• Title/Summary/Keyword: Water quality analyze

Search Result 579, Processing Time 0.026 seconds

Water Quality Characteristics of the Major Tributaries in Yeongsan and Sumjin River Basin using Statistical Analysis (통계분석을 이용한 영산강·섬진강수계 주요 유입지천의 수질 특성)

  • Park, Jinhwan;Jung, Jaewoon;Kim, Daeyoung;Kim, Kapsoon;Han, Sungwook;Kim, Hyunook;Lim, Byungjin
    • Journal of Environmental Impact Assessment
    • /
    • v.22 no.2
    • /
    • pp.171-181
    • /
    • 2013
  • In this study, we report the water quality characteristics of pollutants for 4 major tributaries in the Yeongsan and Sumjin river basins using statistical analysis, such as regression equation and factor analysis. The flow rate and water qualtiy data collected from 4 sampling sites(Hwangryoung A, Jiseok A, Chooryeong A, Osu A) in the Yeonsan and Sumjin river basin during the past 3 years were analyzed for 11 parameters(flow rate, dissolved oxgen, pH, water temperature, electric conductivity, biochemical oxygen demand, chemical oxygen deman, total organic carbon, total nitorgen, total phosphorus, suspended solid). The results showed that the concentrations of BOD, COD, TOC, T-N, T-P in Hwangryoung A(HW) and Jiseok A(JS) of the Yeongsan river basin were decreased as the flow rate was increased. This means that rather than nonpoint soources, point sources affect water quality. In the cases of Chooryeong A(CR) and Osu A(OS) in the Sumjin river basin, howerever, nonpoint sources than point sources are an important factor that affects the water quality. Also, the factor analysis technique was employed to analyze principal component influencing on water quality. The results revealed that the first principal component in HW was correlated with EC, DO, T-N, water temperature. This "nitrogen influx according to seasonal pattern" factor may be interpreted. In JS, the first principal component was correlated with BOD, COD, TOC and is likely to represent "organic matter" processes. In CR and OS, BOD, COD, TOC, SS and T-P were significantly correlated and is considered as representing "Organic matter and adsorption of phosphorus on sediments influx". This study is expected to contribute to the effective pollution control/management of the surfac waters in the study sites.

Trend of Research and Industry-Related Analysis in Data Quality Using Time Series Network Analysis (시계열 네트워크분석을 통한 데이터품질 연구경향 및 산업연관 분석)

  • Jang, Kyoung-Ae;Lee, Kwang-Suk;Kim, Woo-Je
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.5 no.6
    • /
    • pp.295-306
    • /
    • 2016
  • The purpose of this paper is both to analyze research trends and to predict industrial flows using the meta-data from the previous studies on data quality. There have been many attempts to analyze the research trends in various fields till lately. However, analysis of previous studies on data quality has produced poor results because of its vast scope and data. Therefore, in this paper, we used a text mining, social network analysis for time series network analysis to analyze the vast scope and data of data quality collected from a Web of Science index database of papers published in the international data quality-field journals for 10 years. The analysis results are as follows: Decreases in Mathematical & Computational Biology, Chemistry, Health Care Sciences & Services, Biochemistry & Molecular Biology, Biochemistry & Molecular Biology, and Medical Information Science. Increases, on the contrary, in Environmental Sciences, Water Resources, Geology, and Instruments & Instrumentation. In addition, the social network analysis results show that the subjects which have the high centrality are analysis, algorithm, and network, and also, image, model, sensor, and optimization are increasing subjects in the data quality field. Furthermore, the industrial connection analysis result on data quality shows that there is high correlation between technique, industry, health, infrastructure, and customer service. And it predicted that the Environmental Sciences, Biotechnology, and Health Industry will be continuously developed. This paper will be useful for people, not only who are in the data quality industry field, but also the researchers who analyze research patterns and find out the industry connection on data quality.

Influence of Water Supply Withdrawal on the River Flow and Water Quality (하천취수가 하천흐름 및 수질에 미치는 영향)

  • Seo, Il Won;Song, Chang Geun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.4B
    • /
    • pp.343-352
    • /
    • 2011
  • The water quantity by intake station as well as the tributary flow discharge acting as sink or source were added to the main flow rate in the present study and RMA-2 and RMA-4 models were applied to the reach from Pal-dang dam to Jam-sil submerged weir to investigate the influence of water supply withdrawal on the river flow and water quality. The numerical results revealed that the water supply withdrawal from 5 intake stations located upstream of Jam-sil submerged weir changed the total flow rate and therby induced different hydraulic characteristics in terms of water surface elevation and velocity. The changed flow field by the inclusion of water intake quantity led to the variation of water quality. By the consideration of the water supply withdrawal, the velocity structure was significantly disturbed by the outflowing flow condition nearby Gu-ui, Ja-yang, and Pung-nap intake stations. Furthermore, the mean velocity was lowered by 25% and the stage upstream of Gu-ui station rose upto 1.5 cm compared with the result by exclusion of water intake. In case of no water withdrawal, the distribution of BOD concentration was parallel throughout the domain. However, when the water withdrawal is considered, the distribution of BOD concentration nearby the Gu-ui, Am-sa, and Ja-yang station was signifiantly changed. In addition, the BOD concentration including the intake stations showed higher value at the downstream of the reach due to the loss of the discharge by water withdrawal effect. It is concluded that both the inflow and outflow discharges from tributaries and water intake stations should be included in the numerical simulation to analyze the hydrodynamic behaviors and mixing characteristics more accurately.

