conclusion The pure cast metal body constituted of reaction products layer, stability layer and contamination layer. This pure cast have no connection with the cooling condition. The pure Titanium shows difference in a component distribution according to the cooling condition. Through this experimentation we can establish that acicular in the pure Ti-cast metal is consist of Hexagonal structure a=2.9505$\AA$, c=4.6826$\AA$.

  • PDF

Composition of nickel-chromium alloy on the centrifugal casting and the influence of quantitative of oxides on the casting temperature (원심 주조한 니켈-크롬 합금의 성량 변화 및 주조 온도에 따른 산화물 측정)

  • Kim, Won-Soo
    • Journal of Technologic Dentistry
    • /
    • v.34 no.4
    • /
    • pp.361-368
    • /
    • 2012
  • Purpose: The aim of this study was to analysis the composition on the centrifugal casting and the oxide on the casting temperature. Methods: The nickel based alloy were used in this study. Wax pattern specimens (10*10*2) were invested with phosphate-bonded investment in metal rings, the liquid/powder ratio and overall burn-out schedules for these investments were followed in accordance with the manufacturer's instructions. After casting, the alloy specimens were evaluated as regards composition(EPMA). The casting temperatures were as follows: $1400^{\circ}C$ and $1700^{\circ}C$. The quantitative analysis of oxides were scanning electron microscope(SEM), energy dispersive spectroscopy(EDS) and line scanning. Results: Nearer the injection lines showed that there is a large amount of nickel. Quantitative of oxides of Ni-Cr alloy cast from $1400^{\circ}C$ is lager than Ni-Cr alloy cast from $1700^{\circ}C$. Conclusion: Casting when using a centrifugal casting machine centrifugal force affects the composition of the alloy. The higher the temperature, the amount of oxide that is generated many.

A Study on the Castability of Investing Method and Casting Direction of Chrome-Cobalt Alloy Widely Used in Production of Patial Denture Framework (국부의치 제작에 사용되는 Chrome Cobalt Alloy 주조 시 매몰방법과 주조방향이 주조성에 미치는 영향에 관한 연구)

  • Chung, Kyung-Pung;Choi, Un-Jae
    • Journal of Technologic Dentistry
    • /
    • v.21 no.1
    • /
    • pp.77-85
    • /
    • 1999
  • When producing partial denture using a Chrome-cobalt alloy being used universally, 45 pattern of them to compare casting characters according to 5 burying methods(special ring method, plastic ring method, general metal ring method) and 5 casting directions(straight, upper, lower, left and right directions) were compared and evaluated. The results were as follows : 1. The comparison of casting characters in accordance with burying type shows that the special ring method to install blind air vent using utility wax was the highest rate of 76.9%, followed by 69.1% of the plastic ring to cast without ring and 61.1% of the metal ring method being used universally respectively. Namely the special ring method was best. The significant level was P<0.05 statistically. 2. The comparison of casting character in accordance with casting directions shows that the straight casting was the highest of 77.9%, and followed by right casting of 74.2%, left casting of 66.7%, upper casting of 63.5%, and lower casting of 62.9% respectively, Namely the straight casting was best.

  • PDF

A METHOD OF CAST CROWN RESTORATION FOR EXISTING PARTIAL DENTURE CLASP AND A CASE REPORT OF IT (기존 Clasp에 적합한 주조 금관 형성법과 임상응용 1 예)

  • Lee, Ho-Yong;Chung, Moon-Kyu;Kim, Chong-Youl
    • The Journal of the Korean dental association
    • /
    • v.16 no.2 s.105
    • /
    • pp.123-128
    • /
    • 1978
  • Sometimes in clinic, we have found that cast crown construction is necessary to fit the existing partial denture clasp, when the abutment is involved with caries, a failing restoration, periodontal disease, or fracture. This is important not only to protect the abutment tooth from missing, but to restore retention, bracing and support for partial denture. For constructing the cast crown, several methods have been reported by many of previous authors. The number of techniques reported during the past are ideal but have uncertain results However, with more improved and practical technic developed by me, the problem becomes more successful. One method in which does not need the laboratory technecian is the wax pattern has been made in chairside waxing by doctor himself. The other in which requires the laboratory technician is to use special impression method and articulator for laboratory waxing. In one case of the reported here, we have successful results in restoring the abutment with cast crown for original denture clasp.

  • PDF

FRACTURE STRENGTH OF ZIRCONIA MONOLITHIC CROWNS (지르코니아 단일구조 전부도재관의 파절강도)

  • Jeong Hee-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.2
    • /
    • pp.157-164
    • /
    • 2006
  • Purpose: The purpose of this study was to compare the fracture strength of the zirconia monolithic all-ceramic crowns according to the thickness(0.5 mm, 0.8 mm, 1.1 mm) and IPS Empress II ceramic crown of 1.5 mm thickness. Material and method: Eight crowns for each of 3 zirconia crown groups were fabricated using CAD/CAM system(Kavo, Germany) and eight Empress II crowns were made from silicone mold and wax pattern. Each crown group was finished in accordance with the specific manufacturer s instruction. All crowns were luted to the metal dies using resin cement and mounted on the testing jig in a universal testing machine. The load was directed at the center of crown with perpendicular to the long axis of each specimen until catastrophic failure occurred. Analysis of variance and Tukey multiple comparison test(p<.05) were applied to the data. Results and Conclusion: 1. The fracture strength of the zirconia monolithic all-ceramic crown was higher thickness increased(p<.05). 2 The fracture strength of 1.1 mm thickness zirconia monolithic all-ceramic crown was higher than the fracture strength of 1.5 mm thickness IPS Empress II crown(p<.05). 3. The fracture strength of 0.5 mm thickness zirconia monolithic all-ceramic crown exceeded maximum occlusal forces.