• Title/Summary/Keyword: Water-proof

Search Result 185, Processing Time 0.045 seconds

An experimental study on the Performance Evaluation of High Performance Polyurea Resins (고성능 폴리우레아 수지의 기본적 물리/화학적 성능평가에 관한 실험적 연구)

  • Kim, Yun-Ho;Choi, Eun-Kyu;Seo, Hyun Jae;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.11a
    • /
    • pp.43-45
    • /
    • 2011
  • As technologies evolve, building large concrete structures ever built, but due to lack of maintenance after completion of concrete corrosion, leaks, and preparedness from the problem that is an urgent need. In particular, water-resistant variety of concrete structures. How the concept applies to the most important public drinking water purification and drinking water that is draining the production and storage, and distribution as the structure cause damage to the structure when the contaminated water is supplied to each home that can harm the health of citizens is the cause. Therefore, the correct choice of materials, and thorough a lot of investment in construction and maintenance should have. In this study, unlike conventional water-proof materials, methods, and in other reactions easily than conventional poly-urea resins have good physical performance and chemical resistance, high performance polyurea resin performance review of the physical infrastructure of the country for the longevity of would like to make long-term durability.

  • PDF

A Study on Heavy Metals at the Consumer s Tap in Seoul (서울市 一部 水道栓水中 重金屬에 관한 調査硏究)

  • Lee, Byung Mu
    • Journal of Environmental Health Sciences
    • /
    • v.10 no.2
    • /
    • pp.41-51
    • /
    • 1984
  • This study was performed using samples collected at Myungryundong and at Reservoirs. The purpose of this study was to investigate the differences of water quality between tap and raw water, and to analyse drinking water quality by Fe, Zn from corroded galvanized steel pipe. Results were as follows 1. The older the pipe was, the higher the concentration of Ferrum and Zinc was (t-test : p<0.05). Ferrum and Zinc also exceeded the limits in the older galvanized steel pipe. I think that this comes from the corrosion of pipe. 2. Mercury, Arsenic, Cadmium, Lead, Chomium, Argentum and Aurum not detected in raw water were not detected in tap water. Cobalt, Bismuth and Molybudenum detected in raw water were not detected in tap water. I think that this comes from the quality of raw water, the result of water treatment and the improbability of detection of above metals in water delivery system. 3. Silicon measured 2.4698ppm in raw water, but it ranged from 0.4769ppm to 1.982 ppm in tap water. Manganese measured 0.0638ppm in raw water, but it ranged from 0.0026ppm to 0.0198ppm in 17cases(31%) out of 55samples in tap water. I think that this comes from the water treatment. 4. Aluminium not detected in raw water was found in 17 cases (31%) out of the samples (55cases). It may be considered as the use of coagulants $Al_2(SO_4)_3$. $18H_2O$ and PAC (Poly Aluminium Chloride). The concentration of copper in tap water was much higher in 2 cases(3.6%) out of the samples(55) than that of copper in raw water. I think that this may come from the use of ${CuSO}_4$, the preventive of algae growth, and the result of chlorination, but further study must be necoessary to support the proof.

  • PDF

A Study on Minimizing for Hydration Heat Cracks of a Subway Concrete Box Structure (지하철 콘크리트 BOX 구조물의 수화열에 의한 균열저감 대책 연구)

  • Kim, Eun-Kyum;Youn, Seok-Goo;Bae, Sang-Il;Jeong, Jae-Yong;Kim, Hyeon-Cheol;Heo, Jeong-Ok
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.425-428
    • /
    • 2006
  • The bigger of concrete strctures by a construct technique improvement, and the increase of the cement quantity which is caused by with use of the high-strength concrete for the load-carrying-capacity and a durability cause temperature cracks by a heat of hydration. The temperature crack due to the heat of hydration classified a nonstructural crack. but it has a bad effect on durability of concrete structures. especially, in case of a subway concrete box structure, when a water-proof facilities is beaked on an outer-wall, the water leakage occurs through a penetration crack generated from a wall of the concrete structure too. This paper, for the subway concrete box strucuture, the use of blended cement, the temperature of air and concrete, control joint, was considered and analysed by a three dimensional finite element method.

  • PDF

A Counterplan of temperature crack control by a heat of hydration of Subway concrete box structure concerned External Temperature (대기온도를 고려한 지하철 콘크리트 Box 구조물의 수화열에 의한 온도균열제어 대책)

  • Roh, Hyun-Sup;Kim, Eun-Kyum;Yang, Sin-Chu
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.581-584
    • /
    • 2007
  • The subway concrete box structure can`t establish expansion joint because of animal power delivery of the subway rail. In this case, As increase of structure volume, it is subjected to cause temperature crack. The temperature crack due to the heat of hydration classified a nonstructural crack. but it has a bad effect on durability of concrete structures. especially, in case of a subway concrete box structure, when a water-proof facilities is beaked on an outer-wall, the water leakage occurs through a penetration crack generated from a wall of the concrete structure too. This paper, for the subway concrete box structure, examined a condition of temperature crack occurrence by a heat of hydration concerned external temperature from analysing by a three dimensional finite element method.

