• 제목/요약/키워드: Water reduce ratio

검색결과 386건 처리시간 0.029초

Development of a Water-Spraying Type Automatic Glochids Removal System for Cactus (Opuntia humifusa) Stem

  • Jang, Ik Joo;Park, Tusan;Ha, Yu Shin
    • Journal of Biosystems Engineering
    • /
    • 제41권3호
    • /
    • pp.201-207
    • /
    • 2016
  • Purpose: A water-spraying type automatic glochids removal system for cactus (Opuntia humifusa) stem was developed, and its performance was evaluated. The system was developed to reduce intensive human labor in removing glochids from cactus stem skin without inducing damage prior to further processing into value-added products. Methods: The developed system consists of conveyor and water-spraying systems. The conveyor system delivers cactus stems through water-spraying compartments and finally to a collecting box. In order to remove the glochids, rotating nozzles spray water over all areas (i.e., front and back faces and sides) of the cactus skin under controlled water pressure. Operating conditions such as conveyor speed, water pressure, angle of water-spraying nozzles, distance between conveyor belt and rotating nozzles, and angle of cactus flipping slide were adopted from our previous study and applied on the system design and manufacturing. The performance of glochids removal was evaluated by counting the number of glochids on the cactus stem before and after processing on the system. Results: The developed system performed efficiently and effectively under the pre-studied operating conditions except for the angle of cactus flipping slide. The new system had a glochids removal ratio of 94.1% without damaging the cactus skin. Considering the original number (approximately 30-60) of glochids, the remaining number was low (1-4), and most of them were found at the side edge of the cactus stem. This system can remove glochids from 360 cactus stems in 1 hr regardless of cactus size. Conclusions: The performance of the new system in glochids removal without damaging cactus skin is superior to any other existing device (i.e., brush type, rubber-friction type, and agitation type). The system is expected to be applied in cactus (O. humifusa) processing facilities.

통계적 경향 분석을 통한 남한강 상류 수계 수질 변동 해석 (Analysis of Water Quality Fluctuations in Upstream Namhan River Watershed Using Long-term Statistical Analysis)

  • 변상돈;노연정;임경재;김종건;김동진;홍은미
    • 한국농공학회논문집
    • /
    • 제62권5호
    • /
    • pp.15-26
    • /
    • 2020
  • There are fifteen non-point pollution management areas in Korea and three of them (Doam lake, Daegi district and Golji-cheon) are located in the upstream of the Namhan river watershed. Many efforts to reduce non-point sources (NPS) pollution have been conducted, however, water quality pollution in the watershed is still serious. To solve these problems, it is a priority to grasp water quality using statistical techniques. In this study, a trend analysis was conducted to evaluate the effect of NPS management in the watershed. The long-term trends from 1996 to 2018 of water quality properties were analyzed using data collected from the water environment information system. Seventeen monitoring stations were selected along the main stream in Namhan river basin. Monthly water quality properties (BOD, COD, TN, TP, TN/TP ratio, Conductivity, SS and Chlorophyll-a) were collected and analyzed by Mann-Kendall test and LOWESS. The results showed that the Conductivity tended to increase in all regions and was the highest level in Jijangcheon. Organic pollution such as BOD and COD tended to increase in the Jungseon area. SS did not show a large tendency, but it showed high concentration in the Doam watershed. In all regions, 40% of water quality properties showed a tendency to 'UP', 15% of water quality properties tended to 'DOWN', and 46% indicated no tendency. In order to determine the cause of this, additional research and measures for improvement are necessary. This study will be used for the establishment of water quality policy in the future.

국내 주택에서 물 피해 유형에 따른 부유곰팡이 농도 수준 평가 및 동정 분석 (Assessment of the level and identification of airborne molds by the type of water damage in housing in Korea)

