• Title/Summary/Keyword: Water use

Search Result 8,291, Processing Time 0.032 seconds

Simulation on the Heating Performance of a 2-Stage Compression Heat Pump System Using River Water (하천수열원을 이용한 2단압축 열펌프의 난방성능 시뮬레이션)

  • Park Chasik;Kim Bohyun;Kim Yongchan;Lee Young Soo;Bang Ki-young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.11
    • /
    • pp.1005-1013
    • /
    • 2005
  • The use of river water as a heat source of a heat pump has the advantage in the performance compared to the use of atmospheric air because the temperature variation of river water over the year is relatively small. In this study, the performance of the heat pump system using river water as a heat source was numerically investigated. A simulation model for the 2-stage compression heat pump system was developed with each component model composed of compressors, heat exchangers, a flash tank and electronic expansion devices. The peformance of the heat pump system using river water was improved by $50\%$ compared to that using atmospheric air in winter conditions.

Evaluation of Stored Rainwater Quality at Galmoe Middle School Rainwater Harvesting System (갈뫼중학교 빗물이용시설에서의 저장 빗물수질평가)

  • Han, Moo-Young;Lee, Soon-Jai
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.1
    • /
    • pp.31-37
    • /
    • 2005
  • One of the major obstacles confronted in promoting the rainwater harvesting is the concerns of acid rain and heavy metals. Although there are many data concerning the quality of rainwater precipitation for the study of acid rain, the study on the quality of stored rainwater has been limited. In this study, we monitored the quality of stored rainwater at Galmoe middle school, where a rainwater harvesting system is installed and in use for more than two years. We measured water quality parameters such as pH, Electro Conductivity(EC), Dissolved Oxygen(DO), and some metals (aluminium (Al), chromium(Cr), manganese(Mn), zinc(Zn), copper(Cu), arsenic(As), cadmium(Cd), lead(Pb)). The monitoring period was during one year from September 9th 2003 to August 5th 2004. It was observed that the average pH of stored rainwater is neutral. DO is similar to tap water and EC is lower than tap water. Metal Concentrations are within the concentration specified in Drinking Water Quality Standard. Overall, the stored rainwater quality is good enough for sundry use and there's no threat of acid rain and air pollution, if the rainwater harvesting system is well designed and maintained.

Mix Design for Pervious Recycled Aggregate Concrete

  • Sriravindrarajah, Rasiah;Wang, Neo Derek Huai;Ervin, Lai Jian Wen
    • International Journal of Concrete Structures and Materials
    • /
    • v.6 no.4
    • /
    • pp.239-246
    • /
    • 2012
  • Pervious concrete is a tailored-property concrete with high water permeability which allow the passage of water to flow through easily through the existing interconnected large pore structure. This paper reports the results of an experimental investigation into the development of pervious concrete with reduced cement content and recycled concrete aggregate for sustainable permeable pavement construction. High fineness ground granulated blast furnace slag was used to replace up to 70 % cement by weight. The properties of the pervious concrete were evaluated by determining the compressive strength at 7 and 28 days, void content and water permeability under falling head. The compressive strength of pervious concrete increased with a reduction in the maximum aggregate size from 20 to 13 mm. The relationship between 28-day compressive strength and porosity for pervious concrete was adversely affected by the use of recycled concrete aggregate instead of natural aggregate. However, the binder materials type, age, aggregate size and test specimen shape had marginal effect on the strength-porosity relationship. The results also showed that the water permeability of pervious concrete is primarily influenced by the porosity and not affected by the use of recycled concrete aggregate in place of natural aggregate. The empirical inter-relationships developed among porosity, compressive strength and water permeability could be used in the mix design of pervious concrete with either natural or recycled concrete aggregates to meet the specification requirements of compressive strength and water permeability.

