• 제목/요약/키워드: Water spray system

검색결과 271건 처리시간 0.028초

분무장치 형상 변경을 통한 초음파 열분해 증착 시스템의 증착 성능 개선 (Improvement of Deposition Performance of Ultrasonic Spray Pyrolysis Deposition System through Atomizer Shape Modification)

  • 김규언;이재후;전재건;박성환;이치범
    • 한국생산제조학회지
    • /
    • 제24권4호
    • /
    • pp.469-474
    • /
    • 2015
  • In ultrasonic spray pyrolysis deposition, a precursor solution is evaporated by an ultrasonic atomizer, then gas-carried into a furnace where the solute is separated from the water vapor. After condensation, polymerization, and nucleation, the solute oxide forms a thin film. To improve the deposition efficiency, the ultrasonic atomizer was studied to optimize the evaporated gas flow. The vat cover was redesigned, using three versions with different inlet factors being tested through a computational fluid dynamic analysis as well as a water evaporation experiment. The atomization rate with a hemispherical cover with a $30^{\circ}$ inlet was found to be 2.4 times higher than that with the original. This improvement was verified with fluorine-doped tin oxide spray pyrolysis deposition. The film obtained with the modified vat cover was 2.4 times thicker than that obtained with the original vat cover.

뿜칠형 수용성 고무화 아스팔트 차수재의 성능평가 및 폐기물 매립지 적용성 검토에 관한 연구 (A Study on Examination of Application in Waste Filled Land and Performance Evaluation as Waterproofing Material by the Spray Water-Soluble Rubber Asphalt)

  • 오상근;김형무;정문정;최은수
    • 한국건축시공학회지
    • /
    • 제1권2호
    • /
    • pp.165-173
    • /
    • 2001
  • This study examinated the application in construction field and the development of waterproofing material system by the spray water-soluble rubber asphalt to solve the problems of synthetic polymer sheet and gio membrane(A mat sheet of Bentonite) that had been used domestic waterproofing material in advance. As the result of study, characters of study water-soluble rudder asphalt are the follows: 1) The amount of water absorption was '0.06'g and the seepage quality was '0'g in result. 2) The tensile strength was about 30.7kgf/$\textrm{cm}^2 and the elongation was about 72.4% in result. 3) After reliance of temperature test had been ended, the tensile strength was about 72.4kgf/$\textrm{cm}^2 in low temperature and about 30.7kgf/$\textrm{cm}^2 in normal temperature. 4) After acid and alkaline treatment had been ended, the tensile strength was about 19.7kgf/$\textrm{cm}^2$ and about 21.9kgf/$\textrm{cm}^2 in result. 5) After chlorine ion treatment had been ended, the tensile strength was 28.5kgf/$\textrm{cm}^2$ and the elongation was 250% in result. 6) The impact performance was subsided at 1.5m height. 7) After promotion weathering had been ended, the tensile and elongation was about 26.0kgf/$\textrm{cm}^2, 214% in result. So, this study can propose the spray water-soluble rubber asphalt to satisfy the and durability of waste filled land.

  • PDF

자연환기량과 포그분무량 조절에 의한 온실 온습도의 동시제어 기법 연구 (A Study on the Control of the Temperature and Relative Humidity in Greenhouse by Adjusting the Amount of Natural Ventilation and Fog Spray Quantity)

  • 김영복;성현수;황승재;김현태;유찬석
    • 한국태양에너지학회 논문집
    • /
    • 제36권5호
    • /
    • pp.31-50
    • /
    • 2016
  • To develope a greenhouse fog cooling system to control the temperature and relative humidity simultaneously to the target value, a theoretical analysis and experiments were done. The control process includes the measuring of environmental variables, setting and coding of the water and heat balance equations to maintain the target temperature and relative humidity in greenhouse, calculating of the open level of the greenhouse roof window that governs the natural ventilation and spray water quantity, and operating of the motor to open/close the roof window and pump to spray for water. The study results were shown to be very good because the average air temperature in the greenhouse was kept to be about $28.2^{\circ}C$ with the standard deviation of about $0.37^{\circ}C$ compared to the target temperature of $28^{\circ}C$ and the average relative humidity was about 75.2% compared to the target relative humidity was 75% during the experiments. The average outside relative humidity was about 41.0% and the average outside temperature was $27.2^{\circ}C$ with the standard deviation of about $0.54^{\circ}C$. The average solar intensity in the greenhouse was 712.9 W. The wind velocity of outside greenhouse was 0.558 m/s with the standard deviation of 0.46 m/s.

