• Title/Summary/Keyword: Water-Supply

Search Result 3,505, Processing Time 0.031 seconds

Evaluation of Corrosion Index by Water Quality Parameters in Korea (국내 수질에 적합한 부식성지수 선정 연구)

  • Ahn, Kyunghee;Yu, Soonju;Park, Sujeong;Kwon, Ohsang
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.4
    • /
    • pp.615-623
    • /
    • 2012
  • In this study, we evaluate the corrosion indexes (CI) such as Langelier Index (LI), Larson ratio (LR), Ryznar saturation index (RSI), Aggressiveness index (AI) of water quality for raw water, treated water and water in distribution reservoir at major eight drinking water treatment plants (DWTPs) in Korea. By analyzing secondary contamination of tap water, the variation of secondary contaminants was investigated with regard to pipe materials, aging and corrosion index (CI). In addition, we suggested an appropriate CI applicable water quality and the management plan for CI monitoriing. All CI showed corrosive water quality, and they did not change significantly in the distribution network. However, Copper (Cu), iron (Fe) and zinc (Zn) concentrations as secondary contaminants increased through the distribution network. Among CI, LI was most sensitive to changes in raw water quality and drinking water treatment. Also, it has high correlations with other indexes such as RSI, AI. Therefore, LI is considered as an appropriate CI to the domestic water quality. Based on these result, we propose LI as a drinking water quality standard to control the pipe corrosion from DWTPs.

A study on the application of water safety plans for the hazard risk management of tap water (수돗물 위해요소 리스크 관리를 위한 물안전계획 적용 연구)

  • Kim, Jinkeun;Kim, Dooil
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.4
    • /
    • pp.259-268
    • /
    • 2019
  • One of the most effective methods to consistently ensure the safety of a tap water supply can be achieved by application of a comprehensive risk assessment and risk management approach for drinking water supply systems. This approach can be termed water safety plans(WSP) which recommended by WHO(world health organization) and IWA(international water association). For the introduction of WSP into Korea, 150 hazards were identified all steps in drinking water supply from catchment to consumer and risk assessment tool based on frequency and consequence of hazards were developed. Then, developed risk assessment tool by this research was implemented at a water treatment plant($Q=25,000m^3/d$) to verify its applicability, and several amendments were recommended; classification of water source should be changed from groundwater to stream to strengthen water quality monitoring contaminants and frequencies; installation of aquarium to monitor intrusion of toxic substances into raw water; relocation or new installation on-line water quality analyzers for efficient water quality monitoring; change of chlorination chemical from solid phase($Ca(OCl)_2$) to liquid phase(NaOCl) to improve soundness of chlorination. It was also meaningful to propose hazards and risk assessment tool appropriate for Korea drinking water supply systems through this research which has been inconsistent among water treatment authorities.

The Assessment of Water Supply Issues in Metro Manila (마닐라 광역시 물공급 이슈(Issues) 진단)

  • Rubio, Christabel Jane;Kim, Lee Hyung;Jeong, Sang Man
    • Journal of Wetlands Research
    • /
    • v.10 no.3
    • /
    • pp.37-45
    • /
    • 2008
  • The Philippine government enacted the National Water Crisis Act in 1995, as a response to the burgeoning situation of water supply systems in the country. This act led to the privatization of Metropolitan Waterworks and Sewerage System (MWSS), sector having jurisdiction and control over all waterworks and sewerage systems in a service area including Metro Manila. Nowadays, the region's supply of water is still facing a lot of difficulties, both in quality and quantity. The unabated migration of people to the metro which increases its population, tapping from the aged pipelines, lack of water facilities and infrastructure, excessive groundwater withdrawal, environmental degradation, and surface and groundwater pollution are some of the issues that Metro Manila have to deal with. These situations lead to two primary water supply issues suffered by Metro Manila: water shortage and flooding. The purpose of this paper was to present water supply in Metro Manila with respect to the problems in its distribution, environmental implications and quality. In this paper, several technical reports, published literature, and news articles were consulted and became the major basis for identifying gaps and suggesting remedial measures.

  • PDF

Research of Corrosion Growth Degree According in Liquid Environment of Waterworks and Sewer Piping Material (상·하수 배관재의 수 환경에서 부식진전도 연구)

  • Park, Kyeong-Dong;Ki, Woo-Tae;Yu, Hyeong-Ju;Kim, Dong-Uk
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.5 no.4
    • /
    • pp.33-40
    • /
    • 2006
  • The quality of the supply water which is supplied to consumer is not the thing of water after filtrating but the thing of water from faucet through pipe. As a result, heavy metals and microorganism, that is the major materials, which cause the distrust of the supply water is generated by supply process. Especially, the heavy metal is generated by the corrosion of waterworks. Besides, rupture by corrosion of pipe becomes the factor of supply water's pollution in waterworks and the factor of pollution of the soil and environment in drain pipe. Therefore, this research examined the weight reduction electric potential measure to measure the corrosion degree of piping materials after testing the corrosion of piping materials(Copper Pipe, Galvanized Steel Pipe, Stainless Steel Pipe) which is generally used at the moment in various corrosion environments(subterranean water, supply water, 3.5% NaCl, 3.5% $HNO_3$). And let me show basic design data about problem occurrence such as leakage water, rust water, inside and outside corrosion from this.

