• 제목/요약/키워드: Waterproofing

검색결과 471건 처리시간 0.031초

지하 구조물용 비노출형 방수재의 외부환경에 따른 방수재의 성능 변화 요구 (Waterproofing Materials According to the External Environment of Non-exposed Waterproofing Materials for Underground Structures Performance Change Requirement)

  • 정석주;송제영;원승재;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 봄 학술논문 발표대회
    • /
    • pp.85-86
    • /
    • 2020
  • In securing durability of underground structure non-exposed waterproof materials, the company aims to improve durability of waterproof materials by studying more realistic weather conditions than KS standards and developers' durability standards. Analyzing the actual climate data in Korea and the temperature of the basement layer, it is a waterproofing sheet method, a self-adhesive sheet method in which a film and a compound, which are currently widely used as underground water-proofing, and a self-adhesive waterproofing sheet method, etc. We would like to present the guidelines necessary to prevent the temperature situation and waterproof defects that are ideal for setting the endurance conditions later.

  • PDF

원형 접착 절연형의 복합 복층형 노출 방수제와 탈기관을 결합한 옥상 방수 공법에 관한 고찰 (A look at rooftop waterproofing methods that combine a circular adhesive insulated composite duplex exposure repellent with a airvent)

  • 김영석;전상훈
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.236-237
    • /
    • 2021
  • In the waterproofing of the rooftop of reinforced concrete buildings, it is difficult to solve perfectly according to the proficiency of waterproofing materials, methods, and mechanics. Therefore, this study applies a Tricot Fabric Mesh to the behavior of the bottom concrete. In addition, it responds to the behavior of the concrete cracking, and the waterproofing and protective layer has developed a method to provide convenience for rooftop floor use by adhesion between the base and the waterproof layer with the use of high viscosity urethane to effectively move the surface deformation and surface vapor and install a airvent device on the wall.

  • PDF

시멘트 액체방수 시공방법에 따른 부착강도 특성 (Bond Strength Measurement according to the Cement Liquid Waterproofing Method)

  • 이지환;조만기;김진식;김혜원;조성준
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.241-242
    • /
    • 2023
  • In this study, the bond strength characteristics of cement liquid waterproofing are confirmed. Investigation was made on the properties of adhesion strength due to cement liquid waterproof construction methods and changes in curing temperature. It is intended to reduce the possibility of tiles falling off by ensuring the adhesion strength of the cement liquid waterproofing.

  • PDF

Interfacial properties of composite shotcrete containing sprayed waterproofing membrane

  • Park, Byungkwan;Lee, Chulho;Choi, Soon-Wook;Kang, Tae-Ho;Kim, Jintae;Choi, Myung-Sik;Jeon, Seokwon;Chang, Soo-Ho
    • Geomechanics and Engineering
    • /
    • 제16권4호
    • /
    • pp.385-397
    • /
    • 2018
  • This study evaluates the interfacial properties of composite specimens consisting of shotcrete and sprayed waterproofing membrane. Two different membrane prototypes were first produced and tested for their waterproofing ability. Then composite specimens were prepared and their interfacial properties assessed in direct shear and uniaxial compression tests. The direct shear test showed the peak shear strength and shear stiffness of the composites' interface decreased as the membrane layer became thicker. The shear stiffness, a key input parameter for numerical analysis, was estimated to be 0.32-1.74 GPa/m. Shear stress transfer at the interface between the shotcrete and membrane clearly emerged when measuring peak shear strengths (1-3 MPa) under given normal stress conditions of 0.3-1.5 MPa. The failure mechanism was predominantly shear failure at the interface in most composite specimens, and shear failure in the membranes. The uniaxial compression test yielded normal stiffness values for the composite specimens of 5-24 GPa/m. The composite specimens appeared to fail by the compressive force forming transverse tension cracks, mainly around the shotcrete surface perpendicular to the membrane layer. Even though the composite specimens had strength and stiffness values sufficient for shear stress transfer at the interfaces of the two shotcrete layers and the membrane, the sprayed waterproofing membrane should be as thin as possible whilst ensuring waterproofing so as to obtain higher strength and stiffness at the interface.

