• Title/Summary/Keyword: Water quality measuring system

Search Result 74, Processing Time 0.03 seconds

Implementation and Analysis Performance of CCM-UW based AES, ARIA Blockcipher for Underwater Environment (수중무선통신 환경에 적합한 AES, ARIA 블록암호 기반 CCM-UW 구현 및 성능 분석)

  • Lee, Jae-Hoon;Park, Minha;Yun, Nam-Yeol;Yi, Okyeon;Park, Soo-Hyun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.05a
    • /
    • pp.115-118
    • /
    • 2014
  • Underwater Wireless Communication System can be useful for research of quality of water, ocean resources exploration, analysis ocean environment and so on. However, there exist security threats including data loss, data forgery, and another variety of security threats, because of characteristics of water, various geographical factors, intended attack, etc. To solve these problem, in this paper, we propose a CCM-UW mode of operation modified form of CCM mode of operation, providing data confidentiality, integrity, origin authentication and anti-attack prevent, for the Underwater Wireless Communication System. By implementing CCM-UW in MACA protocol(Underwater Wireless Communication MAC Protocol) and measuring speed of communication, we confirm the applicability of the security and analyze the communication environment impact.

  • PDF

Intelligent Controller for Optimal Coagulant Dosage Rate in Water Treatment Process (정수장 약품 최적 주입률 결정을 위한 지능형 제어기 개발)

  • Lee, Ho-Hyun;Shin, Gang-Wook;Hong, Sung-Taek;Chun, Myung-Geun
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.25 no.4
    • /
    • pp.369-376
    • /
    • 2015
  • Chemicals are injected in order to remove a variety of organic substances contained in the water purification plant influent. It can be determined with measuring sedimentation turbidity 4~7 hours later, whether the chemical dosage rate is proper or not, which make the real-time feedback control impossible. In addition, manual operation in accordance with the Jar-Test carried out in the laboratory and the operator's experience may cause the experimental and human error by the changes of organic characteristics and water quality. Especially at night ad weekend, the rate have been determined only by the operator judgment owing to environment engineer's absence. Therefore, the decision of optimal chemical dosage rate using proposed intelligent control algorithm is expected to result in real-time injection and cost reduction.

Classification of the Algal Monitoring Points by Histogram Analysis of Chlorophyll-a (Chlorophyll-a의 히스토그램 분석을 통한 녹조발생 우심지역 분류)

  • Lee, Saeromi;Ahn, Chang Hyuk;Park, Jae Roh
    • Journal of Environmental Impact Assessment
    • /
    • v.29 no.1
    • /
    • pp.37-44
    • /
    • 2020
  • In this study, we analyzed the value of Chl-a by histogram to classify the points where algal management is required. The degree of algal bloom by point was analyzed using the ogive curve, and the algal control points were classified into three stages according to the shape of the frequency distribution table. Of the four major rivers, low concentration of Chl-a appeared most frequently in the Han River, while the high concentration of Chl-a was frequently found at the points of the Geum and the Yeongsan Rivers. In the case of the Han River, no apprehensive areas were found thatrequire intensive management, while most points on the Geum and the Yeongsan Rivers required algal management. Finally, the Nakdong River basin was identified as points requiring algal management from the mid to downstream. The results of this study have confirmation of the possibility that the frequency distribution could be used as a supplementary indicator to express the algal bloom.

Development of a polystyrene phantom for quality assurance of a Gamma Knife®

  • Yona Choi;Kook Jin Chun;Jungbae Bahng;Sang Hyoun Choi;Gyu Seok Cho;Tae Hoon Kim;Hye Jeong Yang;Yeong Chan Seo;Hyun-Tai Chung
    • Nuclear Engineering and Technology
    • /
    • v.55 no.8
    • /
    • pp.2935-2940
    • /
    • 2023
  • A polystyrene phantom was developed following the guidance of the International Atomic Energy Association (IAEA) for gamma knife (GK) quality assurance. Its performance was assessed by measuring the absorbed dose rate to water and dose distributions. The phantom was made of polystyrene, which has an electron density (1.0156) similar to that of water. The phantom included one outer phantom and four inner phantoms. Two inner phantoms held PTW T31010 and Exradin A16 ion chambers. One inner phantom held a film in the XY plane of the Leksell coordinate system, and another inner phantom held a film in the YZ or ZX planes. The absorbed dose rate to water and beam profiles of the machine-specific reference (msr) field, namely, the 16 mm collimator field of a GK PerfexionTM or IconTM, were measured at seven GK sites. The measured results were compared to those of an IAEA-recommended solid water (SW) phantom. The radius of the polystyrene phantom was determined to be 7.88 cm by converting the electron density of the plastic, considering a water depth of 8 g/cm2. The absorbed dose rates to water measured in both phantoms differed from the treatment planning program by less than 1.1%. Before msr correction, the PTW T31010 dose rates (PTW Freiberg GmbH, New York, NY, USA) in the polystyrene phantom were 0.70 (0.29)% higher on average than those in the SW phantom. The Exradin A16 (Standard Imaging, Middleton, WI, USA) dose rates were 0.76 (0.32)% higher in the polystyrene phantom. After msr correction factors were applied, there were no statistically significant differences in the A16 dose rates measured in the two phantoms; however, the T31010 dose rates were 0.72 (0.29)% higher in the polystyrene phantom. When the full widths at half maximum and penumbras of the msr field were compared, no significant differences between the two phantoms were observed, except for the penumbra in the Y-axis. However, the difference in the penumbra was smaller than variations among different sites. A polystyrene phantom developed for gamma knife dosimetry showed dosimetric performance comparable to that of a commercial SW phantom. In addition to its cost effectiveness, the polystyrene phantom removes air space around the detector. Additional simulations of the msr correction factors of the polystyrene phantom should be performed.