작동 유체에 따른 단순 압력식 연료노즐의 분무특성 (Spray Characteristics of the Simplex Atomizer with Working Fluids)

  • 최채홍;임병준;최성만
    • 한국추진공학회지
    • /
    • 제13권6호
    • /
    • pp.41-47
    • /
    • 2009
  • 작동 유체에 따른 APU 가스터빈에 적용되는 연료노즐의 분무특성을 확인하였다. 액체연료에 따라 점도, 표면장력 및 비중 등이 상이하여 분무특성이 변화될 수 있다. 본 연구에서는 연료 물성치 변화에 따른 분무특성을 이해하기 위하여 케로신과 유사한 특성을 갖는 보정 유체 2와 일반적으로 연료노즐의 분무특성을 시험하는데 사용하는 물을 이용하여 분무 시험을 수행하였다. 분무가시화와 분무입자 크기 및 분포를 ND-Yag 레이저 및 PDPA(Phase Doppler Particle Analyzer)를 이용하여 측정하였다. 분무시험 결과, 두 작동유체의 분무형태는 유사하게 나타났으며 주 분무영역에서의 SMD 또한 유사하게 분포됨을 확인할 수 있었다.

고도정수처리용 콘크리트 금속용사 피막의 내오존성 및 오존처리 후 부착강도 평가에 관한 실험적 연구 (Experimental Study on Evaluation of Bond Strength after Ozone Treatment and Ozone Resistance of Concrete Metal Spray Coating for Advanced Water Treatment)

  • 박진호;장현오;이한승
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제22권4호
    • /
    • pp.68-75
    • /
    • 2018
  • 기존의 정수처리 방법으로는 제거되지 않는 물질이 발생함에 고도정수 처리 시설의 도입이 증가하고 있다. 그러나 오존을 이용한 고도정수처리 시설의 내부 방수 방식재는 오존의 산화력에 의해 열화되며 콘크리트까지 영향을 미쳐 내구성 저하의 원인이 된다. 본 연구에서는 내오존성 및 내화학성이 뛰어난 금속 패널을 기존의 시공법 보다 손쉬운 방법으로 시공하기 위한 방법으로 금속용사 공법을 이용하여 수처리 시설 콘크리트 구조물의 열화를 원천적으로 방지하기 위한 마감공법 개발 연구의 일원으로 용사금속 종류 및 피막의 표면처리 방법에 따른 내오존성 평가를 실시하였으며, 오존처리 후의 부착강도를 평가하였다. 실험결과 용사금속 Ti이 용사 후에도 내오존성이 뛰어난 것으로 나타났으며 표면처리 방법으로는 테프론계 봉공처리제를 사용하여 마감하는 것이 내오존성 및 부착성능 확보에 가장 적합한 방법이라 판단된다.

이유체 선회분사 노즐의 액적크기에 관한 실험적 연구 (An Experimental Study on the Drop Size of a Twin-Fluid Swirl Jet Nozzle)

  • 오제하;김원태;강신재;노병준
    • 한국분무공학회지
    • /
    • 제1권1호
    • /
    • pp.21-27
    • /
    • 1996
  • This experimental study was to investigate spray angles and drop sizes in an external mixed twin-fluid swirl jet nozzle. Twin-fluid swirl jet nozzle with swirlers designed four swirl angles such as $0^{\circ},\;22.5^{\circ},\;45^{\circ},\;64.2^{\circ}$ was employed. A PDA system was utilized for the measurement of drop size and mean velocity. Water and air were used as the working fluids in this experiment. The mass flow rate of water was fixed as 0.03 kg/min, and air flow rates were controlled to have the air/liquid mass ratio from 1.0 to 6.0. As a result, swirl angle controlled to spray angles and drop sizes. It was found that swirl angle was increased with spray angle and with decreased SMD. However, the effect of swirl angle was reduced at large air/liquid mass ratio(Mr=6.0).