An Experimental Study of Water Vapor Pressure Change by Ambient Temperature at the Interface between Concrete and Fluid-Applied Membrane Layer

  • Ko, Jin-Soo;Kim, Byung-Yun;Park, Sung-Woo;Lee, Mun-Hwan;Lee, Sung-Bok
    • International Journal of Concrete Structures and Materials
    • /
    • 제3권1호
    • /
    • pp.15-23
    • /
    • 2009
  • Over about 30% of problems in construction is related to water-leaking, and the loss from this problem can incur as much as three times the cost of initial construction. Thus, water vapor pressure is known to be the primary cause of defective waterproofing. Accordingly, the theories on the relationship between water pressure and temperature as well as damp-proofing volume of concrete and the change in vapor pressure volume were reviewed and analyzed in this study by making test samples after spraying a dampness remover and applying waterproofing materials to the prepared test specimens. The result of measuring water vapor pressure with the surface temperature of the waterproofing (fluid-applied membrane) layer at the experimental temperature setting of about $10^{\circ}C$, which is the annual average temperature of Seoul, indicated that (1) the temperature of the fluid-applied membrane elevated to about $40^{\circ}C$, and the water vapor pressure generated from the fluid-applied membrane was about 0.03 N/mm 2 when the surface temperature of the waterproofing layer was raised to about $80^{\circ}C$. (2) when the temperature of the fluid-applied membrane of the waterproofing layer was raised from $30^{\circ}C$ to $35^{\circ}C$, water vapor pressure of about 0.01 N/mm 2 was generated, and (3) when a thermal source was applied to the fluid-applied membrane (waterproofing) layer, the temperature increased from $35^{\circ}C$ to $40^{\circ}C$, and approximately $0.005\;N/mm^2$ of water vapor pressure was generated.

국내 공동주택 지하주차장의 누수 실태 및 주요 누수 부위 조사 (Leakage Situation and Main Leakage Areas of Domestic Residential Building Underground Parking Lots)

  • 이정훈;송제영;오상근
    • 한국건설순환자원학회논문집
    • /
    • 제4권4호
    • /
    • pp.496-503
    • /
    • 2016
  • 본 연구에서는 현재 국내 공동주택 지하주차장의 누수실태를 파악하고, 실제 누수가 가장 빈빈하게 발생되고 있는 주요 누수부위를 파악하여 향후 공동주택 지하부위 누수 예방을 위한 기초자료로 기여하고자 하였다. 18개 단지를 대상으로 누수실태 조사를 진행한 결과 외방수를 적용한 전체 80% 단지에서 누수가 발생되지 않았으나, 내방수를 적용한 단지에서는 전부 누수가 발생되고 있었다. 방수와 관련된 건설분야에 종사하는 전문가를 대상으로 진행한 설문조사 결과, 현재 공동주택 지하주차장의 누수 문제는 심각한 수준으로써, 누수에 대한 대책이 요구되며, 무엇보다 정책적 기준 마련이 중요하다고 판단하고 있다. 누수 실태조사 결과와 설문조사 결과를 비교, 분석한 결과 누수가 빈번한 주요 구조부위는 외벽과 최하층 바닥 슬래브이며, 누수 취약부위는 벽체 시공 이음부와 바닥 신축줄눈으로 판단할 수 있었다. 향후 해당부위의 누수 예방을 위한 방수 설계지침 및 시공시방 등에 대한 후속적인 연구가 필요하겠다.

뿜칠 방수 멤브레인이 시공된 터널 라이닝의 수분이동에 관한 수치해석 연구 (A Numerical study on the Moisture Transport of Concrete Tunnel Linings with the Sprayable Waterproofing Membrane)

  • 이철호;최순욱;강태호;장수호
    • 터널과지하공간
    • /
    • 제26권3호
    • /
    • pp.212-219
    • /
    • 2016
  • 뿜칠 방수 멤브레인은 숏크리트 사이에 시공되어 라이닝 크랙을 통한 누수를 방지하는 목적으로 최근 유럽 국가를 중심으로 시공 사례가 늘어가고 있다. 뿜칠 방수 멤브레인은 방수 시트에 비해 복잡한 단면에도 시공이 용이하기 때문에 이용 사례가 늘어갈 것으로 전망된다. 뿜칠 방수 멤브레인은 폴리머로 구성된 재료로서 투수성이 매우 낮지만 수분의 이동에 의해 포화가 되고 이로인해 콘크리트 재료에 간극수압이나 동결 문제를 일으킬 수 있는 우려가 있다. 본 연구에서는 뿜칠 방수 멤브레인의 수분이동과 계절변화를 고려하여 숏크리트 라이닝의 열-습도 전달 장기 해석을 수행하였다. 해석을 통해 뿜칠 방수 멤브레인의 수분 흡수 작용과 수분 이동으로 인한 상대습도 변화를 고찰할 수 있었으며 이로 인한 장기적 변화를 모사할 수 있었다.

