• Title/Summary/Keyword: Water treatment facility

Search Result 302, Processing Time 0.025 seconds

Analysing the Effect of Residual Chlorine Equalization for Water Quality Improvement in Water Distribution System (공급과정 수질개선을 위한 잔류염소 균등화 효과분석)

  • Choi, Taeho;Lee, Doojin;Bae, Cheolho;Moon, Jiyoung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.5
    • /
    • pp.587-596
    • /
    • 2016
  • This study attempts to draw factors for an analysis of the operation effect of a rechlorination facility and autodrain equipment for residual chlorine equalization by installing and operating a rechlorination facility and autodrain equipment in P City and analyzing the practical evaluation method and operation effect. For this purpose, this study selected three indicators for an analysis of the effectiveness of residual chlorine equalization and conducted a comparative analysis before and after the implementation of the residual chlorine equalization. As a result of estimation, (1) the reduction of the residual chlorine concentration range from a water treatment plant to the pipe end was 16.0%; (2) the total reduction of chlorination input was 18.0%; and (3) the reduction of the generation of disinfection by-products was 19.5%. In addition, this achieved enough residual chlorine equalization in the supply process and shows that it could successfully achieve the economic feasibility of investment in equipment and the reduction of the generation of disinfection by-products. Like this, it is judged that the three indicators suggested in this study will be used sufficiently as indicators of an analysis of the effectiveness of residual chlorine equalization according to the operations of the rechlorination facility and autodrain equipment.

Status of Anaerobic Digestion Facility for Pig-slurry in Korea (국내 가축분뇨 혐기소화시설 현황 및 운영실태 분석)

  • Jeong, Kwang-Hwa;Kim, Jung-Gon;Han, Duk-Woo;Kwag, Jung-Hun
    • Journal of Animal Environmental Science
    • /
    • v.20 no.1
    • /
    • pp.27-34
    • /
    • 2014
  • This study was conducted to survey and inspect the currently operating anaerobic digestion facilities for animal manure. Recently, the number of anaerobic digestion facility for livestock manure is on the rise thanks to growing interest in developing alternative energy. A anaerobic digestion system has been constructed in large scale farms or animal manure public resource center. Currently, most animal manure anaerobic digestion facilities in operation are producing biogas from the pig slurry which contains 97% water. Methane gas can be used to operate a engine generator which then produces electricity. Anaerobic digestate, a by-product of digestion, is mostly utilized as a liquid fertilizer after curing processing. Only in a few cases, it can be discharged after wastewater treatment process. The problem of anaerobic digestate treatment is the imbalance of C/N ratio. The content of N was too high to keep it into normal process.

Application of peak load for industrial water treatment plant design (공업용수 정수장 설계시 첨두부하 적용방안)

  • Kim, Jinkeun;Lee, Heenam;Kim, Dooil;Koo, Jayong;Hyun, Inhwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.3
    • /
    • pp.225-231
    • /
    • 2016
  • Peak load rate(i.e., maximum daily flow/average daily flow) has not been considered for industrial water demand planning in Korea to date, while area unit method based on average daily flow has been applied to decide capacity of industrial water treatment plants(WTPs). Designers of industrial WTPs has assumed that peak load would not exist if operation rate of factories in industrial sites were close to 100%. However, peak load rates were calculated as 1.10~2.53 based on daily water flow from 2009 to 2014 for 9 industrial WTPs which have been operated more than 9 years(9-38 years). Furthermore, average operation rates of 9 industrial WTPs was less than 70% which means current area unit method has tendency to overestimate water demand. Therefore, it is not reasonable to consider peak load for the calculation of water demand under current area unit method application to prevent overestimation. However, for the precise future industrial water demand calculation more precise data gathering for average daily flow and consideration of peak load rate are recommended.

Water Treatment Process for Removal of Free Ammonia in Bank Filtrated Water (암모니아성 질소제거를 위한 강변여과수에서의 수처리 공정)

  • Choo Tae-Ho;Lee Jung-Suk
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2005.11a
    • /
    • pp.123-128
    • /
    • 2005
  • Buk-myeon area in Changwon is located near Nakdong river and not short of quantity of river but the water quality and quantity is changed extremely by seasons, and Fe, Mn, Cu are found at the base rock underground water. Therefore, bank filtrated water developing is settled. At this research, Pilot-Plant is built to find out Fe and Mn are detected and eliminated by biological process and the ammonia is exceeded the drinking water quality criteria at the bank filtrated water while designing and facilitating the local water supply facilities at Buk-myeon area. Also, check results of the changed treatment process of automatic precipitating filter, which is producing and supplying drinking water, and analyzing the Biological Process Effectiveness by building and running Buk-myeon Water Treatment Facility, which could provide $10,000m^3/day$.

