• Title/Summary/Keyword: Wave frequency

Search Result 4,122, Processing Time 0.039 seconds

Screening Test for Heart Diseases in the First Grade Elementary School Children in Busan (부산 지역 초등학교 1학년 학생들의 심장질환의 집단검진에 관한 연구)

  • Oh, Jae Min;Park, Hee Ju
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.5
    • /
    • pp.490-494
    • /
    • 2003
  • Purpose : We'd like to determine the incidence of congenital heart disease and arrhythmia in elementary school children in Busan, and to provide adequate prevention and treatment. Methods : A total of 23,802(male 12,909, female 10,893) 1st grade elementary school children living in Busan were studied. All children were 7-8 years old. We obtained their medical history by questionnaire and checked elecrocardiography(ECG). Subsequent screening tests including a 2nd ECG, chest X-ray, phonocardiogram and CBC for the students who had abnormal findings at the first screening test. The third screening test was done for students who had cardiac murmurs or abnormal ECG findings in the second screening test by echocardiogram, treadmill test and 24-hour Holter monitoring. Results : Among 23,802 children participants, 605(2.54%) had abnormal ECG findings at the first screening test. Q wave abnormality(0.58%) was observed most frequently, and complete right bundle branch block(RBBB)(0.26%), sinus tachycardia(0.24%), right axis deviation(0.22%) and ventricular premature contraction(VPC)(0.21%) followed in order. Four hundred and twenty four children participated in the second ECG screening test. Two hundred and two children(47.6%) had an abnormality such as sinus tachycardia(18.8%), VPC(17.8%), or complete RBBB(17.3%). After completing the third examination including echocardiogram, we couldn't find the students with ventricular tachycardia (VT) or SVT at the third arrhythmia screening test. Conclusion : A high incidence of arrhythmia was found in the 1st grade elementary school children in Busan despite their healthy appearances, although fatal heart diseases were not noted. Early diagnosis, adequate preventative measures and treatment will prevent and decrease the frequency of emergent situations like syncope and sudden death.

Effects of Magnetic Resonance Imaging on the Human Body : Analysis of differences according to Dental Implant Material (자기공명영상이 인체에 미치는 영향 : 치아임플란트 재료에 따른 차이 분석)

  • Choe, Dea-yeon;Kim, Dong-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.4
    • /
    • pp.481-489
    • /
    • 2018
  • In MRI examination, when irradiating the human body with RF Pulse to acquire images, the portion of the irradiated RF Pulse energy is absorded into the human body, and this will affect the temperature of the human body. If a metal is inserted into the human body even if the same RF Pulse energy is applied, the SAR value increases and the body temperature changes due to the increase in the electromagnetic wave conductivity of the metal. So we measure and compared with the change in the SAR and temperature in the implant material of the dental implant in Brain MRI examinations. Experiments were performed on a human head model using a 64MHz and 128 MHz RF Pulse frequency generated by a 3.0 Tesla MRI apparatus. And then changed material of dental implants to Titanium and $Al_2O_3$. Using the XFDTD program, the changes in SAR and body temperature around the head were examined. When with Titanium the SAR value and temperature of Brain increased, but with $Al_2O_3$ showed lower SAR and temperature as compared with Titanium. The dental implants were low in SAR and temperature of the head in $Al_2O_3$, which are electrical insulators with low electrical conductivity, compared to Titanium, which is an electrical conductor. It is necessary to study the biologic effect of patient with brain MRI when titanium dental implant material is inserted in the future. Because the maximum value of SAR is much higher than the limit when dental implant material is Titanium. In addition, it is necessary to use an implant of $Al_2O_3$ material to reduce the SAR value and temperature of the Brain in Brain MRI examination.

