• Title/Summary/Keyword: Water quality analyze

Search Result 580, Processing Time 0.029 seconds

Information and communication system for integrated management of water resources building measures (수자원 통합관리를 위한 정보통신시스템 구축방안)

  • Yu, Se-Hwan;Jang, Dong-bae
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.05a
    • /
    • pp.807-809
    • /
    • 2014
  • Individual dam water management is the comprehensive management of all water-based analyzes, quantity, quality, and comprehensive disaster management as a way to analyze and change. K-water is mainly the four river basins, and multipurpose dams and integrated water management is realized, and such information and communication system for integrated management of water resources is also a user-centered development, dam management, so that you can perform and built electronically be. The information communication system is configured to manage the operation of the control system of the equipment controlling system lower sensor and based on data collected from a field to store information, and to control the remote equipment capabilities. In this paper, the integrated management of water sector bodeung dam Information and Communication System for the best ways to learn about the system's security measures and systems to evaluate for weaknesses.

  • PDF

Evaluation of Operational Options of Wastewater Treatment Using EQPS Models (EQPS 모델을 이용한 하수처리장 운전 평가)

  • Yoo, Hosik;Ahn, Seyoung
    • Journal of the Korean Society of Urban Environment
    • /
    • v.18 no.4
    • /
    • pp.401-408
    • /
    • 2018
  • EQPS (Effluent Quality Prediction System, Dynamita, France) was applied to analyze the appropriateness of the design of a bioreactor in A sewage treatment plant. A sewage treatment plant was designed by setting the design concentration of the secondary clarifier effluent to total nitrogen and total phosphorus, 10 mg/L and 1.8 mg/L, respectively, in order to comply with the target water quality at the level of the hydrophilic water. The retention time of the 4-stage BNR reactor was 9.6 hours, which was 0.5 for the pre-anoxic tank, 1.0 for the anaerobic tank, 2.9 for the anoxic tank, and 5.2 hours for the aerobic tank. As a result of the modeling of the winter season, the retention time of the anaerobic tank was increased by 0.2 hours in order to satisfy the target water quality of the hydrophilic water level. The default coefficients of the one step nitrification denitrification model proposed by the software manufacturer were used to exclude distortion of the modeling results. Since the process modeling generally presents optimal conditions, the retention time of the 4-stage BNR should be increased to 9.8 hours considering the bioreactor margin. The accurate use of process modeling in the design stage of the sewage treatment plant is a way to ensure the stability of the treatment performance and efficiency after construction of the sewage treatment plant.

Analytical Evaluation of Influent Depending on the Occurrence of Rainfall by Case Study of Wastewater Treatment Facility (하수처리시설 사례 별 강우발생 유무에 따른 유입수 분석 평가)

  • Choi, Langkyu;Chung, Jin Do
    • Journal of Korean Society of Disaster and Security
    • /
    • v.12 no.3
    • /
    • pp.35-49
    • /
    • 2019
  • Currently in 2018, Korea has over 600 operating sewage disposal facilities. The law requires a sewage treatment plant to treat 500 tons or more of water per day, and a small-decentralized sewage treatment facility in a community to treat 50 tons or more to less than 500 tons of water per day. However, most facilities fulfill neither the quantity nor the quality requirements from the original design for such reasons as inflow of rainwater and ground water due to deterioration of pipelines and unauthorized input of wastewater in the pipelines. The research has selected 2 representative cases among the technical diagnosif sewage pipelines in many regions within the country to use it as the baseline of: hourly flowrate and BOD water quality analysis in both clear and rainy days, proper plant operation through inflow rate and ratio calculation, and diagnostic evaluation for deterioration of the pipelines and their accessary structures. This also suggests facilities that treats 500 tons or more of inflow per day to sample and analyze the water hourly for 24 hours once a week in both clear weather and rainy weather considering the influence of rainfall on a regular basis.

A Study on the Change of Current in the Vicinity of Mokpo Harbor and Its Impact on Ship Operation due to the Discharge through Yongsan River Estuary Weir and Yongam-Kumho Sea Dike (영산강 하구둑 및 영암-금호방조제의 방류에 의한 목포항 주변수역의 유동변화 및 선박운용에 미치는 영향에 관한 연구)

  • 정대득;이중우;국승기
    • Journal of Korean Port Research
    • /
    • v.13 no.1
    • /
    • pp.133-146
    • /
    • 1999
  • Mokpo coastal area is connected to the adjacent a long river and two large basins. It is essential for port planning coastal zone management and environmental impact study to analyze the data related to the ship operation and variation of current and water quality due to the development of water area including dredging reclamation and estuary barrage. The Yongsan river estuary weir and Yongam-Kumho basins discharge much of water through water gates for the purpose of flood control and prohibit salt intrusion at the inland fresh water area. To meet this purpose discharge through the gates have been done at the period of maximum water level difference between inner river and sea level. This discharged water may cause the changes of current pattern and other environmental influences in the vicinity and inner area of semi-closed Mokpo harbor. In this study ADI method is applied to the governing equation for the analysis of the changes on current pattern due to discharged water. As the results of this study it is known that the discharging operation causes many changes including the increase of current velocity at the front water area at piers approaching passage and anchorages. Discussion made on the point of problems such as restricted maneuverability and the safety of morred vessels at pier and anchorage. To minimize this influence the linked gate operation discharging warning system and laternative mooring system are recommended.

