• Title/Summary/Keyword: Water qualities

Search Result 648, Processing Time 0.022 seconds

도심지역 지하수관리를 위한 지하수환경 모니터링

  • 이진용;최미정;이명재;이강근
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.09a
    • /
    • pp.277-279
    • /
    • 2002
  • In late of the 1980's, dramatic increase in water use caused over-exploitation of groundwater and deterioration of water quality in urban areas. To monitor quantity of groundwater resources and their qualities, local groundwater monitoring networks were established. Groundwater resources in urban areas are affected by various human activities including underground building construction (subway), pumping for water use, and pavements. Detailed analysis of the monitored groundwater data would provide some good implications for optimal and efficient management for groundwater resources in the urban area.

  • PDF

Characteristics and Improvement of Tap Water Corrosivity in Korea (국내 수돗물의 부식성 특성 및 개선방안)

  • Kim, Jin-Keun;Kim, Yeong-Kwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.5
    • /
    • pp.731-739
    • /
    • 2011
  • To investigate corrosivity characteristics of tap water in Korea, Langelier index (LI) of 30 multi-regional water treatment plants (WTPs) were evaluated. Weekly LI values of 30 WTPs were all negative, which means tap water in Korea might be very corrosive. Maximum LI decrease through water treatment processes was 0.95 under no additional corrosion control process. Based on the correlation results between LI and tap water qualities, pH and calcium concentration were confirmed as major parameters for LI control. Addition of calcium hydroxide with $CO_{2}$ or calcium hydroxide or sodium hydroxide can be chosen based on water quality. Continuous monitoring of LI and related parameters is recommended in water distribution system.

Changes on the Physicochemical Factor of Stream Water by Medium and Small type Fish Farm in Mt. Baegun Area (백운산 지역내 중소형 양어장에 의한 계류수의 이화학적 요인의 변화)

  • Park, Jae-Hyeon
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.8 no.3
    • /
    • pp.43-52
    • /
    • 2005
  • Evaluations of the fish farm influences on stream water quality may provide basic informations on watershed management to reduce environmental impact due to fish farm development and to conserve stream water quality in forested watershed area. In this research influent, effluent water in the fish farm and stream water qualities around Mt. Baegun area were monitored seasonally for six years and the following results were obtained. Due to the increase of pH in effluent water from the fish farm it was believed that alkalization of stream water can be accelerated by large scale development of fish farms in the forested watershed area. Also, effluent water from the fish farm increase of EC higher than influent and stream water. As a result of regression analyses, pH, EC, DO, water temperature, total amount of cation and anion in influent and effluent water of fish farm show high significance.

Effects of Artificial Supercooling Followed by Slow Freezing on the Microstructure and Qualities of Pork Loin

  • Kim, Yiseul;Hong, Geun-Pyo
    • Food Science of Animal Resources
    • /
    • v.36 no.5
    • /
    • pp.650-655
    • /
    • 2016
  • This study investigated the effects of artificial supercooling followed by still air freezing (SSF) on the qualities of pork loin. The qualities of pork frozen by SSF were compared with the fresh control (CT, stored at 4℃ for 24 h), slow freezing (SAF, still air freezing) and rapid freezing (EIF, ethanol immersion freezing) treatments. Compared with no supercooling phenomena of SAF and EIF, the extent of supercooling obtained by SSF treatment was 1.4℃. Despite that SSF was conducted with the same method with SAF, application of artificial supercooling accelerated the phase transition (traverse from -0.6℃ to -5℃) from 3.07 h (SAF) to 2.23 h (SSF). The observation of a microstructure indicated that the SSF prevented tissue damage caused by ice crystallization and maintained the structural integrity. The estimated quality parameters reflected that SSF exhibited superior meat quality compared with slow freezing (SAF). SSF showed better water-holding capacity (lower thawing loss, cooking loss and expressible moisture) and tenderness than SAF, and these quality parameters of SSF were not significantly different with ultra-fast freezing treatment (EIF). Consequently, the results demonstrated that the generation of supercooling followed by conventional freezing potentially had the advantage of minimizing the quality deterioration caused by the slow freezing of meat.

Water Quality and Pollutions of River waters in Gwangju City (광주광역시 하천수의 수질 및 오염)

  • 오강호;고영구
    • Journal of Environmental Science International
    • /
    • v.12 no.3
    • /
    • pp.287-297
    • /
    • 2003
  • To investigate water quality and pollution states of rivers in Gwangju city, total of 30 water samples were taken from the main stream of Yeongsan river, Hwangryong river and Gwangju stream in dry and flood seasons. Physico-chemical characteristics of above streams according to pH-Eh and Piper's diagrams we, typically, assigned to natural river water. In the streams, BOD, COD, T-N and T-P indicating water quality mostly increase toward downstream. Notably, water qualities in area near connection between the Gwangju stream and the main stream of Yeongsan river are polluted over V level in rivers and lakes water quality standard. The pollutions are influenced by lift and agricultural foul waters from Gwangju City and farming areas around upstream branches of the Yeongsan river, reasonably. Besides, heavy metals are below the standard in those streams. So, it is considered that the streams are polluted by not industrial but life/agricultural foul waters.

The effect of Combined Sewer Overflows on river's water quality

  • Bae, Hun Kyun
    • Membrane and Water Treatment
    • /
    • v.11 no.1
    • /
    • pp.49-57
    • /
    • 2020
  • The effect of Combined Sewer Overflow on the river system was investigated throughout three preliminary field tests and three main ones. As a result of the study, Combined Sewer Overflow did not affect water qualities on the main stream since the concentration of the main stream did not significantly changed during rainfall events although the water quality of tributaries has rapidly deteriorated due to the influence of the Combined Sewer Overflow during rainfall events. The main cause of the result is that the flow rate of the tributaries is considerably lower than that of the main stream, so that the tributaries with deteriorated water quality during rainfall events did not significantly affect the quality of the actual main stream. Therefore, the water quality of the Kumho River is more affected by the wastewater treatment facilities that discharges water continuously to the main stream than pollutants from non-point pollution sources during rainfall events. As a result, managements for discharges from wastewater treatment facilities should be strengthened in order to improve the water quality of the river.