  • PDF

The Allocation Methods for Economical Efficiency Using an Optimized Model (최적화 모델을 이용한 경제적인 총량관리 할당기법 연구)

  • Choi, In Uk;Shin, Dong Seok;Kim, Hong Tae;Park, Jae Hong;Ahn, Ki Hong;Kim, Yong Seok
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.3
    • /
    • pp.295-303
    • /
    • 2015
  • In Korea, Total Maximum Daily Loads(TMDLs) has been enforced to restore and manage water quality in the watersheds. However, some assesment of implementation plan of TMDLs showed that the achievement of the target water quality is not related to the proper allocation loads because difference of flow duration interval. In the United States, the discharge loads are determined by water quality modeling considering standard flow conditions according to purpose. Therefore, this study tried to develop the allocation method considering economical efficiency using water quality model. For this purpose, several allocation methods being used in the management of TMDLs is investigated and develope an allocation criteria considering regional equality and uniformity. Since WARMF(Watershed Analysis Risk Management Framework) model can simulate the time varying behavior of a system and the various water quality variables, it was selected for a decision support system in this study. This model showed fairly good performance by adequately simulating observed discharge and water quality in Miho watershed. Furthermore, the scenario simulation results showed that the effect of annual average water quality improvement to remove 1kg BOD is more than 25 times, even if point pollutants treatment facility is six times more expensive to operate than non-point pollutants treatment facility.

A Study on the Nitrogen Control in the Treated Leachate water by Bio-film Module System (생물막을 이용한 침출수처리수 중의 질소제어에 관한 연구)

  • 최규철;이규성;정일현
    • Journal of environmental and Sanitary engineering
    • /
    • v.11 no.1
    • /
    • pp.71-76
    • /
    • 1996
  • Bio-film module system was applied to the treated leachate water that priorly had been treated with biological nitrification process. The experiments were performed in the laboratory and treated leachate water treatment facility. Experimental results obtained from laboratory conditions and nitrogen removal efficiencies were averaged 90% for 1 hr.

  • PDF

Control and Development of LonWorks Intelligent Control Module for Water Treatment Facility Based Networked control System

  • Hong, Won-Pyo;Kim, Dong-Hwa
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1757-1762
    • /
    • 2003
  • With distribution industrial control system, the use of low cost to achieve a highly reliable and safe system in real time distributed embedded application is proposed. This developed intelligent node is based on two microcontrollers, one for the execution of the application code, also as master controller for ensuring the real time control & the logic operation with PLD and other for communication task and the easy control execution, i.e., I/O digital input, digital output and interrupting. This paper also presents where the case NCS (Networked control system) with LonTalk protocol is applied for the filtration process control system of a small water treatment plant.

  • PDF

Application Technology Development of Lon Works Fieldbus Network System for Distributed Control System Based Water Treatment Facility

  • Hong, Won-Pyo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.404-411
    • /
    • 2004
  • With distribution industrial control system, the use of low cost to achieve a highly reliable and safe system in real time distributed embedded application is proposed. This developed intelligent node is based on two microcontrollers, one for the execution of the application code, also as master controller for ensuring the real time control & the logic operation with CPLD and other for communication task and the easy control execution, i.e., I/O digital input, digital output and interrupting. This paper also presents where the case NCS (Networked control system) with LonTalk protocol is applied for the filtration process control system of a small water treatment plant.

  • PDF

Development of Intelligent Control Module with ANSI/EIA 709.1 for Water Treatment Facility

  • Hong, Won-Pyo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.243-249
    • /
    • 2003
  • With distribution industrial control system, the use of tow cost to achieve a highly reliable and safe system in real time distributed embedded application is proposed. This developed intelligent node is based on two microcontrollers, one for the execution of the application code, also as master controller for ensuring the real time control & the logic operation with PLD and other for communication task and the easy control execution, i.e., I/O digital input, digital output and interrupting. This paper also presents where the case NCS(Networked control system) with LonTalk protocol is applied for the filtration process control system of a small water treatment plant.

  • PDF

Development of Water Treatment System Using Non-contact Plasma (비접촉식 플라즈마 수처리 장치(플라투스) 개발)

  • Lee, Min-ki;Jeong, Byung-jo;Park, Jun-hyung;Jo, Gil-hwoan
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.117-119
    • /
    • 2012
  • Plasma Water Treatment, a Unique System(PLATUS) of algae(Chl-a) removal efficiency is average 90.6 up to 99.6%, It is cost effective facility because it doesn't need any other chemicals and consumables. Also, It is Eco-friendly installation with no sludge. It is easy to transform its treatment capacity by the number of Plasma installation. As it requires small space for installing, It can be installed in Land nearby water, vehicle mounted, and set on the ship.

  • PDF