매스콘크리트 구조물에서 파이프쿨링을 고려한 수화열 해석 (Thermal Analysis Associated with the Application of Pipte Cooling System to a massive Concrete Structure)

  • 김상철;이두재;김재권;강석화;김진근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 가을 학술발표대회 논문집(III)
    • /
    • pp.922-927
    • /
    • 1998
  • Pipe cooling has been popularly used in the mass concreting work to reduce temperature of the structure since it is known to be the easiest way to apply and has been the customary usage. But wrong application of the system results in the harmful effect on the structure by crack formation due to thermal shocks and improper cooling schemes. Thus, this study aims at the suppling of effective cooling methods through parametric study. For this, circulating method, velocity of water supply and circulating duration were selected as critical factors affecting the effectiveness of cooling system. As a results of thermal analysis, it was found that too much thermal gradient in the vicinity of the pipe creates localized radial or circumferential cracks. The duration of circulating cooling may be recommended to be as short as several days which may safely reduce the concrete temperature to below a final stable value. It was also found that pipe cooling is more effective to decrease the degree external restraints than internal one.

  • PDF

소독부산물 최소화를 위한 운영조건 연구 (Operating Conditions for Minimization of DBPs (Disinfection by-Products) in Drinking Water Supply System)

  • 신형순;최필권;김종수;최일우;김상훈;김태현;이경희;이수문;장은아;정연훈;김주열
    • 상하수도학회지
    • /
    • 제19권3호
    • /
    • pp.330-337
    • /
    • 2005
  • This study was carried out to propose the managemental improvement of the purification plants and the distribution facilities which can minimize the formation of disinfection by-products in drinking water distribution system. The disinfection by-products were highly created in the water treatment plant that the organic matters were high and the chlorine dosage was excessive. The concentration of DSPs was shown the highest value in August and the lowest value in December, because of temperature and pre-chlorine dosage effect. From the result of tracer test, the travel time from the treatment plant to the end of pipeline was around 3-4 days in summer, 5-6 days in winter, respectively, and the DSPs concentration of the reservoir(end of pipe) was 2-3 times higher than that of the beginning point. The improvement of the chlorination process and structural reformation of distribution facility was demanded to minimize the DSPs increase from purification plant to the end of pipe.

복사난방패널의 설계 및 운전을 위한 열적 특성 분석 (An analysis of the thermal characteristics for optimal design and operation of the radiant heating panels)

  • 이태원
    • 설비공학논문집
    • /
    • 제9권2호
    • /
    • pp.180-188
    • /
    • 1997
  • The theoretical analysis and experiment with simulator were performed to obtain the temperature distributions in radiant heating panel and heat supply from hot water to heating space for the purpose of the development of comfortable living space from a point of view of the improvement of air quality and the enhancement of system efficiency. The relations of various parameters, such as pipe pitch, room temperature as well as flow rate and temperature of hot water and so on, with the rate of heat supplied, mean temperature and maximum temperature difference at panel surface were discussed. The effects of these parameters were also verified on the thermal performance of heating panel using the relations which could be used for the optimal design and operation of the radiant heating panel.

  • PDF

Quantifying Energy Consumption to the Level of Service Pressure in Water Distribution Network

  • Marlim, Malvin S.;Choi, Jeongwook;Kang, Doosun
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2022년도 학술발표회
    • /
    • pp.458-458
    • /
    • 2022
  • It is essential to reduce global carbon emissions, mainly from energy use. The water supply and distribution sector is a vital part of human society and is one of the primary energy consumers. The procurement and distribution of water require electricity to operate the pump to deliver water to users with sufficient pressure. As the water users are spatially distributed over a wide area, the energy required to deliver water to each user differs depending on the corresponding supplying element (reservoir, tank, pipe, pump, and valve). This difference in energy required for each user also comes with a difference in pressure availability which affects the level of service for individual users and the whole network. Typically, there is a disproportion where users close to the source experience excessively high pressure with low energy consumption. In contrast, remote users need more energy to get the minimum pressure. This study proposes the Energy Return Index (ERI) to quantify the pressure return from particular energy consumption to supply water to each node. The disproportionality can be quantified and identified in the network using the proposed ERI. The index can be applied to optimize the network elements such as pump operation and tank location/size to reach a balanced energy consumption with the appropriate level of service.