  • 이주영;황은설;이정섭;권명희;정현미;서성철
    • 실내환경 및 냄새 학회지
    • /
    • 제17권4호
    • /
    • pp.355-361
    • /
    • 2018
  • Mold grows more easily when humidity is higher in indoor spaces, and as such is found more often on wetted areas in housing such as walls, toilets, kitchens, and poorly managed spaces. However, there have been few studies that have specifically assessed the level of mold in the indoor spaces of water-damaged housing in the Republic of Korea. We investigated the levels of airborne mold according to the characteristics of water damage types and explored the correlation between the distribution of mold genera and the characteristics of households. Samplings were performed from January 2016 to June 2018 in 97 housing units with water leakage or condensation, or a history of flooding, and in 61 general housing units in the metropolitan and Busan area, respectively. Airborne mold was collected on MEA (Malt extract agar) at flow rate of 100 L/min for 1 min. After collection, the samples were incubated at $25^{\circ}C$ for 120 hours. The cultured samples were counted and corrected using a positive hole conversion table. The samples were then analyzed by single colony culture, DNA extraction, gene amplification, and sequencing. By type of housing, concentrations of airborne mold were highest in flooded housing, followed by water-leaked or highly condensed housings, and then general housing. In more than 50% of water-damaged housing, the level of airborne mold exceeded the guideline of Korea's Ministry of Environment ($500CFU/m^3$). Of particular concern was the fact that the I/O ratio of water-damaged housing was greater than 1, which could indicate that mold damage may occur indoors. The distribution patterns of the fungal species were as follows: Penicillium spp., Cladosporium spp. (14%), Aspergillus spp. (13%) and Alternaria spp. (3%), but significant differences of their levels in indoor spaces were not found. Our findings indicate that high levels of mold damage were found in housing with water damage, and Aspergillus flavus and Penicillium brevicompactum were more dominant in housing with high water activity. Comprehensive management of flooded or water-damaged housing is necessary to reduce fungal exposure.

낙동강수계 주요 지류의 수질특성변화 및 LDC를 이용한 목표수질 평가에 관한 연구 (A Study on the Variation of Water Quality and the Evaluation of Target Water Quality Using LDC in Major Tributaries of Nakdong River Basin)

  • 이상수;강준모;박혜림;강정훈;김신;김진필;김경훈
    • 한국물환경학회지
    • /
    • 제36권6호
    • /
    • pp.521-534
    • /
    • 2020
  • In this study, the variation of water quality was analyzed for six sites in major tributaries of the Nakdong River Basin. Standard-FDC (Flow Duration Curve) was developed using PM (Percentile Method), one of the statistical FDC estimation methods. The LDC (Load Duration Curve) was obtained using the developed FDC. The current method and the LDC evaluation method were compared and analyzed to evaluate the achievement of TWQ (Target Water Quality). Regarding the monthly flow rate variation, the five sites showed the distribution of the lowest flow rate between May and June, indicating a high probability of dry weathering of the streams. The variation of water quality confirmed the vulnerable timing of flow rate in each site, and it is therefore deemed necessary to plan to reduce T-P and TOC. A comparison and evaluation of TWQ showed that there was a difference between the TWQ values achieved by the two techniques. In addition, the margin ratio to the 50% excess ratio can be found in the LDC evaluation. The results of the LDC evaluation by section and by month showed whether or not the water quality was exceeded by flow conditions, along with the vulnerable sections and timing. Accordingly, it is judged that this method can be used for water quality management in TMDLs (Total Maximum Daily Loads).

가자미피(皮) 젤라틴 제조를 위한 전처리 방법의 검토 (Investigation of Pretreatment Method for Gelatin Preparation from Flounder Skin)

  • 강태중;전유진;김세권;송대진
    • 한국수산과학회지
    • /
    • 제25권2호
    • /
    • pp.93-102
    • /
    • 1992
  • In order to reduce long preparating time for alkali pretreated B-type gelatin, enzyme pretreatment was tried on flounder(Limanda aspera) skin for I-type gelatin. The optimal extraction conditions of the B-type gelatin were 9 folds of added water with material(w/w), 3 hrs of extraction time, $60^{\circ}C$ of extraction temperature and pH 5. The maximum amount of I-type gelatin was extracted at $60^{\circ}C$ for 3 hrs using water controlled to pH 6.0(material : water= 1:9, w/w). The yields of the B- and E-type gelatin were $64.2\%\;and\;59.2\%,$ respectively. The B-type was superior to the B-type in physical properties such as jelly strength, viscosity and electric conductivity. Molecular weight of B-type was so far larger than that of the E-type due to different pretreatment method. Hydrolysis ratio of the E-type was higher than that of the B-type because of its molecular weight. Results suggest that B-type product would be better than I-type as fish skin gelatin but E-type was desirable in hydrolyzate preparation.

  • PDF

욕실과 인접한 아파트 드레스룸의 결로 원인 분석 (An Experimental and Simulation Analysis of Condensation in the Walk-in Closet Attached to Apartment Bathroom)

  • 최영우;김선혜
    • KIEAE Journal
    • /
    • 제17권4호
    • /
    • pp.89-94
    • /
    • 2017
  • Purpose: Condensation in walk-in closets attached to apartment bathroom has been known as an emerging issue that may threat occupants' comfort and health. Despite a number of design guidelines and enforcements to prevent condensation, condensation issues may still occur depending on various cases and scenarios. We aim to identify what condensation scenarios may lead to walk-in closet condensation and/or worse the existing condensation issues. Method: First we choose an actual walk-in closet of an apartment that suffers from sporadic condensation and resulting mold and mildew. Then we observe its relative humidity and temperature after the bathroom is used, in which excessive vapor is thought to be transported to the walk-in closet. We analyze Temperature Difference Ratio - a domestic indicator of condensation occurrence, and dew point temperature to compare it with surface temperature using 2D heat transfer simulation upon various condensation scenarios. Result: TDR of the test walk-in closet turns out be OK despite mold and mildew actually occurring. Hot water pipe installed in the floor would greatly reduce condensation. If hot water pipe in the upper floor, however, is not used, or hot water pipe of the closet is turned off during swing seasons, it is expected that condensations may still occur.