  • PDF

Analyzing the Effect of an Extreme Turbidity Flow Event on the Dam Reservoirs in North Han River Basin (북한강 수계 대규모 탁수사상 발생에 의한 댐 저수지의 탁수 영향 분석)

  • Park, Hyung-Seok;Chung, Se-Woong;Choung, Sun-a
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.3
    • /
    • pp.282-290
    • /
    • 2017
  • A long-term resuspension of small particles, called persistent turbidity, is one of the most important water quality concerns in the dam reservoirs system located in North Han River. Persistent turbidity may incur aesthetic nuisance and harmful effect on the ecosystem health, in addition to elevated water treatment costs for the drinking water supply to the Seoul metropolitan area. These sufferings have been more intensified as the strength and frequency of rainfall events increase by climate change in the basin. This study was to analyze the effect of an extreme turbidity flow event that occurred in 2006 on the serial reservoirs system (Soyang-Uiam-Cheongpyung-Paldang) in North Han River. The CE-QUAL-W2 model was set up and calibrated for the river and reservoirs system using the field data obtained in 2006 and 2007. The results showed that Soyang Reservoir released turbid water, which was classified as the TSS concentration is greater than 25 mg/L, for 334 days with peak TSS of 264.1 mg/L after the extreme flood event (592.7 mm) occurred between July 10 and 18 of 2006. The turbid water departed from Soyang Reservoir reached at the most downstream Paldang Reservoir after about 20 days and sustained for 41 days, which was validated with water treatment plant data. Since the released water from Soyang Reservoir had low water temperature and high TSS, an underflow formed in the downstream reservoirs and vertically mixed at Paldang Reservoir due to dilution by the sufficient inflow from South Han River.

Spatial and Temporal Variability of Water Quality in Geum-River Watershed and Their Influences by Landuse Pattern (금강 수계의 시.공간적 수질특성과 토지이용도의 영향)

  • Han, Jeong-Ho;Bae, Young-Ju;An, Kwang-Guk
    • Korean Journal of Ecology and Environment
    • /
    • v.43 no.3
    • /
    • pp.385-399
    • /
    • 2010
  • The objective of this study was to analyze long term temporal trends of water chemistry and spatial heterogeneity for 83 sampling sites of Geum-River watershed using water quality dataset during 2003~2007 (obtained from the Ministry of Environment, Korea). The water quality, based on multi-parameters of temperature, dissolved oxygen (DO), biochemical oxygen demand (BOD), chemical oxygen demand (COD), suspended solids (SS), total nitrogen (TN), total phosphorus (TP), and electric conductivity (EC), largely varied depending on the landuse patterns, years and seasons. The watershed was classified into three different landuse types: forest stream (Fo), agricultural stream (Ag), and urban stream (Ur). Largest seasonal variabilities in most parameters occurred during the two months of July to August and these were closely associated with large spate of summer monsoon rain. Conductivity, used as a key indicator for an ionic dilution during rainy season, and nutrients of TN and TP had inverse functions of precipitation. BOD, COD decrease during the rainy season. Minimum values in the conductivity, TN, and TP were observed during the summer monsoon, indicating an ionic and nutrient dilution of river water by the rainwater. In contrast, major inputs of suspended solids (SS) occurred during the period of summer monsoon. The landuse patterns analyses, based on the variables of BOD, COD, TN, TP and SS, showed that the values were greater in the agricultural stream (Ag) than in the forest stream (Fo) and urban stream (Ur) and that water quality was worst in the urban stream (Ur). The overall dataset suggest that efficient water quality management, especially in Gap-Stream and Miho-Stream, which showed worst water quality is required along with some of urban stream (Ur), based on the analysis of landuse patterns.

A Study on The Effect of Dampening Conductivity in the Offset Printing Printability (오프셋인쇄 축임물의 전도도가 인쇄적성에 미치는 영향에 관한 연구)

  • Park, Chan-Woo;Lee, Jae-Soo
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.25 no.1
    • /
    • pp.43-52
    • /
    • 2007
  • Offset printing is one of the well known printing technique of lithographic process and consists of image area and 'non-image area on a flat image carrier. The surface tension of dampening water can be controlled by adding IPA after mixing of raw water and etching solution. The etching solution contains a surfactant for reducing surface energy, a clean agent for non-imaging area, wetting agent for protecting non-imaging area from oil components like ink and also an emulsifying agent for controlling emulsification. In this study, the present situation of dampening water maintenance has examined by collecting dampening water using at domestic companies. The pH related to dampening water, conductivity, contact angle, emulsification curve are measured to define the current situation of dampening water control of each companies and to analyze the relationship among measured properties. In the study most of companies among 16 printing companies tested controlling dampening water through pH value. However, the quality of printing has varied depending upon conductivity, contact angle, IPA content, and emulsification value. The control of dampening water should be carry at the state of the standard when adding proper ratio of etching solution. It would be more effective when pH or conductivity control carries out in parallel with controlling dampening water. Therefore the concept that pH5.5 is correct is based concept. Based on these initial tests it is defined that the standardization of dampening water control is required.

