• Title/Summary/Keyword: Water transmission system

Search Result 279, Processing Time 0.028 seconds

Android Remote Monitoring System of Ballast Water Treatment System (선박 평형수 처리 시스템의 안드로이드 원격 모니터링 시스템)

  • Choi, Hwi-Min;Seo, Ji-No;Lee, Kwang-Seob;Kim, Seon-Jong;Kim, Joo-Man
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.6
    • /
    • pp.217-224
    • /
    • 2015
  • In this paper, I describe a system for remote monitoring of devices Android-based sensor data recorded during the operation of the ballast water treatment system. The proposed remote monitoring system is Designed and implemented when a problem occurs in the ballast water treatment system installed in the vessel, provide information if you are unable to determine the cause in the field or engineer dispatch request of external. System developed is composed of a server holding the sensor data information collected from the vessel and a mobile device that is not bound to time and place. The transmission of sensor data between mobile devices and server, and is implemented by TCP/IP to transmit information securely. System is composed of request to the server from the mobile device after the user inputs the input values, to transmit the sensor data. The device provides the information of the sensor with a high level of importance to the user. Through the remote monitoring sensor information of the ballast water treatment system, the system is made to predict the failure of the sensor.

An Optimal Conjunctive Operation of Water Transmission Systems from Multiple Sources with applying EPAnet and KModSim Model (KModSim 모형(模型)에 의한 도시지역(都市地域) 다중수원(多衆水源) 송수관망간(送水管網間) 최적(最適) 연계(連繫) 운영(運營) 연구(硏究))

  • Ryu, Tae-Sang;Cheong, Tae-Sung;Ko, Ick-Hwan;Ha, Sung-Ryong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.500-504
    • /
    • 2008
  • The objective of this paper is to evaluate the feasibility of using an optimization model as a effective way to search conjunctive operation scheme to meet two conditions; one is to minimize the electric cost for pumping and another is to meet the water demand for satisfying customers. The feasibility is confirmed as comparing the best combinations of pumps between multi-regional water supply networks from multiple sources which are obtained through an optimization modeling and EPAnet modeling. KModsim model, a network optimization model, was used to determine conjunctive operation scheme in the pipe system. KModsim, based on Lagrangian Relaxation algorithm, is useful for modeling network system and obtaining simultaneously pump combination and water allocation with given input option such as energy unit cost supplying from a source into a consumer, operating pumping combination. This study develops the procedure of determining optimal conjunctive operation scheme with using KModsim model. As a study region, the water supplying systems of the Geojae-city in the Geongsang Namdo Province was selected and investigated. The EPAnet hydraulic simulation result(Ryu et al, 2007, KSWW) gave input data for optimization model; energy unit price(won/$m^3$), water service available area etc.. It was assured that the combination of pump operation through optimum conjunctive operation is to be optimum scheme to obtain the best economic water allocation with comparison to the hydraulic simulation result such as electric cost and pump combination cases. The results obtained through the study are as follows. First, It was found that a well-allocated water supply scheme, the best combination of pump operation through optimum joint operation, promises to save the electric cost and satisfy all operational goals such as stability and revenues during the period. Second, an application of KModSim, a network model, gave the amount of water allocation from each source to a consumer with consideration of economic supply. Finally, in a service area available to supply through conjunctive operation of existing inter-regional water supply networks within short distance, a conjunctive operation is useful for determining each transmission pipeline's service area and maximizing the effectiveness of optimizations in pumping operation time.

  • PDF

Multispecies Interactions in Biofilms and Implications to Safety of Drinking Water Distribution System

  • Reuben, Rine Christopher;Roy, Pravas Chandra;Sarkar, Shovon Lal;Ha, Sang-Do;Jahid, Iqbal Kabir
    • Microbiology and Biotechnology Letters
    • /
    • v.47 no.4
    • /
    • pp.473-486
    • /
    • 2019
  • In the aquatic environment, microorganisms are predominantly organized as biofilms. Biofilms are formed by the aggregation of microbial cells and are surrounded by a matrix of extracellular polymeric substances (EPS) secreted by the microbial cells. Biofilms are attached to various surfaces, such as the living tissues, indwelling medical devices, and piping of the industrial potable water system. Biofilms formed from a single species has been extensively studied. However, there is an increased research focus on multispecies biofilms in recent years. It is important to assess the microbial mechanisms underlying the regulation of multispecies biofilm formation to determine the drinking water microbial composition. These mechanisms contribute to the predominance of the best-adapted species in an aquatic environment. This review focuses on the interactions in the multispecies biofilms, such as coaggregation, co-metabolism, cross-species protection, jamming of quorum sensing, lateral gene transfer, synergism, and antagonism. Further, this review explores the dynamics and the factors favoring biofilm formation and pathogen transmission within the drinking water distribution systems. The understanding of the physiology and biodiversity of microbial species in the biofilm may aid in the development of novel biofilm control and drinking water disinfection processes.