Quality Characteristics of Korean Native Chicken Meat (한국산 토종 닭고기의 품질 특성)

  • 권연주;여정수;성삼경
    • Korean Journal of Poultry Science
    • /
    • v.22 no.4
    • /
    • pp.223-223
    • /
    • 1995
  • A study was conducted to compare the quality characteristics among commercial broiler, Wangchoo (imported dual purpose breed) and Korean native chicken(KNC). Thigh and breast meat of the broiler(7-wk old), Wangchoo(15-wk old), and Korean native chicken(15-wk old) stored for 24 h at 5t were used to analyze chemical composition, physico-chemical characteristics, textural traits and sensory evaluation test. Crude fat and moisture contents in broiler meat and crude protein content in KNC were significantly(P<.05) higher than those in the other breeds regardless of parts of the body. Total collagen content in broiler meat was significantly higher than those of the other breeds, however, the heat-soluble and the acid-soluble collagen content in Wangchoo were significantly lower than those of the other breeds. Water-holding capacities of KNC in breast meat, and of broiler in leg meat were significantly higher than that of the other breeds, while the results of the water-holding capacity and the cooking loss were reversed. Myofibrillar fragmentation index in broiler meat was significantly higher than that in the other breeds regardless of body parts. Hardness, elasticity and cohesiveness in Wangchoo were significantly higher than those in the other breeds. The prominent fatty acids were oleic, palmitic and linoleic acids and run up to 79.03~83.82 %, regardless of breeds and parts. The sensory evaluation score of tenderness, taste and preference in Wangchoo were lower compared to the broiler and KNC, however, they were not significantly different between broiler and KNC. In conclusion, the quality characteristics of KNC were excellent compared to Wangchoo.

  • PDF

An Experimental Study on Engineering Properties of High-Strength Concrete by Revision Error of the Ratio of Surface Moisture in Fine Aggregate (잔골재의 표면수율 보정오차에 따른 고강도콘크리트의 공학적 특성에 관한 실험적 연구)

  • Kang, Suk-Pyo;Jang, Jong-Ho;Park, Yong-Mock;Lee, Seung-Hoon;Yu, Jae-Chul;Kim, Moo-Han
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.53-56
    • /
    • 2000
  • The performance of high-strength concrete is controlled by the fact, affecting the quality management, especially by revision error in water content of the ratio of surface moisture in fine aggregate. The difference in water content results from the revision error of the ratio of surface moisture and errors in sampled aggregate in the processing ready-mixed concrete plant. This study is to investigate the properties of flowing and hardening by investionally varying the revision error of the ratio of surface moisture in fine aggregate to compare and analyze the variance in quality.

  • PDF

A Study on the Development of Analytical Method for Micro-odorous Compounds in Water (흡착제를 이용한 수중의 미량 이취물질 분석법 개발에 관한 연구)

  • Kim, Eun-Ho;Son, Hee-Jong;Kim, Yeong-Ung;Kim, Hyeong-Seok;Sung, Nak-Chang
    • Journal of Environmental Health Sciences
    • /
    • v.25 no.3
    • /
    • pp.103-107
    • /
    • 1999
  • Even if odorous compounds remain very low concentration in water, it cause strong odor. Because Geosmin and most of odorous compound had very low vaporization, those were difficult to analyze with GC/MSD and Purge & Trap. So, we needed pre-treatment method for decreasing amounts of extracting solvents, improving recovery efficiencies and increasing analytical efficiencies. This study developed efficient technology for analyzing odorous compounds, using various adsorbents and extracting solvents. The optimum adsorbent was XAD resins. Especially, XAD-2, XAD-7 and XAD-2010 were superior, but XAD-2 of these and the optimum extraction solvent is MTBE. Other extraction solvents' efficiency is in order of MTBE>Dichloromethane>n-Hexane>Diethylether. The optimum NaCl dosage for increasing efficiency is 5 g in liquid-liquid extraction method. The shaking time(0~24hr) has no concern with adsorption efficiency. The optimum adsorbent is XAD-2 resin and extraction solvent is MTBE. Dosing NaCl, adsorption efficiency is increased in liquid-liquid extraction method, but NaCl has no effect on liquid-solid extraction method. In this experimental results, this algae toxins(Mycrocystin, Anatoxin etc.).

