• Title/Summary/Keyword: Water quality parameters

Search Result 1,072, Processing Time 0.029 seconds

울산지역의 지하수 수질에 관한 통계학적 연구

  • 양운진
    • Journal of Environmental Science International
    • /
    • v.7 no.4
    • /
    • pp.461-466
    • /
    • 1998
  • One hundred and thirty two ground water samples from the Usan area were divided into urban and non-urban groupings and were assessed between 1993 and 1996. The results of statistical analysis were as follows: There were significant differences between the two groupings in the average value of the following water quality parameters: total hardness, nitrate , pH, iron, ammonia and chloride ion in the order of Z-score . Because total hardness, nitrate, and pH were also significant in ANOVA test, these three parameters can be regarded as the most sensitive parameters of artirial pollutants. By the comprehensive com- parison of Ulsan water Quality to that of Kangwon-do, all of the major parameters(pH, KMnO4 consumption, sulfate, chloride and hardness except nitrated were confirmed as being significantly Increased levels.

  • PDF

Characteristics of Aquatic Environment in Close-to-Nature Onchun Stream - Before and After the Flowing of the Nakdong River - (자연형 하천 온천천의 물환경 특성 - 하천유지 용수 공급 전, 후 -)

  • Kwon, Dong-Min;Son, Jun-Won;Yoo, Eun-Hee;Jeong, Jae-Won;Yun, Na-Na;Hwang, In-Jung;Kwon, Ki-Won;Bin, Jae-Hun;Cheigh, Hong-Sik
    • Journal of Environmental Science International
    • /
    • v.16 no.7
    • /
    • pp.831-838
    • /
    • 2007
  • In order to improve the water environment at urban streams in Korea, several river restoration projects have been initiated for past few years. This study evaluates the impact of diverting water application at the riverhead of Onchun stream through the monitoring program for several water quality and ecological parameters. Various water quality parameters and ecological item such as benthic macroinverterates has been investigated between 09/05 and 12/06. Analysis indicates that the application of diverting water from Nakdong river to Onchun stream distinctly improved several water quality parameters such as, PH, BOD, TN, TP and concentrations of heavy metals. Low flow augmentation also improve ecological indicies such as the diversity index of benthic macroinvertebrates. Generally speaking, releasing addition water from head water of Onchun stream improves various water environmental characteristics.

Design of Optical Biological Sensor for Phycocyanin Parameters Measurement using Fluorescence Technique

  • Lee, Sung Hwa;Mariappan, Vinayagam;Won, Dong Chan;Ann, Myungsuk;Yang, Seungyoun
    • International journal of advanced smart convergence
    • /
    • v.5 no.2
    • /
    • pp.73-79
    • /
    • 2016
  • Remote sensing and measurement are of paramount importance of providing information on the state of water quality in water bodies. The formation and growth of cyanobacteria is of serious concern to in land aquatic life forms and human life. The main cause of water quality deterioration stems from anthropogenic induced eutrophication. The goal of this research to quantify and determine the spatial distribution of cyanobacteria concentration in the water using remote sensing technique. The standard approach to measure water quality based on the direct measurement of the fluorescence of the chlorophyll a in the living algal cells and the same approach used to detect the phycobilin pigments found in blue-green algae (a.k.a. cyanobacteria), phycocyanin and phycoerythrin. This paper propose the emerging sensor design to measure the water quality based on the optical analysis by fluorescence of the phycocyanin pigment. In this research, we developed an method to sense and quantify to derive phycocyanin intensity index for estimating cyanobacteria concentrations. The development of the index was based on the reflectance difference between visible light band 620nm and 665nm. As a result of research this paper presents, an optical biological sensor design information to measure the Phycocyanin parameters in water content.

