• Title/Summary/Keyword: Water-meter

Search Result 641, Processing Time 0.034 seconds

A Fundamental Study on the Contaminants Using in Place of the Soapy Water for Floor Slip Resistance Test (바닥의 미끄럼시험에 사용되는 비눗물 대체 물질에 관한 기초적 연구)

  • Kim, Dae-Kyu;Shin, Yun-Ho;Choi, Soo-Kyung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.11a
    • /
    • pp.156-157
    • /
    • 2015
  • The safety concern of slipping on floors in South Korea has come to the fore as a social problem, but the occurrence of such accidents has not decreased. Slip and fall accidents have several causes, but they are especially common when there is soapy water on the floor during a shower or a bath. Despite this situation, it can be said that there is a lack of standards on surface contamination materials used in floor slip resistance testing. Therefore, in this study, we conducted a survey to identify the components and quantity of soapy water that actually results from a user taking a shower, and the standardization of contamination materials. Based on the results of this experiment, we provide a surface contamination material that can replace the soapy water used in floor slip resistance testing.

  • PDF

Design of the Real-time Water Tank Wireless Control System in a Ship Using the RF and PLC (RF와 PLC를 이용한 실시간 선박용 물탱크 무선 제어 시스템 설계)

  • Park, O.D.;Lee, S.H.;Kim, H.S.;Long, Nguyen Phi;Hieu, Nguyen Hoang;Kim, H.S.;Cha, C.S.
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.288-290
    • /
    • 2006
  • This paper presents the real-time water tank wireless control in a ship using duplex RF modules and PLC(Programmable logic Controller). The purpose of this paper is developing HMI(Human Machine Interface) for automation equipments. The system can low a cost because long wires are no more used. Analog signals of the water gauge and flow meter are changed to discrete signals by the micro-processor. The PLC checks the volume of water and runs On or Off of the valve and pump. Duplex RF modules send and receive data between the water tank and control room. Everywhere the Internet is used, operators are able to check the status of the system by the web-server.

  • PDF

A development of new dielectric tracer test method for groundwater logging: laboratory soil column test (지하수 검층을 위한 새로운 유전율 추적자 시험법의 개발)

  • Kim Man-Il;Kim Hyoung-Soo;Jeong Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.14 no.3 s.40
    • /
    • pp.301-311
    • /
    • 2004
  • This study is suggested a new dielectric tracer test method to understand geological structure of porous media and groundwater flow to use the dielectric constant which is one of electrical special quality of various geological materials. To measure their parameters, tracer material is made an ethanol mixing liquid(EML) having a same specific gravity of water. Also, soil materials are prepared a dielectric tracer test using the FDR system that could measure dielectric constant for saturated standard sand and river sand layers which have different initial porosity. To compare with their results, we discussed with the concentration variation of saline water having a saline concentration $3\%$ which is general tracer material by using the electro multi-meter system in the laboratory or field test. In two tracer experiment results, EML tracer test could confirm definitely EML concentration variation from each saturated soil layer as standard and river sands. However, tracer test of saline water $3\%$ concentration could not confirm permeating movement of water by degree of salinity change because these are settled at lower part column in a whole column area continuously. These causes are that specific gravity of saline water is heavier than water. That is, it could know that deposition of saline water is composed of lower part of soil column continuously independently of the direction of water into saturated soil material.

Automatic Control of Coagulant Dosing Rate Using Self-Organizing Fuzzy Neural Network (자기조직형 Fuzzy Neural Network에 의한 응집제 투입률 자동제어)

  • 오석영;변두균
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.10 no.11
    • /
    • pp.1100-1106
    • /
    • 2004
  • In this report, a self-organizing fuzzy neural network is proposed to control chemical feeding, which is one of the most important problems in water treatment process. In the case of the learning according to raw water quality, the self-organizing fuzzy network, which can be driven by plant operator, is very effective, Simulation results of the proposed method using the data of water treatment plant show good performance. This algorithm is included to chemical feeder, which is composed of PLC, magnetic flow-meter and control valve, so the intelligent control of chemical feeding is realized.

Water loss Control in DMA Monitoring System Used Wireless Technology

  • Malithong, P.;Gulphanich, S.;Suesut, T.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.773-777
    • /
    • 2005
  • This article is about using information technology to apply with water loss inspection system in District Metering Area (DMA). Inspector can check Flow rate and Minimum Night Flow; NMF via Smart Phone or PDA include sending SMS Alert in case the Pressure, Flow rate and NMF is over the range of controlling. This will be used as equipment to implement water loss in international proactive and can keep on water loss reduction more efficiency. The system consists of Data Logger which collects data of Flow rate from DMA Master Meter. PC is Wap Server which dial via modem in order to get data through FTP Protocal that will convert text file to Microsoft Access Database. Wappage will use xhtml language to show database on Wapbrowser and can show the result on Smart Phone or PDA by graph and table for system analysis.

  • PDF

Water mass and Tidal current of Karnak Bay In May-June 2004 (2004년 5-6월 가막만의 수괴분포 및 조류 특성)

  • Lee Moon-Ock;Kim Byeong-Kuk;Kim Jong-Kyu
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.143-148
    • /
    • 2004
  • In order to see physical characteristics of water masses and tidal currents in Gamak Bay, some field surveys have been conducted using ADCP, Aanderaa current meter and CTD from May 17 to June 3, 2004. The northwest of the bay appeared to have a high temperature and a high salinity so that it coincided with the previous results. The distribution of temperature and salinity seemed to reflect the characteristics of water masses. At the south mouth of the bay, a northwestward-southeastward flow was dominant at the surface layer while a northeastward-southwestward flow was dominant at the bottom layer.

