• Title/Summary/Keyword: Water pipe supply

Search Result 265, Processing Time 0.027 seconds

Correlation Analysis of the Occurrence of Ground Subsidence According to the Density of Underground Pipelines (지중관로 매설 밀집도에 따른 지반함몰 발생 상관 분석)

  • Kim, Jinyoung;Kang, Jaemo;Choi, Changho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.22 no.11
    • /
    • pp.23-29
    • /
    • 2021
  • Recently, ground subsidence has been steadily occurring mainly in downtown areas, threatening the safety of citizens. Under the road, various underground facilities such as water supply pipe, sewage pipe, and communication pipe are buried. Due to the aging of these underground facilities and the reckless development of the underground, it is acting as a cause of ground subsidence. Although there is a result of analyzing the risk of ground subsidence according to the deterioration of the existing pipeline, there is no result of analyzing the risk of ground subsidence using the density of pipelines indicating ground disturbance. Therefore, in this study, the density of the underground space was analyzed using the data of six types of representative underground pipelines in Seoul, and a study was conducted on whether there is a correlation with the ground subsidence. As a result, it was found that the density of underground facilities is high in the area where the ground subsidence occurred, indicating that the density of pipelines have an effect on the ground subsidence.

A study on performance analysis and merging techniques of sensors in water quality measurement (수질계측센서의 성능분석 및 센서 융합기술에 관한 연구)

  • Yang Keun-Ho;Yoo Byung-Kook
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.7 no.3
    • /
    • pp.143-148
    • /
    • 2006
  • There are need to manage the water quality to supply an safety to consumer through pipe and reservoir the drinking water that produced in a clean water reservoir. However, a management of water quality and monitoring in reservoir have never been performed. Recently, the government has enforced standards of water quality. However, we have a inferior technology of water quality as compared with one in USA, Japan, Germany, etc. In case of water quality inspection and analysis equipments, sensor technology is very important to improve the water quality inspection and to develop the analysis equipments. In this paper, we analyze a law and a regulation for management of drinking water quality, and propose the measurement standards of drinking water quality in pH, conductivity, residual chloride, turbidity and water temperature. Then, we analyze electrode sensors that interference within pH, conductivity, residual chloride in interference experiment.

  • PDF

Application of District Cooling System for Deep Ocean Water by Case Study (사례 분석을 통한 해양심층수의 지역냉방시스템 적용 방안)

  • Jin, Su-Hwuy;Park, Jin-Young;Kim, Sam-Uel;Kim, Hyeon-Ju
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.179-184
    • /
    • 2011
  • The development of new energy has attracted consideration attention due to the high oil price and environmental problems. In advanced country, they have tried to carry out a long range plan for energy. We need to develop new energy for Low Carbon Green Growth in Korea. The building is 30% among ratio of energy consumption in Korea. And in the past, heating energy was high ratio for energy using at home. But recently, the demand for cooling energy keeps growing due to rising average temperature on the earth and improvement of life quality. In this situation, the energy of lake water and ocean water has studied to utilize in advanced country because of low temperature at underwater. But the study for deep water is still a lot left to do. In this study, we analyzed district cooling system and the present condition. Analyzing the deep lake water cooling system in Toronto, we found an application of district cooling system using deep ocean water. Deep lake water uses heat source for district cooling and water source for city in Toronto. So reducing the initial cost, this city had economic effect. When DLWC was applied at existing building, the heat exchanger was installed instead of cooling tower and refrigerator. And the heat exchanger used to connect main pipe with cool water on city. System using deep ocean water can be applied as a similar way to supply cool water from lake to building.

