• Title/Summary/Keyword: Water quality monitoring

Search Result 1,052, Processing Time 0.034 seconds

Analysis of Microbiological Contamination in Cultivation and Distribution Stage of Melon

  • Park, Kyeong-Hun;Yun, Hye-Jeong;Kim, Won-Il;Kang, Jun-Won;Millner, Patricia D.;Micallef, Shirley A.;Kim, Byeong-Seok
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.46 no.6
    • /
    • pp.615-622
    • /
    • 2013
  • The purpose of this study was to evaluate microbial contamination of melons in Korea. A total of 123 samples including melon fruits, leaves, seeds, soils, and irrigation water were collected from farms and markets to detect total aerobic bacteria, coliform, Escherichia coli, and pathogenic bacteria such as Bacillus cereus, Listeria monocytogenes, Salmonella spp., and Staphylococcus aureus. Samples were collected from Iksan and Nonsan farms to monitor bacterial levels on pre-market melons. The total aerobic and coliform bacteria on melon cultivation were between 0.43 and 6.65 log CFU $g^{-1}$, and 0.67 and 2.91 log CFU $g^{-1}$, respectively. Bacillus cereus, a fecal coliform, was detected in soils and melon leaves from Iksan farm at 2.95, 0.73 log CFU $g^{-1}$, respectively, and in soils from Nonsan farm at 3.16 log CFU $g^{-1}$. Market melon samples were collected to assay bacterial load on melon being sold to consumers. The contamination levels of total aerobic bacteria in agricultural markets, big-box retailers, and traditional markets were 4.82, 3.94, 3.99 log CFU $g^{-1}$, respectively. The numbers of coliform in melon on the markets ranged from 0.09 to 0.49 log CFU $g^{-1}$. Listeria monocytogenes, Salmonella spp., and Staphylococcus aureus were not detected in any samples. The count of total aerobic bacteria on melon seeds ranged from 0.33 to 3.34 log CFU $g^{-1}$. This study found that irrigation water, soil, manure and various farm work activities including post-harvest processes were latent sources of microbial contamination. These results suggest that hygienic management and monitoring of soil, water, and agricultural material should be performed to reduce microbial contamination in melon production.

Analysis of Benthic Macroinvertebrate Community Structure and Stability in Major Inflow Streams of Lake Andong and Lake Imha (안동·임하호 주요 유입지천의 저서성 대형무척추동물 군집구조 및 군집안정성 분석)

  • You, Hyuk;Lee, Mi Jin;Seo, Eul Won;Lee, Jong Eun
    • Korean Journal of Environmental Biology
    • /
    • v.34 no.4
    • /
    • pp.320-328
    • /
    • 2016
  • This study was conducted to provide important basic information about effective management of the marine environment at major inflow streams in Lake Andong and Lake Imha. The investigation was conducted 8 times from May, 2015 (AD1, AD2, IH1, IH2) to September, 2016 (AD3, AD4, IH3, IH4), and 8 surveyed sites were selected at Lake Andong (4 sites) and Lake Imha (4 sites). The inquiry identified 114 species, $59,913.7inds.\;m^{-2}$ in Lake Andong and 112 species, $39,038.4inds.\;m^{-2}$ in Lake Imha. The results indicate that the number of species and individuals in Lake Andong is more than that in Lake Imha, because Lake Andong has a variety of riparian vegetation and a richness of organic materials. Community analysis at Lake Imha revealed a dominant index of 0.57 (${\pm}0.18$), a diversity index of 2.87 (${\pm}0.31$), an evenness index of 0.73 (${\pm}0.04$), and a richness index of 4.17 (${\pm}0.71$). The results of functional feeding group analysis showed that a high proportion of species and individuals are gathering collectors. The results of functional habitat group analysis showed that a high proportion of species and individuals are clingers. The result of a physico-chemical water assay and dissolved oxygen and electric conductivity tests revealed that these measures increased when the water temperature decreased. The result of Pearson's correlation analysis by biological factors and physico-chemical factors showed that species and electric conductivity are highly correlated with one another. Major inflow streams of Lake Andong and Lake Imha were exposed to various point pollution sources and non-point pollution sources. This implies a necessity for continuous monitoring of the aquatic ecosystems in order to effect systematic water quality management of Lake Andong and Lake Imha.

