• Title/Summary/Keyword: Water pipe supply

Search Result 265, Processing Time 0.031 seconds

Quantitative Evaluation of Remote Field Eddy Current Defect Signals (배관 결함부 원거리장 와전류 신호 정량화 연구)

  • Jeong, Jin-Oh;Yi, Jae-Kyung;Kim, Hyoung-Jean
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.6
    • /
    • pp.555-561
    • /
    • 2000
  • The remote field eddy current (RFEC) inspection was performed on the ductile cast iron pipes with nominal outer diameter of 100mm, which were machined with various shapes and sizes of defects. Ductile cast iron pipes which are used as water supply pipe have the non-uniform thickness and asymmetric cross section due to relatively high degree of allowable errors during the manufacturing processes. These characteristics of ductile cast in pipes cause the long range background noises in RFEC signals along the pipe. In this study, tile machined defects in pipes were effectively classified by the moving window average (MWA) method which eliminated the long-range noise. The voltage plane polar plots (VPPP) method was used to quantitatively evaluate the depth and circumferential degree of defects. The VPPP signatures showed that the angle between defect signature and the normalized in-phase component on the VPPP is linear to the depth of defects. The nondestructive RFEC technique proved to be capable of quantitatively evaluating the machined defects of underground water supply pipe.

  • PDF

Introduction to Image Processing Technology for Precise Positioning of Underground Buried Lifelines (영상정보 기반 지하매설관 정밀 위치조사 기술 소개)

  • Ryu, Byunghyun;Cheon, Jangwoo;Lee, Chulhee;Lee, Impyeong;Lee, Jangguen;Kang, Jaemo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.22 no.12
    • /
    • pp.51-57
    • /
    • 2021
  • Underground lifelines such as water supply/sewer pipe, power cable and gas pipe are indispensable facilities to the life of urban society. These lifelines have been constructed long time ago and buried positioning information is not precisely recorded. Moreover, they have been concentrated on the narrow area and are complicatedly entangled in 3-dimension. In the fourth industrial revolution, a 3-dimensional visualization for underground lifelines is strongly required, and a database (D/B) with precise positioning information should be preceded. In this study, image processing technology for precise positioning of underground buried lifelines is introduced, which is able to build the database more accurately, efficiently and practically.

An Improvement Study on National Fire Safety Code of Sprinkler System for Hydraulic Calculation Application (수리계산 적용을 위한 스프링클러설비의 화재안전기준 개선방안 연구)

  • Lee, Keun-Oh;Kang, Joo-Hyeong
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.1 s.79
    • /
    • pp.7-12
    • /
    • 2007
  • There are two kinds of design process for sprinkler system. one is pipe schedule system and the other is hydraulically designed system. We have inefficient results when we design by hydraulically designed system because the design process for sprinkler system is restricted by domestic fire code. Therefore, it is essential to do an introduction of hydraulically designed system which is based on engineering for enhancing reliability and efficiency of sprinkler system. This study presents points at issue by comparing and studying design standards of sprinkler system from Korea, Japan and NFPA, and presents improvement plans of national fire safety code of sprinkler system by processing, comparing and analyzing designs according to piping schedule and hydraulically designed system about domestic objects. Installation standards of sprinkler system have to be applied not by object buildings but by hazard classification. It is hard to design an efficient sprinkler system for fire control when water supply requirement of sprinkler systems allocated according to a size of a building because the same purpose but other buildings may request more water requirement or less. We should sublate the pipe schedule system from national fire safety code and need to introduce the hydraulically designed system. The pipe schedule system presents easy access because it is based on the forecasted engineering calculations but it is applied to only small buildings like NFPA due to its low reliability.

Occurrence of Disinfection By-Products and Distribution in Drinking Water

  • In, Chi-Kyung;Lee, Jung-Ho;Lee, In-Sook
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2005.12a
    • /
    • pp.103-114
    • /
    • 2005
  • Chlorine disinfection has been used in drinking water supply to disinfect the water-borne microbial disease which may cause to serious human disease. As Chlorination is still the least costly, relatively easy to use, chlorination is the primary means to disinfect portable water supplies and control bacterial growth in the distribution system. However, chlorine also reacts with natural organic matter (NOM), which presents in nearly all water sources, and then produces disinfection by-product (DBps), which may have adverse health effects. Although the existent DBPs have been reported in drinking water supplies, it is not feasible to predict the levels of the various DBPs due to the complex chemistry reaction involved. The objectives of this study were to investigate seasonal variation of DBPs formation and difference of DBPs concentration in the plant to tap water. The average concentration of THMs was 20.04 ${\mu}g/{\ell}$, HAAs 8-15 ${\mu}g/{\ell}$, HANs 2-4.5 ${\mu}g/{\ell}$ respectively. Distant variation of DBPs formation is that THMs concentration increase by 17% at 2 km point from the plant and by 28% at 7 km and HAAs, HANs also increase each by 16%, 32%, at 2 km from the plant and 35%, 56%, at 7 km. DBPs increase in water supply pipe continually. The seasonal occurrence of DBPs is that in May and August DBPs concentration is very high then in March, in May DBPs concentration is highest. The temperature is main factor of DBPs formation, precursor also. Precursor which was accumulated for winter flowed into the raw water by flooding in spring and summer and produced DBPs. Therefore for the supply of secure drinking water, it is required to protect precursor of flowing into raw water and to add to BCAA and DBAA to drinking water standards.

