• Title/Summary/Keyword: Water removal

Search Result 4,254, Processing Time 0.033 seconds

Development of Constructed Wetland using Sand and Oyster shell for Sewage Treatment (모래와 굴패각을 이용한 인공습지 오수처리장치 개발)

  • Park, Hyun-Geoun;Lee, Chun-Sik;Lee, Hong-Jae;Seo, Dong-Cheol;Heo, Jong-Soo
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.5
    • /
    • pp.437-446
    • /
    • 2004
  • To develop sewage treatment apparatus by natural purification method, the sewage treatment plant that consisted of aerobic and anaerobic plot was constructed. And then, the effects of treatment conditions on the removal of pollutants in the relation to sewage loading, sewage injection method and season according to the pebble kind. Removal rate of BOD and COD according to the sewage loading in effluent were over 95 and 77%, respectively. Removal rate of nitrogen in treated water by aerobic plot and effluent using sand were about 22~40 and 49~75%, respectively. Those of effluent using sand 75%+ oyster shell 25% and sand 50%+ oyster shell 50% as filter media in comparison with using sand were about 7~25 and 16~23%, respectively. Removal rate of phosphorus in treated water by aerobic plot and effluent using sand as filter media were about 30~36 and 52~56%, respectively. Those of effluent using sand 75%+ oyster shell 25% and sand 50%+ oyster shell 50% in comparison with using sand as filter media were about 11~40 and 12~45%, respectively. Removal efficiency of BOD and COD according to the intermittent injection method of sewage were slightly decreased, but those of nitrogen and phosphorus were little varied in comparison with continuous injection method. Removal efficiency of BOD and COD in winter in comparison with the others were little varied, but those of nitrogen and phosphorus slightly decreased.

Removal Efficiency of Settleable Solids in Seawater Aquaculture Farm Wastewater (하이드로싸이클론을 이용한 해수 양식장 침전 고형물의 제거 효율 평가)

  • Junhyuk Seo;Pyongkih Kim;Jeonghwan Park
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.56 no.1
    • /
    • pp.116-123
    • /
    • 2023
  • Flow-through aquaculture systems generate large amounts of wastewater containing compounds such as solids that can settle near aquafarms and cause eutrophication. The settled solids are often reintroduced into flow-through systems, and aquatic animals can be affected by the solids and pathogens associated with these solids. For a sustainable aquaculture operation, adequate wastewater treatment is required. Hydrocyclones are one of the most promising technologies for the removal of solids in aquaculture wastewater. In this study, a model for performance prediction of hydrocyclones was investigated under three different operating conditions: water temperature, solids concentration, and water inlet velocity. The synthetic solids solution was prepared using settled solids from abalone aquaculture farms. The daily solids removal rates of the tested hydrocyclones ranged from 0.18 to 26.0 g solids-m-3-day-1, and removal efficiency ranged from 5.1 to 34.4%. The inlet water velocity had the greatest effect on solids removal and hydrocyclone efficiencies. The following multiregression model equation was derived from the daily solids removal rate (g solids-m-3-day-1) results for water temperature (T, ℃), solids concentration (SS, mg-L-1), and tangential inlet water velocity (TIV, m-sec-1): daily solids removal rate: f(z)=4.465+0.809TIV-0.375T+0.217SS (r2=0.976).

SS Removal-rate Efficiency of Storm-water Detention Storage Tank Depending upon Length, Inside Training Wall and Gravel Filling (우수저류조의 형상과 도류벽 및 자갈채움에 따른 SS 제거효율)

  • Lee, Jong Tae;Seo, Hong Joon;Seo, Kyung A
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.5
    • /
    • pp.655-667
    • /
    • 2009
  • An experimental study is performed on reducing the pollutants supplied by storm water through enhancing efficiency of SS from the detention storage tank where CSOs are kept temporarily before discharge to the receiving water system. SS removal efficiency is investigated in accordance with various conditions of the detention pond-such as its length, the existence of training wall, and the use of gravel filling. The removal efficiency is strongly affected by the detention pond's length until the critical falling distance of the suspended solids is reached. For cases where the tank has a length longer than this critical condition, the removal rate shows less sensitivity. To enhance the SS removal efficiency of tanks of shorter than the critical length, we studied alternative types of tank in which inside training walls are installed. The results showed improvement of 14 to 37% in removal efficiency in 2hours detention(2 training walls). The important factor in achieving a high SS removal rate is ensuring the critical length of the detention pond, but for the cases where the basin length cannot be guaranteed, baffles or a gravel filling scheme may be introduced to attain considerable efficiency. The results of studying and comparing different storage tank conditions show that, in terms of elimination efficiency, a storage tank with gravel filling and training walls > a storage tank with gravel filling > a storage tank with training walls > an empty tank. The experimental results should contribute to development of related further research, by empirically verifying the already assumed importance of critical falling distance, training walls, and gravel filling schemes.

