• 제목/요약/키워드: Water transmission main

검색결과 38건 처리시간 0.026초

도·송수관로의 실시간 운영효율화를 위한 수압계 설치위치 선정 방안 (Pressure sensor placement method for real-time operation efficiency of water transmission mains)

  • 김성한;최두용;김경필;이상철
    • 상하수도학회지
    • /
    • 제30권5호
    • /
    • pp.491-500
    • /
    • 2016
  • Pressure monitoring is expected to be expanded in a water distribution system according to accelerated development of smart water network management technologies caused by appearances of affordable digital infrastructures like computing, storage and bandwidth. However, the placement of pressure sensors has been determined by engineer's technical decisions since there is no well-defined criteria for deciding a suitable location of pressure sensor. This study presents a placement method of pressure sensors based on the consideration of allowable error in calibrating water network analysis modeling. The proposed method is to find a minimum set of pressure sensors for achieving a reliable management of water transmissions main and increasing the efficiency of their real-time operation. In the case study in Y area's transmission main, the proposed method shows equally distributed pressure sensors in terms of hydraulics. It is expected that the proposed method can be used to manage transmission mains stably and construct a robust real-time network analysis system as a minimal criteria.

수돗물 공급 안정화를 위한 광역상수도 관로 안정화 타당성 연구 (Feasibility Study of Multi-regional Transmission Main Stabilization for Sustainable Water Supply)

  • 이재범;이충성;정관수
    • 상하수도학회지
    • /
    • 제27권3호
    • /
    • pp.395-404
    • /
    • 2013
  • The risk of pipe-bursting in multi-regional transmission mains consisting of 89 % of singled pipeline is so high that pipeline stabilization project is required such as renewal and replacement, pipe paralleling, emergency ties. Pipeline stabilization projects could be postponed at the step of initial decision-making because effect of this project is intangible benefit like activation of economic, improvement of welfare related to water. This study is to suggest quantified economical feasibility model for intangible benefit presumption to solve above problem. Cost reduction of emergency water supply, leakage, burst restore and energy efficiency improvement was altered and applied. As a result of economic analysis taking into account estimated benefit and cost under discount rate 5.5 %, service life 40 years, sufficient economic feasibility analyzed with B/C 2.45, NPV 317,700 million won, IRR 9.09 %.

이중송수관로를 이용한 안정적인 송수를 위한 설계인자에 관한 연구 (A research on the design parameters for a double-transmission main system for sustainable water supply)

  • 현인환;홍준의;김두일
    • 상하수도학회지
    • /
    • 제27권1호
    • /
    • pp.129-138
    • /
    • 2013
  • Water interruption is often caused by a rupture in the branch-like singular pipeline. This will cause critical complaints from household and may decrease public service quality. As an alternative of singular pipeline, additional parallel pipeline could be installed for sustainable water supply. This system is called double pipeline system and able to be utilized for water transmission line between treatment plant and distribution reservoir. Construction of double pipeline was thought to increase capital cost, which can be an issue to waterworks authorities. Reducing capital cost was possible by means of installing connectors between two parallel pipelines because of reduced diameter of each pipe. To obtain optimal design condition for connectors, it was necessary to compare water pressure according to accident location, to investigate flow according to connection pipe spacing, connection pipe diameter, and aging of pipe. Reliable and economical connection layouts were determined based on these results. The cost estimation for each design condition was carried out. Cost was approximately reduced by 20 ~ 30 % compared to the double pipeline without connections. In addition to this, connection between double pipelines could expect extra benefits for maintenance since the pipe could be repaired and rehabilitated without interruption.

수중정보의 원격계측시스템에 관한 연구 (A Study on the Telemetric Measuring System of the Underwater Information)

  • 신형일
    • 수산해양기술연구
    • /
    • 제24권1호
    • /
    • pp.7-11
    • /
    • 1988
  • 수산, 해양자원을 개발함에 있어 가장 중요한 요소중의 하나인 해양환경요소를 효과적으로 측정하기 위해 원격제어장치를 제작하여 수온에 대한 원격제어실험을 행한 결과, 수은온도계로 직접 측정한 측정치와 원격제어 시스템에 의한 측정치는 수온 $12^{\circ}C~37^{\circ}C$ 범위에서는 완전정상관을 이루어, 본 원격계측 시스템은 수온의 원격제어에 효과적으로 사용할 수 있음을 확인할 수 있으며, 다른 수중정보의 원격제어에도 크게 활용될 수 있으리라 생각된다.

  • PDF

Design of Micro Water Supply System Using Solar Energy

  • Sharma, Ekisha;Khatiwada, Nawa Raj;Ghimire, Anish
    • 적정기술학회지
    • /
    • 제5권1호
    • /
    • pp.8-17
    • /
    • 2019
  • Solar pumps, for water lift systems, is becoming popular in rural areas for supplying drinking water in dry seasons when its need is elevated. The development in technology has also made solar pumps readily available and cheap which has increased its demands. So, for scattered settlements having a limited budget for operation and maintenance costs, solar pump is preferred over grid connected electrical pumping systems. This primary objective of the study was to design a solar photovoltaic pumping drinking water supply system for a small health post which is about 45 km east from Kathmandu, the capital city of Nepal. The study also compared and verified the final design with the system's existing design prepared by a development agency. The water source for this study was a confined aquifer 115m below the surface. The water demand was calculated to be 11m3 per day. A 1500 kPa submersible pump attached to a motor was selected and installed. Along with that twelve solar panels, reservoir, transmission main and distribution main was designed. The outcomes conclude solar photovoltaic pumping water supply systems to be cost-effective with an estimated cost of only USD 0.84 million per MLD. Solar pumps require low maintenance and operation costs and its repairs can quickly be done by the local people. The study also shows that solar technology produces no sound, needs no fuel making it environmentally friendly.