  • PDF

Research on Environmentally-Sound Erosion Control Works(I) -Environment-oriented erosion control works in Japan- (환경(環境)과 조화한 사방사업(砂防事業)(I) - 일본의 환경보전사방(環境保全砂防) -)

  • Chun, Kun-Woo;Ezaki, Tsugio
    • Journal of Forest and Environmental Science
    • /
    • v.12 no.1
    • /
    • pp.13-25
    • /
    • 1996
  • In recent erosion control works, securing not only the disaster prevention space but the environmental space, harmonized with surrounding environment and abundant with biological resources, are emphasized. Inspired of by the fact that efforts to secure such spaces have been being briskly promoted in Japan since the beginning of 1990s', we compile and analyze the Japanese sources about the "environmentally-sound erosion control works" to contribute to the erosion control works of our country. Specifically, in this report, we deal with the subjects of "establishment of the comfortable river environment" and "environmentally-sound erosion control works" which includes "erosion control dam", "water channel works and revetments", "fish routes" and "water quality conservation works".

  • PDF

Water Quality Model for the Toxic Pollutant Transport Analysis in the Nakdong River (낙동강 유역에서의 독성오염물 배출에 따른 수질해석 모형의 개발)

  • 한건연;김광섭
    • Water for future
    • /
    • v.28 no.1
    • /
    • pp.57-70
    • /
    • 1995
  • A water quality model RIV-LAGI for the toxic pollutant transport analysis is developed based on varied flow analysis and one-dimensional Lagrangian method. Applying to the prismatic channel, it shows accurate results compared with the analytical solutions. The model is applied to the Nakdong River to analyze the phenol spill accident, which occurred on March, 1991. The computed results have good agreements with the observed data. The travel times in the reach of Gumi to Mulkeum based on the monthly average and minimum flow are computed. The suggested model can be used to study the impact of the chemical spills and clean-up plans in the Nakdong River.

  • PDF

Voice quality of normal elderly people after a 3oz water-swallow test: An acoustic analysis (3온스 물 삼킴검사 이후 정상 노년층의 음질 변화: 음향학적 분석)

  • Lee, Sol Hee;Choi, Hong-Shik;Choi, Seong-Hee;Kim, HyangHee
    • Phonetics and Speech Sciences
    • /
    • v.10 no.2
    • /
    • pp.69-76
    • /
    • 2018
  • The elderly are at increased risk of developing dysphagia due to aging and illnesses. The aim of the current study was to analyze, via an acoustic study, the change in the voice quality of normal elderly people after a 3oz water-swallow test. Subjects included a group of 60 normal elderly people (age: $mean{\pm}SD=76.9{\pm}6.66$) and 60 healthy young adults (age: $mean{\pm}SD=25.1{\pm}2.36$). Every participant produced a five-second /a/ phonation pre- and post-swallowing, and the fractioned two-second sections were analyzed using the MDVP (multi dimensional voice program) analysis. The elderly group demonstrated a post-swallowing increase in the following related acoustic parameters: fundamental frequency, fundamental frequency variation, amplitude-variation, and noise in both two-second sections. However, the younger group showed an increase only in frequency related acoustic parameters (i.e., STD ) in the first two-second section. The significant changes in values in the post-swallowing parameters might indicate temporary irregularities in pitch and amplitude along with higher amounts of noise in the voice. The results could be attributed to water residues in the vocal fold and vocal tract, as well as a deterioration of the motor and sensory functions caused by anatomical and physiological changes that result from aging.

Program Development for Drawing of 26 Properties and System Analysis on T-s Diagram of Water or Vapor (물의 T-s 선도 상에서 26 종류의 물성치 작도 및 시스템 해석 프로그램 개발)

  • Kim, Deok-Jin
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.157-164
    • /
    • 2008
  • The temperature-entropy diagram of water or vapor displays graphically the thermophysical properties, so it is very conveniently used in various thermal systems. On general T-s chart of water, there are temperature, pressure, quality, specific volume, specific enthalpy, specific entropy. However, various state and process values besides above properties can be plotted on T-s diagram. In this study, we developed the software drawing twenty six kinds of properties, that is temperature, pressure, quality, specific volume, specific internal energy, specific enthalpy, specific entropy, specific exergy, exergy ratio, density, isobaric specific heat, isochoric specific heat, ratio of specific heat, coefficient of viscosity, kinematic coefficient of viscosity, thermal conductivity, prandtl number, ion product, static dielectric constant, isentropic exponent, velocity of sound, joule-thomson coefficient, pressure coefficient, volumetric coefficient of expansion, isentropic compressibility, and isothermal compressibility. Also, this software can analyze and print the system values of mass flow rate, volume flow rate, internal energy flow rate, enthalpy flow rate, entropy flow rate, exergy flow rate, heat flow rate, power output, power efficiency, and reversible work. Additionally, this software support the functions such as MS-Power Point.

  • PDF