  • PDF

Analysis of Behavior Characteristics of Water Pollutants in Yeongsan River Using 3D Hydraulic Model (3차원 수리 모델을 이용한 영산강 수질오염물질의 수체 내 거동 특성 분석)

  • Hye Yeon Oh;Eun Jung Kim;Jung Hyun Choi
    • Journal of Korean Society on Water Environment
    • /
    • v.39 no.6
    • /
    • pp.439-450
    • /
    • 2023
  • The Yeongsan River, a major water resource for Jeollanam-do, that is adjacent to industrial complexes and agricultural areas, is exposed to water pollution. Therefore, it is necessary to investigate the impact of water pollution incidences and prepare response systems for river environment safety for other water resources in the future. Environmental Fluid Dynamics Code (EFDC) was applied to the mainstream of the Yeongsan River where residential, commercial, and agricultural areas are located to analyze the behavior of pollutants conducting the scenario analysis. Considering the pollutants that affected the study area, two pollutants, oil and benzene, with different physical and chemical characteristics were selected for the analysis. As a result of comparing the actual and simulated values of the water elevation, temperature, and flow rate, it was confirmed that the model adequately reproduced the hydraulic characteristics of the Yeongsan River. The oil flow dynamics showed that an increase in flow rate led to reduction in the maximum height of the slick. Notably, the behavior of the oil was predominantly influenced by the wind conditions. In the case of benzene, lower flow scenarios exhibited decreased arrival times and residence times accompanied by an elevation in the maximum concentration levels. From the results of pollutant behavior in the study area, it is feasible to utilize the section of tributary confluence for collection and the weir area for dilution. This study enhances the understanding of the pollutant's behavior with different characteristics and develops effective control systems tailored to the physicochemical attributes of pollutants.

Development of a Flow Duration Curve with Unit Watershed Flow Data for the Management of Total Maximum Daily Loads (수질오염총량관리 단위유역 유량측정자료를 이용한 유황곡선 작성)

  • Park, Jun Dae;Oh, Seung Young;Choi, Yun Ho
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.2
    • /
    • pp.224-231
    • /
    • 2012
  • It is necessary to develop flow duration curve (FDC) on each unit watershed in order to analyze flow conditions in the stream for the management of Total Maximum Daily Loads (TMDLs). This study investigated a simple method to develop FDC for the general use of the curve. A simple equation for daily flow estimation was derived from the regression analysis between the 8-day interval flow data of a unit watershed and the daily flow monitoring data of an adjacent upstream region. FDC can be prepared with the calculation of daily flow by the equation for each unit watershed. An annual and a full-period FDC were drawn for each unit watershed in Guem river basin. Standard flow such as low and ordinary flow can be obtained from the annual FDC. Major percentile of flow such as 10, 25, 50, 75 or 90% can be obtained from the full-period FDC. It is considered that this simple method of developing FDC can be utilized more widely for the calculation of standard flow and the assessment of water quality in the process of TMDLs.

Nature-Friendly Design Characteristics of Outdoor Spaces in Brand Apartments (브랜드 아파트에 나타난 자연친화적 외부공간의 디자인 특성에 관한 연구)

  • Hwang, Yeonsook;Lee, SongHyun
    • KIEAE Journal
    • /
    • v.13 no.1
    • /
    • pp.93-100
    • /
    • 2013
  • A outdoor space of the brand apartment can improve the quality of the whole environment in apartment and has differentiated identity in apartment housing through various versions of the green space and water space plan. The purpose of this study is to evaluate nature-friendly design characteristics in brand apartments and to offer a basic information for planning of brand apartment. In concrete, nature-friendly design did by green space and water space that can analyze by visual, and investigation contents divided to position, form, user behavior, link space from user viewpoint by case study. This study examined a case of eight brand apartments located in Gangnamgu, Seoul. We has divided the characteristics of a green space into horizontal type, vertical type, multi-dimensional type and has divided the water space into stagnant water type, flowing stream type, waterfall type and fountain type. The findings are summarized as follows: First, in case of the space of brand apartment, the application of horizontal and vertical greenery was lower compare with multi-dimensional green space. The most of items for multi-dimensional greenery have been planned to the open space and promenade. Second, a stagnant water type of water space features well used in most of the cases but a water space of signs of activity like a flowing stream, waterfall, fountain types were underused because of problem of administrative and maintenance expenses. Thirdly, Water space of brand apartments was planned with specialization item by apartment housing but green space does not have differentiated item and was planned by most similar form.