  • PDF

Development of a Monitoring System for a Pipe Cleaning Robot with RS-485 (RS-485 통신을 이용한 배관청소 로봇의 모니터링 시스템 개발)

  • Kim, Min-wook;Lee, Hun-seok;Oh, Jin-seok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.5
    • /
    • pp.923-930
    • /
    • 2016
  • Various pipes are used in the many industrial field such as water supply, drainage system and marine plants, so a maintenance of these pipes is essential. Especially, the maintenance of the piping in the industrial field, some professional staffs enter and clean the pipe. If the professional staffs can not enter and clean the pipe, the workers has to use the method of inserting a scraper connected to wire inside the pipe. However, this method demands huge budget and causes a number of problems such as traffic congestion. To solve these problems, pipe cleaning robot has been researching and developing. Many Pipe cleaning robots have a problem, that is impossible to confirm the operating condition of the robot in a real time. This paper suggest pipe cleaning robot with RS-485 which transmit operating and cleaning condition of robot and inner pipe filmed by camera, that user can check.

The Study on Automatic Temperature Transmission System for the Heating pipe at Home (가정식난방배수관내의자동온도송신장치에대한연구)

  • Park, Chul-Min;Jo, Heung-Kuk;Lee, Hoon-Jae
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.12
    • /
    • pp.2641-2646
    • /
    • 2009
  • The more growing on home automation system at automatic control, the more efficiency required for energy consumption and for recycling energy in near future. Heating is essential in general apartment. Heating method is two types in apartment. One uses electricity, and other one uses warm water. If use electricity, is not efficient by rise of electric charges. But, It can reduce much in expense aspect, if use warm water. When use warm water, temperature of warm water is not equal from all pipe parts. Therefore, indoor tempera can be unequal with set point. Solution of these problems is as following. Temperature sensor in warm water attach pipe. The measured temperature transmits by real time. Temperature of warm water controls in receiver side. In this paper, we propose an automatic temperature transmission system for the heating pipe at home, that is a low-power based, and supply the energy source from a small AC motor resided in bottom cement mortal. The proposed system is used in power mechanism from a collision process of water-jet using propeller water-difference and also designed a CPU module by Atmega8 at ATMEL co., Inc. and a communication module by CC1020 at Chipcon co., Inc.

CHANGES IN WATER USE AND MANAGEMENT OVER TIME AND SIGNIFICANCE FOR AUSTRALIA AND SOUTH-EAST ASIA

  • Knight, Michael J.
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1997.11a
    • /
    • pp.3-31
    • /
    • 1997
  • Water has always played a significant role in the lives of people. In urbanised Rome, with its million people. sophisticated supply systems developed and then fled with the empire. only to be rediscovered later But it was the industrial Revolution commencing in the eighteenth century that ushered in major paradigm shifts In use and altitudes towards water. Rapid and concentrated urbanisation brought problems of expanded demands for drinking supplies, waste management and disease. The strategy of using water from local streams, springs and village wells collapsed under the onslaughts of rising urban demands and pollution due to poor waste disposal practices. Expanding travel (railways. and steamships) aided the spread of disease. In England. public health crises peaks, related to water-borne typhoid and the three major cholera outbreaks occurred in the late eighteenth and early nineteenth century respectively. Technological, engineering and institutional responses were successful in solving the public health problem. it is generally accepted that the putting of water into pipe networks both for a clean drinking supply, as well as using it as a transport medium for removal of human and other wastes, played a significant role in towering death rates due to waterborne diseases such as cholera and typhoid towards the end of the nineteenth century. Today, similar principles apply. A recent World Bank report Indicates that there can be upto 76% reduction in illness when major water and sanitation improvements occur in developing countries. Water management, technology and thinking in Australia were relatively stable in the twentieth century up to the mid to late 1970s. Groundwater sources were investigated and developed for towns and agriculture. Dams were built, and pipe networks extended both for supply and waste water management. The management paradigms in Australia were essentially extensions of European strategies with the minor adaptions due to climate and hydrogeology. During the 1970s and 1980s in Australia, it was realised increasingly that a knowledge of groundwater and hydrogeological processes were critical to pollution prevention, the development of sound waste management and the problems of salinity. Many millions of dollars have been both saved and generated as a consequence. This is especially in relation to domestic waste management and the disposal of aluminium refinery waste in New South Wales. Major institutional changes in public sector water management are occurring in Australia. Upheveals and change have now reached ail states in Australia with various approaches being followed. Market thinking, corporatisation, privatisation, internationalisation, downsizing and environmental pressures are all playing their role in this paradigm shift. One casualty of this turmoil is the progressive erosion of the public sector skillbase and this may become a serious issue should a public health crisis occur such as a water borne disease. Such crises have arisen over recent times. A complete rethink of the urban water cycle is going on right now in Australia both at the State and Federal level. We are on the threshold of significant change in how we use and manage water, both as a supply and a waste transporter in Urban environments especially. Substantial replacement of the pipe system will be needed in 25 to 30 years time and this will cost billions of dollars. The competition for water between imgation needs and environmental requirements in Australia and overseas will continue to be an issue in rural areas. This will be especially heightened by the rising demand for irrigation produced food as the world's population grows. Rapid urbanisation and industrialisation in the emerging S.E Asian countries are currently producing considerable demands for water management skills and Infrastructure development. This trend e expected to grow. There are also severe water shortages in the Middle East to such an extent that wars may be fought over water issues. Environmental public health crises and shortages will help drive the trends.

