• Title/Summary/Keyword: Wavelength monitoring

Search Result 210, Processing Time 0.029 seconds

Feasibility Study on Packaged FBG Sensors for Debonding Monitoring of Composite Wind Turbine Blade (풍력발전기 복합재 블레이드의 접착 분리 모니터링을 위한 패키징 광섬유 브래그 격자 센서 탐촉자의 사용성 검토)

  • Kwon, Il-Bum;Choi, Ki-Sun;Kim, Geun-Jin;Kim, Dong-Jin;Huh, Yong-Hak;Yoon, Dong-Jin
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.4
    • /
    • pp.382-390
    • /
    • 2011
  • Smart sensors embedable in composite wind turbine blades have been required to be researched for monitoring the health status of large wind turbine blades during real-time operation. In this research, the feasibility of packaged FBG sensor probes was studied through the experiments of composite blade trailing edge specimens in order to detect cracking and debonding damages. The instants of cracking and debonding generated in the shear web were confirmed by rapid changes of the wavelength shifts from the bare FBG sensor probes. Packaged FBG sensor probes were proposed to remove the fragile property of bare FBG sensor probes attached on composite wind blade specimens. Strain and temperature sensitivity of fabricated probes installed on the skin of blade specimen were almost equal to those of a bare FBG sensor. Strain sensitivity was measured to be ${\mu}{\varepsilon}$/pm in a strain range from to 0 to 600 ${\mu}{\varepsilon}$, and the calculated temperature sensitivity was to be 48 pm/$^{\circ}C$ in the heating test up to 80 degree.

In-situ Monitoring of GaN Epilayers by Spectral Reflectance (분광 반사법을 이용한 GaN 박막의 실시간 관찰)

  • Na, Hyun-Seok
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.5
    • /
    • pp.361-366
    • /
    • 2011
  • An in-situ, real-time monitoring of GaN epilayers grown by low pressure metalorganic chemical vapor deposition system modified for spectral reflectance was performed. Reflectance spectrums from 190~861 nm were observed using p-polarized light with incident angle of $75^{\circ}$. All reflectance spectrums showed interference oscillation caused by multiple reflection within GaN epilayers, and the spectrum from GaN with low crystalline quality showed weak reflectance intensity and much low amplitude of the oscillation because many defects in GaN resulted in light scattering and absorption. Signal variation of reflected light which was selected around strong constructive wavelength range was also observed during $NH_3$ supplying and $NH_3$ cut-off. There was no significant change in signal intensity when $NH_3$ cut-off for 10 sec, but it showed higher intensity when $NH_3$ was cut off for over 30 sec and its intensity kept unchanged. This result indicates that GaN surface was N-terminated during $NH_3$ supplying but Ga-terminated during $NH_3$ cut-off because of high nitrogen equilibrium vapor pressure of GaN, and metallic Ga-terminated surface caused slightly higher reflectance intensity.

Establishment of content criteria of marker compounds through the monitoring of Achyranthis Radix collected from Korea and China (한국 및 중국 지역에서 수집된 우슬의 모니터링을 통한 지표성분의 함량기준 설정)

  • Kim, Dae-Hyun;Kim, Sang-Hyuk;Jang, Yu-Seon;Shin, Min-Chul;Chu, Van Men;Lee, Young-Keun;Woo, Mi-Hee;Kang, Jong-Seong
    • Analytical Science and Technology
    • /
    • v.25 no.4
    • /
    • pp.250-256
    • /
    • 2012
  • Two marker compounds of Achyranthis Radix, ecdysterone and inokosterone, were analyzed by HPLC on an ODS column ($250{\times}4.6$ mm, 5 ${\mu}m$) with a mobile phase of 15% acetonitrile containing 0.08% formic acid at a flow rate of 1.0 mL/min and a detection wavelength of UV 254 nm. The method was validated by ICH guideline and applied to the monitoring of marker compounds in 93 samples of Achyranthis Radix collected at various areas in Korea and China. The new content criteria of ecdysterone and inokosterone, established using linear regression method were 0.033% and 0.020%, respectively. When the new content criteria were applied to the quality control test of commercial Achyranthis Radix, 95.4% of total samples including 100% of Korean and 92.6% of Chinese samples were passed the test. Application of new content criteria could protect the Korean products and decrease the distribution of Chinese products with lower quality.