A Study on Use and improvement of Construction type infiltration gallery (조립식 집수암거의 개량과 이용에 관한 연구)

  • 함준호
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.14 no.2
    • /
    • pp.2593-2602
    • /
    • 1972
  • Plastic pipes Wrapped with synthetic filter are recently used for drainage or Collecting of Underground water. But it's use is possible only for small size of diameter less than 300mm, because large size plastic pipes are not readily availabe. For large diameter infiltration gallery, porous concrete pipes are now used, but it's heavy weight brings difficulties in making, moving and setting of the pipes. With it's conventional method of filter setting, fine sands are brought into the pipes to make trouble to lifting pumps and channels Therefore, initial construction cost and maintenance cost become high. To solve-this problem, new method is developed and tested. Small PVC pipes(diameter 14mm) are assembled at the site of construction to newly devised I beam type circls. The size of circular inpiltration gallery is optionally determined by I beam type circle which support small PVC pipes and is made of PVC amterial. This gallery are wrappd with syntheitc filter to prevent sand instruction. In this test, the diameter of 300, 400, 500mm were used. I beam type circles were made with PVC plated with thickness. t=6, 9, 12mm. Water quantity collected through the PVC circulor gallery are measured and the strengths of the gallery. 1. Allowable setting depth of gallery pipe below graund for the case of t=6mm, D=500mm is 2.72m. 2. Collected water quantity depends on soil texture, depth of water grandient of water surface, filter material angle of setting etc. 3. About 126% of water quantity collected from the one gallery pipe measured in two gallery pipes of two parallel installation.

  • PDF

Sustainability Evaluation of Western Nakdong River Basin by the Systems Ecology (시스템 생태학적 접근법에 의한 서낙동강 유역의 지속성 평가)

  • Kim, Jin Lee;Park, Bae Kyung;Lee, Su Woong;Rhew, Doug Hee
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.3
    • /
    • pp.439-445
    • /
    • 2010
  • An emergy analysis of the main energy flows driving the economy of humans and life support systems consists of environmental energies, fuels, and imports, all expressed as solar emjoules. Total emergy use (371 E20 sej/yr) of the Western Nakdong River Basin is 97 per cent from imported sources, fuels and goods and services. Emergy flows from the environment such as rain and geological uplift flux accounted for only 2.9 percent of total emergy use. Emergy yield ratio and environment loading ratio were 1.03 and 33.27, respectively. Emergy sustainability index, a ratio of emergy yield ratio to environment loading ratio, is therefore less than one, which is indicative of highly developed consumer oriented economies. It is necessary for an efficient management of Western Nakdong River Basin to reduce pollution load basically and to restructure economic activities into an environmental friendly industrial structure depending on renewable energy and resources.

Performance evaluation of sea water heat exchanger installed in the submerged bottom-structure of floating architecture

  • Sim, Young-Hoon;Hwang, Kwang-Il
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.10
    • /
    • pp.1062-1067
    • /
    • 2015
  • Floating architecture is a type of building that is geographically located on a sea or a river. It floats under the influence of buoyancy, and does not have an engine for moving it. Korea is a peninsula surrounded by sea except on the north side, so floating architectures have been mainly focused on two points: solving the issue of small territory and providing various leisure & cultural spaces. Floating architectures are expected to save energy effectively, if they use sea water heat, which is known to be clean energy with infinite reserves. To use sea water heat as the heat source and/or heat sink, this study proposes a model in which a sea water heat exchanger is embedded in the concrete structure in the lower part of the floating architecture that is submerged under the sea. Based on the results of performance evaluations of the sea water heat exchanger using CFD (computational fluid dynamics) analysis and mock-up experiments under various conditions, it is found out that the temperature difference between the inlet and outlet of the heat exchanger is in the range of $3.06{\sim}9.57^{\circ}C$, and that the quantity of heat transfer measured is in the range of 3,812~7,180 W. The CFD evaluation results shows a difference of 5% with respect to the results of mock-up experiment.

A Study on the Prediction of Daily Urban Water Demand with Multiple Regression Model (회귀모형에 의한 상수도 1일 급수량 예측에 관한 연구)

  • 박성천;문병석;오창주;이병조
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.40 no.1
    • /
    • pp.68-77
    • /
    • 1998
  • The purpose of this paper is to establish a method estimating the daily urban water demand using statistical analysis that is used for developing the efficient management and operation of the water supply facilities, and accurary of the model is verified by error rate and F-value. The data used in this study were the daily urban water use, the weather conditions such as temperature, precipitation, relative humidity, etc, and the day of The week. The case study was taken placed for the city of Namwon in Korea. The raw data used in this study were rearranged either by month or by season for analysis purpose, and the statistical analysis was applied to the data to obtain the regression model As a result of this study, the linear regression model was developed to estimate the daily urban water use with weather condition. The regression constant and coefficients of the model were determined for each month of a year. The accuracy of the model was within 3% of average error and within 11% of maximum error. The resulting model was found to he useful to the practical operation and management of the water supply facilities.