An experimental study on the injection and spray characteristics of butanol (부탄올의 분사 및 분무특성에 관한 실험적 연구)

  • JEONG, Tak-Su;WANG, Woo-Gyeong;KIM, Sang-Am
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.53 no.1
    • /
    • pp.89-97
    • /
    • 2017
  • Butanol has an ability to improve the ignition quality due to its lower latent heat of vaporization; it has an advantage to reduce a volume of a fuel tank because its energy density is higher than that of ethanol. Also, butanol-diesel oil blending quality is good because butanol has an effect to prevent the phase-separation between two fuels. Even if the blended oil contains water, it can reduce the corrosion of the fuel line. Thus, it is possible to use butanol-diesel oil blended fuel in diesel engine without modification, and it may reduce the environment pollution due to NOx and particulate and the consumption of diesel oil. Therefore, some studies are being advanced whether butanol is adequate as an alternative fuel for diesel engines, and the results of the combustion and exhaust gas emission characteristics are being presented. Though the injection and spray characteristics of butanol are more important in diesel combustion, the has not yet dealt with the matter. In this study, the influence in which differences of physical properties between butanol and diesel oil may affect the injection and spray characteristics such as injection rate, penetration, spray cone angle, spray velocity and process of spray development were examined by using CRDI system, injection rate measuring device and spray visualization system. The results exhibited that the injection and macroscopic spray characteristics of two fuels were nearly the same.

Characteristics of dose distribution for virtual wedge (가변형 쐐기필터의 선량분포에 관한 특성)

  • 김부길;김진기
    • Progress in Medical Physics
    • /
    • v.12 no.2
    • /
    • pp.125-131
    • /
    • 2001
  • We was investigate the dosimetric characteristics of the virtual wedge and it compared to the conventional fixed wedge. Also we was evaluate the quality factor of the experimental multi-channel dosimetry system for virtual wedge. Recently virtual wedge technique and wedge fraction methods are available through the computer controlled asymmetric collimator or the independent jaw in medical linear accelerator for radiation therapy. The dosimetric characteristics are interpreted by radiation field analyzer RFA-7 system and PTW-UNIDOS system. Experimental multi-channel dosimetry system for virtual wedge was consists of the electrometer, the solid detector and array phantom. The solid detectors were constructed using commercially diodes for the assessment of quality assurance in radiotherapy. And it was used for the point dose measuring and field size scanning. The semiconductor detector and ion chamber were positioned at a dmax, 5 cm, 10 cm, 20 cm depth and its specific ratio was determined using a scanning data. Wedge angles in fixed and virtual type are compared with measurements in water phantom and it is shown that the wedge angle 15$^{\circ}$, 30$^{\circ}$, 45$^{\circ}$were agree within 1$^{\circ}$ degree in 6, 10 MV photon beams. In PDD and beam flatness, experimental multi-channel disimetry system was capable of reproduceing the measured values usually to within $\pm$2.1% the statistical uncertainties of the data. It was used to describe dosimetric characteristics of virtual wedge in clinical photon beams. Also we was evaluate optimal use of the virtual wedge and improve the quality factor of the experimental multi-channel dosimetry system for virtual wedge.

  • PDF

The History and Development of the Marine Environment QA/QC (Quality Assurance/Quality Control) Management System (해양환경 정도관리제도 운영에 대한 고찰)

  • PARK, MI-OK;PARK, JUN-KUN;KIM, SEONG-GIL;KIM, SEONG-SOO
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.26 no.3
    • /
    • pp.185-200
    • /
    • 2021
  • The Marine Environment QA/QC management system has been operated since 2010 to secure the reliability of data and improve the analysis capabilities of measurement and analysis institutions. From 2010 to 2020, the cumulative number of measurement and analysis institutions participated in the QA/QC management system was 266. And the number of certificates issued by the ministry of oceans and fisheries is 182. A total of 32 reference materials for proficiency testing and interlaboratory comparisons have been developed. They were first developed focusing on items (Nutrients, COD) commonly analyzed in marine environmental measuring network, marine pollution impact surveys, sea area utilization impact assessment, deepsea water surveys, and information network on fishing ground environments. In addition, it is time to expand the filed of the QA/QC management system, such as seawater temperature, salinity, PCBs and PAHs in sediments, which are mainly analyzed in most monitoring programs. On-site assessment has been conducted for 162 laboratories according to ISO/IEC 17025 to evaluate their conformity of the quality management system and deficiency. In terms of management and technology requirements, about 4.2% of organizations showed insufficient division of duties among employees 8.7% of them revealed the lack of employee training. By test item, about 6.3% of organizations showed the lack of standard substance management and the state of the cleaning glassware was pointed out in about 5.4% of them. The QA/QC management system should be continuously supplemented by identifying the causes of nonconformities and area for improvement.