  • PDF

대전지역 상수도 물의 계절변화에 따른 물리화학적 불균질 (Physicochemical Heterogeneity of the Supply Water Quality depending on Seasonal Changes in the Taejon Area, Korea)

  • 이현구;이찬희;서호택
    • 자원환경지질
    • /
    • 제33권6호
    • /
    • pp.505-517
    • /
    • 2000
  • This study was undertaken to provide a drinking water quality on the basis of physicochemical properties. In this study, the 25 samples of supply waters of the Taejon area were sampled twice (February and August in 1999). Hydrochemistry of the supply water belongs to the $Ca^{2+}$-${HCO_3}^{-1}$ type, whereas the supply water was characterized by the relatively significant enrichment of ${Ca}^{2+}$, ${Na}^{2+}$, ${K}^{2+}$, ${Cl}^{2+}$ ions and heavy metals compared to the original water from the Daecheong lake. Generally, the supply water has a mean values for $10.7^{\circ}C$ of temperature, 6.86 of pH, -12 mV of Eh, 88 ${\mu}S$/cm of EC and 70.379 mg/l of TDS in February, whereas the waters of the same sites in August are a slightly high temperature ($26.1^{\circ}C$), TDS (78.069 mg/l) and extremely high EC (442 ${\mu}S$/cm) value. These values are similar with physicochemical properties of the original lake water depending on the seasonal differences. Results of speciation calculation indicate that potentially toxic ions might exist mainly in the forms of free metal (${Cu}^{2+}$ or ${Zn}^{2+}$) and a small amount of ${CO_3}^{2-}$and ${OH}^{-}$in the supply water. The water seemed to be in equilibrium with kaolinite field of the normal stability diagrams for the natural water. Based on enrichment parameter of the supply water normalized by original lake water composition, the average value of those parameter can be calculated with nearly 1.00, but the those values for Cu+Zn possible source of decrepit pipe lines are 126.75 in February and 115.63 in August samples. The parameter values varied with sampling sites, however, do not exceed by chemistry of drinking water standard. Solid compounds remained on the membrane filter papers after filtration are adhered to pale yellow or yellowish brown colored dissolved solids and precipitates, which are coated by 0.02 to 0.35 mm thick per 500 ml with colloidal particles of about 1 to 2${\mu}m$ size. The particles are mainly Fe-Cu-Zn compounds and partly detected to Mn and Pb.

  • PDF

상수도관로 위치탐사 장비개발을 위한 기초실험 (Fundamental Experiment for the Development of Water Pipeline Locator)

  • 박상봉;김진원;오경석;김민철;구자용
    • 상하수도학회지
    • /
    • 제30권3호
    • /
    • pp.253-261
    • /
    • 2016
  • A variety of methods for detecting the location of an underground water pipeline are being used across the world; the current main methods used in South Korea, however, have the problems of low precision and efficiency and the limitations in actual application. On this, this study developed locator capable of detecting the location of a water pipe by the use of an IMU sensor, and technology for using the extended karman filter to correct error in location detection and to plot the location on the coordinate system. This study carried out a tract test and a road test as basic experiments to measure the performance of the developed technology and equipment. As a result of the straight line, circular and ellipse track tests, the 1750 IMU sensor showed the average error of 0.08-0.11%; and thus it was found that the developed locator can detect a location precisely. As a result of the 859.6-m road test, it was found that the error was 0.31 m in case the moving rate of the sensor was 0.3-0.6 m/s; and thus it was judged that the equipment developed by this study can be applied to long-distance water pipes of over 1 km sufficiently. It is planned to evaluate its field applicability in the future through an actual pipe network pilot test, and it is expected that locator capable of detecting the location of a water pipe more precisely will be developed through research for the enhancement of accuracy in the algorithm of location detection.

기존 상수도 노후관망의 개량 및 관리 기법의 개발 (Development of Rehabilitation and Management Techniques for Old Water Distribution Systems)

  • 김중훈;김종우
    • 물과 미래
    • /
    • 제29권3호
    • /
    • pp.197-205
    • /
    • 1996
  • 상수도 관망시설에서 각 관로는 시간이 경과함에 따라 각종 부식이 일어나 통수능이 저하된다. 그러므로 적절한 시기에 갱생이나 교체 등의 처리를 해주어야 한다. 본는 연구에서는 각 수요절점에서 요구수량, 요구압력 등 수리학적 조건을 만족시켜주며 동시에 최소의 비용으로 노구된 관로를 처리해주는 의사결정모형을 개발하였다. 교체비용, 관파열보수비용, 양수비용, 관 파열율, 연이율 등은 각 관로의 교체시기를 경제적으로 결정하는데 이용된다. 그리고 배수시설의 수리학적 만족여부는 관망계산 프로그램 KYPIPE에 의해 점검된다. 시스템이 수리학적 조건을 만족지 못할 경우 교체시기는 조건이 만족될 때까지 앞당겨진다. 본 모형은 기존 송배수시설인 수도권 광역상수도 제1단계에 적용되었다. 모형을 이용해 산출한 최적교체시키는 수리학적으로 모의해본 결과 문제가 없으며를 알 수 있었다.