  • PDF

Development of 3D Underground Information Construction and Visualization System Based on IUGIM (지하공간통합지도 기반 3차원 지하정보 구축 및 가시화시스템 개발)

  • Kang, Kyung Nam;Kim, Wooram;Hwang, Seung Hyun;An, Joon Sang
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.39 no.6
    • /
    • pp.497-505
    • /
    • 2021
  • Due to recent underground space accidents, are a frequent occurence in Korea, the government established the basic plan for the construction of the IUGIM (Integrated Underground Geospatial Information Map) in 2015 as a measure for safety management of underground spaces. The development of IUGIM was partially completed as of 2021. The underground space management entity and related organizations are utilizing it. This study is being carried out as part of a plan to improve the usability of IUGIM, and to build a visualization system that compares real-time field data with stored data. A system, equipped with a visualization function for borehole data and 6 types of underground facilities built and managed on IUGIM; a tool capable of comparative analysis with real-time data measured in the field, is being built. The 6 types of underground facilities are water supply pipe, sewage pipe, power pipe, gas pipe, communication pipe, and heating pipe. The completed system was demonstrated at three locations in Seocho-gu, Gangnam-gu in Seoul. The field demonstration was carried out by accessing the mobile center and downloading IUGIM data, visualizing IUGIM data (surface creation, borehole information, underground facilities), and visualizing the GPR(Ground Penetrating Radar)-based data acquired at the field. As a result of the empirical results of IUGIM data and GPR-based field data, it was judged to be suitable. As a result of this study, it is judged that it can be helpful for safe construction at the excavation site.

A Study on the Actual Survey and Reduction of Plumbing Noise in Apartment Houses (공동주택 급배수 설비소음의 실태 및 저감방안에 관한 연구)

  • Kim, Heung-Sik;Ji, Yong-Kyoun;Yoon, Se-Cheol
    • The Journal of the Acoustical Society of Korea
    • /
    • v.9 no.4
    • /
    • pp.45-54
    • /
    • 1990
  • As the results of actual survey of indoor noise in apartment houses, it represents that plumbing noise and floor impact noise are most unsatisfactory factors to inhabitants. In this paper, the actual condition of plumbing noise in apartment houses was measured and the methods of plumbing noise reduction are suggested. For these suggestions, the actual survey of plumbing noise and the model test on structure-borne sound of water supply pipe and drain sound were carried out.

  • PDF

A Study on the Operating Characteristics of Variable Speed Pump for In-Line Booster Pumping Station (직결식 변속펌프의 운전 방안에 대한 연구)

  • Park, Jong-Moon;Choi, Sung-Il;Roh, Hyung-Woon;Suh, Sang-Ho;Kim, Sang-Gyun
    • 유체기계공업학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.191-196
    • /
    • 2001
  • In the systems with largely pipe head loss, variable speed pumps are generally used because substantial energy saving can be expected from such systems by controlling pump speed and also they offer simpler maintenance and operational ease even in conditions where abrupt changes In flow rate and head can occur. The invertor or the fluid coupling system are mainly adopted to control the rotating speed. In this paper, operating conditions at Migum pressing pump station(5 stage), where the fluid coupling system was the first installed for KOWACO, are investigated and analysed so that information thus gained can be usefully employed in the efficient operation of variable speed pump in new installations of in-line booster pumping station.

  • PDF

Ghost Junction Method for Flow Network System Analyses (유동망 시스템 해석을 위한 유령 정션 기법)

  • Hong, Seok-Woo;Kim, Chong-Am
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.626-629
    • /
    • 2008
  • Numerical predictions on flow phenomena in pipe network systems have been considered as playing an important role in both designing and operating various facilities of piping or duct systems, such as water supply, tunnel or mine ventilation, hydraulic systems of automobile or aircraft, and etc. Traditionally, coupling conditions between junction and connected branches are assumed to satisfy conservation law of mass and to share an equal pressure at junction node. However, the conventional methodology cannot reflect momentum interactions between pipes sufficiently. Thus, a new finite volume junction treatment is proposed both to reflect the interchanges of linear momentums between neighbor branches at junction and to include the effect of wall at junction in present work.