Application of Molecular Biological Technique for Development of Stability Indicator in Uncontrolled Landfill (불량매립지 안정화 지표 개발을 위한 분자생물학적 기술의 적용)

  • Park, Hyun-A;Han, Ji-Sun;Kim, Chang-Gyun;Lee, Jin-Young
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.2
    • /
    • pp.128-136
    • /
    • 2006
  • This study was conducted for developing the stability parameter in uncontrolled landfill by using a biomolecular investigation on the microbial community growing through leachate plume. Landfill J(which is in Cheonan) and landfill T(which is in Wonju) were chosen for this study among a total of 244 closed uncontrolled landfills. It addressed the genetic diversity of the microbial community in the leachate by 165 rDNA gene cloning using PCR and compared quantitative analysis of denitrifiers and methanotrophs with the conventional water quality parameters. From the BLAST search, genes of 47.6% in landfill J, and 32.5% in landfill T, respectively, showed more than 97% of the similarity where Proteobacteria phylum was most significantly observed. It showed that the numbers of denitrification genes, i.e. nirS gene and cnorB gene in the J site are 7 and 4 times higher than those in T site, which is well reflecting from a difference of site closure showing 7 and 13 years after being closed, respectively. In addition, the quantitative analysis on methane formation gene showed that J1 spot immediately bordering with the sources has the greatest number of methane formation bacteria, and it was decreased rapidly according to distribute toward the outer boundary of landfill. The comparative investigation between the number of genes, i.e. nirS gene, cnorB gene and MCR gene, md the conventional monitoring parameters, i.e. TOC, $NH_3-N,\;NO_3-N,\;NO_2-N,\;Cl^-$, alkalinity, addressed that more than 99% of the correlation was observed except for the $NO_3-N$. It was concluded that biomolecular investigation was well consistent with the conventional monitoring parameters to interpret their influences and stability made by leachate plume formed in downgradient around the uncontrolled sites.

Comparative Analysis of Nitrogen Concentration of Rainfall in South Korea for Nonpoint Source Pollution Model Application (비점오염모델 적용을 위한 우리나라 행정구역별 강수 중 질소농도 비교분석)

  • Choi, Dong Ho;Kim, Min-Kyeong;Hur, Seung-Oh;Hong, Sung-Chang;Choi, Soon-Kun
    • Korean Journal of Environmental Agriculture
    • /
    • v.37 no.3
    • /
    • pp.189-196
    • /
    • 2018
  • BACKGROUND: Water quality management of river requires quantification of pollutant loads and implementation of measures through monitoring study, but it requires labour and costs. Therefore, many researchers are performing nonpoint source pollution analysis using computer models. However, calibration of model parameters needs observed data. Nitrogen concentration in rainfall is one of the factors to be considered when estimating the pollutant loads through application of the nonpoint source pollution model, but the default value provided by the model is used when there are no observed data. Therefore, this study aims to provide the representative nitrogen concentration of the rainfall for the administrative district ensuring rational modeling and reliable results. METHODS AND RESULTS: In this study, rainfall monitoring data from June 2015 to December 2017 were used to determine the nitrogen concentration in rainfall for each administrative district. Range of the $NO_3{^-}$ and $NH_4{^+}$ concentrations were 0.41~6.05 mg/L, 0.39~2.27 mg/L, respectively, and T-N concentration was 0.80~7.71 mg/L. Furthermore, the national average of T-N concentration in this study was $2.84{\pm}1.42mg/L$, which was similar to the national average of T-N 3.03 mg/L presented by the Ministry of Environment in 2015. Therefore, the nitrogen concentrations suggested in this study can be considered to be resonable values. CONCLUSION: The nitrogen concentrations estimated in this study showed regional differences. Therefore, when estimating the pollutant loads through application of the nonpoint source pollution model, resonable parameter estimation of nitrogen concentration in rainfall is possible by reflecting the regional characteristics.