  • PDF

폐정화조를 재활용한 다목적 빗물관리시스템 구상 및 경제성 분석 (Recycling of a discarded septic tank as a rainwater management system and it's economic feasibility analysis)

  • 김미경;곽동근;한무영;양지청
    • 상하수도학회지
    • /
    • 제23권5호
    • /
    • pp.647-654
    • /
    • 2009
  • Since the end of the 1990s, sewer pipe improvement works have been going on: most septic tanks have been thrown away and discarded. These discarded septic tanks amounts up to 370,000 based on the project plan 2005-2008: it is a serious squander of nation's resources, a contaminating means that buries toxins under soil, and a cause of a expensive waste. Research on recycling of discarded septic tank as a new resource is in urgent need. This research suggests plans to recycle discarded septic tank as a rainwater management facility, solutions to water cycle recovery in the limelight, and economic analysis of the plan. In the case of a recycling discarded septic tank as a rainwater management facility will socially benefit to support economical adequacy, discard cost saving of septic tank and water supply and sewage cost reduction will come out. Consequently a rainwater management facility converted from a discarded septic tank leads to decentralization of the rainwater management system, which anticipates a positive effect on recovery of urban water cycle.

원격 상수도관망 누수감지 시스템에 관한 연구 (A Study on a Remote Leakage Sensing System in Waterworks Network)

  • 강병모;홍인식
    • 정보처리학회논문지D
    • /
    • 제11D권6호
    • /
    • pp.1311-1318
    • /
    • 2004
  • 인구증가와 발전으로 도시 집중화 현상에 따라 수도의 수요증가가 가속화되는 상태이다. 특히 물 부족현상 및 수질악화로 인한 수원확보도 어려워지고 있는 실정이다. 누수로 인한 막대한 손실을 줄이고자 컴퓨터와 인터넷을 이용하여 누수가 발생할 경우, 누수 여부를 판단하고 중앙 모니터링 센터에서 관리할 수 있는 시스템이 필요하다. 본 논문에서는 누수감지관과 TDR을 이용한 원격 상수도관망 누수 감지 시스템을 제안하였다. 유효성을 입증하기 위해 300mm 3-레이어 강관으로 파이로트 시스템을 구축하여 시뮬레이션 하였다.

모세유관 바닥복사 냉·난방 시스템의 성능평가 (Performance Evaluation of the Capillary Tube Radiant Floor Cooling & Heating System)

  • 서유진;김태연;이승복
    • KIEAE Journal
    • /
    • 제12권4호
    • /
    • pp.89-95
    • /
    • 2012
  • At present, many countries are trying to reduce green gas emissions to mitigate the effects of these gases on climate change. Year after year, there have been efforts to cut energy use for heating and cooling. Heating and cooling systems, common in all forms of housing, are increasing due to the constant supply of new housing resulting from improvements in economic growth and the quality of life. Thus, studies related to the design of cooling and heating systems to improve energy efficiency are expanding. Among the new designs, radiant floor cooling and heating systems which use capillary tubes are becoming viable means of reducing energy use. Radiant floor cooling and heating systems which use capillary tubes are creative and sustainable systems in which cool and hot water is circulated into capillary tube which has small diameter. In this study, the cooling and heating performance of this type of capillary tube system is investigated in an experimental study and a simulation using TRNSYS. The results of the experimental study show that under a peak load, a capillary tube radiant floor cooling system using geothermal energy can achieve desired indoor temperature without an additional heat source. The set room air temperature is maintained while the floor surface temperature, PMV and PPD remain within the comfort range. Also, this system is more economic than a packaged air conditioner system due to its higher COP. The results of the simulation show that the capillary tube radiant floor heating system maintains set temperature more stable than a PB pipe radiant floor heating system due to its lower supply temperature of hot water. In terms of energy consumption, the capillary tube radiant floor heating system is more efficient than the PB pipe radiant floor heating system.