• 제목/요약/키워드: Water pipe

검색결과 1,715건 처리시간 0.032초

원전 2차계통의 수화학 변화가 배관감육에 미치는 영향 분석 (Analysis of Pipe Wall-thinning Caused by Water Chemistry Change in Secondary System of Nuclear Power Plant)

  • 윤훈;황경모;문승재
    • Corrosion Science and Technology
    • /
    • 제14권6호
    • /
    • pp.325-330
    • /
    • 2015
  • Pipe wall-thinning by flow-accelerated corrosion (FAC) is a significant and costly damage of secondary system piping in nuclear power plants (NPPs). All NPPs have their management programs to ensure pipe integrity from wall-thinning. This study analyzed the pipe wall-thinning caused by changing the amine, which is used for adjusting the water chemistry in the secondary system of NPPs. The pH change was analyzed according to the addition of amine. Then, the wear rate calculated in two different amines was compared at the steam cycle in NPPs. As a result, increasing the pH at operating temperature (Hot pH) can reduce the rate of FAC damage significantly. Wall-thinning is affected by amine characteristics depending on temperature and quality of water.

평판형 히트파이프식 핫척의 표면온도 균일화 향상을 위한 연구 (Study on Improvement of Surface Temperature Uniformily in Flate-Plate Heat Pipe Hot Chuck)

  • 김대현;이석호;임택규;이충구
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2369-2374
    • /
    • 2008
  • In the precision hot plate for wafer processing, the temperature uniformity of upper plate surface is one of the key factors affecting the quality of wafers. Precision hot plates require temperature variations less than ${\pm}1.5%$ during heating to $120^{\circ}C$. In this study, we have manufactured the flat plate heat pipe hot chuck of circle type(300mm) and investigated the operating characteristics of flat plate heat pipe hot chuck experimentally. Various liquids(aceton, FC-40, water) were used as the working fluid and charging ratio was changed($14{\sim}36\;vol.%$). Several cases were tested to improve temperature uniformity. Major working fluid to be investigated was water. Using water, various parameters such as charging ratio, wafer operation on-off time, different working fluids. In case of water, the temperature uniformity was ${\pm}1.5%$, response time of wafer were investigated.

  • PDF

동관에서 pH, 알칼리도, 염소이온이 부식에 미치는 영향 (Effects of pH, Alkalinity, Chloride Ion on the Copper Pipe Corrosion)

  • 조관형;김선일;우달식
    • 한국환경보건학회지
    • /
    • 제33권1호
    • /
    • pp.43-48
    • /
    • 2007
  • This study investigated the effects of pH, alkalinity, and chlorine ion which are important water quality impact factors to the corrosion in the simulated distribution system where the copper pipe is affixed. The result shows that pitting index was increased as the alkalinity and chloride ion increase in the distilled water, but there was no relation to pH. Actually the uniform corrosion rate was decreased as the pH increase with the laboratory tap water. In conclusion, it is necessary to control the pH which stands above minimum 7.5 to prevent pitting corrosion in the copper pipe. Consequently, comprehensive research about the effect of lime soda($Ca(OH)_2$) which was used as a coagulation additive in the water treatment plant to pipe corrosion must be accomplished additionally.

상수관로 개량 우선순위 수립을 위한 퍼지 기법 (Fuzzy Techniques to Establish Improvement Priorities of Water Pipes)

  • 박수완;김태영;임기영;전환돈
    • 한국수자원학회논문집
    • /
    • 제44권11호
    • /
    • pp.903-913
    • /
    • 2011
  • 본 논문에서는 상수관로의 개량(교체또는갱생) 우선순위를 결정하는데 있어서 평가되어야 할 인자 또는 요소를 관로의 파손이 전체관망에 미치는 영향 및 개별관로의 특성으로 구분하였고, 이들을 퍼지기법을 적용하여 정량적으로 산정할 수 있는 모형을 개발하였다. 퍼지기법으로 산정되는 관로의 파손이 전체관망에 미치는 영향을 관로의 퍼지 중요도로 정의하였으며, 개별관로의 특성은 관로의 퍼지 특성도로 정의하였다. 퍼지 특성도는 다시 퍼지 노후도 및 퍼지 난이도 등으로 구분하여 산정할 수 있게 하였다. 한편, 각 평가요소를 퍼지기법으로 산정함에 있어서 적합한 평가대상이 차지하는 비중에 따라 평가대상의 가중치를 고려할 수 있도록 하였다. 본 연구에서 개발된 방법론의 적용예를 제시하기 위하여 EPANET 관망해석 프로그램의 예제관망으로 제공되는 Net3 관망을 이용하였다. 관로의 파손이 전체관망에 미치는 수리학적 영향과 개별 관로의 특성중의 하나인 관로의 노후도를 Net3 관망내 관로 개량 우선순위 결정에 고려하여야 할 요소로 선정하여 Net3 관망 내 관로의 퍼지 중요도(Fuzzy Importance Index, FII) 및 퍼지 노후도(Fuzzy Deterioration Index, FDI)를 산정하였으며, 이를 이용하여 Net3 관망내 관로의 개량 우선순위를 수립하였다.