  • PDF

최근 야외농장에서 실시하고 있는 뉴캣슬병 생독백신 접종효능에 대한 평가 (Evaluation of the recent live vaccination effects against Newcastle disease under field conditions)

  • 송창선;이윤정;한명국;성환우;강경수;이중복;김재학
    • 대한수의학회지
    • /
    • 제40권3호
    • /
    • pp.563-573
    • /
    • 2000
  • Periodic outbreaks of Newcastle disease (ND) caused by velogenic viscerotropic ND virus (vvNDV) has become a major concern in Korea nowadays. Throughout last epidemic, the winter season in 2000, most chicken flocks infected early, under 2-4 weeks of age, showed high mortality up to 50-100%. Serum samples collected from 201 breeder, 284 layer and 112 broiler chicken flocks were examined to evaluate the efficacy of various vaccination methods and programs routinely used for mass vaccination in the field poultry farms. Despite repeated live vaccination, most poultry flocks vaccinated by drinking water route using nipple water supply system failed to produce solid active immune response to NDV during the growing time. In the present study, we applied the spray vaccination technique using Ulvavac or Desvac sprayer to the experimental poultry flocks and examined the efficacy of live vaccination effects induced by it under field condition. Measurable antibody to NDV as well as early protection against vvNDV challenge were found in poultry flocks vaccinated by spray route. Further, we did not found significant post vaccination reactions caused by spray vaccination if properly administered. These data indicate that the spray vaccination will be safe and reliable mass vaccination method for the prevention of ND.

  • PDF

LPG 액상 분사 시 인젝터 주위의 Icing 현상에 관한 연구 (I) (A Study on the Development of Icing by Injection of LPG in the Liquid Phase around Injector (I))

  • 김우석;박정철;박심수;유재석;이종화
    • 한국자동차공학회논문집
    • /
    • 제11권1호
    • /
    • pp.87-94
    • /
    • 2003
  • Recently, LPLi(Liquied-Phase LPG injection) system is studied for the new stringent emission regulations. But , there are some problems to be solved such as injector tip icing and fuel leakage for LPLi system development. In this paper, the icing problem near injector tip which leads to difficulty of accurate A/F control was studied and reported. Icing of injector tip and port wall was observed at all the cases in this study regardless of injection duration and angle, air humidity change. The spray angle of LPLi was observed approximately two times wider than that of Gasoline injection. This makes the LPLi spray collide with intake port around injector tip. Temperature of the wetted area was decreased and icing of water vapor contained in intake air because of evaporation of the fuel film. The ice of the injector tip and port wall is also affected by the materials related to heat transfer.

덕트 유동에서 증발을 수반하는 액상 스프레이의 혼합 특성에 대한 실험적 연구 (An experimental study on the mixing of evaporating liquid spray with duct flow)

  • 김영봉;최상민
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2005년도 제31회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.93-96
    • /
    • 2005
  • High temperature furnace such as Steam power plant and incinerator contribute considerable part of NOx generation and face urgent demand of De-NOx system. Reducing agents are necessary to use De-NOx system. In this study mixing caused by direct injection of reducing agent solution spray into flue gas duct was measured. Carbonated water was used as tracer and simulated agent because ammonia as a reducing agent is not proper to experiment. Mixing and evaporation must occur simultaneously and quickly enough to achieve desirable efficiency. To achieve that, the angle of attack of static mixer and the location is simulated and $CO_2$ concentration is measured.

  • PDF

Effectiveness of Friction Loss Calculation Used for Water Mist Fire Extinguishing System on Marine Vessels

  • Lee Kyung-Woo;Kim You-Taek;Lee Young-Ho;Kim Mann-Eung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권1호
    • /
    • pp.86-97
    • /
    • 2005
  • Nowadays, Water Mist Fire Extinguishing System is increasingly used in maritime field for various application. The fire extinguishing capability of the system should be verified by hydraulic calculation in the same manner as the conventional water based fire extinguishing system such as sprinkler system. water spray system and etc. Additionally, the review of effectiveness of friction loss calculation method used for hydraulic calculation is needed because the pipe flow characteristic of its piping system has higher Reynolds number than that of the conventional system. In this paper the review work was carried out based on the NFPA Code 750.