Analysis of Wave Transmission Characteristics on the TTP Submerged Breakwater Using a Parabolic-Type Linear Wave Deformation Model

  • Jeong, Jin-Hwan;Kim, Jin-Hoon;Lee, Jung-Lyul
    • Journal of Ocean Engineering and Technology
    • /
    • v.35 no.1
    • /
    • pp.82-90
    • /
    • 2021
  • Owing to the advantages of assuring the best views and seawater exchange, submerged breakwaters have been widely installed along the eastern coast of Korea in recent years. It significantly contributes to promoting the advancement of shorelines by partially inhibiting incident wave energy. Observations were carried out by a pressure-type wave gauge in the Bongpo Beach to evaluate the coefficients of wave transmission via a submerged breakwater, and the results obtained were compared with those of existing conventional equations on the transmission coefficient derived from hydraulic experiments. After reviewing the existing equations, we proposed a transmission coefficient equation in terms of an error function. Although it exhibited robust relationships with the crest height and breaking coefficient, deviations from the observed data were evident and considered to be triggered by the difference in the incident wave climate. Therefore, in this study, we conducted a numerical experiment to verify the influence of wave period on the coefficients of wave transmission, in which we adopted a parabolic-type mild-slope equation model. Consequently, the deviation from calculated results appears to practically cover all deviation range in the observed data. The wave period and direction of the incident wave increased, the transmission coefficient decreased, and the wave direction was determined to demonstrate a relatively significant influence on the transmission coefficient. It was inferred that this numerical study is expected to be used practically in evaluating the design achievement of the submerged breakwater, which is adopted as a countermeasure to coastal beach erosion.

Experimental Study on Energy Transmission Rate of Horizontal Dual Plate by Random Wave System (수평형(水平型) 이열(二列) 조합판(組合板)의 투과율(透過率) 산정(算定)을 위한 실험적(實驗的) 연구(硏究))

  • Kweon, Hyuck-Min;Kim, Young-Hak;Kee, Sung Tae
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.4B
    • /
    • pp.421-428
    • /
    • 2008
  • For last decades, the rapid coastal erosion process spreading along Korean peninsular has become a nuisance especially for tourism and local economy. Global warming and sea-level rise demand persistently new coastal protection strategies against the conventional methods using armored structures. In a view of this, Kweon et al. (2007) has proposed a new type of horizontal steel plates for an ideal candidate as eco-friendly detached breakwater systems for global warming era. The breakwater is composed of piles and horizontal porous plates that was devised for the optimized blockage effects and wave energy dissipations. This system provides outstanding performances as wave barrier and added advantages such as a rapid installation, an easy relocation, a perfect water circulation for the stagnation of pollutions in sheltered regions. The present experimental study focuses on the performance evaluations of the proposed system in wind wave conditions as a wave dissipator and reflector. The reflection, transmission, and energy dissipation of the random waves has been discussed in detail based on a newly proposed relation between wave steepness and a plate width normalized by wave length that are major factors affecting the wave transmission.

The Implementation of a Real-time Underwater Acoustic Communication System at Shallow water (천해역에서의 실시간 수중 데이터 통신 시스템 구현)

  • Baek, Hyuk;Park, Jong-Won;Lim, Yong-Kon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.06a
    • /
    • pp.754-757
    • /
    • 2007
  • In this paper, we present an implementation and it's real-sea test of an underwater acoustic data communication system, which allows the system to reduce complexity and increase robustness in time variant underwater environments. For easy adaptation to complicated and time-varying environments of the ocean, all-digital transmitter and receiver systems were implemented. For frame synchronization the CAZAC sequence was used, and QPSK modulation/ demodulation method with carrier frequency of 25kHz and a bandwidth of 5kHz were applied to generate 10kbps transmission rate including overhead. To improve transmission quality, we used several techniques and algorithms such as adaptive beamforming, adaptive equalizer, and convolution coding/Viterbi decoding. for the verification of the system performance, measurement of BER has been done in a very shallow water with depth of 8m at JangMok, Geoje. During the experiment, image data were successfully transmitted up to about 7.4km.

  • PDF

Feasibility Study on the Conjunctive Operation of Water Transmission Systems from Multiple Source with Applying EPAnet (수리해석(水理解析) 모형(模型)을 이용한 다수원(多水源) 송수계통(送水系統)의 연계(連繫) 운영(運營) 방안(方案) 경제성(經濟性) 평가(評價) - 거제시(市)를 대상(對象)으로 -)

  • Ryu, Tae-Sang;Ha, Sung-Ryong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.5
    • /
    • pp.609-619
    • /
    • 2007
  • The objective of this paper is to evaluate the feasibility of conjunctive Operation between Multi-regional water supply networks from multiple source as a effective way to meet two conditions: to minimize the electric cost for providing water demanded and meet the water flow rate for satisfying customers. EPAnet Model is used to calculate a hydraulic water distribution condition based on an integrated operation of water supply systems located in short distance. The modeling was conducted on several simulation cases including the individual operation by existing inter-regional water supply networks within short distance, the conjunctive operation of more than two existing networks with valve fully closed and full open constraint. As a study distribution system, water supplying systems of the Geojae-city in the Geongsang Namdo Province was selected and investigated. It was found that a well-allocated water supply scheme based on a conjunctive operation promises to save the electric cost and satisfy all operational goals such as stability and revenues during the period. The result such as unit district costs, pareto optimum pump combination sets will be applied to the optimization for a conjunctive operation of existing inter-regional water supply networks within short distance.

