• 제목/요약/키워드: Water plant

검색결과 6,610건 처리시간 0.04초

Pump availability prediction using response surface method in nuclear plant

  • Parasuraman Suganya;Ganapathiraman Swaminathan;Bhargavan Anoop
    • Nuclear Engineering and Technology
    • /
    • 제56권1호
    • /
    • pp.48-55
    • /
    • 2024
  • The safety-related raw water system's strong operational condition supports the radiation defense and biological shield of nuclear plant containment structures. Gaps and failures in maintaining proper working condition of main equipment like pump were among the most common causes of unavailability of safety related raw water systems. We integrated the advanced data analytics tools to evaluate the maintenance records of water systems and gave special consideration to deficiencies related to pump. We utilized maintenance data over a three-and-a-half-year period to produce metrics like MTBF, MTTF, MTTR, and failure rate. The visual analytic platform using tableau identified the efficacy of maintenance & deficiency in the safety raw water systems. When the number of water quality violation was compared to the other O&M deficiencies, it was discovered that water quality violations account for roughly 15% of the system's deficiencies. The pumps were substantial contributors to the deficit. Pump availability was predicted and optimized with real time data using response surface method. The prediction model was significant with r-squared value of 0.98. This prediction model can be used to predict forth coming pump failures in nuclear plant.

정수처리과정(淨水處理過程)에서의 잔류불소(殘留弗素)이온 거동(擧動)에 관한 연구(硏究) (A Study on the Behavior of Residual Fluoride in Water Treatment Process)

  • 이택순;문병현;서규태;진홍식
    • 상하수도학회지
    • /
    • 제14권2호
    • /
    • pp.164-173
    • /
    • 2000
  • Fluoridation of drinking water to a level of about 0.8mg/l (below 1.5mg/l) for reducing the incidence of tooth decay is recommended. However, concerns about potential problems of unknown effects and overdosing hinders the fluoridation. This study describes the work performed to obtain information on the behavior of fluoride under various conditions in the process of water fluoridation. Effects of water treatment chemicals, water treatment unit, and water distribution on water fluoridation were investigated at both lab and an actual water treatment plant. Residual fluoride concentration was not affected by lime and chlorine dosage up to 20mg/l. Flocculation with PAC slightly decreased the residual fluoride concentration as PAC dosage increased. Average fluoride concentration of 0.87mg/l at an intake basin was decreased to 0.83mg/l by sedimentation, 0.81mg/l by dual media(sand+anthracite) filtration, and 0.79mg/l by granular activated carbon filtration in the water treatment plant.

  • PDF

오리피스를 통한 기기냉각수 계통 Water Balance 정상화 (Stabilization of Water Balance of Closed Cooling Water System with Orifice)

  • 이성건;박종환;이은수
    • 플랜트 저널
    • /
    • 제13권4호
    • /
    • pp.38-40
    • /
    • 2017
  • 본 연구는 기기냉각수 계통 Water Balance 정상화 방안을 위한 연구로 비용 대비 효과를 고려하여 최적안을 도출한다. Water Balance 검토를 위해 배관망해석프로그램이 사용되며, 프로그램의 신뢰성을 높이기 위해 초음파유량계로 현장 계측을 통해 시뮬레이션 계수 보정을 진행한다. 이를 토대로 다양한 Case Simulation을 통해 최적운전방안에 대해 도출하는 것이 목적이다.

  • PDF

우리나라 농업용수 수질오염 현황과 개선대책 (A Status of Agricultural Water Quality and Improvable Countermeasure in Korea)

  • 백청오;강상구;이광식
    • 한국환경농학회지
    • /
    • 제15권4호
    • /
    • pp.506-519
    • /
    • 1996
  • The water quality in the rural areas is degrading due to a variety of causes such as the increase of the urban sewage and industrial wastes, the disposal of solid wastes, the growth of livestock waste, the growth of leisure facilities, the establishment of agricultural industry estates and etc. The water pollutants are scarce while the effluent is increasing from wide scattered sources. The technology specifically designed for the rural wastes water treatment plant needs to be implemented with improvement of agricultural water quality. 1. An integrated management measures against water pollution sources. The prevention of water pollution is the best measures in the environmental pollution. Hence, the most effective measures needs to be against the sources. Small-scale water treatment plants needs to be constructed in each village in the rural areas. As for the industrial effluent, the effluent discharge needs to be strictly monitored. Government subsidy for the establishment of treatment plant for livestock wastes is necessary. 2. The establishment of national-wide network for agricultural water quality. The network for agricultural water quality have been operated to conserve the agricultural water quality, and to develop management policies by the assessment of water pollution in the rural areas. The results of agricultural water quality network indicates that the water quality is degrading not only around urban areas but also in the distant rural areas, and the water quality at the pumping stations and weirs is worse than that of reservoirs. 3. The legal, systematic, and technical approaches for the agricultural water quality management. The actions currently implemented for the improvement of agricultural water quality involve temporary measures such as the improvement of irrigation facilities. These contingency measures are not effective in the long-term, and sometimes bring secondary pollution. Therefore, integrated measures covering the whole water environment such as the flow, quality, river morphology, aquatic ecosystem, and the surrounding environment, need be invented and implemented. Besides, the legal, systematic, and technical frameworks for the management are not fully established so far. The technology for the treatment of rural water pollution should be refined afterwards, and the research for the development of rural waste water treatment plant should be carried out.