Quantitative and Qualitative Assessment of Blow Down Wastewater from Yeosu Industrial Complex (여수석유화학산단 산업폐수 재이용을 위한 블로우 다운 (Blow Down)수 발생현황 조사)

  • Kwon, Tae-Ouk;Moon, Il-Shik
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.3
    • /
    • pp.289-296
    • /
    • 2005
  • Purpose of this research is to quantitatively and qualitatively investigate the blow down wastewater produced from Yeosu Industrial Complex. Approximately, 38,325,000 tons/year of wastewater is produced, processed and finally discharged. Six representative companies, namely, A, B, C, D, E, F were chosen for this study. Each company produce over 5,000 tons/day of wastewater. In total, 6,844 tons/day of blow down water is produced from these six companies, put together. However, companies A and C produce about 24% and 37% of blow down water, respectively. It was found that the blow down water had favorable qualities, except for its high conductivity, ranging from 230 to $1,700{\mu}s/cm$. It was evident that, this water can be suitable for reuse, for industrial purposes, if a suitable treatment, for example, RO membrane process is adopted to remove high conductivity.

Infant target facilities and facilities for children in elementary school Comparison and Improvement of Indoor Air Quality for Research (영유아 대상 시설의 실내공기질 특성 비교 및 개선방안에 대한 연구)

  • Seo, Byong-Won;Lee, Ju-Hwa;Park, Ji-Hoon;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.5
    • /
    • pp.591-601
    • /
    • 2013
  • In modern society, we are living indoor at 80 - 90 % or more of the day, therefore most people are exposed to unconscious indoor air pollutants by various causes. When mother and infant, whose level of immunity are weak, are exposed to polluted indoor air, respiratory diseases and atopy can occur by the growth of bacteria. Therefore, appropriate indoor air quality management is important especially at nursery, elementary school and postpartum clinic etc. In this study, we compared the characteristics of the indoor air qualities of primary school facilities and infant facilities. In this study, seasonal effects were investigated. Also the effects of individual activity area were studied for indoor air quality. During summer season(May-August), the air qualities of each 16 elementary school and nursery school were investigated. During winter season(October-december), the air qualities of each 10 elementary school and nursery school were investigated. As a result, during winter season in 10 of 16 nursery school, $CO_2$ concentration exceeded regulation level of 1000 ppm. This resulted from the operation of heating system and poor ventilation. Also the air quality of all parameters during winter season were worse than during summer, maybe due to poor ventilation. Except HCHO, the concentrations of other parameters were higher in nursery school. This seems to result from relatively low individual activity area of nursery school than elementary school. From this research, more strong regulation for ventilation and installation of air purifier should be implemented.

Characteristics of Water and Sediment Qualities in the Oncheon Stream, Busan during Summer Rainy Season (부산 온천천의 하계 우수기 수질 및 퇴적물 환경 특성)

  • Lee, Young-Hyeong;Moon, Changho;Kang, Hyun-Jung;Choi, Seong-Ryul;Kim, Suk-Hyun
    • Journal of Environmental Science International
    • /
    • v.29 no.6
    • /
    • pp.659-672
    • /
    • 2020
  • Water and sediment qualities were investigated in the Oncheon Stream and at the Wondong bridge of the Suyoung River, during the summer rainy season, 2019. Dissolved oxygen (DO) showed the lowest levels at 4.7 and 5.0 m/L, and biogeochemical oxygen demand (BOD) showed the highest at 5.3 mg/L downstream where the tributary flows into the main river. Chemical oxygen demand (COD) increased from 2.0 to 5.9 mg/L on average as it flowed downstream, The COD/BOD ratio decreased gradually as it flowed downstream, reaching 1.0. However, COD/BOD ratio at the Wondong bridge was 5.8-22.2, indicating that easily biodegradable and non-biodegradable organic matter flows into the Oncheon Stream and Suyoung River, respectively. Total nitrogen (T-N) / total phosphorus (T-P) ratio tended to decrease from 72 to 21 as it flowed downstream, measuring 71 to 86 at the Wondong bridge. The water quality index (WQI) generally improved better than grade IV after heavy rainfalls. However, DO and T-P were the parameters that deteriorated the WQI. Ignition loss (IL), COD, T-N, and T-P of sediments had distribution of 1.44 ± 1.01%, 0.35 ± 0.16%, 43 ± 63 mg/kg, and 10.9 ± 21.9 mg/kg, respectively. These were several times lower than the annual averages of IL, T-N, and T-P in 2017 before the dredging project was conducted in the first half of 2018.

Characteristics of T-N and T-P Runoff Loadings of Churyeong-cheon Watershed in the Seomjin River Basin (섬진강 수계 추령천 유역의 총질소 및 총인의 유출부하 특성)

  • Choi Jin-Kyu;Son Jae-Gwon;Koo Ja-Woong;Yoon Kwang-Sik;Kim Young-Joo
    • KCID journal
    • /
    • v.9 no.2
    • /
    • pp.43-50
    • /
    • 2002
  • To provide the basic information for the water quality improvement of the Seomjin River Basin, the water qualities of the Churyeong-cheon watershed were investigated from May in 1999 to September in 2002. Annual total runoff at the Churyeong-cheon watersh

  • PDF