• Title/Summary/Keyword: Water switching

Search Result 114, Processing Time 0.03 seconds

Development of Data-Flow Control Algorithm of Wireless Network for Sewage Disposal Facility

  • Jung, Soonho;Shin, Jaekwon;Kang, Jeongjin;Lee, Seungyoun;Lee, Junghoon
    • International journal of advanced smart convergence
    • /
    • v.4 no.2
    • /
    • pp.14-19
    • /
    • 2015
  • Recently, water sewage disposal facilities are able to manage real-time data collection and record management through compact broadband modem LAN switching technology. Therefore, it needs more stable and efficient facility management. So, we required practical use of environmental facilities convergence based on broadband integrated modem. In this paper, we proposed short distance wireless communication network of compact broadband modem for sewage disposal facilities. And it received data inside of water treatment facility using the two communication methods (IEEE802.11x and IEEE802.15.4x). Then, our proposed an data-flow control algorithm of wireless network technology will prioritize processing data when emergency happen through collecting data, analysis data and processing. Lastly, we proved usefulness by experiment and simulation analysis.

Evaluation of the Middle Part of the Nuclear Fuel Cycle

  • Kovac, Michal
    • Nuclear Engineering and Technology
    • /
    • v.48 no.1
    • /
    • pp.169-174
    • /
    • 2016
  • This article describes a comprehensive methodology for the evaluation of the middle part of nuclear fuel cycles. Evaluation of fuel cycles is basically divided into two parts. The first comprises nuclear calculation, i.e., creation of the strategy for nuclear fuel reloading and core design calculations. The second part is the business-economic evaluation of the selected reloading strategy, which can be done either by financial analysis or economic analysis. The financial analysis incorporates the perspectives of a company while the economic analysis can be used primarily by national economists or politicians. This methodology was applied to a case study that is focused on impacts of switching from a 12-month to an 18-month fuel cycle strategy for Water-Water Energetic Reactor (VVER)-1000 reactors.

A Study on the Development of Analytical Methods and Behaviors of Environmental Pollutants(III) : On-Line System for Preconcentration and Separation of Trace Phenols by HPLC (환경 오염물질의 정량법 개발과 거동에 관한 연구(III) : 미량 페놀류의 HPLC 정량을 위한 온 라인 농축)

  • Lee, Dai Woon;Kim, Jin Young;Park, Young Hun;Moon, Myeong Hee
    • Analytical Science and Technology
    • /
    • v.7 no.1
    • /
    • pp.33-39
    • /
    • 1994
  • The purpose on this study was to develop a new improved chromatographic method for determination of trace phenols from environmental waste water. The research was carried out with selected 8 phenols, and solid-phase extraction was employed as sample pretreatment method. The coupling of XAD-4 and Dowex $1{\times}8$ resin as preconcentration column increased the selectivities toward interferences coexisted in matrix. Automation was accomplished with on-line process of pretreatment and HPLC system. After elution of sample through XAD-4 column, phenols were adsorbed by dispersion force, then displaced from it by ACN basified, simultaneously and selectively readsorbed via anion exchange on Dowex $1{\times}8$. Dowex $1{\times}8$ column was washed by water. Phenols readsorbed were removed from Dowex $1{\times}8$ column by a minimum volumn of methanol containing HCl. Each pretreatment step was connected by switching valves and the eluate was directly on-line injected to obtain fast and reliable results into the HPLC. Recovery of phenols was greater than 90%. To examine utility of this method, analysis of phenols from laboratory waste water sample which was added some organic pollutants to find with phenols on environmental waste water were also accomplished without their interference effects.

  • PDF

A Performance Study on Silica Gel Adsorption Desalination System Utilizing Low Temperature Heat Sources (저온 활용을 위한 실리카겔 흡착식 담수화시스템의 성능연구)

  • Hyun, Jun-Ho;Israr, Farrukh;Lee, Yoon-Joon;Chun, Won-Gee
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.6
    • /
    • pp.39-46
    • /
    • 2013
  • This work introduces a simple one-reactor adsorption desalination system that harnesses low temperature heat sources (solar energy, waste heat), which has been experimentally studied to elicit the most suitable design parameters and operating conditions. The design process of the system was divided into three parts to reflect the operating principle of desalination technology with application of adsorption processes. First, the evaporator for the vaporization of saline water was designed, then the reactor for the adsorption and release of the steam, followed by the condenser for condensation of the fresh water. The specific water yield is measured experimentally with respect to the time while controlling parameters such as heat source temperatures, coolant temperatures, system switching and half-cycle operational times. The present system well demonstrates the applicability of silica gel in relation to adsorption technologies that utilize low temperature heat sources ranging from 60 to $80^{\circ}C$, such as solar energy and waste heat.