Nitrogen and Phosphorus Removal in Domestic Wastewater using SBR Process with Flow Changing Continuous Feed and Cyclic Draw (교대연속유입식 SBR 공정을 이용한 하수중의 질소 및 인 제거)

  • Seo, In-seok;Kim, Hong-suck;Kim, Youn-kwon;Kim, Ji-yeon
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.2
    • /
    • pp.203-208
    • /
    • 2006
  • A continuous feed and cyclic draw SBR process was developed to overcome flow rate fluctuation and to maximize organic matters utilization efficiency for nitrogen and phosphorus removal. The developed SBR process was operated with two parallel reactors. Influent was supplied to one reactor which was not obligately aerated. At the same time, the other reactor was just aerated without supplying influent. In addition this mode was changed periodically. Cycle time was 6hr and aeration time ratio($t_{aer}/t_{total}$) was 0.33, respectively. $COD_{cr}$ and SS removal efficiencies of 95% or higher were achieved. Nitrogen removal was so greatly influenced by influent $COD_{cr}/T-N$ ratio. At influent $COD_{cr}/T-N$ ratio of 5.7, removal efficiencies of ammonia-N, T-N and T-P were 96%, 78% and 55%, respectively. Influent $COD_{cr}/T-N$ of 4 or higher ratio was necessary to achieve 60% or higher nitrogen removal. Organic matters of influent was efficiently utilized in denitrification reaction and consumed COD has a good correlation with removed T-N(about 6.5 mgCOD/mgTN). Continuous feed and cyclic draw SBR process could be one of alternative processes for the removal of nutrients in rural area where $COD_{cr}/T-N$ ratio was low and fluctuation of flow rate was severe.

Removal of Arsenic in Synthesis Method and Characteristics of Fe(III)-ettringite (비소제거를 위한 Fe(III)-ettringite 합성방법 및 특성 연구)

  • Hong, Seong-Hyeok;Park, Hye-Min;Choi, Won-Ho;Park, Joo-Yang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.1
    • /
    • pp.15-21
    • /
    • 2011
  • Arsenic is one of the most abundant contaminant found in waste mine tailings, because of it's carcinogenic property, the countries like United states of America and Europe have made stringent regulations which govern the concentration of arsenic in drinking water. The current study focuses on different treatment methods for removal of arsenic from waste water. Treatment method the high strength arsenic waste water is treated with Fe(III)-ettringite by co-precipitation method. Number of experiments were carried out to decide the optimal dosage of Fe(III)-ettringite to treat arsenic waste water. The Fe(III)-ettringite was synthesized by taking appropriate equivalent ratios of calcium oxide and ferric chloride in proportion to the arsenic. The best removal efficiencies of 94% were observed at a As/(Ca: Fe) ratio of 1:3. The maximum removal of arsenic was observed in pH range of 12. But as the pH increases the arsenic removal efficiency decreases as portlandite is formed in the pH above 12. The analysis of surface of precipitate conform the needle like structure of ettringite. This treatment technique has promising features such as, the chemicals required in the treatment as well as the sludge generated can be reduced. The operating pH range is in alkaline region which is advantageous over traditional treatment process which has lower pH. Also the co-precipitation not only helps in removal of arsenic but also heavy metals.

Removal of Silica and Humic Acid from Brackish Water with Calcite (Calcite를 이용한 brackish water 내의 실리카와 휴믹산의 제거에 관한 연구)

  • 박소희;박재우
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.04a
    • /
    • pp.243-245
    • /
    • 2002
  • Brackish water desalination using reverse osmosis(RO) membrane is more useful and economic than sea water to solve the shortage of fresh water supply because of its low total dissolved solid(TDS) contents. Silica and humic acid in brackish water make serious fouling problems and cause the decline of permeate flux and increase of operating pressure. In this study, the experiments for removal of silica and humic acid were conducted with calcite particles to prevent membrane fouling and investigated the effect of pH of feed water Adsorption of silica to calcite was higher at pH=7.5 than 9.5 and removal rate was increased according to increase of initial concentration of silica. The effect of pH on adsorption of humic acid was not significant but at low initial concentration the adsorption of humic acid was enhanced at pH 7.5. The result of this study expect to apply to brackish water desalination experiment of flat-sheet reverse osmosis membrane.