Fate Analysis and Impact Assessment for Vehicle Polycyclic Aromatic Hydrocarbons (PAHs) Emitted from Metropolitan City Using Multimedia Fugacity Model (다매체거동모델을 이용한 대도시 자동차 배출 Polycyclic Aromatic Hydrocarbons (PAHs) 거동 해석 및 영향평가)

  • Rhee, Gahee;Hwangbo, Soonho;Yoo, ChangKyoo
    • Korean Chemical Engineering Research
    • /
    • v.56 no.4
    • /
    • pp.479-495
    • /
    • 2018
  • This study was carried out to research the multimedia fate modeling, concentration distribution and impact assessment of polycyclic aromatic hydrocarbons (PAHs) emitted from automobiles, which are known as carcinogenic and mutation chemicals. The amount of emissions of PAHs was determined based on the census data of automobiles at a target S-city and emission factors of PAHs, where multimedia fugacity modeling was conducted by the restriction of PAHs transfer between air-soil at the impervious area. PAHs' Concentrations and their distributions at several environmental media were predicted by multimedia fugacity model (level III). The residual amounts and the distributions of PAHs through mass transfer of PAHs between environment media were used to assess the health risk of PAHs at unsteady state (level IV), where the sensitivity analyses of the model parameter of each variable were conducted based on Monte Carlo simulation. The experimental result at S-city showed that Fluoranthene among PAHs substances are the highest residual concentrations (60%, 53%, 32% and 34%) at all mediums (atmospheric, water, soil, sediment), respectively, where most of the PAHs were highly accumulated in the sediment media (more than 80%). A result of PAHs concentration changes in S-city over the past 34 years identified that PAHs emissions from all environmental media increased from 1983 to 2005 and decreased until 2016, where the emission of heavy-duty vehicle including truck revealed the largest contribution to the automotive emissions of PAHs at all environment media. The PAHs concentrations in soil and water for the last 34 years showed the less value than the legal standards of PAHs, but the PAHs in air exceeded the air quality standards from 1996 to 2016. The result of this study is expected to contribute the effective management and monitoring of toxic chemicals of PAHs at various environment media of Metropolitan city.

Monitoring of arsenic and arsenic species in fish collagen in Korea (국내 유통 어류 콜라겐의 총비소 및 비소화학종 함량 모니터링)

  • Yeo-Jae Shin;Mi-Ra Jang;Eun-Hee Kim;Yun-Hee Kim;Min-Jung Kim;Min-Jung Kim;Jae-Hoon Cha;Mi-Hyun Choi;Seok-Ju Cho;In-Sook Hwang;Yong-Seung Shin
    • Analytical Science and Technology
    • /
    • v.36 no.3
    • /
    • pp.135-142
    • /
    • 2023
  • The total arsenic and 6 arsenic species were investigated in 56 fish collagen products using ICP-MS (Inductively coupled plasma-mass spectrometer) and HPLC-ICP-MS(High performance liquid chromatography-Inductively coupled plasma-mass spectrometer). The mean concentrations of total arsenic and arsenic species were 40.103±81.133 ㎍/kg (N.D.~586.686) and 30.070±50.378 ㎍/kg (N.D.~313.871), respectively. The mean concentration of inorganic arsenic was 24.610±32.706 ㎍/kg (N.D.~129.331), and the As(V) (Arsenate) was the most dominant. The standards and specifications of arsenic have not been established for fish collagen products. Our study presents that arsenic levels are relatively safe compared with not only previous studies but also domestic and international standards. However, in one sample, the total arsenic concentration was 586.686 ㎍/kg, showing the inorganic was 8.119 ㎍/kg, and the DMA was 305.752 ㎍/kg, which was high than the Canadian standard for organic arsenic. In conclusion, it is necessary to monitor arsenic levels consistently and establish standards and specifications of arsenic in fish collagen products to assure consumer safety.