상수관 파괴에 의한 피해 경감기법의 개발 (Development of a Method to Reduce Damages by Pipe Failures)

  • 전환돈;;박무종;김중훈;이환구
    • 한국방재학회 논문집
    • /
    • 제8권6호
    • /
    • pp.31-36
    • /
    • 2008
  • 배수시설은 합리적인 계획으로 배치하여 시간적으로 변동하는 수요량에 대하여 적정한 수질의 물을 적정한 압력으로 연속적이면서 안정적으로 공급해야 한다. 또한 상수관 파괴 같은 사고가 발생했을 경우에도 용수 수요자에 대한 영향을 최소화 할 수 있는 안정성이 높은 시설을 목표로 구축되어야 한다. 본 연구에서는 상수관 파괴에 의한 피해를 합리적으로 경감시킬 수 있는 방법을 제시하였다. 본 연구를 위해 기존의 상수관 파괴에 의한 피해영역 산정기법과 신뢰도 산정기법을 통해서 상수관망을 분석하고 상수관 파괴에 의한 피해 경감기법을 도출하였다. 분석결과 minimum cutset에 속하는 상수관의 내구성을 중요우선순위에 따라 향상시킴으로써 상수관 파괴에 의한 피해를 효과적으로 경감시킬 수 있었으며 제안된 방법을 Cherry Hill 상수관망에 적용하여 적용성을 검증하였다.

건축설비용 워터햄머흡수기의 동특성에 관한 수치 연구 (A Numerical Study on the Dynamic Characteristics of Water Hammer Arresters for Building Service Applications)

  • 노승환;차동진
    • 설비공학논문집
    • /
    • 제14권4호
    • /
    • pp.269-277
    • /
    • 2002
  • Dynamic characteristics of water hammer arresters installed in a building water supply system have been investigated numerically by utilizing a commercial rode that employs the method of characteristics. Some preliminary results with those arresters produced in this study agree well with the previously reported. Then, the arresters have been incorporated into a water supply pipe system of a $59m^2$ apartment unit constructed by a leading construction company, and their dynamic characteristics, especially on the reduction in the water hammer pressure, are investigated. It is found that the setting of the arresters in the pipe system, which is recommended by the company, may not be proper for reducing the pressure to less than 1082.0 kPa when buick-closure valves in the pipe system are closed within 30 ms at the static pressure of 542.6 kPa. More arresters in the system may be required to meet a pressure criteria.

요인실험계획을 이용한 수도관 생물막 형성 영향 인자의 효과 분석 (Analysis of Effects of Factors Influencing Biofilm Formation in Drinking Water Distribution Pipe Using Factorial Experimental Design)

  • 박세근;최성찬;김영관
    • 상하수도학회지
    • /
    • 제19권2호
    • /
    • pp.181-192
    • /
    • 2005
  • This study evaluated the effect of factors influencing the initial biofilm formation in drinking water distribution pipe by running experiments using a $2^{4-1}$ fractional factorial experimental design with a replicate. Important variables used for assessing biofilm formation included BDOC(biodegradable dissolved organic carbon), viable heterotrophic bacteria present in drinking water, water temperature, and shear stress at two levels each. Based on the statistical analysis of biofilm levels measured as attached HPC(heterotrophic plate count) and community-level assay, the main factors that have significant effects on biofilm formation were found to be viable heterotrophic bacteria and BDOC. Water temperature only exhibited significant effect on the levels of attached HPC, while shear stress was not a significant factor under given conditions. Moreover, the statistical analysis revealed that interactions between the important variables were not statistically significant at a 0.05 significance level.