분말상 탄닌수지로 제조한 PB의 물리.기계적 특성 (Physical and Mechanical Properties of Particleboard made with Powdered Tannin Adhesives)

  • 강석구;이화형
    • 한국가구학회지
    • /
    • 제14권2호
    • /
    • pp.1-12
    • /
    • 2003
  • This study was carried out to determine the mechanical and physical properties of particle boards glued with condensed tannin (Wattle Tannin) powder that was single-molecule phenolic compounds like powdered phenolic resin. Our findings are; 1) It is necessary to spray water on the chip surfaces for effective application of powdered -form tannin resin. It shows that the best and optimum mat moisture increase is 14% of water spray on the surface of chips for developing PB properties. 2) In general, for both liquid and powdered tannin adhesives, their physical and mechanical properties has been proportional to the increase of resin level. But, the most efficient addition ratio is 16% of resin on dry basis. Specially, it is found that the resin level influences on the amount of free formaldehyde emission. The higher the resin level is, the lower the emission is. These phenomena seem to result from the increase of hexamine or formaline in the adhesives used as a hardener, that reduce the free-formaldehyde amount by reaction of tannin of poly-molecule and water. 3) The optimum condition for manufacturing PBs is the condition of hexamine of 5% and formaline of 6% in mechanical and physical properties. Hexamine is superior to formaline in mechanical and physical properties along with the control of the free formaldehyde emission amount. The result of NaOH's addition is insignificant in all experiments of both mechanical and physical properties.

  • PDF

혈관조영검사에서 매개변수 변화에 따른 Roadmap 영상의 화질평가 (Evaluation of Roadmap Image Quality by Parameter Change in Angiography)

  • 공창기;송종남;한재복
    • 한국방사선학회논문지
    • /
    • 제14권1호
    • /
    • pp.53-60
    • /
    • 2020
  • 이 연구의 목적은 Roadmap 영상에서 화질에 영향을 미치는 인자들을 알아보기 위한 것으로, 조영제의 희석률, Collimation Field, Flow Rate를 변화하여 연구를 하였다. 화질의 정량적인 평가를 위해, 아크릴를 이용하여 3mm 혈관모형의 Water Phantom을 자체 제작하였고, 자체 제작한 혈관모형의 Water Phantom으로 Roadmap 영상을 획득하고, SNR(Signal to Noise Ratio)과 CNR(Contrast to Noise Ratio)을 분석하였다. CM : N/S 희석률 변화에 대한 연구에서 CM : N/S 희석률을 (100%~10% : 100%)로 변화를 주었으며, 혈관모형 Water Phantom을 이용하여 촬영한 Roadmap 영상의 SNR과 CNR의 측정 결과 CM에 N/S 희석률이 높아질수록 SNR의 측정값이 점차적으로 낮아짐을 나타났고, CNR의 측정값도 점차적으로 낮아짐을 나타났다. 결론적으로 CM : N/S의 희석률이 높아질수록 SNR과 CNR 낮아짐을 확인하였고, CM : N/S의 희석률(100%~70 : 30%)에서 유의한 이미지를 얻을 수 있음을 확인하였다. Collimation Field 변화에 대한 연구에서 혈관모형 Water Phantom을 이용하여 Colimation Field를 혈관모형 중심으로 좌, 우 2 cm 간격으로 좁히면서 0 cm, 2 cm, 4 cm, 6 cm, 8 cm 10 cm, 12 cm으로 각각 변화를 주었으며, Roadmap을 촬영한 영상의 SNR과 CNR의 측정 결과는 Collimation Field를 혈관모형 중심으로 좁힐수록 SNR과 CNR의 측정값이 증가하는 것을 확인할 수 있었다. Flow rate 변화에 대한 연구에서 Autoinjector의 Volume을 15로 일정하게 하고, Flow Rate를 1, 2, 3, 4, 5, 6, 7, 8, 9, 10 으로 각각 변화를 주었다. 혈관모형 Water Phantom을 이용하여 Roadmap 영상을 촬영한 이미지의 SNR과 CNR의 측정 결과 Flow Rate를 증가했을 때, SNR의 측정값이 점차적으로 감소하다가 Flow Rate 9~10에서 SNR의 측정값이 점차적 증가를 보였고, CNR의 측정값도 점차적으로 감소하다가 Flow Rate 9~10에서 CNR의 측정값이 점차적으로 증가를 보였다. 그러나 ROI Mean 값과 Background Mean 값으로 SNR과 CNR의 상관관계를 확인할 수 없었다. 상관관계를 확인하기 위해 Flow Rate 변화에 따른 Roadmap 연구는 향후 더 많은 연구로 확인해야 할 것으로 사료된다. 결론적으로 Roadmap 영상의 화질에 영향을 미치는 인자들을 알아보기 위해 조영제의 희석률, Collimation Field, Flow Rate 변화에 대한 연구에서 조영제에 N/S의 희석률이 증가할수록 SNR과 CNR이 낮아져 화질과 대조도가 낮아지는 것을 확인하였으며, Collimation Field를 좁힐수록 SNR과 CNR이 증가하여 화질과 대조도가 높아지는 것을 확인하였다. 그러나 Flow Rate 변화에 대한 연구에서는 상관관계를 확인할 수 없었다. 검사 및 시술을 할 때 신장의 영향을 최소화하기 위해 적절한 조영제 농도 선택과 대조도 향상 및 피폭 감소를 위한 적절한 Collimation Field를 사용하는 것이 유용할 것으로 판단된다.

