Pressure sensor placement method for real-time operation efficiency of water transmission mains |
Kim, Seong Han
(K-water Gwangju-Jeonnam Regional Division)
Choi, Doo Yong (K-water Institute) Kim, Kyoung Pil (K-water Institute) Lee, Sang Cheol (K-water Water Supply Development Department) |
1 | Cesario, A.L. and Davis, J.O. (1984). Calibrating Water System Models. J AM WATER WORKS ASS, 76(7), 66-69. |
2 | De Schaetzen et al. (2000). Optimal sampling design for model calibration using shortest path, genetic and entropy algorithms. URBAN WATER J, 2(2), 141-152. DOI |
3 | Farley B. et al. (2008). "Optimal location of pressure meters for burst detection", proceedings of the 10th Annual Water Distribution System Analysis Conference, 17-20 August 2008, Kruger National Park, South Africa. |
4 | Fatiha Nejjari et al. (2015). "Optimal pressure sensor placement in water distribution networks minimizing leak location uncertainty", 13th Computer Control for Water Industry Conference, 2-4 September 2015, De Montfort University, Leicester, UK. |
5 | Jun, H.D. et al. (2008). "A methodology to determine realtime monitoring locations for water distribution systems based on the effect index matrix", KWRA Annual Conference, 22-23 May 2008, Korea Water Resources Association, Daejeon, Korea. |
6 | K-water (2009). Guidebook for non-revenue water reduction in water supply network |
7 | K-water (2010). Guidebook for technical diagnosis of water transmission facilities |
8 | K-water (2012). Criteria for water flow meter placement and management |
9 | Kwon, H.J. (2013). Determination Methods of Pressure Monitoring Location in Water Distribution System, Journal of KWRA, Vol. 46, No. 11, 1103-1113. |
10 | LeChevallier and Kunkel (2014). Pressure Management: Industry Practices and Monitoring Procedures, Water Research Foundation (#WRF 4321). |
11 | MOE(Ministry of Environment) (2007a). Guideline for water flow meter placement and management |
12 | MOE(Ministry of Environment) (2007b). Standard specification of water supply construction |
13 | MOE(Ministry of Environment) (2010). Standards for water supply facilities |
14 | MOE(Ministry of Environment) (2014). Standard specification of water supply construction |
15 | Travis, Q.B., and Mays, L.W. (2007). Relationship between Hazen-Williams and Colebrook-White roughness values. J HYDRAUL ENG-ASCE, 133(11), 1270-1273. DOI |
16 | Vitkovsky, J.P. et al. (2003). Optimal measurement site locations for inverse transient analysis in pipe networks. Journal of Water Resources Planning and Management, 129(6), 480.492. DOI |
17 | Walski, T.M., (1983). Technique for calibrating network model. J WATER RES PL-ASCE, 109(4), 360-372. DOI |
18 | Water Authorities Association and WRc (1989). Network Analysis - A Code of Practice, WRc, Swindon, England. |
19 | Zheng Yi Wu et al. (2015). "Software prototype for optimization of monitoring and data logging in water distribution systems", 13th Computer Control for Water Industry Conference, 2-4 September 2015, De Montfort University, Leicester, UK. |
20 | Yoo do G et al. (2012). Optimization of pressure gauge locations for water distribution systems using entropy theory, Environmental Monitoring and Assessment, 184:7309-7322. DOI |