Comparison of Northgate SD-3 and Modulith SLX Lithotriptors: Treatment Results with 2,000 Renal and Ureteral Stones (Northgate SD-3와 Modulith SLX 쇄석기를 이용한 체외충격파쇄석술의 비교분석: 단일 신결석 및 요로결석 2,000례의 치료결과 분석)

  • Lee, Jun-Young;Jung, Hee-Chang;Moon, Ki-Hak;Cho, Chul-Kyu;Park, Tong-Choon
    • Journal of Yeungnam Medical Science
    • /
    • v.16 no.1
    • /
    • pp.85-93
    • /
    • 1999
  • Some reports have shown a decreased effectiveness of extracorporeal shock wave lithotripsy(ESWL) with newer lithotriptors. We compared the treatment results of ESWL with a second generation Northgate SD-3 and a third generation Modulith SLX device. A total of 2,000 patients underwent ESWL treatments for single urinary calculus between September, 1988 and July, 1998. 1,241 patients were treated with Northgate SD-3 between September, 1988 and December, 1995. And 759 patients were treated with Modulith SLX between January, 1996 and July 1998. The treatment results were compared using chi-square test to determine statistical significance. The overall success rate, success rate according to the location and size, the mean number of sessions, complication rate and retreatment rate were calculated, according to lithotriptor. The overall success rate was 90.6% with Northgate SD-3 and 89.1% with Modulith SLX. With Northgate SD-3 and Modulith SLX, the success rate according to the location was 91.0%(579/636) and 88.1%(236/268) in kidney: 93.2%(517/555) and 89.9%(258/287) in upper ureter: 83.3%10/12) and 94.4%167/177) in middle and lower ureter: 47.4%(18/38) and 55. 6%(15/27) in staghorn stone, respectively. The success rate according to the size of stone with Northgate SD-3 and Modulith SLX for stones with the size under 10mm was 96.1%(612/637) and 93.1%(470/505); from 11mm to 20mm was 87.3%(421/482) and 86.4%(165/191); from 21mm to 30mm, 77.5%(62/80) and 67.5%(23/34): and for stones larger than 31mm was 69%(29/42) and 62.1%(18/29), respectively. Mean number of sessions for successful fragmentation was 1.21 and 1.69, respectively with Northgate SD-3 and Modulith SLX. Retreatment rate was 16.7% and 17.5%, respectively. The complications after treatment were severe pain(6.2% with Northgate SD-3 vs. 2.0% with Modulith SLX), steinstrasse(3.4% vs. 1.9%), fever(1.2% vs. 0.5%) and perirenal hematoma(0.2% vs. 0%) in order of frequency. There was no significant difference in the effectiveness of Northgate SD-3 and Modulith SLX. However, a statistically significant difference was observed between the two lithotriptors. We concluded that ESWL with Modulith SLX is more safe compared to Northgate SD-3.

  • PDF

Electrochemical Evaluation of Cadmium and Lead by Thiolated Carbon Nanotube Electrodes (티올화된 탄소나노튜브 전극을 이용한 카드뮴과 납의 전기화학적 분석)

  • Yang, Jongwon;Kim, Lae-Hyun;Kwon, Yongchai
    • Applied Chemistry for Engineering
    • /
    • v.24 no.5
    • /
    • pp.551-557
    • /
    • 2013
  • In the present study, pristine carbon nanotube (p-CNT) and thiolated carbon naotube (t-CNT) electrodes were investigated to improve their detectabilities for cadmium (Cd) and lead (Pb). In addition, we evaluate which reaction mechanism is used when the electrolyte contains both Cd and Pb metals. Square wave stripping was employed for analyzing the sensitivity for the metals. A frequency of 30 Hz, a deposition potential of -1.2 V vs. Ag/AgCl and a deposition time of 300 s were used as optimal SWSV parameters. t-CNT electrodes show the better sensitivity for both Cd and Pb metals than that of p-CNT electrodes. In case of Cd, sensitivities of p-CNT and t-CNT electrodes were $3.1{\mu}A/{\mu}M$ and $4.6{\mu}A/{\mu}M$, respectively, while the sensitivities for Pb were $6.5{\mu}A/{\mu}M$ (p-CNT) and $9.9{\mu}A/{\mu}M$ (t-CNT), respectively. The better sensitivity of p-CNT electrodes is due to the enhancement in the reaction rate of metal ions that are facilitated by thiol groups attached on the surface of CNT. When sensitivity was measured for the detection of Cd and Pb metals present simultaneously in the electrolyte, Pb indicates better sensitivity than Cd irrespective of electrode types. It is ascribed to the low standard electrode potential of Pb, which then promotes the possibility of oxidation reaction of the Pb metal ions. In turn, the Pb metal ions are deposited on the electrode surface faster than that of Cd metal ions and cover the electrode surface during deposition step, and thus Pb metals that cover the large portion of the surface are more easily stripped than that of Cd metals during stripping step.