Deep Hydrochemical Investigations Using a Borehole Drilled in Granite in Wonju, South Korea

  • Kim, Eungyeong;Cho, Su Bin;Kihm, You Hong;Hyun, Sung Pil
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.19 no.4
    • /
    • pp.517-532
    • /
    • 2021
  • Safe geological disposal of spent nuclear fuel (SNF) requires knowledge of the deep hydrochemical characteristics of the repository site. Here, we conducted a set of deep hydrochemical investigations using a 750-m borehole drilled in a model granite system in Wonju, South Korea. A closed investigation system consisting of a double-packer, Waterra pump, flow cell, and water-quality measurement unit was used for in situ water quality measurements and subsequent groundwater sampling. We managed the drilling water labeled with a fluorescein dye using a recycling system that reuses the water discharged from the borehole. We selected the test depths based on the dye concentrations, outflow water quality parameters, borehole logging, and visual inspection of the rock cores. The groundwater pumped up to the surface flowed into the flow cell, where the in situ water quality parameters were measured, and it was then collected for further laboratory measurements. Atmospheric contact was minimized during the entire process. Before hydrochemical measurements and sample collection, pumping was performed to purge the remnant drilling water. This study on a model borehole can serve as a reference for the future development of deep hydrochemical investigation procedures and techniques for siting processes of SNF repositories.

Effect of Parameters on the Two-Phase Flow Distribution Characteristics of Refrigerants in a Horizontal T-Junction (수평 T형 분지관 내 냉매 이상유동 분배특성에 미치는 변수들의 영향)

  • Tae Sang-Jin;Cho Keumnam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.1
    • /
    • pp.31-37
    • /
    • 2006
  • The present study has been experimentally investigated the effect of geometric and operating parameters on the two-phase flow distribution of refrigerants in a horizontal T-junction. The operating parameters were the kind of refrigerants (R-22, R- l34a, and R-410A), saturated temperature, and the inlet mass flux and quality. The geometric parameters were the tube diameter and the tube diameter ratio. The measured data of refrigerants were compared with the values predicted using the models developed by several researchers for air/water or steani/water two-phase flow. Among the operating parameters, the inlet Quality was the most sensitive to the mass flow rate ratio. Between the geometric parameters, the tube diameter ratio was more sensitive than tube diameter.

Deriving Water Quality Criteria of Total Nitrogen for Nutrient Management in the Stream (하천에서의 영양물질 관리를 위한 총질소 환경기준 설정에 관한 연구)

  • Kim, Hak Kwan;Jeong, Han;Bae, Seung Jong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.57 no.3
    • /
    • pp.121-127
    • /
    • 2015
  • The objective of this study is to suggest the water quality criteria of total nitrogen in order to efficiently manage the nutrient pollution in the stream. For this, correlations between water quality parameters were examined using the water quality data collected from the water quality monitoring network in the four rivers between 2003 and 2012. T-N showed positive correlations with T-P (0.636), COD (0.577), BOD (0.574), TOC (0.440), and SS (0.367). The statistical analysis including percentile analysis for the T-N and T-P concentrations was utilized to develop the water quality criteria of T-N. The feasibility of the suggested water quality criteria was evaluated by calculating the achievement rate to water quality target at the representative points in mid-watershed, then the draft water quality standard of T-N was suggested. The suggested water quality standard of T-N in the stream may be used to efficiently control the nutrient pollution in the public water body.

Conjunctive Use of SWAT and WASP Models for the Water Quality Prediction in a Rural Watershed (농촌유역 하천의 수질예측을 위한 SWAT모형과 WASP모형의 연계운영)

  • 권명준;권순국;홍성구
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.2
    • /
    • pp.116-125
    • /
    • 2003
  • Predictions of stream water quality require both estimation of pollutant loading from different sources and simulation of water quality processes in the stream. Nonpoint source pollution models are often employed for estimating pollutant loading in rural watersheds. In this study, a conjunctive application of SWAT model and WASP model was made and evaluated for its applicability based on the simulation results. Runoff and nutrient loading obtained from the SWAT model were used for generating input data for WASP model. The results showed that the simulated runoff was in good agreement with the observed data and indicated reasonable applicability. Loading for the water quality parameters predicted by WASP model also showed a reasonable agreement with the observed data. It is expected that stream water quality could be predicted by the coupled application of the two models, SWAT and WASP, in rural watersheds.