  • PDF

Prediction of water demand using deep learning and smart water meter (스마트 수도미터와 딥러닝을 활용한 수용가별 물 사용량 예측)

  • Kim, Jongsung;Song, Jaehyun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.394-394
    • /
    • 2022
  • 최근 스마트 수도미터의 보급을 통해 수용가구별 물 사용 자료를 수집할 수 있다. 이런 수용가구별 물 사용 패턴은 주말, 날씨 등 다양한 요인으로 인해 비선형적 특성을 가지고 있다. 그로인해 전통적인 시계열 예측 모형인 ARIMA 모형으로 적용하기 어렵다. 따라서 본 연구에서는 딥러닝 기반의 LSTM 모형을 통해 수용가구별 물 소비량 예측 모형을 개발하였다. 이 모형은 비선형적인 물 소비 패턴을 학습하기 위해 다양한 변수를 고려하였다. 서로 다른 종류의 4개 type (A : 단독주택, B: 아파트, C: 음식점, D : 초등학교)의 수용가구에 대한 ARIMA 모형과 LSTM 모형을 개발하였고, 학습에 사용되지 않은 새로운 데이터를 적용하여 정량적으로 예측성능을 비교했다. 그 결과, 모든 수용가구에서 LSTM 모형이 ARIMA 모형보다 성능이 우수하였다 (상관계수 : 평균89% | RMSE : 평균 5.60m3). 따라서 본 연구에서 제안한 모형은 수용가구별 물 사용량을 예측하는데 높은 활용도를 보일 것으로 기대된다.

  • PDF

Investigation on Under-registration of 20 mm to 50 mm Water Meters (20~50mm 수도계량기 미감지율 조사분석)

  • Ahn, Jae-Chan;Ha, Sung-Ho;Park, Tae-Jun;Kim, Sug-Jung;Koo, Ja-Yong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.5
    • /
    • pp.582-594
    • /
    • 2005
  • The under-registration of water meters of 20mm to 50mm in diameter, installed in Seoul city, was estimated by random sample method. The sample sites and sampled meters were selected for the measurements of flow rates and accuracy tests, respectively. The measurement of flow rates was conducted for 20mm to 50mm meters for about 20 days per site using flow meters and data loggers. The under-registration of 20mm, 25mm, 32mm, 40mm, and 50mm meters was observed as 3.96%, 1.10%, 2.47%, 4.04%, and 1.04%, respectively. The under-registration might be increased more or less as malfunction and failure of the sampled meters was not considered. In this study the under-registration of 20mm, 25mm, 32mm, 40mm, and 50mm meters was accurately estimated on the basis of the investigation data. The estimation of under-registration of water meters, one of the basic figures in water industry, contributed to accurate calculation of leakage, water supply and consumption, and strategic planning to reduce the unaccounted-for water.

Leakage Control and Application Using the Pressure Reducing Valve (압력제어밸브를 통한 누수량의 추정과 활용)

  • Kim, Shin-Geol;Kim, Youn-Hwan;Kim, Kyoung-Pil;Koo, Ja-Yong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.2
    • /
    • pp.197-206
    • /
    • 2006
  • The leakage in the water distribution system means both the loss of money and water resource. To minimize the leakage, we introduced the pressure control method using the pressure reducing valve and pump schedule. For the pressure control, the total leakage is needed to divide into each node. In this study, EPANET 2.0 was used to simulate the water networks in two selected blocks after the total leakage was distributed with each node by four ways. The leakage was allocated into each node as water measured by meter, water pressure, water faucets and Lpcd and simulated by EPANET 2.0. Regardless of the leakage distribution ways, there was no significant difference between the measured water and the estimated water pressure. Thus, the leakage distribution way using water pressures estimated by simulation could be recommended. The scenarios controlling the pressure reducing valve and pump were made in two blocks(A and B). $86,713m^3/year$ leakage in the A block and $11,442m^3/year$ in the B block could be reduced as controlling the pressure reducing valve and pump schedule. It was shown that the fifty million won a year can be saved in the A block and 6.8 million won in the B block.

An Experimental Study on the Application of Measuring Method of Water Content for Quality Control of Concrete (콘크리트 품질관리를 위한 단위수량 측정 기법의 적용성에 관한 실험적 연구)

  • Kim, Yong-Ro;Choi, Il-Ho;Jung, Yang-Hee;Lee, Do-Bum
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.2
    • /
    • pp.179-188
    • /
    • 2007
  • Recently, the concern on the receipt of poor ready-mixed concrete in the construction field and the durability of concrete has been increased. Based on the such background, a large number of measuring methods of water content for fresh concrete have been developed and enforced in a developed country. In this study, to investigate practicality for quality control of ready-mixed concrete among various water content measurement techniques, microwave range method, air meter method and capacitance measurement method as measuring methods of water content were selected. Then, it was evaluated estimating performance of water content according to the change of binder types, fine aggregate types, absorption ratio, water content and water-binder ratio in series I and II. Also, it was examined influence on error occurrence of water content according to change of properties of used materials in series III. Finally, based on this study, it was proposed fundamental data to utilize measurement technique of water content to quality control of ready-mixed concrete in construction field.