A Performance Comparison of Land-Based Floating Debris Detection Based on Deep Learning and Its Field Applications (딥러닝 기반 육상기인 부유쓰레기 탐지 모델 성능 비교 및 현장 적용성 평가)

  • Suho Bak;Seon Woong Jang;Heung-Min Kim;Tak-Young Kim;Geon Hui Ye
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.2
    • /
    • pp.193-205
    • /
    • 2023
  • A large amount of floating debris from land-based sources during heavy rainfall has negative social, economic, and environmental impacts, but there is a lack of monitoring systems for floating debris accumulation areas and amounts. With the recent development of artificial intelligence technology, there is a need to quickly and efficiently study large areas of water systems using drone imagery and deep learning-based object detection models. In this study, we acquired various images as well as drone images and trained with You Only Look Once (YOLO)v5s and the recently developed YOLO7 and YOLOv8s to compare the performance of each model to propose an efficient detection technique for land-based floating debris. The qualitative performance evaluation of each model showed that all three models are good at detecting floating debris under normal circumstances, but the YOLOv8s model missed or duplicated objects when the image was overexposed or the water surface was highly reflective of sunlight. The quantitative performance evaluation showed that YOLOv7 had the best performance with a mean Average Precision (intersection over union, IoU 0.5) of 0.940, which was better than YOLOv5s (0.922) and YOLOv8s (0.922). As a result of generating distortion in the color and high-frequency components to compare the performance of models according to data quality, the performance degradation of the YOLOv8s model was the most obvious, and the YOLOv7 model showed the lowest performance degradation. This study confirms that the YOLOv7 model is more robust than the YOLOv5s and YOLOv8s models in detecting land-based floating debris. The deep learning-based floating debris detection technique proposed in this study can identify the spatial distribution of floating debris by category, which can contribute to the planning of future cleanup work.

Relationship between a Dense Bloom of Cyanobacterium Anabaena spp. and Rainfalls in the North Han River System of South Korea (북한강 수계의 남조 Anabaena 대발생과 강우의 관계)

  • Byun, Jeong-Hwan;Cho, In-Hwan;Hwang, Soon-Jin;Park, Myung-Hwan;Byeon, Myeong-Seop;Kim, Baik-Ho
    • Korean Journal of Ecology and Environment
    • /
    • v.47 no.2
    • /
    • pp.116-126
    • /
    • 2014
  • To evaluate the relationship between dynamics of Cyanobacterial bloom and rainfalls, a monthly monitoring of water quality and phytoplankton from the three serial lakes (Lake Ui-am, Lake Chung-pyeong and Lake Pal-dang) in the North Han River System were examined 12 times from May 2012 to March 2013. A dense bloom of cyanobacterium Anabaena spp., was occurred over three lakes in the summer season of 2012. In Lake Ui-am, the Anabaena population appeared in June, showed a peak in July (43,850 cells $mL^{-1}$) and disappeared in November 2012. In Lake Chung-pyeong and Lake Pal-dang, Anabaena population commonly appeared in July, showed the peaks (31,648 cells $mL^{-1}$ and 7,136 cells $mL^{-1}$, respectively) in August, and entirely disappeared in September 2012. Over the three lakes, the phytoplankton community was commonly dominated by diatoms before Monsoon, cyanobacteria during Monsoon, and diatoms after Monsoon, respectively, indicating a Monsoon-dependent succession. A correlation analysis revealed that dynamics of Anabaena population was strongly related with rainfall (r=0.72, r=0.83, r=0.88, P<0.01 for three lakes), and partly with nutrients, inflow and outflow of lakes. Therefore, this study indicates that the outbreak and destruction of Anabaena bloom in North Han River System between 2012 and 2013 was impacted by rainfalls. However, a high density of cyanobacteria in Lake Ui-am remained after Monsoon, and thus, may paroduce bad-order and toxins from phytoplankton.