Various Factors Influencing the Lifetime of Suspension-Type Porcelain Insulators for 154 kV Power Transmission Lines

  • Choi, In Hyuk;Park, Joon Young;Kim, Tae Gyun;Yoon, Yong Beum;Yi, Junsin
    • Transactions on Electrical and Electronic Materials
    • /
    • 제18권3호
    • /
    • pp.151-154
    • /
    • 2017
  • In this article, we investigated the various influencing factors that degraded the lifetime of suspension insulators in 154 kV transmission lines, and showed the possible solutions to avoid such breakdowns. With respect to achieve safety, reliability and aesthetical considerations, the characteristics of transmission and distribution network power cables should be improved. Suspension insulators are particularly important to study, as they have developed to be the main component of transmission lines due to their ability to withstand the electrical conductivity of high-voltage power transmission. Suspension insulators are mostly made from glass, rubber and ceramic material due to their high resistivity. In Korea, porcelain suspension insulators are typically used in the transmission line system, as they are cheaper and more flexible compared to other types of insulators. This is effective from preventing very high and steep lightening impulse voltages from causing the breakdown of suspension insulators used in power lines. Other influential factors affect the lifetime of suspension insulators that we studied include temperature, water moisture, contamination, mechanical vibration and electrical stress.

22.9kV 수용가 전력계통별 고조파 발생실태 및 관리기준 조사분석 (to examine of management standard by the harmonics measured and analyzed in 22.9kV Power lines)

  • 이은춘;신강욱;홍성택;홍영재;박영춘;임재일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.270-272
    • /
    • 2004
  • At the water supply field, high voltage induction motor is main facility of a load equipment. The motor is often out of order and its noise, generated heat, loss etc occurred occasionally. especially, transmission motor for flux control generates an amount of the harmonics then have a bad influence upon the electric power system. In this study, to analyze the total harmonics distortion of the water supply field receiving high voltage, the harmonics measured and analyzed using the PQA(Power quality Analyzer) according to the electric power system and electrical load and the reduction method presented.

  • PDF

수도사업장 고조파 측정, 분석을 통한 관리기준 만족여부 조사 (To examine of management standard by the harmonics measured and analyzed in water supply field)

  • 홍성택;이은춘;신강욱;임재일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.296-298
    • /
    • 2003
  • At the water supply field, high voltage induction motor is main facility of a load equipment. The motor is often out of order and its noise, generated heat, loss etc occured occasionally. especially, transmission motor for flux control generates an amount of the harmonics then have a bad influence upon the electric power system. In this study, to analyze the total harmonics distortion of the water supply field receiving high voltage, the harmonics measured and analyzed using the PQA(Power Quality Analyzer) according to the electric power system and electrical load and the reduction method presented.

  • PDF

수격작용(워터햄머)의 해석에 관한 연구 (Study on Waterhammer Analysis)

  • 남선우
    • 물과 미래
    • /
    • 제12권2호
    • /
    • pp.49-55
    • /
    • 1979
  • 본 연구는 관수로내의 부정류 즉 펌푸모터의 시동, 정지 및 발브 조절시에 압력관수로에 나타나는 급변류의 현상, 특히 수격작용의 해석을 Computer에 의해 자동해석하는 방법을 강구하였다. 따라서 사용되는 관수로가 펌푸, 관망, 터널, 조압수조, 분기관, 저수지, 폐단관 및 발브장치를 갖는 일련의 관수로내에 일어나서 전자계산기를 사용하면 송수 또는 배수관로 설계에 있어 설계자의 시간과 노력을 감소하고 정확한 결과를 얻을 수 있는 장점이 있다.

  • PDF

Infection Source and Epidemiology of Nontuberculous Mycobacterial Lung Disease

  • Jeon, Doosoo
    • Tuberculosis and Respiratory Diseases
    • /
    • 제82권2호
    • /
    • pp.94-101
    • /
    • 2019
  • Nontuberculous mycobacteria (NTM) are ubiquitous organisms that are generally found not only in the natural environment but also in the human engineered environment, including water, soil, and dust. These organisms can form biofilms and can be readily aerosolized because they are hydrophobic owing to the presence of the lipid-rich outer membrane. Aerosolization and subsequent inhalation were the major route of NTM lung disease. Water distribution systems and household plumbing are ideal habit for NTM and the main transmission route from natural water to household. NTM have been isolated from drinking water, faucets, pipelines, and water tanks. Studies that used genotyping have shown that NTM isolates from patients are identical to those in the environment, that is, from shower water, showerheads, tap water, and gardening soil. Humans are likely to be exposed to NTM in their homes through simple and daily activities, such as drinking, showering, or gardening. In addition to environmental factors, host factors play an important role in the development of NTM lung disease. The incidence and prevalence of NTM lung disease are increasing worldwide, and this disease is rapidly becoming a major public health problem. NTM lung disease is associated with substantially impaired quality of life, increased morbidity and mortality, and high medical costs. A more comprehensive understanding of the infection source and epidemiology of NTM is essential for the development of new strategies that can prevent and control NTM infection.