  • PDF

인공습지 내 개방수역 조성에 따른 처리효율분석 (Analysis of Treatment Efficiency according to Open-water in Constructed Wetland)

  • 김형철;윤춘경;엄한용;김형중;함종화
    • 한국물환경학회지
    • /
    • 제24권6호
    • /
    • pp.709-717
    • /
    • 2008
  • The field scale experiment which is constructed with four sets (0.88 ha for each set) of wetland (0.8 ha) and pond (0.08 ha) systems was performed to examine the effect of plant coverage on the constructed wetland performance and to recommend the optimum development and management of macrophyte communities. After six growing seasons of wetlands, plant coverage was about 100%. And the concentration of DO showed low value (1.0~5.4 mg/L). This is caused by a blighted plant consumed dissolved oxygen with decay in water column. As the result, water column went to be anaerobic conditions and T-N removal rate are 58~67%. Dead vegetation increased nitrogen removal during winter because it is a source of organic carbon which is an essential parameter in denitrification. However, wetland released phosphorus caused by a blighted plant and accumulation, the removal rate of phosphorus might be decreased. To rise of DO concentration, the three open-waters were constructed in cell 3 and 4. Cell 3 has two open-waters (width 10 m, depth 1.8 m) and cell 4 has one open-water (width 20 m, depth 1.8 m). As the result, DO concentration and treatment efficiency of nutrient and BOD were improved. In case that constructed wetland is operated for a long time, physical circulation structure such as open water help continuous circulation of aerobic and anaerobic conditions. Through the constructed open-water, treatment efficiency of phosphorus and nitrogen in wetland could be improved effectively.

한국 서남해안 습지의 식물 군집에 미치는 토양요인 (Soil Factors Affecting the Plant Communities of Wetland on Southwestern coast of Korea)

  • 임병선;이점숙
    • The Korean Journal of Ecology
    • /
    • 제21권4호
    • /
    • pp.321-328
    • /
    • 1998
  • To describe the major environmental factors operating in coastal wetland and to characterize the distribution of the plant species over the wetland in relation to the major environmental gradients, 12 soil physical and chemical properties were determined. The gradient of water and osmotic potential of soil, electrical conductivity, sodium and chloride content and soil texture alsong the three habitat types of salt marshes, salt swamp and sand dune were occurred. The 24 coastal plant communities from principal component analysis (PCA) on the 12 variables were at designated as a gradient for soil texture and water potential related with salinity by Axis I and as a gradient for soil moisture and total nitrogen gradient by Axis II On Axis I were divided into 3 groups (1) 9 salt marsh communities including Salicornia herbacea communities (2) 5 salt swamp communities including Scirpus fluviatilis communities and (3) 10 sand dune communities including Jmperata cylindrica communities on Axis II were divided into 2 groups (1) salt marsh and sand dune communities, and (2) 3 salt swamp communities. The results could account for the zonation of plant communities on coastal wetland observed alsong envionmental gradients.

