• 제목/요약/키워드: Water-turbine generator

검색결과 107건 처리시간 0.025초

수차발전기 축계의 진동해석 (Vibration Analysis of Hydraulic Turbine-Generator Rotor)

  • 김용한;손병구;최병근;양보석;하현천
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1998년도 춘계학술대회논문집; 용평리조트 타워콘도, 21-22 May 1998
    • /
    • pp.250-254
    • /
    • 1998
  • Pump-storage power plants, which pumps water from the lower reservoir to the upper reservoir using the extra electronic power at night and generates the electronic power in the daytime, are more increasing. Currently it has a tendency to be high-head large-capacity machines. So in the processing of design, we need to know the vibration characteristics of pump-turbine shaft system sufficiently. In this paper, we developed the computer programs for analyzing pump-turbine shaft system considering magnetic force of generator, hydraulic force at runner, dynamic characteristics of guide bearings and the effect of add mass of water. And the superiority of this program was verified by applying it to the real model and calculating high quality critical speed, natural mode and unbalance response.

  • PDF

서로 다른 자석 배열을 가지는 와전류 열원화 장치의 성능 측정 (Performance Measurement of the Eddy Current Heat Generator with Different Array of Permanent Magnets)

  • 윤택한;손영우;이장호
    • 신재생에너지
    • /
    • 제9권1호
    • /
    • pp.17-24
    • /
    • 2013
  • Eddy Current is one of ways to make heat using rotational energy of wind turbine rotor. Four difference arrays of permanent magnets around rotor surface are used to generate heat using eddy current in this study. For the evaluation of heating performance, new test rig is prepared to measure water flow and temperatures in the inlet and outlet of the eddy current heat generator. In the test, torque and rotational speed are also measured in the motor driven system, and evaluated if the torque is matched with it of wind turbine rotor or not. It will be shown that the eddy current heat generator can be applied to real urban wind energy systems in this study.

흡습된 수냉각 발전기 고정자 권선의 전기적 특성 (Electrical Properties of Wet Bars in Water-cooled Generator Stator Windings)

  • 김병래;김희동
    • 한국전기전자재료학회논문지
    • /
    • 제25권10호
    • /
    • pp.817-823
    • /
    • 2012
  • Insulation breakdown of water-cooled generator stator windings occurs frequently due to leakage of cooling water and absorption into the insulation material. Leakage and absorption problems of water-cooled stator windings are often found during regular preventive maintenance. To evaluate cooling water leakage and absorption, diagnostic tests were performed on two water-cooled turbine generators, which have been in service for 13 and 17 years, respectively. The test results of the measured electrical properties such as dissipation factor($tan{\delta}$), capacitance and AC leakage current for water-cooled generator stator windings with wet bars are reported in this paper.

가청화를 이용한 댐 수차 발전기소음의 저감효과 평가 (Evaluation on Reduction Effect about Noise of Hydraulic Turbine Dynamo in Dam using Auralization)

  • 설수환;주덕훈;김재수
    • 설비공학논문집
    • /
    • 제20권6호
    • /
    • pp.400-408
    • /
    • 2008
  • Multipurpose Dam, it produces electric energy by converting the potential energy into kinetic energy utilizing its head and quantity of the water. However, in this process, since during the time when the turbine connected to the hydraulic turbine generator revolves, there occurs a ceaseless loud noise, and due to this condition, it is true state that those people who work at inside of the power plant are damaging as hard as they are unable to concentrate on their work. Not only this, because the hydro-electric power generator room that locates at middle section between the hydraulic turbine room and the office is very large space volume, also since it was constructed chiefly by the reflecting material, it is functioning of amplify the noise when operating the generator, the soundproof measure against this condition is necessitated. On such viewpoint, I have presented the problem point of the relevant Hydraulic turbine dynamo and Hydraulic turbine dynamo room, and after improve such problem point, this study has ever investigated the satisfying degree about the noise-reduction at before and after of the improvement of soundproof measure, using the Auralizational technique that can experience virtual acoustic field. It is considering that such result could be utilized usefully as the fundamental material hereafter for the acoustic performance of the hydro-electric power generator room in dam and when its construction.

20kW OTEC 터빈 개발 (20kW Turbine Development for OTEC System)

  • 한상조;서종범
    • 한국유체기계학회 논문집
    • /
    • 제17권6호
    • /
    • pp.38-43
    • /
    • 2014
  • In Ocean, the temperature of the deep sea water is always lower than that of the surface sea water. The temperature difference between the surface water and deep sea water is about $20^{\circ}C$. Based on thermodynamics, this temperature difference can be converted into mechanical power. The mechanical power can be converted to electricity through a generator. However, the temperature difference is relatively small compared with that of traditional steam turbines. It is difficult to apply the steam turbine technology for this small temperature difference directly. Therefore, the turbine for OTEC system using low temperature difference should be designed to meet the system requirement. The present study focuses on the development of the turbine for 20 kW OTEC system using R32. The paper includes the determination of working fluids, meridional design, turbine layout and 3D CFD results. With off-design points analysis, the full performance of 20kW OTEC turbine is investigated. Through the research, one stage radial type turbine with R32 as working fluid is successfully developed and can be applied to other high temperature heat source.