Preliminary Study on the Development of a Platform for the Optimization of Beach Stabilization Measures Against Beach Erosion III - Centering on the Effects of Random Waves Occurring During the Unit Observation Period, and Infra-Gravity Waves of Bound Mode, and Boundary Layer Streaming on the Sediment Transport (해역별 최적 해빈 안정화 공법 선정 Platform 개발을 위한 기초연구 III - 단위 관측 기간에 발생하는 불규칙 파랑과 구속모드의 외중력파, 경계층 Streaming이 횡단표사에 미치는 영향을 중심으로)

  • Chang, Pyong Sang;Cho, Yong Jun
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.31 no.6
    • /
    • pp.434-449
    • /
    • 2019
  • In this study, we develop a new cross-shore sediment module which takes the effect of infra-gravity waves of bound mode, and boundary layer streaming on the sediment transport into account besides the well-known asymmetry and under-tow. In doing so, the effect of individual random waves occurring during the unit observation period of 1 hr on sediment transport is also fully taken into account. To demonstrate how the individual random waves would affect the sediment transport, we numerically simulate the non-linear shoaling process of random wavers over the beach of uniform slope. Numerical results show that with the consistent frequency Boussinesq Eq. the application of which is lately extended to surf zone, we could simulate the saw-tooth profile observed without exception over the surf zone, infra-gravity waves of bound mode, and boundary-layer streaming accurately enough. It is also shown that when yearly highest random waves are modeled by the equivalent nonlinear uniform waves, the maximum cross-shore transport rate well exceeds the one where the randomness is fully taken into account as much as three times. Besides, in order to optimize the free parameter K involved in the long-shore sediment module, we carry out the numerical simulation to trace the yearly shoreline change of Mang-Bang beach from 2017.4.26 to 2018.4.20 as well, and proceeds to optimize the K by comparing the traced shoreline change with the measured one. Numerical results show that the optimized K for Mang-Bang beach would be 0.17. With K = 0.17, via yearly grand circulation process comprising severe erosion by consecutively occurring yearly highest waves at the end of October, and gradual recovery over the winter and spring by swell, the advance of shore-line at the northern and southern ends of Mang-Bang beach by 18 m, and the retreat of shore-line by 2.4 m at the middle of Mang-Bang beach can be successfully duplicated in the numerical simulation.

The Changes of Short-Term Memory and Autonomic Neurocardiac Function after 4-10Hz Sound and Light Stimulation - A Pilot Study - (4-10 Hz 빛과 소리자극 후 단기기억력 및 자율신경심장기능의 변화 - 예비연구 -)

  • Lee, Seung-Hwan;Kim, Jin-Hwan;Park, Joong-Kyu;Lee, Kyung-Uk;Yang, Dae-Hyun;Hong, Keun-Young;Chae, Jeong-Ho
    • Sleep Medicine and Psychophysiology
    • /
    • v.11 no.1
    • /
    • pp.29-36
    • /
    • 2004
  • Objectives: Sound and light (SL) stimulation has been used as a method to induce some useful mental states in the fields of psychology and psychiatry. It is believed that sound and light entrainment device (SLED) has some specific effects through synchronization of EEG in patients who use it. Theta frequency is believed to stimulate deep relaxation and short term memory processing. This study was conducted to evaluate if 4-10 Hz SL stimulation can induce relaxation and improve short term memory function. Methods: Ten medical students with no medical or psychiatric problems participated in this study. Subjects were randomly divided into two groups. One group was applied with real SLED was applied to one group (R group) and pseudo SLED to the other group (P group). The two groups were exposed to SL stimulation with SLED 15 minutes a day for 5 days, and after two days rest the two groups were switched over. The Korean Wechsler Adult Intelligence Scale (K-WAIS), Academic Motivation Tests (AMT), Test Anxiety Scale (TAS), Korean Auditory Verbal Learning Test (K-AVLT), and digit span were used to evaluate short term memory. Spielberger's State-Trait anxiety inventory and heart rate variability (HRV) test were used to evaluate degree of relaxation. Results: Compared with S group, R group showed a significant improvement in K-AVLT and digit span after a single application of SL stimulation. But 5-day long application did not reveal any differences between the two groups. A significant change in HRV was observed in 5-day long application of SL stimulation after being switched over to other SLED. Conclusion: This pilot study suggests that 4-10 Hz SL stimulation has some positive influences on short term memory and relaxation.