A Study on the Pavement Status and Improvement Directions of the Viewing Road in Royal Tombs of Joseon Dynasty (조선 왕릉 관람로의 포장현황과 개선방향)

  • Paek, Chong-Chul;Hong, Youn-Soon
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.37 no.2
    • /
    • pp.66-73
    • /
    • 2019
  • The Royal Tomb of the Joseon Dynasty, which was listed as a UNESCO World Heritage site in 2009, is a cultural resource recognized for its 'outstanding universal value' around the world. The royal tomb of Joseon has been managed with an emphasis on the preservation of cultural assets since it was designated as a historical site in the 1970s, but it has received many visitors as a valuable historical and cultural resource and haven that connects the past and the present in today's bustling city. In order to investigate and analyze the current status of pavements in the royal palace in terms of quality and quantity, and to suggest the direction of improvement, this study conducted a complete survey of 53 royal palace viewing roads in 18 regions, and the results are as follows. First of all, problems are found in both the early Masato pavement of the creation, which was introduced with an emphasis on the preservation and protection of cultural assets, and the hardening pavement(KAP), which began to be used in the 1990s for the convenience of maintenance. In other words, the Masato pavement used to create a more environmentally friendly atmosphere of the Joseon royal tombs is showing a high percentage of use, but it lacks support for walking activities, such as the slippage of the pavement and water pooling during the rainy season or during the ice season. Also, hardening pavement introduced for convenience of maintenance, such as the movement of repair vehicles, is not functioning properly as it is damaged by physical deformation after construction. In addition, in awe zones such as parking lots, although the first image of the Joseon royal tombs is determined, the formation of the functional landscape centered on the carriageway does not harmonize with the traditional landscape, and, because of its lack of walking and environment-friendly features, there is a need for improvement, such as the experimental introduction of relevant pavement materials developed afterwards and continuous monitoring.

Evaluation of Cryptosporidiurn Disinfection by Ozone and Ultraviolet Irradiation Using Viability and Infectivity Assays (크립토스포리디움의 활성/감염성 판별법을 이용한 오존 및 자외선 소독능 평가)

  • Park Sang-Jung;Cho Min;Yoon Je-Yong;Jun Yong-Sung;Rim Yeon-Taek;Jin Ing-Nyol;Chung Hyen-Mi
    • Journal of Life Science
    • /
    • v.16 no.3 s.76
    • /
    • pp.534-539
    • /
    • 2006
  • In the ozone disinfection unit process of a piston type batch reactor with continuous ozone analysis using a flow injection analysis (FIA) system, the CT values for 1 log inactivation of Cryptosporidium parvum by viability assays of DAPI/PI and excystation were $1.8{\sim}2.2\;mg/L{\cdot}min$ at $25^{\circ}C$ and $9.1mg/L{\cdot}min$ at $5^{\circ}C$, respectively. At the low temperature, ozone requirement rises $4{\sim}5$ times higher in order to achieve the same level of disinfection at room temperature. In a 40 L scale pilot plant with continuous flow and constant 5 minutes retention time, disinfection effects were evaluated using excystation, DAPI/PI, and cell infection method at the same time. About 0.2 log inactivation of Cryptosporidium by DAPI/PI and excystation assay, and 1.2 log inactivation by cell infectivity assay were estimated, respectively, at the CT value of about $8mg/L{\cdot}min$. The difference between DAPI/PI and excystation assay was not significant in evaluating CT values of Cryptosporidium by ozone in both experiment of the piston and the pilot reactors. However, there was significant difference between viability assay based on the intact cell wall structure and function and infectivity assay based on the developing oocysts to sporozoites and merozoites in the pilot study. The stage of development should be more sensitive to ozone oxidation than cell wall intactness of oocysts. The difference of CT values estimated by viability assay between two studies may partly come from underestimation of the residual ozone concentration due to the manual monitoring in the pilot study, or the difference of the reactor scale (50 mL vs 40 L) and types (batch vs continuous). Adequate If value to disinfect 1 and 2 log scale of Cryptosporidium in UV irradiation process was 25 $mWs/cm^2$ and 50 $mWs/cm^2$, respectively, at $25^{\circ}C$ by DAPI/PI. At $5^{\circ}C$, 40 $mWs/cm^2$ was required for disinfecting 1 log Cryptosporidium, and 80 $mWs/cm^2$ for disinfecting 2 log Cryptosporidium. It was thought that about 60% increase of If value requirement to compensate for the $20^{\circ}C$ decrease in temperature was due to the low voltage low output lamp letting weaker UV rays occur at lower temperatures.