Optimal Operation by integrating Sihwa Power into NamSihwa Systems (시화조력발전 연계에 의한 남시화 계통의 최적 운영 방안)

  • Kim, Kyu-Ho;Song, Kyung-Bin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.5
    • /
    • pp.120-126
    • /
    • 2009
  • This paper presents an optimal operating scheme by integrating Sihwa tidal power into NamSihwa systems. For optimal operation of NamSihwa systems, the sea levels of 1 minute interval using cubic interpolation based on the forecasted levels of high and low water are calculated. Especially, it is compared by three schemes to purchase total power from transmission system to purchase total power from tidal power system in time period that can generate tidal power and to purchase total power by comparing purchase costs from transmission system and tidal power system. The scheme may contribute to energy save in Korea that natural resources are lacking.

Real-time measurement management system UI development linked the Water treatment facilities Broadband Convergence Network (수처리시설용 광대역 통합망 연계형 실시간 계측 관리 시스템 UI개발)

  • Yang, Seungyoun;Kim, Jintae;Oh, Hwanjin;Lee, Minwoo
    • Journal of Satellite, Information and Communications
    • /
    • v.10 no.4
    • /
    • pp.83-86
    • /
    • 2015
  • In this paper, we propose a real-tim measurement management system UI development linked the Water treatment facilities broadband Convergence Network. The sensor and the image data received by the server develop a program to interact with Web through water treatment facilities broadband convergence network. So, Separately develop UI capable of independently operating. Building a web server for remote monitoring of the transmission sensor and the image data. And Monitoring and control is possible the sensor data and image data through the Web-based UI. We can grasp the current state such as measurement time, concentration and depth of interface through the proposed real-time measurement management system UI development liked the water treatment facilities broadband convergence network. So, we can check in whether the normal operation of water treatment facilities and whether the casualties such as fire and security. As well as real time to see the information at a glance due to UI development can be raal-time monitoring of real-time measurement management system.

NIRS Analysis of Liquid and Dry Ewe Milk

  • Nunez-Sanchez, Nieves;Varo, Garrido;Serradilla-Manrique, Juan M.;Ares-Cea, Jose L.
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1251-1251
    • /
    • 2001
  • The routine analysis of milk chemical components is of major importance both for the management of animals in dairy farms and for quality control in dairy industries. NIRS technology is an analytical technique which greatly simplifies this routine. One of the most critical aspects in NIRS analysis of milk is sample preparation and analysis modes which should be fast and straightforward. An important difficulty when obtaining NIR spectra of milk is the high water content (80 to 90%) of this product, since water absorbs most of the infrared radiation, and, therefore, limits the accuracy of calibrating for other constituents. To avoid this problem, the DESIR system was set up. Other ways of radiation-sample interaction adapted for liquids or semi-liquids exist, which are practically instantaneous and with limited or null necessity of sample preparation: Transmission and Folded Transmission or Transflectance. The objective of the present work is to compare the precision and accuracy of milk calibration equations in two analysis modes: Reflectance (dry milk) and Folded Transmission (liquid milk). A FOSS-NIR Systems 6500 I spectrophotometer (400-2500 nm) provided with a spinning module was used. Two NIR spectroscopic methods for milk analysis were compared: a) folded transmission: liquid milk samples in a 0.1 pathlength sample cell (ref. IH-0345) and b) reflectance: dried milk samples in glass fibre filters placed in a standard ring cell. A set of 101 milk samples was used to develop the calibration equations, for the two NIR analysis modes, to predict casein, protein, fat and dry matter contents, and 48 milk samples to predict Somatic Cell Count (SCC). The calibrations obtained for protein, fat and dry matter have an excellent quantitative prediction power, since they present $r^2$ values higher than 0.9. The $r^2$ values are slightly lower for casein and SCC (0.88 and 0.89 respectively), but they still are sufficiently high. The accuracy of casein, protein and SCC equations is not affected by the analysis modes, since their ETVC values are very similar in reflectance and folded transmission (0.19% vs 0.21%; 0.16% vs 0.19% and 55.57% vs 53.11% respectively), Lower SECV values were obtained for the prediction of fat and dry matter with the folded transmission equations (0.14% and 0.25% respectively) compared to the results with the reflectance ones (0.43% and 0.34% respectively). In terms of accuracy and speed of analytical response, NIRS analysis of liquid milk is recommended (folded transmission), since the drying procedure takes 24 hours. However, both analysis modes offer satisfactory results.

  • PDF