Development and Application of Water Quality Level Model (WQLM) for the Small Streams of Rural Watersheds with Discriminant Analysis (판별분석을 통한 농촌유역 소하천의 수질등급모형(WQLM) 개발 및 적용)

  • Kim, Jin-Ho;Choi, Chul-Mann;Ryu, Jong-Soo;Jung, Goo-Bok;Shin, Joung-Du;Han, Kuk-Heon;Lee, Jung-Taek;Kwun, Soon-Kuk
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.2
    • /
    • pp.260-265
    • /
    • 2007
  • This study was carried out to complement water quality standards and to establish new concept for water quality standards reflecting current state of water quality in small streams. By this purpose, discriminant analysis was performed and Water Quality Level Model (WQLM) was developed using the data such as EC, BOD, $COD_{Mn}$, SS, T-N, T-P, $NH_3-N$ in 224 agricultural streams. To give water quality level for water quality parameters, it divided into 20% respectively in the order of excellent water quality. On the basis of the lowest water quality level, water quality level of small streams is granted. As a result of it, number of stream corresponding to Level I was no, Level II was 2 streams, Level III was 22 streams, Level IV was 70 streams, and Level V was 130 streams. Average of water quality in each level was the highest in Level V. EC, SS, and T-N of 7 parameters were selected in variance concerned water quality level. By standardized canonical discriminant function coefficient, EC of three variances was the highest in 0.625 at the discriminant power. The next was T-N (0.509), SS (0.414). By discriminant function for water quality level, Level II was equal to $-2.973+19.376{\times}(EC)+0.647{\times}(T-N)+0.009{\times}(SS)$, Level III was equal to $-3.288+19.190{\times}(EC)+0.733{\times}(T-N)+0.041{\times}(SS)$, Level IV was equal to $-4.462+27.097{\times}(EC)+0.792{\times}(T-N)+0.053{\times}(SS)$, and Level V was equal to $-9.117+40.040{\times}(EC)+1.305{\times}(T-N)+0.111{\times}(SS)$. As a result of test at real agricultural watershed of Jeongan and Euidang in Gongju city, the fitness of WQLM was high to 88.78%. But, to get accomplished water quality assessment more exactly in agricultural streams, we had to concentrate and get vast data, and WQLM was modified and complemented continually.

Effect of Water Quality of Cooling Tower on Legionella pneumophila Disinfection Using Ru/Ti Electrode (냉각탑수 수질이 Ru/Ti 전극을 이용한 Legionella pneumophila 소독에 미치는 영향)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.17 no.6
    • /
    • pp.581-589
    • /
    • 2008
  • This study was carried out to evaluate the effect of water quality of cooling tower on Legionella pneumophila disinfection using Ru/Ti electrode. The influences of parameters such as pH, turbidity, $CaCO_3$ and TOC were investigated using laboratory scale batch reactor. Oxidants such as free Cl, $ClO_2,\;H_2O_2\;and\;O_3$ were measured. The results showed that all of the water quality parameters of cooling tower had deteriorated disinfection of Legionella pneumophila. When the turbidity, $CaCO_3$ and TOC was increased, oxidants which was generated during electrolysis was decreased. pH, free Cl, $ClO_2\;and\;H_2O_2$ concentration were decreased with the increase of pH, whereas $O_3$ concentration was increased with the increase of pH. The order of effect of water quality on the disinfection performance for Legionella pneumophila was turbidity > $CaCO_3$ > TOC > pH. To obtain the safety standard (1000 CFU/L), the simultaneous increase current and NaCl dosage was needed.