Effect of Parameters on the Two-Phase Flow Distribution Characteristics of Refrigerants in a Horizontal T-Junction  

Tae Sang-Jin (Graduate School, Sungkyunkwan University)
Cho Keumnam (School of Mechanical Engineering, Sungkyunkwan University)
Publication Information
Korean Journal of Air-Conditioning and Refrigeration Engineering / v.18, no.1, 2006 , pp. 31-37 More about this Journal
Abstract
The present study has been experimentally investigated the effect of geometric and operating parameters on the two-phase flow distribution of refrigerants in a horizontal T-junction. The operating parameters were the kind of refrigerants (R-22, R- l34a, and R-410A), saturated temperature, and the inlet mass flux and quality. The geometric parameters were the tube diameter and the tube diameter ratio. The measured data of refrigerants were compared with the values predicted using the models developed by several researchers for air/water or steani/water two-phase flow. Among the operating parameters, the inlet Quality was the most sensitive to the mass flow rate ratio. Between the geometric parameters, the tube diameter ratio was more sensitive than tube diameter.
Keywords
Two-phase flow; Flow distribution; Horizontal T-junction; Refrigerant;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Roberts, P. A., Azzopardi, B. J. and Hibberd, S., 1997, The split of horizontal annular flow at a T-junction, Chemical Engineering Science, Vol. 52, No. 20, pp. 3441-3453   DOI   ScienceOn
2 Moffat, R. J., 1985, Using uncertainty analysis in the planning of an experiment, Trans. of the ASME: J. of Fluid Engineering, Vol. 107, pp.173-182   DOI
3 Ballyk, J. D., Shoukri, M. and Chan, A. M. C., 1988, Steam-water annular flow in a horizontal dividing T-junction, Int. J. Multiphase Flow, Vol. 14, No. 3, pp. 265-285   DOI   ScienceOn
4 Shoham, O., Brill, JP. and Taitel, Y., 1987, Two-phase flow splitting in a tee junction - Experiment and modelling, Chemical Engineering Science, Vol. 42, No. 11, pp. 2667-2676   DOI   ScienceOn
5 Hart, J., Hamersma, P. J. and Fortuin, J. M. H., 1991, Phase distribution during gas-liquid flow through horizontal dividing junctions, Nuclear Engineering and Design, Vol. 126, pp. 293-312   DOI   ScienceOn
6 Azzopardi, B. J. and Whalley, P. B., 1982, The effect of flow patterns on two-phase flow in a T-junction, Int. J. Multiphase Flow, Vol. 8, pp. 491-507   DOI   ScienceOn
7 Hwang, S. T., Soliman, H. M. and Lahey, Jr., R. T., 1988, Phase separation in dividing two-phase flows, Int. J. Multiphase Flow, Vol. 14, No. 4, pp. 439-458   DOI   ScienceOn
8 Reimann, J. and Seeger, W., 1986, Two- phase flow in a T-junction with a horizontal inlet Part 2: Pressure Differences, Int. J. Multiphase Flow, Vol. 12, No. 4, pp.587-608   DOI   ScienceOn
9 Seeger, W., Reimann, J. and Muller, U., 1986, Two-phase flow in a T-junction with a horizontal inlet Part 1: Phase separation, Int. J. Multiphase Flow, Vol. 12, No. 4, pp. 575-585   DOI   ScienceOn