옥내소화전설비에서 도너츠형 적재방식의 소방호스 전개형태에 따른 방수준비시간 비교 (Comparison of Waterproofing Preparation Time with the Unfolded of Donut-type Staking Method Fire Hose in Indoor Hydrant System)

  • 홍석환;공하성
    • 대한안전경영과학회지
    • /
    • 제23권3호
    • /
    • pp.115-122
    • /
    • 2021
  • In this study, the purpose of this study was to examine the effect of twisting in the preparation of waterproofing in the process of unfolded donut-type staking method fire hoses in indoor hydrant system. The central pull-out method caused more twisting than the rolling method, and there was no significant difference in the number of twists according to the pull-out method in the case of male and female students. It was found that the time it took to untwist and prepare waterproofing was much shorter for male students. The angle valve and hose are connected, and the time to untwist and prepare for waterproofing after withdrawing the fire hose with the hose and nozzle connected was shorter than the unconnected state. In the rolling method, when a hose connected with two 15 m fire hoses was used and the angle valve-hose was connected, but the hose-nozzle was not connected, the least kinking occurred. The time to untwist and prepare for waterproofing was also the shortest. As a result, in the withdrawal method of the donut-type loaded fire hose in the indoor hydrant system, it is a rolling method rather than a central withdrawal method. With the angle valve and hose connected, unfold the fire hose with the hose and nozzle connected, if a large number of people unwind the twisted hose, the time to prepare for waterproofing can be shortened.

생산성 및 품질향상을 위한 방수공사의 장비 활용 시공기술 (Enhancing Construction Productivity and Quality Through Waterproofing Equipment Technologies)

  • 김한식;하정수;이영도
    • 한국건축시공학회지
    • /
    • 제23권4호
    • /
    • pp.429-440
    • /
    • 2023
  • 이 연구에서는 방수공사의 장비 활용 시공기술을 통해 작업환경 개선으로 인한 작업자의 사고방지 및 안전을 확보하고, 장비의 활용에 따른 작업 효율성 증대 및 품질을 개선시키며 더불어 기능공 확보의 어려움을 해소하는 것을 목적으로 하고 있다. 시멘트 액체 방수 뿜칠장비를 활용함으로써 부착성능이 약 20% 향상하고 작업속도가 2배 상승하였다. 프라이머 뿜칠 장비를 활용함으로써 침투성능과 부착성능이 약 2배 개선되는 효과를 보였고, 작업속도가 약 2배 상승하였다. 우레탄 뿜칠 장비를 활용함으로써 동일한 도막두께를 확보하는데 작업량을 1/3로 단축할 수 있으며, 부착강도는 약 1.4배 증가하는 결과를 나타내었고, 작업성이 약 1.4~1.5배 향상되었다. 이러한 결과로부터 장비 작업 시 품질향상과 더불어 작업효율이 증대되고, 수작업 환경에서 자주 발생하는 안전사고를 방지함으로써 안전 환경 조성에 기여할 수 있다. 또한 기능공 수급에 대한 어려움 해소가 가능할 것으로 판단된다.

공동주택 방수공사 품질관리 방안 마련에 관한 연구 (A Study on the Quality Control Plan for Waterproof Construction in Apartment Houses)

  • 김광기;김병일
    • 한국건축시공학회지
    • /
    • 제24권1호
    • /
    • pp.109-120
    • /
    • 2024
  • 성공적인 방수 시공을 위해서는 건축에 사용되는 방수재료의 재질적 성능뿐만 아니라 시공 품질을 확보하는 것이 매우 중요하다. 건설경기 침체에 따른 장기적인 원가절감 정책으로 인해 대부분의 건설사에서는 명확한 품질관리 기준이 없는 고급 방수 자재보다는 일반 저가의 방수 자재를 사용하고 있으며, 건설에 대한 명확한 교육 없이 건설 활동에만 의미를 두고 건설을 진행하고 있다. 또한, 복합적으로 적용되는 방수공법은 시공공법이 복잡하여 시공 품질이 부족하고 방수 불량으로 누수가 발생하는 상황에 놓여있으며, 성공적인 방수공사를 위해서는 품질관리 방안(설계, 자재, 시공)을 검토하고, 파생되는 문제점을 개선하여 안정적인 방수공사가 이루어질 수 있도록 하는 것이 필요하다. 건축물의 누수방지 효과를 기대하기 위해서는 먼저 설계단계에서 건축물의 각 부분과 환경에 적합한 자재를 선정하여야 하며, 선정된 자재는 한국산업규격(KS)의 모든 항목을 만족하여야 한다. 둘째, 방수시고의 품질을 확보하기 위해서는 작업자의 성실한 시공이 요구된다. 본 논문에서는 자재 선정 후 품질관리 대책으로 "방수 설계 검토", "시공자 교육", "현장실사", "비평(수정/보완)"에관한 현장점검 체크리스트를 제시하여 현장에서 안전 및 고품질의 방수공사확보를 위한 개선방안을 제시하였습니다.