  • PDF

Analysing the Effect of Residual Chlorine Equalization for Water Quality Improvement in Water Distribution System (공급과정 수질개선을 위한 잔류염소 균등화 효과분석)

  • Choi, Taeho;Lee, Doojin;Bae, Cheolho;Moon, Jiyoung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.5
    • /
    • pp.587-596
    • /
    • 2016
  • This study attempts to draw factors for an analysis of the operation effect of a rechlorination facility and autodrain equipment for residual chlorine equalization by installing and operating a rechlorination facility and autodrain equipment in P City and analyzing the practical evaluation method and operation effect. For this purpose, this study selected three indicators for an analysis of the effectiveness of residual chlorine equalization and conducted a comparative analysis before and after the implementation of the residual chlorine equalization. As a result of estimation, (1) the reduction of the residual chlorine concentration range from a water treatment plant to the pipe end was 16.0%; (2) the total reduction of chlorination input was 18.0%; and (3) the reduction of the generation of disinfection by-products was 19.5%. In addition, this achieved enough residual chlorine equalization in the supply process and shows that it could successfully achieve the economic feasibility of investment in equipment and the reduction of the generation of disinfection by-products. Like this, it is judged that the three indicators suggested in this study will be used sufficiently as indicators of an analysis of the effectiveness of residual chlorine equalization according to the operations of the rechlorination facility and autodrain equipment.

A Study on the Deterioration Patterns of Building Components in the Rental Apartment Housing (임대공동주택 구성재의 열화도 패턴에 관한 연구)

  • Lee Kang-Hee
    • Journal of the Korean housing association
    • /
    • v.17 no.4
    • /
    • pp.65-72
    • /
    • 2006
  • Most of buildings have been deteriorated with time-elapse by reflection of the building location, material, environmental circumstances and so on. The performance would go down and be demolished if anything could not be done after constructed. The maintenance should be required to preserve a decent living condition or improve a inferior condition by various plans and practices. The maintenance plan needs various data such as a repair scope, a repair time, a forecasted cost, a plan of management and so forth. Among the above required data for planning the maintenance, the deterioration characteristics of the building components would be first analyzed. The deterioration pattern would be a key role to affect and make a maintenance plan. In this paper, it aimed at classifying the deterioration patterns of building components. A deterioration pattern would be analyzed between the cumulative repair cost and time-elapse and modeled with these relations. A deterioration patterns are classified into 4 types-a accelerated type, a straight type, a temporary type and a slowly type. As a result of this research, a accelerated type includes window, window frame, general paintings, general water proofing in building components. A straight type includes the lacquer paintings, furnishings in building components and water supply pipe, boiler, sanitaries in mechanical facilities and lighting in electric facilities. Based on these research results, further study should be conducted to include any other components and an estimating model.

Improvement of Pad Lifetime using POU (Point of Use) Slurry Filter and High Spray Method of De-Ionized Water (POU 슬러리 필터와 탈이온수의 고분사법에 의한 패드수명의 개선)

  • 박성우;김상용;서용진
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.9
    • /
    • pp.707-713
    • /
    • 2001
  • As the integrated circuit device shrinks to smaller dimensions, chemical mechanical polishing (CMP) process was requirdfo the global planarization of inter-metal dielectric (IMD) layer with free-defect. However, as the IMD layer gest thinner, micro-scratches are becoming as major defects. However, as the IMD layer gets thinner, micro-scratches are becoming as major defects. Micro-scratches are generated by agglomerated slurry, solidified and attached slurry in pipe line of slurry supply system. To prevent agglomerated slurry particle from inflow, we installed 0.5${\mu}{\textrm}{m}$ point of use (POU) filter, which is depth-type filter and has 80% filtering efficiency for the 1.0${\mu}{\textrm}{m}$ size particle. In this paper, we studied the relationship between defect generation and polished wafer counts to understand the exact efficiency fo the slurry filteration, and to find out the appropriate pad usage. Our experimental results showed that it sis impossible to prevent defect-causing particles perfectly through the depth-type filter. Thus, we suggest that it is necessary to optimize the slurry flow rate, and to install the high spray bar of de-ionized water (DIW) with high pressure, to overcome the weak-point of depth type filter.

  • PDF