• 제목/요약/키워드: Waterproofing Method

검색결과 206건 처리시간 0.025초

콘크리트 표면처리용 시멘트 액체방수제의 품질동향 (A Trend on Quality Transformation of Waterproof Agent and Admixture of Cement for Concrete Surface Treatment)

  • 최은수;김영근;박헌일;정순자
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.557-560
    • /
    • 2003
  • This study deals with the method of test for waterproof agent and admixture of cement, and especially, the effect on bond strength between waterproofing layer and mortar or concrete substrate in building construction. Quality of that has been managed according to it of construction standard manual, housing construction manual, 건, and Q until performance of that is specified by law as KS F 4923. Therefore this study focus on the quality and trend for a fatty system and PCM(Polymer Cement Mortar)

  • PDF

공동주택 지하공간 누수 예방 기술 정책 수립을 위한 소비자 인식 분석 연구 (Consumer Awareness Analysis of Residential Building Underground Structure Leakage Prevention Measurements)

  • 한윤정;오규환;김수련;김병일;오상근
    • 한국건설순환자원학회논문집
    • /
    • 제4권4호
    • /
    • pp.379-387
    • /
    • 2016
  • 본 연구에서는 지하부위의 누수 예방 기술 정책 수립을 위한 방수 성능 분석 연구에 대하여 설문조사를 실시하고 이를 분석하였다. 설문 분석 결과, 현재 공동주택 지하공간에 대한 누수는 심각하며, 응답자 대부분도 이를 심각하게 인식하고 있다. 환경을 고려하지 않은 누수설계 및 누수예방 설계의 부재, 환경에 적합하지 않은 시공 시스템의 활용이 누수문제의 주요 원인이라 판단되었으며, 이를 개선하기 위하여 지하부위 외방수공법의 도입을 의무화하고, 설계시 공동주택 지하부위에 적용할 수 있는 표준 방수 기술 및 공법을 수립해야 될 것이며, 지하 시공환경을 고려한 방수 시공방법의 개발의 필요성이 강조되었다. 따라서 상기의 상황을 미루어 볼 때 법-제도에 의해 명시된 방수설계, 재료 및 공법, 유지관리 등을 방수시공의 전반적인 상황 컨트롤할 수 있는 가이드라인의 제시는 필수요소로 부각되었다.

발수제 혼입 방법에 따른 시멘트 모르타르의 물리적 특성 및 발수 성능에 관한 실험적 연구 (An Experimental Study on Physical Properties and Water Repellent Performance of Cement Mortar According to Mixing Method of Water Repellent)

  • 김완수;양현민;김영관;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.99-100
    • /
    • 2019
  • Water repellent and waterproofing agents fail to act work properly if cracks or detachment occurs outside. The method of making mortar was tested by classifying it into two methods: direct water-repellent put in concrete and water-repellent spray to sand method. It was found that the compressive strength was decreased as the amount of water repellent was increased. As a result of measuring the contact angle, all of the specimens were hydrophobic. The spray method showed greater water repellent effect than the direct mixing method.

  • PDF

알루미늄 박판 점착 복합 방수시트를 이용한 고주파 유도가열 방수공법 개발 평가 연구 (Development of High-Frequency Induction Heating Method Using Adhesive Waterproofing Sheet Laminated with Aluminum Sheet)

  • 김윤호;김동범;박진상;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 춘계 학술논문 발표대회 1부
    • /
    • pp.111-114
    • /
    • 2011
  • Waterprooping Method with sheet need to study technology and multilateral verification considering the arctic conditions as low temperature and humidity, which is the result only considered of material aspects without environmental condition in construction But there are no measures up until now. To solve this problem by using high frequency induction heating method developed waterproof sheets, cold (5 ℃ or less) can be applied in a more stable environment, water-resistant materials and construction methods were studied for development. The results of the test showed that high frequency induction heating method is effective for usability in low temperature condition and securement of proper quality than existing Waterprooping Method with sheet need.

  • PDF

습윤 환경 구조물에 적용하는 누수균열 보수용 방수씰의 성능평가 방법에 관한 연구 (A Study on the Performance Evaluation Method of Waterproofing-Seal as Leakage Crack Repairing Material using in Wet Environment Structure)

  • 강효진;우영제;강호경;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2002년도 학술.기술논문발표회
    • /
    • pp.43-48
    • /
    • 2002
  • Since the basement building like the communication hole and etc. is built under the ground where it is pressed by the water, the leakage happens due to the dried-shrinking crack, the sinking crack, the creation of the work-joint of the building and etc. caused by the character of the material and construction way of the reinforced concrete building. Especially, a lot of repair for the leakage cannot help but being taken in temporary way without any noticeable countermeasure. Therefore, this kind of repair is socially criticized many times that this is defective construction even if this costs a lot. The fundamental reason of the above mentioned symptoms can be found in the creation of the work-joint caused by the character of the concrete building, the limitation of the physical performance of the existing water-proof and repair material, the limitation of the construction, the limitation of the physical sustaining performance of the concrete building, the limitation(heat-injury, deterioration) of the constancy of the durability caused by aging and etc. Therefore, in this study, we would like to present the better understanding on the water-proof seal relating to the application at the spot and its test evaluation related data since the necessity of the establishment of the quality control standard and the performance testing way on the relevant water-proof seal is rising a lot to regulate the water-proof technology and the leakage repair technology in accordance with the growth of the demand on the facility.