국내 소수력발전 기술개발 현황과 전망 (Overview and Trend of Small Hydropower Development in Korea)

  • 이경배;이은웅
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2005년도 연구개발 발표회 논문집
    • /
    • pp.735-741
    • /
    • 2005
  • We have studied the prearranged plan and the economy of a candidate site for the development of small hydro power. And also we have confirmed its economy by suggesting the technology of the unmanned operation and the selection of the water turbine generator which has a great efficiency, working rate and suitability to the topographical characteristics of various development sites, for example, irrigation reservoirs, water works pipes, sewage systems and cooling water of a steam power station. We proposed some opinions such as the better improvement of small hydropower industry the people' view, cooperation among industry/university/ research institutes, remote control/maintenance and goverment's legislature and supporting system etc.

  • PDF

고정자 권선용 F종 주절연 테이프의 전기적 특성 (Electrical characteristics of class-F groundwall insulation tapes for stator windings)

  • 김태희;강명국;이재권;손삼용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1679-1681
    • /
    • 2004
  • Class-F and B resin-rich type insulating tapes are generally used for the ground wall insulations of respective air-cooled and water-cooled stator windings in larger turbine generators. In this paper, their electrical properties coupled with aging times in higher temperature than designed one in normal condition were experimentally investigated and the results of two comparative tests were presented on the existing class-F resin-rich type tape and a developed one after curing. The resin-rich tapes currently used arc composed of six and a half 3-layer sheets that arc structured with mica paper, the top and bottom supports of it respectively, and the epoxy resin to bind them tightly. The results for breakdown voltage and strength on the cured specimens were presented, which were composed of the unaged, the aged accelerated for one, two, and three thousand hours at 180 $^{\circ}C$. The surface and volume resistivities on them were measured and the results are also presented to make a comparative test for the initial electrical characteristics.

  • PDF

정수장 마이크로 소수력 발전기 적용에 대한 연구 (A Study on the Application of Micro Hydro Power Generator at the Water Treatment Plant)

  • 김종겸;박영진;김일중
    • 조명전기설비학회논문지
    • /
    • 제28권9호
    • /
    • pp.67-72
    • /
    • 2014
  • Inflow or outflow from the water treatment plant and the sewage water has potential energy. If this potential energy can be converted into electrical energy by water turbine generator, it can help to save energy because of the high capacity utilization. So recently, micro hydro power plant is reviewed in the water treatment facility. If generation capacity is low, induction generator is primarily used. If output capacity is low, generated power is supplied to the inside load. Induction generator can cause voltage drop by the inrush current at a start-up and requires reactive power for magnetization. In this study, we analyzed the flow of power and voltage variation against inrush current that occurs when the induction generator starts under the terms that loads of linear and non-linear of the water purification plant are used. Analysis results are that the voltage drop is within an allowable range and the power factor is slightly reduced by the need of reactive power.

가변속 유체토르크 컨버터를 이용한 풍력발전 시스템 연구 (A Study of the Wind Turbine System by Variable Speed Hydraulic Torque Converter)

  • 정경원;김동용;김희규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1114_1115
    • /
    • 2009
  • The wind most of the century, the average wind speed in the coast area 6m/s~8m/s operation as a large wind power generators is not enough to produce. But the generator of proposed wind turbine system is connected to Hydraulic torque converter is the actual development of this usage, the low investment and economic effects appear to be much lower there is. In case of the proposed wind turbine system, is possible to make torque transmission long distance, set up generator somewhere in between the tower or the ground as well as, nacelle weight can be greatly down.

  • PDF

소수력 발전에 대하여

    • 기술사
    • /
    • 제15권1호
    • /
    • pp.32-35
    • /
    • 1982
  • The sudden shock of repeated oil crisis and the subsequent violent increases in petroleum prices have given rise to an intensive worldwide effort to develop alternate sources of clean energy. Against this background, a great deal of attention has recently come to be focused on mini-scale hydroelectric power turbine generation. There is now a strong demand for the development of a hydroelectric generator suitable for generating power on a small scale and copable of overcoming the high per kilowatt cost of conventional one's then Francis turbine. Hence was accordingly developed the "Cross flowturbine generator" of 1000kw and less, which we call. This mimi-scale water turbine is reliably and easily handled and also can be economicaly manufactored in a range with effective head of over 3meter's a flow rate of minimum 30 liter per sec and an output of below 1000kw good's.kw good's.

  • PDF