  • PDF

Development and Reliability of Intraoral Appliance for Diagnosis and Control of Bruxism (이갈이 진단 및 조절용 구내장치의 개발과 신뢰도 조사)

  • Kim, Seung-Won;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.1
    • /
    • pp.69-77
    • /
    • 2005
  • The purposes of this study were to develop and introduce a novel intraoral appliance for bruxism composed of power switch and biofeedback device and further to examine inter- and intra-reliability of the appliance prior to clinical tests. The newly-developed appliance consisted of detection sensors, a central processing unit (CPU), a reactor and a storage unit and a displayer. Compact-sized, waterproof switches were selected as bruxism detection sensor and any sensor activation by clenching or grinding event was processed at the CPU and transmitted, by radio wave, to the reactor and storage unit and triggered auditory or vibratory signal, subsequently producing biofeedback to the patient with bruxism. The data on bruxing event in the storage unit can be displayed on the computer, making it possible analyzing frequency, duration and nature of bruxism. Cast models were obtained from ten volunteers with normal occlusion to evaluate reliability of the appliances. For inter-operator reliability on the intraoral appliances, each operator of the two fabricated the appliance for the same subject and compared the minimal contact forces provoking auditory biofeedback reaction in vertical, lateral and central directions. Intra-operator reliability was also investigated on the appliances made by a single operator at two separate times with an interval of two days. Conclusively, the newly-developed appliance is compact and safe to use in oral circumstance and easy to make. Furthermore, it had to be proven reliability excellent enough to apply in clinical settings. Thus, it is assumed that this appliance with the processor and the storage of data and auditory or vibratory biofeedback function is available and useful to analyze and control bruxism.

Screw Joint Stability under Cyclic Loading of Zirconia Implant Abutments (지르코늄 임플란트 지대주의 나사결합부 안정성에 관한 연구)

  • Lee, Mi-Soon;Suh, Kyu-Won;Ryu, Jae-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.164-173
    • /
    • 2009
  • Purpose: The purpose of this study was to evaluate the effect of abutment material on screw-loosening before and after cyclic loading. Among the different materials of abutments, zirconia and metal abutment were used. Material and methods: Two types of implant systems: external butt joint(US II, Osstem Implant, Korea) and internal conical joint(GS II, Osstem Implant, Korea) were used. In each type, specimens were divided into two different kinds of abutments: zirconia and metal(n=5). The implant was rigidly held in a special holding to device ensure fixation. Abutment was connected to 30 Ncm with digital torque gauge, and was retightened in 30 Ncm after 10 minutes. The initial removal torque values were measured. The same specimens were tightened in 30 Ncm again and held in the cycling loading simulator(Instron, USA) according to ISO/FPIS 1480. Cycling loading tests were performed at loads 10 to 250 N, for 1 million cycles, at 14 Hz,(by subjecting sinusoidal wave from 10 to 250 N at a frequency of 14 Hz for 1 million cycles,) and then postload removal torque values were evaluated. Results: 1. In all samples, the removal values of abutment screw were lower than tightening torque values(30 Ncm), but the phenomenon of the screw loosening was not observed. 2. In both of the implant systems, initial and postload removal torque of zirconia abutment were significantly higher than those of metal abutment(P<.05). 3. In both of the implant systems, the difference in removal torque ratio between zirconia abutment and metal abutment was not significant(P>.05). 4. In metal abutments, the removal torque ratio of GS II system(internal conical joint system) was lower than that of US II system(external butt joint system)(P<.05). 5. In zirconia abutments, the difference in removal torque ratio between the two implant systems was not significant(P>.05). Conclusion: Zirconia abutment had a good screw joint stability in the condition of one million cycling loading.