  • PDF

Hydrogen Production by the Photocatalystic Effects in the Microwave Water Plasma

  • Jang, Soo-Ouk;Kim, Dae-Woon;Koo, Min;Yoo, Hyun-Jong;Lee, Bong-Ju;Kwon, Seung-Ku;Jung, Yong-Ho
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.284-284
    • /
    • 2010
  • Currently, hydrogen has been produced by Steam Reforming or partial oxidation reforming processes mainly from oil, coal, and natural gas and results in the production of $CO_2$. However, these are influenced greatly on the green house effect of the earth. so it is important to find the new way to produce hydrogen utilizing water without producing any environmentally harmful by-products. In our research, we use microwave water plasma and photocatalyst to improve dissociation rate of water. At low pressure plasma, electron have high energy but density is low, so temperature of reactor is low. This may cause of recombination in the generated hydrogen and oxygen from splitting water. If it want to high dissociation rate of water, it is necessary to control of recombination of the hydrogen and oxygen using photocatalyst. We utilize the photocatalytic material($TiO_2$, ZnO) coated plasma reactor to use UV in the plasma. The quantity of hydrogen generated was measured by a Residual Gas Analyzer.

  • PDF

Non-invasive acceleration-based methodology for damage detection and assessment of water distribution system

  • Shinozuka, Masanobu;Chou, Pai H.;Kim, Sehwan;Kim, Hong Rok;Karmakar, Debasis;Fei, Lu
    • Smart Structures and Systems
    • /
    • v.6 no.5_6
    • /
    • pp.545-559
    • /
    • 2010
  • This paper presents the results of a pilot study and verification of a concept of a novel methodology for damage detection and assessment of water distribution system. The unique feature of the proposed noninvasive methodology is the use of accelerometers installed on the pipe surface, instead of pressure sensors that are traditionally installed invasively. Experimental observations show that a sharp change in pressure is always accompanied by a sharp change of pipe surface acceleration at the corresponding locations along the pipe length. Therefore, water pressure-monitoring can be transformed into acceleration-monitoring of the pipe surface. The latter is a significantly more economical alternative due to the use of less expensive sensors such as MEMS (Micro-Electro-Mechanical Systems) or other acceleration sensors. In this scenario, monitoring is made for Maximum Pipe Acceleration Gradient (MPAG) rather than Maximum Water Head Gradient (MWHG). This paper presents the results of a small-scale laboratory experiment that serves as the proof of concept of the proposed technology. The ultimate goal of this study is to improve upon the existing SCADA (Supervisory Control And Data Acquisition) by integrating the proposed non-invasive monitoring techniques to ultimately develop the next generation SCADA system for water distribution systems.

Water Supply and Samurai Residence in the Castle Towns during the Edo Period: The Creation of the Modern Urban Dwellers

  • Satoshi, Fujimura
    • Journal of East-Asian Urban History
    • /
    • v.3 no.1
    • /
    • pp.83-120
    • /
    • 2021
  • This article analyzes the publicness of early modern cities and the character of samurai residences as urban dwellers through the water supply and use of the Edo period in Japan. Firstly, in Edo, a megacity with a population of about one million, the Shogunate organized samurai residences (mainly those of feudal lords, Daimyo) into geographical organizations, and samurai residences paid for the repair of water facility and the water fee, just the same as the townspeople. Next, in Fukui (provincial castle town), samurai residence (Daimyo's vassal) organization for waterway didn't exist. The samurai residences were relieved of the burden of maintaining the waterways due to poverty. And, before the later Edo period, samurai vassals were not punished for violating the rules on water use, but they were eventually included in the punishment. The gap in feudal status between samurai and townspeople narrowed. It was a process of creating a modern urban society composed of equal dwellers. Although Edo and Fukui belonged to the same category as castle towns, the urban publicness and the position of samurai residences were different due to their dissimilar political positions as the Shogunate capital city and the Daimyo's provincial castle town.