  • PDF

An Optimal Conjunctive Operation of Water Transmission Systems from Multiple Sources with applying EPAnet and KModSim Model (KModSim 모형(模型)에 의한 도시지역(都市地域) 다중수원(多衆水源) 송수관망간(送水管網間) 최적(最適) 연계(連繫) 운영(運營) 연구(硏究))

  • Ryu, Tae-Sang;Cheong, Tae-Sung;Ko, Ick-Hwan;Ha, Sung-Ryong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.500-504
    • /
    • 2008
  • The objective of this paper is to evaluate the feasibility of using an optimization model as a effective way to search conjunctive operation scheme to meet two conditions; one is to minimize the electric cost for pumping and another is to meet the water demand for satisfying customers. The feasibility is confirmed as comparing the best combinations of pumps between multi-regional water supply networks from multiple sources which are obtained through an optimization modeling and EPAnet modeling. KModsim model, a network optimization model, was used to determine conjunctive operation scheme in the pipe system. KModsim, based on Lagrangian Relaxation algorithm, is useful for modeling network system and obtaining simultaneously pump combination and water allocation with given input option such as energy unit cost supplying from a source into a consumer, operating pumping combination. This study develops the procedure of determining optimal conjunctive operation scheme with using KModsim model. As a study region, the water supplying systems of the Geojae-city in the Geongsang Namdo Province was selected and investigated. The EPAnet hydraulic simulation result(Ryu et al, 2007, KSWW) gave input data for optimization model; energy unit price(won/$m^3$), water service available area etc.. It was assured that the combination of pump operation through optimum conjunctive operation is to be optimum scheme to obtain the best economic water allocation with comparison to the hydraulic simulation result such as electric cost and pump combination cases. The results obtained through the study are as follows. First, It was found that a well-allocated water supply scheme, the best combination of pump operation through optimum joint operation, promises to save the electric cost and satisfy all operational goals such as stability and revenues during the period. Second, an application of KModSim, a network model, gave the amount of water allocation from each source to a consumer with consideration of economic supply. Finally, in a service area available to supply through conjunctive operation of existing inter-regional water supply networks within short distance, a conjunctive operation is useful for determining each transmission pipeline's service area and maximizing the effectiveness of optimizations in pumping operation time.

  • PDF

Effect and Issues on the Water Supply Network Management System in Kwangju (광주시 상수도관망관리시스템의 효과 및 문제점에 관한 연구)

  • 오창수
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.16 no.1
    • /
    • pp.103-110
    • /
    • 1998
  • This study deals with the effective management system on the underground facilities by Geographic In-formation System (GIS). For this purpose,"Management System on the Water Supply Network by GIS in Kwangju" was analylized. Following results were obtained in this study. This system could be practically used for the inquiry of water supply and distribution pipes, check valves, pipe equipments and parcel identification numbers. Inquiry of addresses using the parcel identification numbers were effective for the database management system of the water supply facilities. The poits at issue for the performance of this study were the security and education of experts, the security of revenue source, the discord between GIS companies concerned. Establishments of GIS software technologies and database systems, and the settlement between GIS companies were required for the solution of these poits. Development of computer management systems on the water sup-ply network by GIS enabled the replacement of outworn pipes and the leakage inquiry techniques in pipes. in pipes.

  • PDF

Study of Drinking water pipeline Corrosion Mechanism by using Scale Analysis (부식 생성물 분석법을 이용한 상수도 금속관의 부식거동에 관한 연구)

  • 황상용;송호봉
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.1
    • /
    • pp.57-62
    • /
    • 2002
  • Carbon cast iron and Zinc coated steel were the most widely used portable water of supply and distribution Pipeline system. The leaching of red water in portable water could produce sericus environmental sanitary problems. Due to the red water was the most alternative to inner scale of metal pipeline. So this study was conducted the impact of red water on scale products, and was evaluated by the corrosive metal contaminants of 20 fears over. Surface tests, metal surface composition measurements of samples XRF, XRD, and SEM(EDS), analysis were used to investigate the corrosion characteristies of carbon cast iron and Zinc coated steel. As the contaminants of Fe increased the red water of carbon castiron pipe increased due to the scale products amount of $Fe_2O_3$ (Hemite).