  • PDF

Mini PC control system for BYG type water supply units (BYG형 급수기의 MINI PC 제어 시스템)

  • 박용규;강영모
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10a
    • /
    • pp.1167-1171
    • /
    • 1993
  • A highly efficient hydropneumatic water supply system type BGY is designed and built in accordance with ISO standard. The technical features of BYG type pump unit can be summarized as follows: - reduce hydropneumatic tank capacity at the ratio of 1/10 - 1/30 compared with conventional method. - ISO standard pumps can be used. - the development of highly efficient water supply system type BYG is based on long-term experiences with the proven constant pressure water supply technique which minimize pressure fluctuation, rapid pilsation, etc. The text contains the operation principle of BYG type water supply system, introduction of closed cycle control process focused on Mini PC and experimental results of type BYG-IVS-90x45.

  • PDF

FTA Modeling of Water Supply System for Hydro-power Plant (수력발전소 물 공급 설비에 대한 FTA 모형)

  • Jeon, Tae-Bo;Kwon, Chang-Seob
    • Journal of Industrial Technology
    • /
    • v.26 no.B
    • /
    • pp.145-155
    • /
    • 2006
  • High level of reliability in facility operation is specifically required these days. The goal of this study is to secure a methodology for reliability analysis of hydro-power plant so that an appropriate decision for operation and investment can be made. Fault tree analysis of water supply system within hydro-power plant has been performed in this study. We briefly examined the electric power generation facility and water supply system. We then developed fault tree for the water supply system based on failure modes and effects analysis. We conclude this study and provided future research areas.

  • PDF

A Study on the Effective Operation of Bonpo Photovoltaic Power System (본포취수장 태양광발전설비의 효과적 운영방법에 관한 연구)

  • Cho, Nam-Bin;Lee, Jae-Oh;Choi, Jang-Geon;Lee, Jae-Hoon;Choi, Yeon-Han
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1124-1125
    • /
    • 2008
  • 본 연구는 한국수자원공사에서 국제기후변화협약 등 정부의 신재생에너지 개발계획에 적극 동참하고, 우리공사에서 운영관리하고 있는 수자원시설물의 잠재에너지를 발굴하기 위하여 경남지역본부 본포취수장에 설치하여 운영관리중인 시설용량 99kWp의 태양광발전설비에 대한 주요 설비와 운영관리를 하는데 불편한 사항에 대한 개선내용을 소개함으로써 향후 우리시스템과 유사한 조건(무인사업장)에 시설하여 운영할 설비를 효과적으로 관리하기 위한 내용을 소개하고 있다.

  • PDF

A Study on the Rational Planning of Water Supply and Sewage System for Rural Village Development Projects (농촌마을종합개발사업에서 상하수도시설의 합리적 계획방향에 관한 기초적 연구)

  • Kim, Hwan-Yong
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.8 no.2
    • /
    • pp.62-71
    • /
    • 2006
  • This study on the rational planning of water supply and sewage system for rural village development projects. Present, when establishment and standard about maintenance of water supply and sewage system were not presented in rural village synthesis development projects, it is real condition that service industry is depending on presenting simple plan in basis planning phase and business enforcement step. This study wishes to present basic data so that can be planned more rationally and enforce and contribute in rural village synthesis development projects water supply and sewage system that is enforced as part of rural village synthesis development projects.

  • PDF

The Effects of Hot Water Supply Temperature on Indoor Thermal Characteristics for Floor Radiant Heating System (바닥복사 난방시스템의 공급온수온도가 실내 열환경에 미치는 영향)

  • Ahn, Byung-Cheon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.14 no.4
    • /
    • pp.13-19
    • /
    • 2018
  • The Effects of hot water supply temperature on indoor thermal characteristics for floor radiant heating system in residential apartment were researched by computer simulation. The parametric study on hot water supply temperatures with different outdoor air temperatures was done with regard to energy performance and control characteristics, respectively. As a result, the maximum overshoot of indoor air temperature and energy consumption were reduced by adjusting the hot water supply temperatures with outdoor air temperatures.

Water Yield Evaluation of a Reservoir System Based on a Deficit Supply in the Han River Basin (부족분 공급방식의 한강수계 저수지 시스템 용수공급능력 평가)

  • Choi, Youngje;Lee, Eunkyung;Ji, Jungwon;Yi, Jaeeung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.40 no.5
    • /
    • pp.477-484
    • /
    • 2020
  • Reservoir operation affects the sustainability of a water supply. However, the increase in the temporal and spatial variability of rainfall, attributed to climate change, has led to severe droughts and increased difficulty in maintaining a sustainable discharge at certain locations in a reservoir system operation. In this study, water yield was evaluated using reservoir simulation with varied water supply. Three reservoir system models were simulated for nine reservoirs in the Han River basin. The time-based reliability, volumetric reliability, and resiliency were used to evaluate the results. Each case was simulated by applying firm supply, deficit supply, and deficit supply with historical power release of the Hwacheon Reservoir. As a result of the simulation, all indexes were increased when the deficit supply was applied. In particular, the time-based reliability increased by more than 30%, and the supply reliability increased by about 4%. The result showed that the water supply of the entire water system could be increased when all reservoirs in the water system were operated to supply water and maintain sustainable discharge at the same downstream point. The deficit supply was an efficient reservoir operation method for responding to climate change, especially increased rainfall variability.