  • PDF

The Effect of Chemical Admixtures on Removal of Scattered Dust

  • Son, Ho Jeong;An, Jung Min;Chung, Chul-Woo;Lee, Jae-Yong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.13 no.6
    • /
    • pp.594-601
    • /
    • 2013
  • One of the important problems associated with building demolition is the dust generated during the work. The only way to reduce the demolition dust is to use a dust net during water spraying. However, it is difficult to supply the necessary amount of water to remove demolition dust, thus making it difficult to apply this method on a demolition site. This work attempted to find an alternative approach to dust removal by incorporating surfactant and high range AE water reducer in the water being sprayed. Through the experiment, it was found that the addition of surfactant did not contribute to the removal of demolition dust. However, the use of high range AE water reducer showed better performance than spraying plain water, indicating that some amount of demolition dust had been adsorbed on the high range AE water reducer.

Property Conversion of Water and Removing Characteristics of Escherichia Coli Inner Discharge Tube With ZrO$_2$Beads (구형 ZrO$_2$를 충진한 방전관의 수질 변환 및 대장균제거 특성)

  • 이동훈;박재윤
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.3
    • /
    • pp.143-148
    • /
    • 2004
  • This paper shows property conversion of water and removing characteristics of Escherichia coli for discharge tube with $ZrO_2$ beads. At the result of the removal characteristic experiments of Escherichia coli using the discharge tube with $ZrO_2$ beads, because the electric field is also increased when input voltage is increased, the removal characteristic of Escherichia coli was appeared relation connection to input voltage. And if a passing number of test water in discharge tube with $ZrO_2$beads is increased, the removal ratio of Escherichia coli is to be increased because passing number of electric field section is increased. And if diameter of $ZrO_2$beads is increased, the removal time of Escherichia coli is to be decreased because dielectric polalization of $ZrO_2$beads. Also, the removal ratio of Escherichia coli of the discharge tube with $ZrO_2$beads. is appeared higher than the removal ratio of the discharge tube without $ZrO_2$beads. And a satulation punt of ozone and $H_2$ $O_2$generation density inner water was appeared near 60[min].

Adsorption-DAF Hybrid Process for the Simultaneous Removal of Algae and Organic Compounds (조류와 유기화합물의 동시제거를 위한 흡착 - DAF 복합공정)

  • Lee, Jae-Wook;Kwak, Dong-Heui;Choi, Seung-Phil;Jung, Heung-Joe
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.2
    • /
    • pp.208-214
    • /
    • 2004
  • Dissolved air flotation (DAF) is an effective solid/liquid separation process for low density floc particles such as algal, color-alum and clay-alum flocs produced from low turbidity water. The removal of taste and odor-causing organics (2-mthylisoboneol and geosmin) originating from algae in drinking water is a local and worldwide concern. Although DAF has been effectively applied for the removal of suspended solid, its application for the treatment of dissolved organic carbon is very limited. In this study, a new hybrid system consisting of adsorption and DAF processes was introduced for the simultaneous removal of algae and taste and odor-causing organics. Powdered activated carbon (PAC) was used as an adsorbent. In this proposed system, the major concern of eliminating the spent PAC from the system was also addressed. It was found that zeta potential of algae and PAC was increased with coagulant dosage, and the removal efficiency in DAF was also enhanced up to 90~95% under the given experimental conditions. Based on this study, the hybrid process was found to be a promising technology for the simultaneous removal of algae and dissolved organic pollutants.

Preparation of Composites using Carbonyl Iron with Ferromagnetic Properties for Effective Phosphorus Removal in Water (효과적인 수중의 인제거를 위해 강자성력을 가진 카보닐 철을 활용한 복합제 제조)

  • Kim, Jong Kyu
    • Journal of Korean Society of Water Science and Technology
    • /
    • v.26 no.6
    • /
    • pp.117-124
    • /
    • 2018
  • For the effective removal of phosphorus in water, a novel type of composite was prepared by combining Poly Alumiun Chloride, widely used in sewage/wastewater treatment plants, and Humic Acid particles, which are known to have phosphorus removal ability, with CI. The surface of the ferromagnetic CI particles was oxidized and activated, and then PAC and HA were synthesized to finally produce CIPAC and CIHA. CIPAC and CIHA prepared by this study showed similar results to the phosphorus removal efficiencies of PAC and HA coagulants. The novel composite has a larger weight than the conventional coagulant, and the coagulated sludge precipitates rapidly. The sludge could be easily separated in a short time if the external magnetic field was given by the ferromagnetic force of CIPAC and CIHA prepared with CI as support. Therefore, it can be concluded that if phosphorus removal is carried out using CIPAC and CIHA prepared through this study with external magnetic field, the sedimentation rate will be much faster than that of conventional coagulant. Thus it is possible to obtain a high economic benefit in the sludge recovery part.