양전하가 부가된 수처리 필터의 입자제거특성에 관한 연구 (A Study on the Positively Charged Filter for Removing Fine Particles in Water)

  • 정성학;김종원;김상희;전병헌;이승갑;이재근;안영철
    • 설비공학논문집
    • /
    • 제24권5호
    • /
    • pp.454-460
    • /
    • 2012
  • The purpose of the present work is to investigate the removal characteristics of positively charged filters for capturing negatively charged particles such as bacteria and virus in water. In order to reduce the pressure drop and increase the filtration efficiency, the filter media, modified by charge modifier having positive functional groups, is developed and evaluated. Improved liquid filters have been developed with the modified surface charge to capture and adsorb particles by electrokinetic interaction between the filter surface and particles contained in an aqueous liquid. The positively charged filter media is composed of glass fiber, cellulose and poly-ethylenimine resin for positively charging with the variation of volume ratio. The zeta potential value of the positively charged filter is +37.92 mV at the glass fiber and cellulose content ratio of 50 : 50 with resin content of 100%, while that of the PSL test particle is -23.5 mV at pH 7. The removal efficiency of the electro-positively charged filter is 98% for PSL particles of 0.11 ${\mu}m$, while that of the negatively charged filter is 7%. The positively charged filter media showed the potential to be an effective method for removing fine particles from the contaminated water for liquid filtration.

EFFECTS OF MONOCALCIUM PHOSPHATE SUPPLEMENTATION ON PHOSPHORUS DISCHARGE AND GROWTH OF CARP (Cyprinus carpio) GROWER

  • Kim, J.D.;Ahn, K.H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제6권4호
    • /
    • pp.521-526
    • /
    • 1993
  • Two percent of monocalcuim phosphate (MCP) was added to control diet consisted of fish meal (18%), soybean meal (36%) and wheat flour (37%) in order to examine the effects on phosphorus (P) discharge and growth of carp (Cyprinus carpio). Growth trial, during which digestibility measurements were made over 7 days, was conducted for 4 weeks using a recirculated rearing system with a settling column for feces collection. Fishes (initial body weight of about 200 g) were fed five times a day upto satiation with tank controlled at $24-26^{\circ}C$. Fishes fed the diet containing 2% MCP (MCP-2) showed about two-fold improvement on both growth rate and feed utilization, compared to those of fishes fed the control diet; weight gain (129 g vs 62 g), feed conversion ratio (1.20 vs 2.46), protein efficiency ratio (2.09 vs 1.07) and daily growth index (3.70 vs 1.93). However, feed intakes were maintained at the same level (150 g/fish) between the two treatments. Dry matter digestibilities of two diets were relatively low, which were 58 and 60% for respective control and MCP-2 diets due to low digestibility of total carbohydrates. However, the digestibilities of both dietary protein (85%) and lipid (90%) of diets were relatively high. While all the P fed were observed to be discharged from fish fed control diet, the discharge from fish fed the MCP-2 diet was decreased up to less than the half (34.9 g/kg wt. gain) of the control. These present results revealed that the supplementation of dietary P requirement by MCP can not only promote growth performances but also reduce the level of P loading to water which is the primary water pollution indicator.