External mechanisms driving ecosystem changes in a coastal wetland, the Mississippi Delta, USA

  • Ryu, Junghyung;Liu, Kam-biu;McCloskey, Terrence A.;Yun, Sang-Leen
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.85-85
    • /
    • 2022
  • The world's most extensive and active deltas, Louisiana's wetlands, are deteriorating rapidly due to multiple stressors such as the discharge of the Mississippi River, sea-level rise, and coastal retreat, the substantial but spatially and temporally variable impacts. However, the ecological and anthropogenic histories, the mode of environmental changes on a multi-millennial timescale have not been thoroughly documented. This study, a palynology-based multiproxy analysis, investigates hydrological, geological, geochemical, and anthropogenic impacts on southern Louisiana wetlands and a variety of external forcing agents influencing ecological succession. Sediment cores extracted from a small pond on a mangrove-dominate island near Port Fourchon, Louisiana, USA yielded a 4,000-year record. The site has been transformed from freshwater to saline water environments, to a mangrove dominant island over the late Holocene. The multivariate principal component analysis identified the relative strength of external drivers responsible for each ecological shift. The Mississippi River delta cycle (lobe switching) was the dominant driver of ecosystem changes during the late Holocene, while relative sea-level rise, tropical cyclones, climate, and anthropogenic effects have been the main drivers late in the site's history.

  • PDF

ADVANCED DVI+

  • Kwon, Tae-Soon;Lee, S.T.;Euh, D.J.;Chu, I.C.;Youn, Y.J.
    • Nuclear Engineering and Technology
    • /
    • v.44 no.7
    • /
    • pp.727-734
    • /
    • 2012
  • A new advanced safety feature of DVI+ (Direct Vessel Injection Plus) for the APR+ (Advanced Power Reactor Plus), to mitigate the ECC (Emergency Core Cooling) bypass fraction and to prevent switching an ECC outlet to a break flow inlet during a DVI line break, is presented for an advanced DVI system. In the current DVI system, the ECC water injected into the downcomer is easily shifted to the broken cold leg by a high steam cross flow which comes from the intact cold legs during the late reflood phase of a LBLOCA (Large Break Loss Of Coolant Accident)For the new DVI+ system, an ECBD (Emergency Core Barrel Duct) is installed on the outside of a core barrel cylinder. The ECBD has a gap (From the core barrel wall to the ECBD inner wall to the radial direction) of 3/25~7/25 of the downcomer annulus gap. The DVI nozzle and the ECBD are only connected by the ECC water jet, which is called a hydrodynamic water bridge, during the ECC injection period. Otherwise these two components are disconnected from each other without any pipes inside the downcomer. The ECBD is an ECC downward isolation flow sub-channel which protects the ECC water from the high speed steam crossflow in the downcomer annulus during a LOCA event. The injected ECC water flows downward into the lower downcomer through the ECBD without a strong entrainment to a steam cross flow. The outer downcomer annulus of the ECBD is the major steam flow zone coming from the intact cold leg during a LBLOCA. During a DVI line break, the separated DVI nozzle and ECBD have the effect of preventing the level of the cooling water from being lowered in the downcomer due to an inlet-outlet reverse phenomenon at the lowest position of the outlet of the ECBD.

