• Title/Summary/Keyword: Waterproofing activity

Search Result 4, Processing Time 0.024 seconds

A Study on the domestic power plant roof waterproofing system & insulation efficiency (국내 발전소 지붕방수설계 시스템 및 단열 성능에 관한 연구)

  • Chung, Kwang-Ho
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.11 no.1
    • /
    • pp.33-42
    • /
    • 2011
  • As the development of construction technology and new materials, building requirements has been varied gadually. Comfortable environment and serviceability of production activity and energy conservation are being dealt with very seriously. Recently localization of engineering technology of Power Plant, however, construction materials and domestic technology are being developed forcingly. According to above topics this thes is going to study roof waterproofing, thermal insulation and evaluate adiabatic performance and evaluation of properties of waterproofing materials and energy conservation. The results of studying and evaluating of roof waterproofing, thermal insulation and adiabatic performance of Power Plant are as follows. 1. Sheet waterproofing method is better than that of asphalt waterproofing method in that adaptability of wearhertight, thermal resistant, contraction and expansion. 2. It is required to replace polyurethane or ethylene used as thermal insulation with rock wool which is noncombustible materials. 3. It is recommended to usd outer insulation method than inner insulation method due to superioty of outer insulation method. Efficiency of insulation materials used in power plant is generally good except perlite mortar used in the power plant(YGN 1-2, GRI 1-2).

Estimating the Physical Demand of Waterproofing Worker

  • Lim, Tae-Kyung;Lee, Dong-Eun
    • International conference on construction engineering and project management
    • /
    • 2015.10a
    • /
    • pp.101-103
    • /
    • 2015
  • Scientific methods that measure the physical demand requirements of a construction operation have not been arrived at maturity in construction community. It is attributed to the difficulty involved in performing controlled experiments on the operation and its' volatile jobsite environment. This paper presents a method that measures the physical demand requirement of the waterproofing activity and verifies the differences between various operations (e.g., a primer painting and a polyurethane coating) consisting of the activity. Two hypotheses, which are involved in the operations, are summarized as follows: [Hypothesis 1] when one performs the same amount of work; the one's average heart rate required for the polyurethane coating operation is higher than that required for the primer painting operation. [Hypothesis 2] when one performs the same amount of work, the one's break time required for the polyurethane coating operation is longer than that required for the primer painting operation.

  • PDF

Exposure Characteristics of Construction Painters to Organic Solvents

  • Park, Hyunhee;Park, Hae Dong;Jang, Jae-Kil
    • Safety and Health at Work
    • /
    • v.7 no.1
    • /
    • pp.63-71
    • /
    • 2016
  • Background: Construction painters have not been studied well in terms of their hazards exposure. The objective of this study was to evaluate the exposure levels of total volatile organic compounds (TVOCs) for painters in the construction industry. Methods: Activity-specific personal air samplings were carried out in three waterproofing activities [polyurethane (PU), asphalt, and cement mortar] and three painting activities (epoxy, oil based, and water based) by using organic-vapor-monitor passive-sampling devices. Gas chromatograph with flame ionization detector could be used for identifying and quantifying individual organic chemicals. The levels of TVOCs, by summing up 15 targeted substances, were expressed in exposure-index (EI) values. Results: As arithmetic means in the order of concentration levels, the EIs of TVOCs in waterproofing works were 10.77, 2.42, 1.78, 1.68, 0.47, 0.07, and none detected (ND) for indoor PU-primer task, outdoor PU-primer task, outdoor PU-resin task, indoor PU-resin task, asphalt-primer task, asphalt-adhesive task, and cement-mortar task, respectively. The highest EI for painting works was 5.61 for indoor epoxyprimer task, followed by indoor epoxy-resin task (2.03), outdoor oil-based-spray-paint task (1.65), outdoor water-based-paint task (0.66), and indoor oil-based-paint task (0.15). Assuming that the operations were carried out continuously for 8 hours without breaks and by using the arithmetic means of EIs for each of the 12 tasks in this study, 58.3% (7 out of 12) exceeded the exposure limit of 100% (EI > 1.0), while 8.3% (1 out of 12) was in 50e100% of exposure limit (0.5 > EI > 1.0), and 4 tasks out of 12 were located in less than 50% of the limit range (EI < 0.5). Conclusion: From this study, we recognized that construction painters are exposed to various solvents, including carcinogens and reproductive toxins, and the levels of TVOC concentration in many of the painting tasks exceeded the exposure limits. Construction workers need to be protected from chemical agents during their painting works by using personal protective devices and/or work practice measures. Additional studies should focus on the exposure assessment of other hazards for construction workers, in order to identify high-risk tasks and to improve hazardous work environments.

Moisturizing Effect and Durability of Sun Protection Factor (UVA/B) Activity with Multiple Emulsion (W/O/W) System (멀티플 에멀전(W/O/W) 시스템을 이용한 자외선차단성능(UVA/B)의 내수성과 보습효과)

  • Lee, Myoung-Hee;Kim, In-Young
    • Journal of the Korean Applied Science and Technology
    • /
    • v.32 no.2
    • /
    • pp.339-347
    • /
    • 2015
  • This study is to evaluate moisturizing effect and durability of UV A/B blocking activity with multiple (W/O/W) emulsion system. Most of the sun protective products come to be hot issue having both high SPF and long-lasting activity as using special products when is going out, mountain climbing and sports. Also, many consumers prefer the products which have the excellent waterproofing activity of sun care cosmetics as well as the non-sticky feeling that carried out the study of the sensorial science and texture preference. Therefore, development of the specific formulation using this multiple (W/O/W) emulsion technology, it has O/W type hydro skin feel having soft and moist texture when it is treated on the skin. Finally, this formulation is instantly changed to W/O type feel after adsorbed into the skin. The purpose of this study is to get high SPF lasting effect having high water resistance tactivity with high functional multiple (W/O/W) emulsion cream. We used major ingredients, UV-B absorbers were selected with ethylhexyl methoxycinnamate, isoamyl-p-methoxycinnamate, ethylhexylsalicylate, and octocrylene, UV-A absorbers were selected with butylmethoxydibenzoylmethane, bis-ethylhexyloxyphenol methoxy phenyltriazine. SPF effect of O/W type cream was 34.1. SPF effect of W/O/W type cream was 40.6 (increased about 19%). Water resistance effect after 4 hours, SPF effect of O/W type cream was 3.6 (quickly drop down). SPF effect of W/O/W type cream having 81.0 % waterproofing effect was 32.7 (decreased about SPF 7.9). Moisturizing effect of O/W cream at first was superior comparing multiple emulsion. But after 3 hours quickly was drop-down. Moisturizing effect of multiple emulsion was high comparing O/W type and other sun block creams after 4 hours was constantly maintaining water-content.