  • PDF

Ultrasonic Spray Nozzle System with Piezoelectric Device for Chemicals Dispersion (압전체를 이용한 약품 분사용 초음파 분사노즐 시스템)

  • Koh Jea Seok;Kim Yong Hyun;Choi Seung Chul
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2003.11a
    • /
    • pp.278-281
    • /
    • 2003
  • A new type of ultrasonic spray nozzle was fabricated with piezoelectric devices. The spray nozzle was designed for the chemicals dispersion in the water purification bath. The piezoelectric properties in ultrasonic spray nozzles were optimized for the better dispersion of chemicals for purification process. Ultrasonic spray nozzle was packaged in metal case with silicone resin for the water proof application.

  • PDF

A Study on the Recovery of Carbon Energy by Thermophilic Aerobic Digestion (고온호기성 소화공정을 이용한 탄소원 회수에 관한 연구)

  • Yi, Yunseok;Kim, Ryunho;Yun, Zuwhan
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.6
    • /
    • pp.906-912
    • /
    • 2007
  • A lab-scale thermophilic aerobic digestion (TAD) system was operated at $64^{\circ}C$ with mixed primary and secondary sludges taken from a large wastewater treatment plant. The semi-continuously operated reactor at HRTs of 1, 3 and 6 days indicated that longer HRT could stabilize sludge organics and solids comparable to anaerobic digestion. It has been found that reduced HRT of 3 and 1 day produced the effluent with highly biodegradable soluble organics, indicating the possibility of energy recovery in TAD. No proof of biological nitrification was observed at thermophilic operating temperature of $64^{\circ}C$, while nitrogen removal seemed due to nitrogen exertion during the aerobic thermophilic cell synthesis as well as ammonia stripping.

Reinforcement of Concrete Structure by Impregnation of Molten Sulfur (용융황 침투에 의한 콘크리트 구조물의 물성 증진에 관한 연구)

  • 김종국;오준택;설용건;김우식
    • Journal of the Korean Ceramic Society
    • /
    • v.26 no.6
    • /
    • pp.729-736
    • /
    • 1989
  • This study aims to reinforce concrete structure by impregnation of molten sulfur. The improved properties of sulfur impregnated concerete were confirmed by compressive strength test and water proof effect. Following variables were adopted to evaluate impregnation parameters ; 1) the effect of water content in concrete structure (0-8%) 2) impregnation time of molten sulfur(0-22hr) 3) impregnation temprature of molten sulfur(13$0^{\circ}C$, 14$0^{\circ}C$). In partial ponding experiments, the concrete specimen of sulfur impregnated by 2wt% yields 1.5 times higher value of compressive strength than that of control one(non-impregnated concerte). In complete ponding experiments, the mortar specimen of slufur impregnated by 12-14wt% yields 2-3 times higher value of compressive strength than that of control one (non-impregnated mortar). From the examination of X-ray diffractions, $\alpha$-sulfur was found in concrete pores. Homogeneous impregation of molten sulfur into concrete pores was also identified with poresize analysis and micrographs of SEM.

  • PDF

A Study on Minimizing for Hydration Heat Cracks of a Subway Concrete Box Structure (콘크리트 BOX 구조물의 수화열에 의한 온도균열제어 대책)

  • Kim, Eun-Kyum;Jeon, Chan-Ki;Jeon, Joong-Kyu;Bae, Sang-Il
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.705-708
    • /
    • 2006
  • The bigger of concrete structures by a construct technique improvement, and the increase of the cement quantity which is caused by with use of the high-strength concrete for the load-carrying-capacity and a durability cause temperature cracks by a heat of hydration. The temperature crack due to the heat of hydration classified a nonstructural crack. but it has a bad effect on durability of concrete structures. especially, in case of a subway concrete box structure, when a water-proof facilities is beaked on an outer-wall, the water leakage occurs through a penetration crack generated from a wall of the concrete structure too. This paper, for the subway concrete box structure, which is located in chloride attack region, the use of blended cement, the temperature of air and concrete, was considered and analysed by a three dimensional finite element method.

  • PDF

Design of a Water Level Plate to Reduce Vibrating Noise of Washing Machine (세탁기의 진동소음 저감을 지원하는 자동 수평 평판 기구설계)

  • Park, Dong-Yeun;Jung, Jae-Hyun;Ko, Kuk-Won;Kim, Sung-Ki
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2014.11a
    • /
    • pp.1203-1204
    • /
    • 2014
  • 세탁기에서 등속 원운동(uniform circular motion)시 발생하는 힘으로 인해 생기는 소음 및 진동을 트라이포드 수평계(tripod water level)의 자동 수평맞춤 센서 장치, 방진고무(vibration proof rubber)를 장착한 최적의 진동흡수 평판 기구를 설계 하고자 한다. 본 연구의 결과는 세탁기 소음으로 인한 층간소음 문제 해결에 기여 할 것이다.

Moistureproof Characteristics of Woodboard Types with Surface Thermal Changes (목질 보드류의 표면 열변화에 따른 접촉각(방습) 특성)

  • Shin, Sang-Ho;Liim, Nam-Gi
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.161-162
    • /
    • 2020
  • In this study, as part of securing related data, water droplets were dropped on the upper part of the wooden board for flooring in an environment such as floor heating, and the degree of absorption according to the surface temperature change was tested. The test results showed that the contact angle of the surface was low (25℃→40℃) or the droplet was absorbed into the small plate and disappeared. The contact angle of the OSB and MDF was decreased within 30 minutes, but the surface water droplet was maintained longer than the plywood. This is because the surface is coated with hydrophobicity unlike the plywood, but moisture absorption in the cross section after the second processing will not be prevented and it will lead to defect occurrence problem.

  • PDF