  • PDF

Demonstration of EPRI CHECWORKS Code to Predict FAC Wear of Secondary System Pipings of a Nuclear Power Plant

  • Lee, Sung-Ho;Seong Jegarl;Chung, Han-Sub
    • Nuclear Engineering and Technology
    • /
    • 제31권4호
    • /
    • pp.375-384
    • /
    • 1999
  • The credibility of CHECWORKS FAC model analysis was evaluated for plant application in a model plant chosen for demonstration. The operation condition at each pipe component was defined before the wear rate analysis by plant data base, water chemistry analysis, and network flow analysis. The predicted wear was compared with the measured wear for 57 sample components selected from 43 susceptible line groups analysed. The inspected 57 locations represent components of highest predicted wear in each line group. Both absolute value and relative ranking comparisons indicated reasonable correlations between the predicted and the measured values. Four components showed much higher measured wear rates than the predicted ones in the feed water train from main feed water pump discharge to steam generator, probably due to high hydrazine concentration operation the effect of which had not been incorporated into the CHECWORKS model. The measured wear was higher than the predicted one consistently for components with least susceptibility to FAC. It is believed that the conservatism maintained during UT data analysis dominated the measurement accuracy. A great deal of enhancement is anticipated over the current plant pipe management program when a comprehensive plant pipe management program is implemented based on the model analysis.

  • PDF

Characterization of Chitinase in Oak Tissues and Changes in Its Activity Related to Water Stress and Inoculation with Hypoxylon atropunctatum

  • Chun, Se-Chul;Fenn, Patrick;Kim, Kyung-Soo
    • The Plant Pathology Journal
    • /
    • 제15권3호
    • /
    • pp.144-151
    • /
    • 1999
  • Chitinase activities from Shumard oak tissues were determined to study changes in chitinase activities related to water stress. The enzyme extracted in sodium acetate buffer (0.1M, pH 4.5) was assayed by a colorimetric method. In addition, the fungal hyphae of Hypoxylon atropunctatum in xylem tissues of oak were observed through scanning electron microscopy. The enzyme in oak tissues was mainly endochitinase, and optimum pH for enzyme activity was 5. Specific chitinase activities from both of stems held under high relative humidity (ranges of 0.63-1.11 pKatal/$\mu\textrm{g}$ of protein) and stems held under low relative humidity (ranges of 0.41-0.99 pKatal/$\mu\textrm{g}$ of protein) were significantly increased following fungal inoculation with H. atropunctatum. However, there was no significant difference in chitinase activities between tissues held under high and low humidities, which might be due to fungal chitinase. Scanning electron microscopy showed holes in fungal hyphae in the xylem tissues of stems held under high humidity but not in the stems held under ow humidity, suggesting that hyphae might be hydrolyzed by plant hydolases such as chitinase.

  • PDF

Inhibitory Effects of Super Reductive Water on Plant Pathogenic Fungi

  • Hur, Jae-Seoun;Kim, Hae-Jin;Oh, Soon-Ok;Koh, Young-Jin;Kwak, Young-Se;Lee, Choong-Il
    • The Plant Pathology Journal
    • /
    • 제18권5호
    • /
    • pp.284-287
    • /
    • 2002
  • The antifungal activity of super reductive water (SRW) against plant pathogenic fungi was examined to extend its application to integrated pest management (IPM) for plant diseases. Diluted solutions ($\times$1/10, $\times$1/25, and $\times$1/50) of SRW inhibited fungal growth of kiwifruit soft rot pathogen, Diaporthe actinidiae, in a concentration dependent manner, When kiwifruits were inoculated on wounds with mycelium blocks, stock and diluted solutions successfully inhibited the disease development. In addition to the high pH of the SRW, fungistatic activity was also considered as the cause of the antifungal effect against the pathogen. Whereas conidial germination of Magnaporthe grisea was not affected by the diluted SRW solutions, appressorium formation was significantly inhibited in a concentration dependent manner, With little harmfulness to human health and environment SRW could be used to control plant pathogenic fungi, particularly appressorium-forming fungal pathogens.

배관 해석 프로그램을 통한 해수담수화 플랜트 수압 시스템 분석 (Analysis of hydraulic system for seawater desalination plant through piping analysis program)

  • 최지혁;최용준;양흥식;이상호;최준석
    • 상하수도학회지
    • /
    • 제34권3호
    • /
    • pp.221-230
    • /
    • 2020
  • In actual seawater desalination plant, the pressure loss due to frictional force of pipe is about 3~5 bar. Also, the pressure loss at pipe connection about 1~3 bar. Therefore, the total pressure loss in the pipe is expected to be about 4~8 bar, which translates into 0.111 to 0.222 kWh/㎥ of energy when converted into the Specific Energy Consumption(SEC). Reducing energy consumption is the most important factor in ensuring the economics of seawater desalination processes, but pressure loss in piping is often not considered in plant design. It is difficult to prevent pressure loss due to friction inside the pipe, but pressure loss at the pipe connection can be reduced by proper pipe design. In this study, seawater desalination plant piping analysis was performed using a commercial network program. The pressure loss and SEC for each case were calculated and compared by seawater desalination plant size.