초고압수를 이용한 노후한 도수 강관 내 스케일 제거에 대한 실험적 연구 (The Experimental Study of Scale Removal Using Ultra High Water Pressure in the Old Steel Water Pipe)

  • 서태원;김진동;서현원;김태동
    • 상하수도학회지
    • /
    • 제22권4호
    • /
    • pp.405-409
    • /
    • 2008
  • This technical paper is proposing a sound concept in the application of the rehabilitation method of the water supply steel pipe in the large diameter ranged from 1,800mm to 3,500mm. There were conducted the experimental tests for the specimens as well as the real steel pipe of diameter 2,200mm. The water pressure ejected from nozzle tip should be at least 2,500bar to have the satisfied surface profiles required in the design criterion. The most difficult thing is to keep the water pressure at the nozzle tip as 2,500bar during the consecutive work in the interval of the work site more than 1km. It is found that the method suggested in this study is adequate method to meet the specified design criteria. The results of this study provide the useful information how to setup the equipments for the successful work. This method also provides not only the omission of the blasting process but also the effect of the budget reduction.

상수관로 파손으로 인한 지반함몰 발생메카니즘에 관한 실험적 연구 (Experimental Study on Generating mechanism of The Ground Subsidence of Due to Damaged Waters supply Pipe)

  • 김영호;김주봉;김도원;한중근
    • 한국지반신소재학회논문집
    • /
    • 제16권2호
    • /
    • pp.139-148
    • /
    • 2017
  • 상하수도관의 파손에 따라 발생하는 지반함몰은 최근 많은 도시에서 증가하고 있다. 이는 도시의 노후화에 따른 파이프라인의 노후화에 기인한다. 하수도의 파손에 따른 지반함몰특성은 최근 많은 연구들을 통해 밝혀지고 있지만, 상수도에 의한 지반함몰 특성 연구는 미진한 상태라 할 수 있다. 본 연구에서는 상수도관의 파손에 따른 매설관 상부지반의 지반함몰 발생메카니즘을 알아보기 위해 지반특성과 상수도관에서의 압력 및 속도수두에 따른 지반붕괴특성을 실내모형시험을 통해 고찰하였다. 상수도관의 매설상태를 고려하여 상대밀도와 세립토의 함유량에 따라 비교분석하였다. 상대밀도와 침투압이 작은 경우에는 소규모지반함몰이 발생할 수 있고, 반대인 경우에는 지중공동이 크게 발생하면서 일정시간이 지난 후 지표면으로 확대되어 발생하는 것을 알 수 있었다. 또한, 지중 깊은 곳에서 침투압에 의한 토사유출이 발생한 이후 형성된 지반공동은 장시간동안 지표면 부근에서 일정한 강도를 유지하고, 지반공동이 장기간 유지될 수 있음을 알 수 있었다.

온실 난방시스템 설계를 위한 온수난방배관의 방열량 분석 (Analysis of Heat Emission from Hot Water Pipe for Greenhouse Heating System Design)

  • 신현호;남상운
    • 생물환경조절학회지
    • /
    • 제28권3호
    • /
    • pp.204-211
    • /
    • 2019
  • 본 연구는 국내 온실의 환경설계 기준 설정에 필요한 기초자료 제공을 목적으로 온수난방 방식을 채택하고 있는 상업용 온실 2곳에서 난방 중 열환경 계측 실험을 실시하고, 온수난방 배관의 열전달 특성을 분석하여 난방배관의 단위길이 당 방열량 자료를 제시하였다. 실험 기간동안 두 온실의 평균기온은 각각 $16.3^{\circ}C$$14.6^{\circ}C$로 조절되었으며, 난방배관의 온수 온도는 평균 $52.3^{\circ}C$$45.0^{\circ}C$로 관측되었다. 실험결과 난방배관 표면의 자연대류열전달계수는 $5.71{\sim}7.49W/m^2^{\circ}C$의 범위로 분석되었다. 난방배관 내의 유속이 0.5m/s 이상일 때에는 관내의 수온과 관 외부의 표면온도 차이가 크지 않은 것으로 나타났다. 이를 바탕으로 난방배관의 관류열전달계수를 수평원통에서의 층류 자연대류열전달계수의 형태로 유도하였다. 유도된 관류열전달계수 식을 변형하여 관의 규격과 온수-실내공기의 온도차를 입력 변수로 하는 난방배관의 단위길이 당 방열량 산정식을 개발하였다. 본 연구 결과를 기존에 제공되고 있는 국내외 여러 자료와 비교한 결과 JGHA 자료와 가장 유사한 것으로 나타났다. 국내 온실의 설계에서 적용하고 있는 NAAS 자료와 국외의 BALLS 및 ASHRAE 자료는 값이 너무 큰 것으로 판단된다. 따라서 국내 온실의 환경설계기준을 제정하고, 고시하기 위해서는 추가적인 실험을 통해 이 부분에 대한 충분한 검토가 필요할 것으로 판단된다.