Surface Deformation and Behavior of Magma Activity Using EDM (EDM을 활용한 지표변화율과 마그마 활동 양상 변화 연구)

  • Yun, Sung-Hyo;Lee, Jeong-Hyun
    • The Journal of the Petrological Society of Korea
    • /
    • v.22 no.1
    • /
    • pp.71-81
    • /
    • 2013
  • Measuring the distance between benchmarks placed on a volcano tens to thousands of meters apart can sometimes pinpoint where and when magma is rising toward the surface. Rising magma will sometimes push overlying rocks upward or shove them aside. In either case, one part of the volcano may actually move horizontally relative to another part from as little as a few millimeters to as much as several tens of meters. The challenge in measuring such changes with an electronic distance meter is putting benchmarks in the right places and making frequent measurements between pairs of benchmarks. An electronic distance meter is an instrument that both sends and receives an electromagnetic signal. Depending on the distance between the EDM and reflector, the wavelength of the returned signal will be out of phase with the transmitted signal. The instrument compares the phase of the transmitted and received signals and measures the phase difference electronically. There is a wide range of EDM capabilities in range and precision, but for volcano monitoring purposes, short-range (less than 10 km) to medium-range (less than 50 km) EDM's are typically used. Short-range EDM's transmit and receive the near visible infrared part of the electromagnetic spectrum for measuring distances with an accuracy of about 5 mm.

Observation Test of Field Surface Reflectance Using Vertical Rotating Goniometer on Tarp Surface and Grass (수직 축 회전형 측각기 제작 및 야외 지표면 반사도 관측 시험: 타프와 잔디에서)

  • Moon, Hyun-Dong;Jo, Euni;Kim, Hyunki;Cho, Yuna;Kim, Bo-Kyeong;Ahn, Ho-Yong;Ryu, Jae-Hyun;Cho, Jaeil
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.6_1
    • /
    • pp.1207-1217
    • /
    • 2022
  • Vegetation indices using the reflectance of selected wavelength, associating with the monitoring purpose such as identifying the progress of crop growth, on the vegetation canopy surface is widely used in the digital agriculture technology. However, the surface reflectance anisotropy can distort the true value of vegetation index related to the condition of surface, even though the surface property be unchanged. That causes difficulty to observe accurately crop growth on the monitoring system. In this study, a simple type goniometer was designed to measure the reflectance from the anisotropic surface according to various zeniths and azimuths of sun and viewing sensor in the field. On the tarp like as Lambertian surface, the reflectance of Blue, Green, Red, Near-Infrared band was similar to the tarps' reflectance properties. However, the reflectance was slightly overestimated in the cloudy day. The relative difference values of vegetation indices on grass were overestimated for the forward viewing and underestimated for the backward viewing. In addition, enhanced vegetation index (EVI) showed less sensitive according to the positions of sun and sensor viewing. Field observation with a goniometer will be helpful to understand the anisotropy characteristics on the vegetation surface.

A Study on Transferring Cloud Dataset for Smoke Extraction Based on Deep Learning (딥러닝 기반 연기추출을 위한 구름 데이터셋의 전이학습에 대한 연구)

  • Kim, Jiyong;Kwak, Taehong;Kim, Yongil
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.5_2
    • /
    • pp.695-706
    • /
    • 2022
  • Medium and high-resolution optical satellites have proven their effectiveness in detecting wildfire areas. However, smoke plumes generated by wildfire scatter visible light incidents on the surface, thereby interrupting accurate monitoring of the area where wildfire occurs. Therefore, a technology to extract smoke in advance is required. Deep learning technology is expected to improve the accuracy of smoke extraction, but the lack of training datasets limits the application. However, for clouds, which have a similar property of scattering visible light, a large amount of training datasets has been accumulated. The purpose of this study is to develop a smoke extraction technique using deep learning, and the limits due to the lack of datasets were overcome by using a cloud dataset on transfer learning. To check the effectiveness of transfer learning, a small-scale smoke extraction training set was made, and the smoke extraction performance was compared before and after applying transfer learning using a public cloud dataset. As a result, not only the performance in the visible light wavelength band was enhanced but also in the near infrared (NIR) and short-wave infrared (SWIR). Through the results of this study, it is expected that the lack of datasets, which is a critical limit for using deep learning on smoke extraction, can be solved, and therefore, through the advancement of smoke extraction technology, it will be possible to present an advantage in monitoring wildfires.

Corrections on CH4 Fluxes Measured in a Rice Paddy by Eddy Covariance Method with an Open-path Wavelength Modulation Spectroscopy (개회로 파장 변조 분광법과 에디 공분산 방법으로 논에서 관측된 CH4 플럭스 자료의 보정)

  • Kang, Namgoo;Yun, Juyeol;Talucder, M.S.A.;Moon, Minkyu;Kang, Minseok;Shim, Kyo-Moon;Kim, Joon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.17 no.1
    • /
    • pp.15-24
    • /
    • 2015
  • $CH_4$ is a trace gas and one of the key greenhouse gases, which requires continuous and systematic monitoring. The application of eddy covariance technique for $CH_4$ flux measurement requires a fast-response, laser-based spectroscopy. The eddy covariance measurements have been used to monitor $CO_2$ fluxes and their data processing procedures have been standardized and well documented. However, such processes for $CH_4$ fluxes are still lacking. In this note, we report the first measurement of $CH_4$ flux in a rice paddy by employing the eddy covariance technique with a recently commercialized wavelength modulation spectroscopy. $CH_4$ fluxes were measured for five consecutive days before and after the rice transplanting at the Gimje flux monitoring site in 2012. The commercially available $EddyPro^{TM}$ program was used to process these data, following the KoFlux protocol for data-processing. In this process, we quantified and documented the effects of three key corrections: (1) frequency response correction, (2) air density correction, and (3) spectroscopic correction. The effects of these corrections were different between daytime and nighttime, and their magnitudes were greater with larger $CH_4$ fluxes. Overall, the magnitude of $CH_4$ flux increased on average by 20-25% after the corrections. The National Center for AgroMeteorology (www.ncam.kr) will soon release an updated KoFlux program to public users, which includes the spectroscopic correction and the gap-filling of $CH_4$ flux.