The Evaluation for Attenuation Map using Low Dose in PET/CT System (PET/CT 시스템에서 감쇠지도를 만들기 위한 저선량 CT 평가)

  • Nam, So-Ra;Cho, Hyo-Min;Jung, Ji-Young;Lee, Chang-Lae;Lim, Han-Sang;Park, Hoon-Hee;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.18 no.3
    • /
    • pp.134-138
    • /
    • 2007
  • The current PET/CT system with high quality CT images not only increases diagnostic value by providing anatomic localization, but also shortens the acquisition time for attenuation correction than primary PET system. All commercially available PET/CT system uses the CT scan for attenuation correction instead of the transmission scan using radioactive source such as $^{137}Cs,\;^{68}Ge$. However the CT scan may substantially increase the patient dose. The purpose of this study was to evaluate quality of PET images reconstructed by CT attenuation map using various tube currents. in this study, images were acquired for 3D Hoffman brain phantom and cylindrical phantom using GE DSTe PET/CT system. The emission data were acquired for 10 min using phantoms after injecting 44.03 MBq of $^{18}F-FDG$. The CT images for attenuation map were acquired by changing tube current from 10 mA to 95 mA with fixed exposure time of 8 sec and fixed tube voltage of 140 kVp. The PET images were reconstructed using these CT attenuation maps. Image quality of CT images was evaluated by measuring SD (standard deviation) of cylindrical phantom which was filled with water and $^{18}F-FDG$ solution. The PET images were evaluated by measuring the activity ratio between gray matter and white matter in Hoffman phantom images. SDs of CT images decrease by increasing tube current. When PET images were reconstructed using CT attenuation maps with various tube currents, the activity ratios between gray matter and white matter of PET images were almost same. These results indicated that the quality of the PET images using low dose CT data were comparable to the PET images using general dose CT data. Therefore, the use of low dose CT is recommended than the use of general dose CT, when the diagnostic high quality CT is not required. Further studies may need to be performed for other system, since this study is limited to the GE DSTe system used in this study.

  • PDF

A benchmarking of electricity industry for improving the integrated water resources management (IWRM) policy (통합물관리 정책실현을 위한 전력산업 벤치마킹 연구)

  • Kim, Dong Hyun;Kim, Taesoon;Jung, Heoncheol;Jeong, Eunsung;Lee, Seung Oh;Jung, Changsam
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.spc1
    • /
    • pp.785-795
    • /
    • 2020
  • Recently, the integrated management of the quantity and quality of water was been derived by the Ministry of Environment in Korea. This reconstruction in the national government organization can be recognized as the major politic measure. For this IWRM (Integrated Water Resources Management), it is necessary to be able to fairly distribute, operate and manage water resources in a situation where related techniques are needed to fully support, such as measuring exactly the demand and supply of water resources. The reason why IWRM is difficult, despite the development of related technologies, is because the management entities are highly diverse and their interests are much complicated. Thus, this study is tried to suggest specific improvement for current policies by benchmarking the KPX (Korea Power Exchange). In the field of water management as similar to the electric industry, there is an essential need for a working-level organization that can manage, control, monitor, and regulate water resources with practical and plenipotentiary control like the non-profit organization, KPX. Such time has come for decisive policy changes through benchmarking the structure, system, productivity, and challenges of the electricity industry in the water policy.

Analysis of Monitoring Characteristics of Small Stream for TMDL (오염총량관리를 위한 소하천 모니터링 자료의 특성 분석)

  • Ha, Don-Woo;Park, Seung-Ho;Joo, Sungmin;Lee, Gi-Soon;Baek, Jong-Hun;Jung, Kang-Young;Lee, Youngjea;Kim, Kyunghyun;Kim, Young-Suk
    • Journal of the Korean Society for Environmental Technology
    • /
    • v.19 no.6
    • /
    • pp.503-513
    • /
    • 2018
  • In order to continuous watershed management and improve water quality at Yeong-san river system, we analyzed and evaluated data on the monitoring of small stream in city and county boundaries within the watershed. In-period monitoring is estimated to be more frequent in the second quarter than the first quarter, so it should be considered when evaluating the target water quality by setting the target water quality. A small stream in the Yeong-san river system has higher concentration in the downstream area than the upstream area. As a result of calculating the load of the measuring point, Y.b B3(Pungyeongjeongcheon) and Y.b E1(Sampocheon) were high. The result of correlation analysis by monitoring point in order to evaluate the correlation between BOD and T-P items, BOD was highly correlated with COD and TOC, and was affected by emission of pollutants related to organic matter. T-P was highly correlated with SS and COD, and was affected by rainfall. This study will provide basic data and direction for designing efficient and scientific method for water quality management by analyzing accumulated water quality data by conducting long-term monitoring.