  • PDF

옥상부 외단열 및 외방수 공법 제안에 관한 기초연구 (A study on the External Insulation and Waterproof Method of Rooftop)

  • Jang, Dae-Hee
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.137-138
    • /
    • 2019
  • To overcome the limitation in relation to thermal insulator's selection and installation method that is suitable for exterior insulation and waterproof construction methods, a production basis of thermal insulators of which manufacturing knowhow is held by companies was ensured and future-oriented construction methods to adopt new materials were applied. Performance verification was conducted through performance and mock-up tests of thermal transmittance on the cross sections where the flexible insulators were applied based on the improved prototype and performance data were obtained. To overcome the biggest drawbacks (walking feeling and damage etc.) in the exterior insulation and waterproof construction method, inserting a protective layer between thermal insulator and water-proof layer was proposed, and polypropylene corrugated cardboards.

  • PDF

지하구조물에 적용하는 누수균열 보수용 방수씰의 성능평가 방법에 관한 연구 (A Study on the Performance Evaluation Method of Waterproofing-Seal as Leakage Cracks Repairing Material using on the Underground Structure)

  • 권시원;권기주;이종용;오상근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.652-655
    • /
    • 2004
  • In these days, repair materials for leakage cannot help but being taken in temporary way without any noticeable countermeasure. This kind of repair is socially criticized many times that is defective construction even if tills costs a lot. It was not arrange the standard for performance evaluation test method and quality maintenance for materials, even it has been used various injection repairing agent. In conclusion, We suggest that the test method for repair materials for leakage to establish the leakage repairing technology as increase of structure demand, so that the necessity of the establishment of the quality control standard and the performance testing way on the relevant water-proof seal is increasing a lot to regulate the water-proof technology and the leakage repair technology.

  • PDF

지하 구조물 외벽에 적용되는 방수재료의 구조체 거동 및 진동 대응 성능 설계 제안 연구 (A Study on the Seismic Performance Design of Waterproofing Materials Applied Single-side Walls on Underground Structures)

  • 김수연;김명지;오상근
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제24권1호
    • /
    • pp.43-50
    • /
    • 2020
  • 본 연구에서는 건설 구조물에 사용되는 건설 자재 중 콘크리트 구조체에 전면 부착 시공되어 건축물의 내외부로부터 스며들거나 넘쳐흐르는 물을 막을 수 있는 차단마감재인 방수재료에 있어 가속 환경 조건 속의 지하 외벽에서의 방수 성능 설계의 일환으로 내진 성능 설계가능성을 제안하고 그 품질검증 시험방법에 대해 검토하였다. 국내외 건설자재 내진설계 현황을 살펴보았을 때, 국내의 경우 아직까지 현행법상 건축 과정에서의 내진설계 규제는 있지만 자재에 대한 규제는 없어 내진용 제품군이 드물고 대부분 시공법에 의존하고 있는 상황이다. 국외의 경우 일본, 캐나다, 독일과 같이 비구조재에 내진성능을 부여한 다양한 건축자재가 개발되고 있음을 확일 할 수 있었고, 이러한 내진설계 개념은 앞장에서 살펴본 바와 같이, 지하 콘크리트 구조체에 전면접착 혹은 부분 부착되어 시공되는 선행 외방수재료에 있어 지진에 대한 보완 대응력을 가질 수 있다면 내진 설계된 구조체와 함께 누수 예방 및 방지 기술로서 그 적용성을 기대할 수 있을 것으로 판단된다.

자동차용 실리콘 와이어 씰의 조립과정에 관한 변형해석 (Deformation Analysis on Assembly Process of Silicone Wire Seal for Automobile)

  • 김진광
    • 동력기계공학회지
    • /
    • 제21권6호
    • /
    • pp.86-93
    • /
    • 2017
  • Silicone rubber wire seals are widely used in automotive connector systems for waterproofing and so on. The purpose of this paper is to predict and evaluate the sealing performance of wire seals using finite element analysis. The material properties of the rubber seals were determined by the curve fitting of uniaxial tensile test and equibiaxial tensile test data. The response surface method was used to determine the optimum shape of the wire seal. In order to verify the accuracy and reliability of the simulations on the deformation prediction of wire seals, experiments were also carried out.

교면용 양면 시트방수재 상부 포장층 재료에 따른 부착방법 변경시 인장접착강도 확인 (Tensile Bond Strength Westing When Changing Adhesion Method of Double-sided Waterproof Sheet Used on Surface Layer of Bridge-deck)

  • 안기원;김천학;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.217-218
    • /
    • 2019
  • In this study, to overcome the limitation of material application as the surface layer of bridge decks (asphalt concrete, concrete), a newly developed waterproof sheet is proposed to be usable for both asphalt concrete and concrete. Subsequent tensile bond strength was tested, and the test results showed that the tensile bond strengths were similar to depending on the type of the surface layer material for bridge decks, confirming the applicability of the proposed material.

  • PDF