Development of Analytical Methods for Micro Levels of Naphthalene and TNT in Groundwater by HPLC-FLD and MSD (HPLC-FLD와 MSD를 이용한 지하수 중 나프탈렌 및 TNT의 미량 분석법 개발)

  • Park, Jong-Sung;Oh, Je-Ill;Jeong, Sang-Jo;Choi, Yoon-Dae;Her, Nam-Guk
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.6
    • /
    • pp.35-44
    • /
    • 2009
  • Naphthalene and TNT (2,4,6-trinitrotoluene) are defined by U.S. EPA as possible carcinogenic compounds known to have detrimental effects on the aquatic ecosystem and human body. There are, however, few researches on methods of analyzing micro-levels of naphthalene and TNT dissolved in groundwater. This study introduces and evaluates the newly developed analytical methods of measuring naphthalene and TNT in groundwater by using HPLC-FLD (Fluorescence detector) and MSD (Mass detector). The MDL, LOQ and salt effect of these methods, respectively, are compared with those of conventional methods which use HPLC-UV. For the analysis of naphthalene, HPLC-FLD was set in the maxima wavelength (Ex: 270 nM, Em: 330 nM) obtained from 3D-Fluorescence to be compared with HPLC-UV in 266 nM wavelength. The MDL ($0.3\;{\mu}g/L$) and LOQ ($2.0\;{\mu}g/L$) of naphthalene by using HPLC-FLD were approximately 80 times lower than those analyzed by HPLC-UV (MDL: $23.3\;{\mu}g/L$, LOQ: $163.1\;{\mu}g/L$). HPLC-MSD were used in comparison with HPLC-UV in 230 and 254 nM wavelength for the analysis of TNT. The MDL ($0.13\;{\mu}g/L$) and LOQ ($0.88\;{\mu}g/L$) of TNT analyzed by using HPLC-MSD were approximately 130 times lower than those obtained by using HPLC-UV in 230 nM (MDL: $16.8\;{\mu}g/L$, LOQ: $117.5\;{\mu}g/L$). The chromatogram of TNT analyzed by using HPLC-UV in 230 nM displayed elevated baseline as the concentration of ${NO_3}^-$ increases beyond 21 mg/L, while the analysis using HPLC-MSD did not demonstrate any change in baseline in presence of ${NO_3}^-$ of 63.7 mg/L which is 3.5 times higher than average concentration in groundwater. In conclusion, HPLC-FLD and HPLC-MSD may be used as suitable methods for the analysis of naphthalene and TNT in groundwater and drinking water. These methods can be applied to the monitoring of naphthalene and TNT concentration in groundwater or drinking water.

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF

Analyses of Synchronous Fluorescence Spectra of Dissolved Organic Matter for Tracing Upstream Pollution Sources in Rivers (상류 오염원 추적을 위한 용존 유기물질 Synchronous 형광스펙트럼 분석 연구)

  • Hur, Jin;Kim, Mi-Kyoung;Park, Sung-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.3
    • /
    • pp.317-324
    • /
    • 2007
  • Fluorescence measurements of dissolved organic matter(DOM) have the superior advantages over other analysis tools for applying to water quality management. A preliminary study was conducted to test the feasibility of applying synchronous fluorescence measurements for tracing and monitoring pollution sources in a small stream located in an upstream area of the Sooyoung watershed in Busan. The water quality of the small stream is affected by leachate from sawdust pile and discharge of untreated sewage. The sampling sites included an upstream site, two pipes discharging untreated sewage, leachate from sawdust, and a downstream site. Of the five field samples, the leachate was distinguished from the other samples by a high peak at a lower wavelength range and a blunt peak at 350nm, suggesting that synchronous fluorescence can be used as a discrimination tool for monitoring the pollution. The efficacy of various indices derived from the spectral features to discriminate the pollution source was tested for well-defined mixture of the sawdust leachate and the upstream stream by comparing (1)the difference between measured values and those predicted based on mass balance and the characteristics of the two samples and (2)the linear correlations between index values and mass ratios of the sample mixtures. Of various discrimination indices selected, fluorescence intensities at 276 nm$({\Delta}\lambda=30nm)$and 347 nm$({\Delta}\lambda=60nm)$ were suggested as promising potential discrimination indices for the sawdust pollution source. Despite the limited number of samples and the study area, this study illustrates the evaluation process that should be followed to develop rapid, low-cost discrimination indices to monitor pollution sources based on end member mixing analyses.