Development of Adsorption Desalination System Utilizing Silica-gel (실리카겔을 이용한 흡착식 담수화 시스템의 기초연구)

  • Hyun, Jun-Ho;Kim, Yeong-Min;Jung, Jin-Ho;Lee, Yoon-Joon;Chun, Won-Gee
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.204-209
    • /
    • 2011
  • According to the environment report of UN, korea was classified as potable water shortage countries. Approximately 71% of the Earth's surface is covered by ocean. However, it is difficult to use for industry of residential purpose without a certain processing. The development of solar and waste-heat used absorption desalination technology have been examined as a viable option for supplying clean energy. In this study, the modelling of the main devices for solar and waste-heat used and adsorption desalination system was introduced. The design is divided into three parts. First, the evaporator for the vaporization of the top water is designed, and then the reactor for the adsorption and release of the steam is designed, followed by the condenser for the condensation of the fresh water is designed. In addition, new features based on the energy balance are also included to design absorption desalination system. In this basicresearch, One-bed(reactor) adsorption desalination plant that employ a low-temperature solar and waste energy was proposed and experimentally studied. The specific water yield is measured experimentally with respect to the time controlling parameters such as heat source temperatures, coolant temperatures, system switching and half-cycle operational times.

  • PDF

Revisiting Horton Index Using a Conceptual Soil Water Balance Model (개념적인 토양수분수지 모형을 이용한 Horton 지수의 재논의)

  • Choi, Daegyu;Kim, Sangdan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.5B
    • /
    • pp.471-477
    • /
    • 2010
  • In this study, the variability of the Horton index which is ratio of vaporization and wetting water is investigated using a conceptual soil water balance model. From the proposed model, the steady-state soil water probabilistic density function is derived through meteorological and watershed characteristics and then the sensitivity of Horton index to the precipitation occurrence rate and the mean of wet day precipitation is examined. As a result, the inter-annual variability of the Horton index is lower than that of precipitation and they showed the strong negative correlation. It is also shown that although precipitation is not varied, the Horton index can be varied due to the fluctuation of the precipitation occurrence rate and the mean of wet day precipitation. In addition, it is presented that there is a non-linear relationship which has a critical point switching proportional or inverse relationship between the Horton index and two main characteristics of precipitation process.

Operation Characteristics of the SBR Process with Electro-Flotation (EF) as Solids-liquid Separation Method (전해부상을 고액분리 방법으로 적용한 SBR 공정의 운전 특성)

  • Park, Minjeong;Choi, Younggyun
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.3
    • /
    • pp.340-344
    • /
    • 2008
  • Electro-flotation (EF) was applied to a sequencing batch reactor process (SBR) in order to enhance solids-liquid separation. Solids-liquid separation was good enough in the SBR coupled with EF (EF-SBR) and it was possible to maintain the concentration of mixed liquor suspended solids (MLSS) high in the EF-SBR. Under moderate organic loading condition (COD loading rate: 6 g/day), control SBR (C-SBR) showed similar treatment efficiencies with the EF-SBR. Under high organic loading condition (COD loading rate: 9.6 g/day), the solids-liquid separation in the C-SBR was deteriorated due to proliferation of filamentous bulking organisms at high F/M ratio. However, the EF-SBR was operated stably and with the high MLSS concentration (above 4,000 mg/L) regardless of the organic loading conditions during overall operating period leading to the satisfactory effluent quality. Gas production rate of the electrodes was gradually decreased because of anodic corrosion and scale build-up at the surface of cathode. However it could be partially overcome by use of corrosion-proof electrode material (SUS-316 L) and by periodic current switching between the electrodes.

The Microbe Removing Characteristics Caused by Dirty Water Using a Simple Pulsed Power System

  • Kim, Hee-je;Song, Keun-ju;Song, Woo-Jung;Kim, Su-Weon;Park, Jin--Young;Joung, Jong-Han
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.3
    • /
    • pp.91-95
    • /
    • 2004
  • The pulsed power system is widely available for use in pulse generator applications. Generally, the pulse generator is required for very short pulse width and high peak value. We have designed and fabricated our own pulsed type power system and through its use, we investigated microbe removal characteristics. This paper introduces a simple pulsed power system for removing various microbes caused by dirty water. This system includes a 2 times power supply circuit, IR2110 operated by using a fixed voltage regulator 7812 and 7805, and the switching MOSFET (Metal Oxide Semiconductor Field Effect Transistor). We can also control this process by using a PIC one chip microprocessor. As a result, we can obtain good removing characteristics of various microbes by adjusting the charging voltage, the pulse repetition rate and the electrical field inducing time.