Differences in Grip Strength by Living Conditions and Living Area among Men and Women in Middle and Later Life (독거여부와 거주지역에 따른 중년기와 노년기 남성과 여성의 악력 차이)

  • Joo, Susanna;Jun, Hey Jung;Park, Hayoung
    • 한국노년학
    • /
    • v.38 no.3
    • /
    • pp.551-567
    • /
    • 2018
  • Demographic and socio-structural information is useful to identify potential welfare recipients who are in need of disease-prevention and intervention services. Thus, the present study aims to explore the differences in grip strength among middle and old-aged adults by living conditions and by living area. The 5th wave data of Korean Longitudinal Study of Aging was utilized. The dependent variable was grip strength, and the independent variables were living alone (living alone or not) and living area (city or non-city). Covariates were age, education, log-transformed household income, spouse existence, body mass index, self-rated health conditions, depressive symptoms, cognitive function, smoking, regular exercise, frequency of meeting with friends, and the number of social participation. Regression analysis was performed for middle-aged men, middle-aged women, old-aged men, and old-aged women, respectively. ANOVA and Chi-test were additionally used to specifically discuss significant results. Cross-sectional weight was applied to all analyses. According to the results, living alone and living area did not have significant effects on grip strength among middle-aged men, old-aged men, and old-aged women. In middle-aged women, however, living alone and living area were significantly associated with grip strength. To be specific, middle-aged women who lived alone in rural areas had the lowest grip strength compared to other middle-aged women. Additional analysis showed that middle-aged women who lived alone in rural areas had risk factors, such as low education level, low income, or high depressive symptoms. It implies that middle-aged women living alone in rural areas may have physical health risks, so they might be in need of disease prevention. This study is meaningful in that it can provide reliable information on the latent welfare recipients by using representative panel data and applying weight values.

Numerical Analysis of the Grand Circulation Process of Mang-Bang Beach-Centered on the Shoreline Change from 2017. 4. 26 to 2018. 4. 20 (맹방해빈의 일 년에 걸친 대순환과정 수치해석 - 2017.4.26부터 2018.4.20까지의 해안선 변화를 중심으로)

  • Cho, Young Jin;Kim, In Ho;Cho, Yong Jun
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.31 no.3
    • /
    • pp.101-114
    • /
    • 2019
  • In this study, we carry out the numerical simulation to trace the yearly shoreline change of Mang-Bang beach, which is suffering from erosion problem. We obtain the basic equation (One Line Model for shoreline) for the numerical simulation by assuming that the amount of shoreline retreat or advance is balanced by the net influx of longshore and cross-shore sediment into the unit discretized shoreline segment. In doing so, the energy flux model for the longshore sediment transport rate is also evoked. For the case of cross sediment transport, the modified Bailard's model (1981) by Cho and Kim (2019) is utilized. At each time step of the numerical simulation, we adjust a closure depth according to pertinent wave conditions based on the Hallermeier's analytical model (1978) having its roots on the Shield's parameter. Numerical results show that from 2017.4.26 to 2017.10.15 during which swells are prevailing, a shoreline advances due to the sustained supply of cross-shore sediment. It is also shown that a shoreline temporarily retreats due to the erosion by the yearly highest waves sequentially occurring from mid-October to the end of October, and is followed by gradual recovery of shoreline as high waves subdue and swells prevail. It is worth mentioning that great yearly circulation of shoreline completes when a shoreline retreats due to the erosion by the higher waves occurring from mid-March to the end of March. The great yearly circulation of shoreline mentioned above can also be found in the measured locations of shoreline on 2017.4.5, 2017.9.7, 2017.11.7, 2018.3.14. However, numerically simulated amount of shoreline retreat or advance is more significant than the physically measured one, and it should be noted that these discrepancies become more substantial for the case of RUN II where a closure depth is sustained to be as in the most morphology models like the Genesis (Hanson and Kraus, 1989).